A Metamodeling Approach for Instant Severity Assessment and Uncertainty Quantification of Iliac Artery Stenoses
Two-dimensional (2D) or three-dimensional (3D) models of blood flow in stenosed arteries can be used to patient-specifically predict outcome metrics, thereby supporting the physicians in decision making processes. However, these models are time consuming which limits the feasibility of output uncert...
Gespeichert in:
Veröffentlicht in: | Journal of biomechanical engineering 2020-01, Vol.142 (1) |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 1 |
container_start_page | |
container_title | Journal of biomechanical engineering |
container_volume | 142 |
creator | Heinen, S. G. H. Gashi, K. van den Heuvel, D. A. F de Vries, J. P. P. M. van de Vosse, F. N. Delhaas, T. Huberts, W. |
description | Two-dimensional (2D) or three-dimensional (3D) models of blood flow in stenosed arteries can be used to patient-specifically predict outcome metrics, thereby supporting the physicians in decision making processes. However, these models are time consuming which limits the feasibility of output uncertainty quantification (UQ). Accurate surrogates (metamodels) might be the solution. In this study, we aim to demonstrate the feasibility of a generalized polynomial chaos expansion-based metamodel to predict a clinically relevant output metric and to quantify the output uncertainty. As an example, a metamodel was constructed from a recently developed 2D model that was shown to be able to estimate translesional pressure drops in iliac artery stenoses (−0.9 ± 12.7 mmHg, R2 = 0.81). The metamodel was constructed from a virtual database using the adaptive generalized polynomial chaos expansion (agPCE) method. The constructed metamodel was then applied to 25 stenosed iliac arteries to predict the patient-specific pressure drop and to perform UQ. Comparing predicted pressure drops of the metamodel and in vivo measured pressure drops, the mean bias (−0.2 ± 13.7 mmHg) and the coefficient of determination (R2 = 0.80) were as good as of the original 2D computational fluid dynamics (CFD) model. UQ results of the 2D and metamodel were comparable. Estimation of the uncertainty interval using the original 2D model took 14 days, whereas the result of the metamodel was instantly available. In conclusion, it is feasible to quantify the uncertainty of the output metric and perform sensitivity analysis (SA) instantly using a metamodel. Future studies should investigate the possibility to construct a metamodel of more complex problems. |
doi_str_mv | 10.1115/1.4044502 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2290898863</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2290898863</sourcerecordid><originalsourceid>FETCH-LOGICAL-a305t-c1d99935c50ccc298892f2a4f2eea67327dab3a2316bafa469fb34bde8a1d5d63</originalsourceid><addsrcrecordid>eNo9kE1r3DAQhkVpSTYfh54LRcf24FSjD691NCFtFlJKSXMWY1luFWxpK8mF_fdR2W1PAzPPvPA-hLwFdgMA6hPcSCalYvwV2YDiXdNpBa_JhoHsGrYVcE4ucn5mDKCT7IycC1AgtiA2JPb0qyu4xNHNPvyk_X6fItpfdIqJ7kIuGAp9dH9c8uVA-5xdzourOwwjfQrWpYI-1NP3tZJ-8haLj4HGie5mj5b2qbh0oI_FhVifr8ibCefsrk_zkjx9vvtxe988fPuyu-0fGhRMlcbCqLUWyipmreW66zSfOMqJO4ftVvDtiINALqAdcELZ6mkQchhdhzCqsRWX5MMxt9b5vbpczOKzdfOMwcU1G84162psKyr68YjaFHNObjL75BdMBwPM_PVrwJz8Vvb9KXYdFjf-J_8JrcC7I4BVk3mOawq1ptGqk5KLF9SYf4M</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2290898863</pqid></control><display><type>article</type><title>A Metamodeling Approach for Instant Severity Assessment and Uncertainty Quantification of Iliac Artery Stenoses</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><source>ASME Transactions Journals (Current)</source><creator>Heinen, S. G. H. ; Gashi, K. ; van den Heuvel, D. A. F ; de Vries, J. P. P. M. ; van de Vosse, F. N. ; Delhaas, T. ; Huberts, W.</creator><creatorcontrib>Heinen, S. G. H. ; Gashi, K. ; van den Heuvel, D. A. F ; de Vries, J. P. P. M. ; van de Vosse, F. N. ; Delhaas, T. ; Huberts, W.</creatorcontrib><description>Two-dimensional (2D) or three-dimensional (3D) models of blood flow in stenosed arteries can be used to patient-specifically predict outcome metrics, thereby supporting the physicians in decision making processes. However, these models are time consuming which limits the feasibility of output uncertainty quantification (UQ). Accurate surrogates (metamodels) might be the solution. In this study, we aim to demonstrate the feasibility of a generalized polynomial chaos expansion-based metamodel to predict a clinically relevant output metric and to quantify the output uncertainty. As an example, a metamodel was constructed from a recently developed 2D model that was shown to be able to estimate translesional pressure drops in iliac artery stenoses (−0.9 ± 12.7 mmHg, R2 = 0.81). The metamodel was constructed from a virtual database using the adaptive generalized polynomial chaos expansion (agPCE) method. The constructed metamodel was then applied to 25 stenosed iliac arteries to predict the patient-specific pressure drop and to perform UQ. Comparing predicted pressure drops of the metamodel and in vivo measured pressure drops, the mean bias (−0.2 ± 13.7 mmHg) and the coefficient of determination (R2 = 0.80) were as good as of the original 2D computational fluid dynamics (CFD) model. UQ results of the 2D and metamodel were comparable. Estimation of the uncertainty interval using the original 2D model took 14 days, whereas the result of the metamodel was instantly available. In conclusion, it is feasible to quantify the uncertainty of the output metric and perform sensitivity analysis (SA) instantly using a metamodel. Future studies should investigate the possibility to construct a metamodel of more complex problems.</description><identifier>ISSN: 0148-0731</identifier><identifier>ISSN: 1528-8951</identifier><identifier>EISSN: 1528-8951</identifier><identifier>DOI: 10.1115/1.4044502</identifier><identifier>PMID: 31513713</identifier><language>eng</language><publisher>United States: ASME</publisher><subject>Constriction, Pathologic - physiopathology ; Female ; Humans ; Iliac Artery - physiopathology ; Male ; Severity of Illness Index ; Uncertainty</subject><ispartof>Journal of biomechanical engineering, 2020-01, Vol.142 (1)</ispartof><rights>Copyright © 2020 by ASME.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a305t-c1d99935c50ccc298892f2a4f2eea67327dab3a2316bafa469fb34bde8a1d5d63</citedby><cites>FETCH-LOGICAL-a305t-c1d99935c50ccc298892f2a4f2eea67327dab3a2316bafa469fb34bde8a1d5d63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902,38497</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31513713$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Heinen, S. G. H.</creatorcontrib><creatorcontrib>Gashi, K.</creatorcontrib><creatorcontrib>van den Heuvel, D. A. F</creatorcontrib><creatorcontrib>de Vries, J. P. P. M.</creatorcontrib><creatorcontrib>van de Vosse, F. N.</creatorcontrib><creatorcontrib>Delhaas, T.</creatorcontrib><creatorcontrib>Huberts, W.</creatorcontrib><title>A Metamodeling Approach for Instant Severity Assessment and Uncertainty Quantification of Iliac Artery Stenoses</title><title>Journal of biomechanical engineering</title><addtitle>J Biomech Eng</addtitle><addtitle>J Biomech Eng</addtitle><description>Two-dimensional (2D) or three-dimensional (3D) models of blood flow in stenosed arteries can be used to patient-specifically predict outcome metrics, thereby supporting the physicians in decision making processes. However, these models are time consuming which limits the feasibility of output uncertainty quantification (UQ). Accurate surrogates (metamodels) might be the solution. In this study, we aim to demonstrate the feasibility of a generalized polynomial chaos expansion-based metamodel to predict a clinically relevant output metric and to quantify the output uncertainty. As an example, a metamodel was constructed from a recently developed 2D model that was shown to be able to estimate translesional pressure drops in iliac artery stenoses (−0.9 ± 12.7 mmHg, R2 = 0.81). The metamodel was constructed from a virtual database using the adaptive generalized polynomial chaos expansion (agPCE) method. The constructed metamodel was then applied to 25 stenosed iliac arteries to predict the patient-specific pressure drop and to perform UQ. Comparing predicted pressure drops of the metamodel and in vivo measured pressure drops, the mean bias (−0.2 ± 13.7 mmHg) and the coefficient of determination (R2 = 0.80) were as good as of the original 2D computational fluid dynamics (CFD) model. UQ results of the 2D and metamodel were comparable. Estimation of the uncertainty interval using the original 2D model took 14 days, whereas the result of the metamodel was instantly available. In conclusion, it is feasible to quantify the uncertainty of the output metric and perform sensitivity analysis (SA) instantly using a metamodel. Future studies should investigate the possibility to construct a metamodel of more complex problems.</description><subject>Constriction, Pathologic - physiopathology</subject><subject>Female</subject><subject>Humans</subject><subject>Iliac Artery - physiopathology</subject><subject>Male</subject><subject>Severity of Illness Index</subject><subject>Uncertainty</subject><issn>0148-0731</issn><issn>1528-8951</issn><issn>1528-8951</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kE1r3DAQhkVpSTYfh54LRcf24FSjD691NCFtFlJKSXMWY1luFWxpK8mF_fdR2W1PAzPPvPA-hLwFdgMA6hPcSCalYvwV2YDiXdNpBa_JhoHsGrYVcE4ucn5mDKCT7IycC1AgtiA2JPb0qyu4xNHNPvyk_X6fItpfdIqJ7kIuGAp9dH9c8uVA-5xdzourOwwjfQrWpYI-1NP3tZJ-8haLj4HGie5mj5b2qbh0oI_FhVifr8ibCefsrk_zkjx9vvtxe988fPuyu-0fGhRMlcbCqLUWyipmreW66zSfOMqJO4ftVvDtiINALqAdcELZ6mkQchhdhzCqsRWX5MMxt9b5vbpczOKzdfOMwcU1G84162psKyr68YjaFHNObjL75BdMBwPM_PVrwJz8Vvb9KXYdFjf-J_8JrcC7I4BVk3mOawq1ptGqk5KLF9SYf4M</recordid><startdate>20200101</startdate><enddate>20200101</enddate><creator>Heinen, S. G. H.</creator><creator>Gashi, K.</creator><creator>van den Heuvel, D. A. F</creator><creator>de Vries, J. P. P. M.</creator><creator>van de Vosse, F. N.</creator><creator>Delhaas, T.</creator><creator>Huberts, W.</creator><general>ASME</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20200101</creationdate><title>A Metamodeling Approach for Instant Severity Assessment and Uncertainty Quantification of Iliac Artery Stenoses</title><author>Heinen, S. G. H. ; Gashi, K. ; van den Heuvel, D. A. F ; de Vries, J. P. P. M. ; van de Vosse, F. N. ; Delhaas, T. ; Huberts, W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a305t-c1d99935c50ccc298892f2a4f2eea67327dab3a2316bafa469fb34bde8a1d5d63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Constriction, Pathologic - physiopathology</topic><topic>Female</topic><topic>Humans</topic><topic>Iliac Artery - physiopathology</topic><topic>Male</topic><topic>Severity of Illness Index</topic><topic>Uncertainty</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Heinen, S. G. H.</creatorcontrib><creatorcontrib>Gashi, K.</creatorcontrib><creatorcontrib>van den Heuvel, D. A. F</creatorcontrib><creatorcontrib>de Vries, J. P. P. M.</creatorcontrib><creatorcontrib>van de Vosse, F. N.</creatorcontrib><creatorcontrib>Delhaas, T.</creatorcontrib><creatorcontrib>Huberts, W.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of biomechanical engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Heinen, S. G. H.</au><au>Gashi, K.</au><au>van den Heuvel, D. A. F</au><au>de Vries, J. P. P. M.</au><au>van de Vosse, F. N.</au><au>Delhaas, T.</au><au>Huberts, W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Metamodeling Approach for Instant Severity Assessment and Uncertainty Quantification of Iliac Artery Stenoses</atitle><jtitle>Journal of biomechanical engineering</jtitle><stitle>J Biomech Eng</stitle><addtitle>J Biomech Eng</addtitle><date>2020-01-01</date><risdate>2020</risdate><volume>142</volume><issue>1</issue><issn>0148-0731</issn><issn>1528-8951</issn><eissn>1528-8951</eissn><abstract>Two-dimensional (2D) or three-dimensional (3D) models of blood flow in stenosed arteries can be used to patient-specifically predict outcome metrics, thereby supporting the physicians in decision making processes. However, these models are time consuming which limits the feasibility of output uncertainty quantification (UQ). Accurate surrogates (metamodels) might be the solution. In this study, we aim to demonstrate the feasibility of a generalized polynomial chaos expansion-based metamodel to predict a clinically relevant output metric and to quantify the output uncertainty. As an example, a metamodel was constructed from a recently developed 2D model that was shown to be able to estimate translesional pressure drops in iliac artery stenoses (−0.9 ± 12.7 mmHg, R2 = 0.81). The metamodel was constructed from a virtual database using the adaptive generalized polynomial chaos expansion (agPCE) method. The constructed metamodel was then applied to 25 stenosed iliac arteries to predict the patient-specific pressure drop and to perform UQ. Comparing predicted pressure drops of the metamodel and in vivo measured pressure drops, the mean bias (−0.2 ± 13.7 mmHg) and the coefficient of determination (R2 = 0.80) were as good as of the original 2D computational fluid dynamics (CFD) model. UQ results of the 2D and metamodel were comparable. Estimation of the uncertainty interval using the original 2D model took 14 days, whereas the result of the metamodel was instantly available. In conclusion, it is feasible to quantify the uncertainty of the output metric and perform sensitivity analysis (SA) instantly using a metamodel. Future studies should investigate the possibility to construct a metamodel of more complex problems.</abstract><cop>United States</cop><pub>ASME</pub><pmid>31513713</pmid><doi>10.1115/1.4044502</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0148-0731 |
ispartof | Journal of biomechanical engineering, 2020-01, Vol.142 (1) |
issn | 0148-0731 1528-8951 1528-8951 |
language | eng |
recordid | cdi_proquest_miscellaneous_2290898863 |
source | MEDLINE; Alma/SFX Local Collection; ASME Transactions Journals (Current) |
subjects | Constriction, Pathologic - physiopathology Female Humans Iliac Artery - physiopathology Male Severity of Illness Index Uncertainty |
title | A Metamodeling Approach for Instant Severity Assessment and Uncertainty Quantification of Iliac Artery Stenoses |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-20T20%3A07%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Metamodeling%20Approach%20for%20Instant%20Severity%20Assessment%20and%20Uncertainty%20Quantification%20of%20Iliac%20Artery%20Stenoses&rft.jtitle=Journal%20of%20biomechanical%20engineering&rft.au=Heinen,%20S.%20G.%20H.&rft.date=2020-01-01&rft.volume=142&rft.issue=1&rft.issn=0148-0731&rft.eissn=1528-8951&rft_id=info:doi/10.1115/1.4044502&rft_dat=%3Cproquest_cross%3E2290898863%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2290898863&rft_id=info:pmid/31513713&rfr_iscdi=true |