A comparative study of viscoelasticity between normal cornea and keratoconus

Study of the mechanical properties of in vivo corneal materials is an important basis for further study of corneal physiological and pathological phenomena by means of finite element method. In this paper, the elastic coefficient ( ) and viscous coefficient ( ) of normal cornea and keratoconus under...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sheng wu yi xue gong cheng xue za zhi 2019-08, Vol.36 (4), p.613
Hauptverfasser: Zhao, Kechao, Wang, Xiaojun, Chen, Weiyi, He, Rui, Li, Xiaona, Gao, Yan
Format: Artikel
Sprache:chi
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 4
container_start_page 613
container_title Sheng wu yi xue gong cheng xue za zhi
container_volume 36
creator Zhao, Kechao
Wang, Xiaojun
Chen, Weiyi
He, Rui
Li, Xiaona
Gao, Yan
description Study of the mechanical properties of in vivo corneal materials is an important basis for further study of corneal physiological and pathological phenomena by means of finite element method. In this paper, the elastic coefficient ( ) and viscous coefficient ( ) of normal cornea and keratoconus under pulse pressure are calculated by using standard linear solid model with the data provided by corneal visualization scheimpflug technology. The results showed that there was a significant difference of and between normal cornea and keratoconus cornea ( < 0.05). Receiver operating characteristic curve analysis showed that the area under curve (AUC) for , and their combined indicators were 0.776, 0.895 and 0.948, respectively, which indicated that keratoconus could be predicted by and . The results of this study may provide a reference for the early diagnosis of keratoconus and avoid the occurrence of keratoconus after operation, so it has a certain clinical value.
doi_str_mv 10.7507/1001-5515.201812052
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_2298147264</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2298147264</sourcerecordid><originalsourceid>FETCH-LOGICAL-p562-8994beef04d9bbb10a633bf0cbd7957f934c4fb9ed4332f5cc711c02592882183</originalsourceid><addsrcrecordid>eNo9kMFLwzAYxXNQ3Jj7CwTJ0Utn8iVpk-MY6oSCl91Lkn6BYtvUpp3sv7fg9PTg8X6PxyPkgbNdoVjxzBnjmVJc7YBxzYEpuCHrf3dFtik1jjHQLM-1uCMrwaXkkMOalHvqYzfY0U7NGWma5vpCY6DnJvmIrU1T45vpQh1O34g97ePY2XZhxh4ttX1NP3Fho4_9nO7JbbBtwu1VN-T0-nI6HLPy4-39sC-zQeWQaWOkQwxM1sY5x5nNhXCBeVcXRhXBCOllcAZrKQQE5X3BuWegDGgNXIsNefqtHcb4NWOaqm5Zi21re4xzqgCM5rKAXC7Rx2t0dh3W1TA2nR0v1d8B4geGNVzN</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2298147264</pqid></control><display><type>article</type><title>A comparative study of viscoelasticity between normal cornea and keratoconus</title><source>MEDLINE</source><source>PubMed Central</source><creator>Zhao, Kechao ; Wang, Xiaojun ; Chen, Weiyi ; He, Rui ; Li, Xiaona ; Gao, Yan</creator><creatorcontrib>Zhao, Kechao ; Wang, Xiaojun ; Chen, Weiyi ; He, Rui ; Li, Xiaona ; Gao, Yan</creatorcontrib><description>Study of the mechanical properties of in vivo corneal materials is an important basis for further study of corneal physiological and pathological phenomena by means of finite element method. In this paper, the elastic coefficient ( ) and viscous coefficient ( ) of normal cornea and keratoconus under pulse pressure are calculated by using standard linear solid model with the data provided by corneal visualization scheimpflug technology. The results showed that there was a significant difference of and between normal cornea and keratoconus cornea ( &lt; 0.05). Receiver operating characteristic curve analysis showed that the area under curve (AUC) for , and their combined indicators were 0.776, 0.895 and 0.948, respectively, which indicated that keratoconus could be predicted by and . The results of this study may provide a reference for the early diagnosis of keratoconus and avoid the occurrence of keratoconus after operation, so it has a certain clinical value.</description><identifier>ISSN: 1001-5515</identifier><identifier>DOI: 10.7507/1001-5515.201812052</identifier><identifier>PMID: 31441262</identifier><language>chi</language><publisher>China</publisher><subject>Area Under Curve ; Cornea - physiology ; Elasticity ; Humans ; Keratoconus - pathology ; ROC Curve ; Viscosity</subject><ispartof>Sheng wu yi xue gong cheng xue za zhi, 2019-08, Vol.36 (4), p.613</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31441262$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Zhao, Kechao</creatorcontrib><creatorcontrib>Wang, Xiaojun</creatorcontrib><creatorcontrib>Chen, Weiyi</creatorcontrib><creatorcontrib>He, Rui</creatorcontrib><creatorcontrib>Li, Xiaona</creatorcontrib><creatorcontrib>Gao, Yan</creatorcontrib><title>A comparative study of viscoelasticity between normal cornea and keratoconus</title><title>Sheng wu yi xue gong cheng xue za zhi</title><addtitle>Sheng Wu Yi Xue Gong Cheng Xue Za Zhi</addtitle><description>Study of the mechanical properties of in vivo corneal materials is an important basis for further study of corneal physiological and pathological phenomena by means of finite element method. In this paper, the elastic coefficient ( ) and viscous coefficient ( ) of normal cornea and keratoconus under pulse pressure are calculated by using standard linear solid model with the data provided by corneal visualization scheimpflug technology. The results showed that there was a significant difference of and between normal cornea and keratoconus cornea ( &lt; 0.05). Receiver operating characteristic curve analysis showed that the area under curve (AUC) for , and their combined indicators were 0.776, 0.895 and 0.948, respectively, which indicated that keratoconus could be predicted by and . The results of this study may provide a reference for the early diagnosis of keratoconus and avoid the occurrence of keratoconus after operation, so it has a certain clinical value.</description><subject>Area Under Curve</subject><subject>Cornea - physiology</subject><subject>Elasticity</subject><subject>Humans</subject><subject>Keratoconus - pathology</subject><subject>ROC Curve</subject><subject>Viscosity</subject><issn>1001-5515</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kMFLwzAYxXNQ3Jj7CwTJ0Utn8iVpk-MY6oSCl91Lkn6BYtvUpp3sv7fg9PTg8X6PxyPkgbNdoVjxzBnjmVJc7YBxzYEpuCHrf3dFtik1jjHQLM-1uCMrwaXkkMOalHvqYzfY0U7NGWma5vpCY6DnJvmIrU1T45vpQh1O34g97ePY2XZhxh4ttX1NP3Fho4_9nO7JbbBtwu1VN-T0-nI6HLPy4-39sC-zQeWQaWOkQwxM1sY5x5nNhXCBeVcXRhXBCOllcAZrKQQE5X3BuWegDGgNXIsNefqtHcb4NWOaqm5Zi21re4xzqgCM5rKAXC7Rx2t0dh3W1TA2nR0v1d8B4geGNVzN</recordid><startdate>20190825</startdate><enddate>20190825</enddate><creator>Zhao, Kechao</creator><creator>Wang, Xiaojun</creator><creator>Chen, Weiyi</creator><creator>He, Rui</creator><creator>Li, Xiaona</creator><creator>Gao, Yan</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>20190825</creationdate><title>A comparative study of viscoelasticity between normal cornea and keratoconus</title><author>Zhao, Kechao ; Wang, Xiaojun ; Chen, Weiyi ; He, Rui ; Li, Xiaona ; Gao, Yan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p562-8994beef04d9bbb10a633bf0cbd7957f934c4fb9ed4332f5cc711c02592882183</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>chi</language><creationdate>2019</creationdate><topic>Area Under Curve</topic><topic>Cornea - physiology</topic><topic>Elasticity</topic><topic>Humans</topic><topic>Keratoconus - pathology</topic><topic>ROC Curve</topic><topic>Viscosity</topic><toplevel>online_resources</toplevel><creatorcontrib>Zhao, Kechao</creatorcontrib><creatorcontrib>Wang, Xiaojun</creatorcontrib><creatorcontrib>Chen, Weiyi</creatorcontrib><creatorcontrib>He, Rui</creatorcontrib><creatorcontrib>Li, Xiaona</creatorcontrib><creatorcontrib>Gao, Yan</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Sheng wu yi xue gong cheng xue za zhi</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zhao, Kechao</au><au>Wang, Xiaojun</au><au>Chen, Weiyi</au><au>He, Rui</au><au>Li, Xiaona</au><au>Gao, Yan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A comparative study of viscoelasticity between normal cornea and keratoconus</atitle><jtitle>Sheng wu yi xue gong cheng xue za zhi</jtitle><addtitle>Sheng Wu Yi Xue Gong Cheng Xue Za Zhi</addtitle><date>2019-08-25</date><risdate>2019</risdate><volume>36</volume><issue>4</issue><spage>613</spage><pages>613-</pages><issn>1001-5515</issn><abstract>Study of the mechanical properties of in vivo corneal materials is an important basis for further study of corneal physiological and pathological phenomena by means of finite element method. In this paper, the elastic coefficient ( ) and viscous coefficient ( ) of normal cornea and keratoconus under pulse pressure are calculated by using standard linear solid model with the data provided by corneal visualization scheimpflug technology. The results showed that there was a significant difference of and between normal cornea and keratoconus cornea ( &lt; 0.05). Receiver operating characteristic curve analysis showed that the area under curve (AUC) for , and their combined indicators were 0.776, 0.895 and 0.948, respectively, which indicated that keratoconus could be predicted by and . The results of this study may provide a reference for the early diagnosis of keratoconus and avoid the occurrence of keratoconus after operation, so it has a certain clinical value.</abstract><cop>China</cop><pmid>31441262</pmid><doi>10.7507/1001-5515.201812052</doi></addata></record>
fulltext fulltext
identifier ISSN: 1001-5515
ispartof Sheng wu yi xue gong cheng xue za zhi, 2019-08, Vol.36 (4), p.613
issn 1001-5515
language chi
recordid cdi_proquest_miscellaneous_2298147264
source MEDLINE; PubMed Central
subjects Area Under Curve
Cornea - physiology
Elasticity
Humans
Keratoconus - pathology
ROC Curve
Viscosity
title A comparative study of viscoelasticity between normal cornea and keratoconus
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T16%3A19%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20comparative%20study%20of%20viscoelasticity%20between%20normal%20cornea%20and%20keratoconus&rft.jtitle=Sheng%20wu%20yi%20xue%20gong%20cheng%20xue%20za%20zhi&rft.au=Zhao,%20Kechao&rft.date=2019-08-25&rft.volume=36&rft.issue=4&rft.spage=613&rft.pages=613-&rft.issn=1001-5515&rft_id=info:doi/10.7507/1001-5515.201812052&rft_dat=%3Cproquest_pubme%3E2298147264%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2298147264&rft_id=info:pmid/31441262&rfr_iscdi=true