Determination of Deposition Order of Toners, Inkjet Inks, and Blue Ballpoint Pen Combining MeV-Secondary Ion Mass Spectrometry and Particle Induced X‑ray Emission

Determination of the deposition order of different writing tools is very important for the forensic investigation of questioned documents. Here we present a novel application of two ion beam analysis (IBA) techniques: secondary ion mass spectrometry using MeV ions (MeV-SIMS) and particle induced X-r...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical chemistry (Washington) 2019-10, Vol.91 (20), p.12997-13005
Hauptverfasser: Moore, Katherine Louise, Barac, Marko, Brajković, Marko, Bailey, Melanie Jane, Siketić, Zdravko, Bogdanović Radović, Iva
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 13005
container_issue 20
container_start_page 12997
container_title Analytical chemistry (Washington)
container_volume 91
creator Moore, Katherine Louise
Barac, Marko
Brajković, Marko
Bailey, Melanie Jane
Siketić, Zdravko
Bogdanović Radović, Iva
description Determination of the deposition order of different writing tools is very important for the forensic investigation of questioned documents. Here we present a novel application of two ion beam analysis (IBA) techniques: secondary ion mass spectrometry using MeV ions (MeV-SIMS) and particle induced X-ray emission (PIXE) to determine the deposition order of intersecting lines made of ballpoint pen ink, inkjet printer ink, and laser printer toners. MeV-SIMS is an emerging mass spectrometry technique where incident heavy MeV ions are used to desorb secondary molecular ions from the uppermost layers of an organic sample. In contrast, PIXE provides information about sample elemental composition through characteristic X-ray spectra coming from greater depth. In the case of PIXE, the information depth depends on incident ion energy, sample matrix and self-absorption of X-rays on the way out from the sample to the X-ray detector. The measurements were carried out using a heavy ion microprobe at the Ruđer Bošković Institute. Principal component analysis (PCA) was employed for image processing of the data. We will demonstrate that MeV-SIMS alone was successful to determine the deposition order of all intersections not involving inkjet printer ink. The fact that PIXE yields information from deeper layers was crucial to resolve cases where inkjet printer ink was included due to its adherence and penetration properties. This is the first time the different information depths of PIXE and MeV-SIMS have been exploited for a practical application. The use of both techniques, MeV-SIMS and PIXE, allowed the correct determination of deposition order for four out of six pairs of samples.
doi_str_mv 10.1021/acs.analchem.9b03058
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2293012499</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2293012499</sourcerecordid><originalsourceid>FETCH-LOGICAL-a459t-e52e4bc084628ceb78841e649756665ebb112481968abe07216974aed61790e83</originalsourceid><addsrcrecordid>eNp9kcFu1DAQhi0EokvhDRCyxIUD2Y4dx7GPdFvKSq1aqQVxixxnFrIkdrCTQ2-8Au_Ak_VJcNhtDz1wGs3om88j_4S8ZrBkwNmRsXFpnOnsd-yXuoYcCvWELFjBIZNK8adkAQB5xkuAA_Iixi0AY8Dkc3KQJ6rQTCzInxMcMfStM2PrHfUbeoKDj-2_7jI0GObZjXcY4nu6dj-2OM4lNcY19LibkB6brht860Z6hY6ufF-3rnXf6AV-ya7ReteYcEvXSXhhYqTXA9ox-B7HNJ0lVyaMre0weZvJYkO_3v36HcwtPe3bGNMhL8mzjekivtrXQ_L54-nN6lN2fnm2Xn04z4wo9JhhwVHUFpSQXFmsS6UEQyl0WUgpC6xrxrhQTEtlaoSSM6lLYbCRrNSAKj8k73beIfifE8axSgdY7Drj0E-x4lznkBRaJ_TtI3Trp5DiSFQOZa6UFEWixI6ywccYcFMNoe3Tb1QMqjnFKqVY3adY7VNMa2_28qnusXlYuo8tAbAD5vWHh__r_AuRU6zi</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2307388645</pqid></control><display><type>article</type><title>Determination of Deposition Order of Toners, Inkjet Inks, and Blue Ballpoint Pen Combining MeV-Secondary Ion Mass Spectrometry and Particle Induced X‑ray Emission</title><source>ACS Publications</source><creator>Moore, Katherine Louise ; Barac, Marko ; Brajković, Marko ; Bailey, Melanie Jane ; Siketić, Zdravko ; Bogdanović Radović, Iva</creator><creatorcontrib>Moore, Katherine Louise ; Barac, Marko ; Brajković, Marko ; Bailey, Melanie Jane ; Siketić, Zdravko ; Bogdanović Radović, Iva</creatorcontrib><description>Determination of the deposition order of different writing tools is very important for the forensic investigation of questioned documents. Here we present a novel application of two ion beam analysis (IBA) techniques: secondary ion mass spectrometry using MeV ions (MeV-SIMS) and particle induced X-ray emission (PIXE) to determine the deposition order of intersecting lines made of ballpoint pen ink, inkjet printer ink, and laser printer toners. MeV-SIMS is an emerging mass spectrometry technique where incident heavy MeV ions are used to desorb secondary molecular ions from the uppermost layers of an organic sample. In contrast, PIXE provides information about sample elemental composition through characteristic X-ray spectra coming from greater depth. In the case of PIXE, the information depth depends on incident ion energy, sample matrix and self-absorption of X-rays on the way out from the sample to the X-ray detector. The measurements were carried out using a heavy ion microprobe at the Ruđer Bošković Institute. Principal component analysis (PCA) was employed for image processing of the data. We will demonstrate that MeV-SIMS alone was successful to determine the deposition order of all intersections not involving inkjet printer ink. The fact that PIXE yields information from deeper layers was crucial to resolve cases where inkjet printer ink was included due to its adherence and penetration properties. This is the first time the different information depths of PIXE and MeV-SIMS have been exploited for a practical application. The use of both techniques, MeV-SIMS and PIXE, allowed the correct determination of deposition order for four out of six pairs of samples.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>DOI: 10.1021/acs.analchem.9b03058</identifier><identifier>PMID: 31525914</identifier><language>eng</language><publisher>United States: American Chemical Society</publisher><subject>Analytical chemistry ; Analytical techniques ; Case depth ; Chemical composition ; Chemistry ; Deposition ; Emission ; Emissions ; Forensic science ; Heavy ions ; Image processing ; Ink jet printers ; Inkjet printing ; Inks ; Ion beams ; Ions ; Line intersections ; Mass spectrometry ; Mass spectroscopy ; Molecular ions ; Principal components analysis ; Printers ; Printers (data processing) ; Scientific imaging ; Secondary ion mass spectrometry ; Spectroscopy ; Toners ; X ray detectors ; X ray spectra ; X-rays</subject><ispartof>Analytical chemistry (Washington), 2019-10, Vol.91 (20), p.12997-13005</ispartof><rights>Copyright American Chemical Society Oct 15, 2019</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a459t-e52e4bc084628ceb78841e649756665ebb112481968abe07216974aed61790e83</citedby><cites>FETCH-LOGICAL-a459t-e52e4bc084628ceb78841e649756665ebb112481968abe07216974aed61790e83</cites><orcidid>0000-0002-4100-736X ; 0000-0001-9050-7910</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://pubs.acs.org/doi/pdf/10.1021/acs.analchem.9b03058$$EPDF$$P50$$Gacs$$H</linktopdf><linktohtml>$$Uhttps://pubs.acs.org/doi/10.1021/acs.analchem.9b03058$$EHTML$$P50$$Gacs$$H</linktohtml><link.rule.ids>314,776,780,2752,27053,27901,27902,56713,56763</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31525914$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Moore, Katherine Louise</creatorcontrib><creatorcontrib>Barac, Marko</creatorcontrib><creatorcontrib>Brajković, Marko</creatorcontrib><creatorcontrib>Bailey, Melanie Jane</creatorcontrib><creatorcontrib>Siketić, Zdravko</creatorcontrib><creatorcontrib>Bogdanović Radović, Iva</creatorcontrib><title>Determination of Deposition Order of Toners, Inkjet Inks, and Blue Ballpoint Pen Combining MeV-Secondary Ion Mass Spectrometry and Particle Induced X‑ray Emission</title><title>Analytical chemistry (Washington)</title><addtitle>Anal. Chem</addtitle><description>Determination of the deposition order of different writing tools is very important for the forensic investigation of questioned documents. Here we present a novel application of two ion beam analysis (IBA) techniques: secondary ion mass spectrometry using MeV ions (MeV-SIMS) and particle induced X-ray emission (PIXE) to determine the deposition order of intersecting lines made of ballpoint pen ink, inkjet printer ink, and laser printer toners. MeV-SIMS is an emerging mass spectrometry technique where incident heavy MeV ions are used to desorb secondary molecular ions from the uppermost layers of an organic sample. In contrast, PIXE provides information about sample elemental composition through characteristic X-ray spectra coming from greater depth. In the case of PIXE, the information depth depends on incident ion energy, sample matrix and self-absorption of X-rays on the way out from the sample to the X-ray detector. The measurements were carried out using a heavy ion microprobe at the Ruđer Bošković Institute. Principal component analysis (PCA) was employed for image processing of the data. We will demonstrate that MeV-SIMS alone was successful to determine the deposition order of all intersections not involving inkjet printer ink. The fact that PIXE yields information from deeper layers was crucial to resolve cases where inkjet printer ink was included due to its adherence and penetration properties. This is the first time the different information depths of PIXE and MeV-SIMS have been exploited for a practical application. The use of both techniques, MeV-SIMS and PIXE, allowed the correct determination of deposition order for four out of six pairs of samples.</description><subject>Analytical chemistry</subject><subject>Analytical techniques</subject><subject>Case depth</subject><subject>Chemical composition</subject><subject>Chemistry</subject><subject>Deposition</subject><subject>Emission</subject><subject>Emissions</subject><subject>Forensic science</subject><subject>Heavy ions</subject><subject>Image processing</subject><subject>Ink jet printers</subject><subject>Inkjet printing</subject><subject>Inks</subject><subject>Ion beams</subject><subject>Ions</subject><subject>Line intersections</subject><subject>Mass spectrometry</subject><subject>Mass spectroscopy</subject><subject>Molecular ions</subject><subject>Principal components analysis</subject><subject>Printers</subject><subject>Printers (data processing)</subject><subject>Scientific imaging</subject><subject>Secondary ion mass spectrometry</subject><subject>Spectroscopy</subject><subject>Toners</subject><subject>X ray detectors</subject><subject>X ray spectra</subject><subject>X-rays</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp9kcFu1DAQhi0EokvhDRCyxIUD2Y4dx7GPdFvKSq1aqQVxixxnFrIkdrCTQ2-8Au_Ak_VJcNhtDz1wGs3om88j_4S8ZrBkwNmRsXFpnOnsd-yXuoYcCvWELFjBIZNK8adkAQB5xkuAA_Iixi0AY8Dkc3KQJ6rQTCzInxMcMfStM2PrHfUbeoKDj-2_7jI0GObZjXcY4nu6dj-2OM4lNcY19LibkB6brht860Z6hY6ufF-3rnXf6AV-ya7ReteYcEvXSXhhYqTXA9ox-B7HNJ0lVyaMre0weZvJYkO_3v36HcwtPe3bGNMhL8mzjekivtrXQ_L54-nN6lN2fnm2Xn04z4wo9JhhwVHUFpSQXFmsS6UEQyl0WUgpC6xrxrhQTEtlaoSSM6lLYbCRrNSAKj8k73beIfifE8axSgdY7Drj0E-x4lznkBRaJ_TtI3Trp5DiSFQOZa6UFEWixI6ywccYcFMNoe3Tb1QMqjnFKqVY3adY7VNMa2_28qnusXlYuo8tAbAD5vWHh__r_AuRU6zi</recordid><startdate>20191015</startdate><enddate>20191015</enddate><creator>Moore, Katherine Louise</creator><creator>Barac, Marko</creator><creator>Brajković, Marko</creator><creator>Bailey, Melanie Jane</creator><creator>Siketić, Zdravko</creator><creator>Bogdanović Radović, Iva</creator><general>American Chemical Society</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7TM</scope><scope>7U5</scope><scope>7U7</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-4100-736X</orcidid><orcidid>https://orcid.org/0000-0001-9050-7910</orcidid></search><sort><creationdate>20191015</creationdate><title>Determination of Deposition Order of Toners, Inkjet Inks, and Blue Ballpoint Pen Combining MeV-Secondary Ion Mass Spectrometry and Particle Induced X‑ray Emission</title><author>Moore, Katherine Louise ; Barac, Marko ; Brajković, Marko ; Bailey, Melanie Jane ; Siketić, Zdravko ; Bogdanović Radović, Iva</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a459t-e52e4bc084628ceb78841e649756665ebb112481968abe07216974aed61790e83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Analytical chemistry</topic><topic>Analytical techniques</topic><topic>Case depth</topic><topic>Chemical composition</topic><topic>Chemistry</topic><topic>Deposition</topic><topic>Emission</topic><topic>Emissions</topic><topic>Forensic science</topic><topic>Heavy ions</topic><topic>Image processing</topic><topic>Ink jet printers</topic><topic>Inkjet printing</topic><topic>Inks</topic><topic>Ion beams</topic><topic>Ions</topic><topic>Line intersections</topic><topic>Mass spectrometry</topic><topic>Mass spectroscopy</topic><topic>Molecular ions</topic><topic>Principal components analysis</topic><topic>Printers</topic><topic>Printers (data processing)</topic><topic>Scientific imaging</topic><topic>Secondary ion mass spectrometry</topic><topic>Spectroscopy</topic><topic>Toners</topic><topic>X ray detectors</topic><topic>X ray spectra</topic><topic>X-rays</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Moore, Katherine Louise</creatorcontrib><creatorcontrib>Barac, Marko</creatorcontrib><creatorcontrib>Brajković, Marko</creatorcontrib><creatorcontrib>Bailey, Melanie Jane</creatorcontrib><creatorcontrib>Siketić, Zdravko</creatorcontrib><creatorcontrib>Bogdanović Radović, Iva</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Moore, Katherine Louise</au><au>Barac, Marko</au><au>Brajković, Marko</au><au>Bailey, Melanie Jane</au><au>Siketić, Zdravko</au><au>Bogdanović Radović, Iva</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of Deposition Order of Toners, Inkjet Inks, and Blue Ballpoint Pen Combining MeV-Secondary Ion Mass Spectrometry and Particle Induced X‑ray Emission</atitle><jtitle>Analytical chemistry (Washington)</jtitle><addtitle>Anal. Chem</addtitle><date>2019-10-15</date><risdate>2019</risdate><volume>91</volume><issue>20</issue><spage>12997</spage><epage>13005</epage><pages>12997-13005</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><abstract>Determination of the deposition order of different writing tools is very important for the forensic investigation of questioned documents. Here we present a novel application of two ion beam analysis (IBA) techniques: secondary ion mass spectrometry using MeV ions (MeV-SIMS) and particle induced X-ray emission (PIXE) to determine the deposition order of intersecting lines made of ballpoint pen ink, inkjet printer ink, and laser printer toners. MeV-SIMS is an emerging mass spectrometry technique where incident heavy MeV ions are used to desorb secondary molecular ions from the uppermost layers of an organic sample. In contrast, PIXE provides information about sample elemental composition through characteristic X-ray spectra coming from greater depth. In the case of PIXE, the information depth depends on incident ion energy, sample matrix and self-absorption of X-rays on the way out from the sample to the X-ray detector. The measurements were carried out using a heavy ion microprobe at the Ruđer Bošković Institute. Principal component analysis (PCA) was employed for image processing of the data. We will demonstrate that MeV-SIMS alone was successful to determine the deposition order of all intersections not involving inkjet printer ink. The fact that PIXE yields information from deeper layers was crucial to resolve cases where inkjet printer ink was included due to its adherence and penetration properties. This is the first time the different information depths of PIXE and MeV-SIMS have been exploited for a practical application. The use of both techniques, MeV-SIMS and PIXE, allowed the correct determination of deposition order for four out of six pairs of samples.</abstract><cop>United States</cop><pub>American Chemical Society</pub><pmid>31525914</pmid><doi>10.1021/acs.analchem.9b03058</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0002-4100-736X</orcidid><orcidid>https://orcid.org/0000-0001-9050-7910</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0003-2700
ispartof Analytical chemistry (Washington), 2019-10, Vol.91 (20), p.12997-13005
issn 0003-2700
1520-6882
language eng
recordid cdi_proquest_miscellaneous_2293012499
source ACS Publications
subjects Analytical chemistry
Analytical techniques
Case depth
Chemical composition
Chemistry
Deposition
Emission
Emissions
Forensic science
Heavy ions
Image processing
Ink jet printers
Inkjet printing
Inks
Ion beams
Ions
Line intersections
Mass spectrometry
Mass spectroscopy
Molecular ions
Principal components analysis
Printers
Printers (data processing)
Scientific imaging
Secondary ion mass spectrometry
Spectroscopy
Toners
X ray detectors
X ray spectra
X-rays
title Determination of Deposition Order of Toners, Inkjet Inks, and Blue Ballpoint Pen Combining MeV-Secondary Ion Mass Spectrometry and Particle Induced X‑ray Emission
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T10%3A02%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20Deposition%20Order%20of%20Toners,%20Inkjet%20Inks,%20and%20Blue%20Ballpoint%20Pen%20Combining%20MeV-Secondary%20Ion%20Mass%20Spectrometry%20and%20Particle%20Induced%20X%E2%80%91ray%20Emission&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Moore,%20Katherine%20Louise&rft.date=2019-10-15&rft.volume=91&rft.issue=20&rft.spage=12997&rft.epage=13005&rft.pages=12997-13005&rft.issn=0003-2700&rft.eissn=1520-6882&rft_id=info:doi/10.1021/acs.analchem.9b03058&rft_dat=%3Cproquest_cross%3E2293012499%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2307388645&rft_id=info:pmid/31525914&rfr_iscdi=true