Impact of fluorescence on Raman remote sensing of temperature in natural water samples
A comprehensive investigation into the impact of spectral baseline on temperature prediction in natural marine water samples by Raman spectroscopy is presented. The origin of baseline signals is investigated using principal component analysis and phytoplankton cultures in laboratory experiments. Res...
Gespeichert in:
Veröffentlicht in: | Optics express 2019-08, Vol.27 (16), p.22339-22351 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 22351 |
---|---|
container_issue | 16 |
container_start_page | 22339 |
container_title | Optics express |
container_volume | 27 |
creator | de Lima Ribeiro, Andréa Artlett, Christopher Ajani, Penelope A Derkenne, Caro Pask, Helen |
description | A comprehensive investigation into the impact of spectral baseline on temperature prediction in natural marine water samples by Raman spectroscopy is presented. The origin of baseline signals is investigated using principal component analysis and phytoplankton cultures in laboratory experiments. Results indicate that fluorescence from photosynthetic pigments and dissolved organic matter may overlap with the Raman peak for 532 nm excitation and compromise the accuracy of temperature predictions. Two methods of spectral baseline correction in natural waters are evaluated: a traditional tilted baseline correction and a new correction by temperature marker values, with accuracies as high as ± 0.2°C being achieved in both cases. |
doi_str_mv | 10.1364/OE.27.022339 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2289573428</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2289573428</sourcerecordid><originalsourceid>FETCH-LOGICAL-c329t-907f6bce241601537913b90cdae4778ea6b4302651eaa08a87c45331c7ca39fd3</originalsourceid><addsrcrecordid>eNpNkM9LwzAYhoMoTqc3z5KjBzvzq01zlDF1MBiIeg1fs69SadKatIj_vRub4ul9Dw8vvA8hV5zNuCzU3XoxE3rGhJDSHJEzzozKFCv18b8-IecpfTDGlTb6lEwkzznLhTkjb0vfgxtoV9O6HbuIyWFwSLtAn8FDoBF9NyBNGFIT3nfcgL7HCMMYkTaBhl2Dln7BgJEm8H2L6YKc1NAmvDzklLw-LF7mT9lq_bic368yJ4UZMsN0XVQOheIF47nUhsvKMLcBVFqXCEWlJBNFzhGAlVBqp3IpudMOpKk3ckpu9rt97D5HTIP1zfZB20LAbkxWiNLkWipRbtHbPepil1LE2vax8RC_LWd2Z9KuF1Zouze5xa8Py2PlcfMH_6qTP3iEbf0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2289573428</pqid></control><display><type>article</type><title>Impact of fluorescence on Raman remote sensing of temperature in natural water samples</title><source>DOAJ Directory of Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><creator>de Lima Ribeiro, Andréa ; Artlett, Christopher ; Ajani, Penelope A ; Derkenne, Caro ; Pask, Helen</creator><creatorcontrib>de Lima Ribeiro, Andréa ; Artlett, Christopher ; Ajani, Penelope A ; Derkenne, Caro ; Pask, Helen</creatorcontrib><description>A comprehensive investigation into the impact of spectral baseline on temperature prediction in natural marine water samples by Raman spectroscopy is presented. The origin of baseline signals is investigated using principal component analysis and phytoplankton cultures in laboratory experiments. Results indicate that fluorescence from photosynthetic pigments and dissolved organic matter may overlap with the Raman peak for 532 nm excitation and compromise the accuracy of temperature predictions. Two methods of spectral baseline correction in natural waters are evaluated: a traditional tilted baseline correction and a new correction by temperature marker values, with accuracies as high as ± 0.2°C being achieved in both cases.</description><identifier>ISSN: 1094-4087</identifier><identifier>EISSN: 1094-4087</identifier><identifier>DOI: 10.1364/OE.27.022339</identifier><identifier>PMID: 31510529</identifier><language>eng</language><publisher>United States</publisher><ispartof>Optics express, 2019-08, Vol.27 (16), p.22339-22351</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c329t-907f6bce241601537913b90cdae4778ea6b4302651eaa08a87c45331c7ca39fd3</citedby><cites>FETCH-LOGICAL-c329t-907f6bce241601537913b90cdae4778ea6b4302651eaa08a87c45331c7ca39fd3</cites><orcidid>0000-0003-4578-8439</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,864,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31510529$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>de Lima Ribeiro, Andréa</creatorcontrib><creatorcontrib>Artlett, Christopher</creatorcontrib><creatorcontrib>Ajani, Penelope A</creatorcontrib><creatorcontrib>Derkenne, Caro</creatorcontrib><creatorcontrib>Pask, Helen</creatorcontrib><title>Impact of fluorescence on Raman remote sensing of temperature in natural water samples</title><title>Optics express</title><addtitle>Opt Express</addtitle><description>A comprehensive investigation into the impact of spectral baseline on temperature prediction in natural marine water samples by Raman spectroscopy is presented. The origin of baseline signals is investigated using principal component analysis and phytoplankton cultures in laboratory experiments. Results indicate that fluorescence from photosynthetic pigments and dissolved organic matter may overlap with the Raman peak for 532 nm excitation and compromise the accuracy of temperature predictions. Two methods of spectral baseline correction in natural waters are evaluated: a traditional tilted baseline correction and a new correction by temperature marker values, with accuracies as high as ± 0.2°C being achieved in both cases.</description><issn>1094-4087</issn><issn>1094-4087</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNpNkM9LwzAYhoMoTqc3z5KjBzvzq01zlDF1MBiIeg1fs69SadKatIj_vRub4ul9Dw8vvA8hV5zNuCzU3XoxE3rGhJDSHJEzzozKFCv18b8-IecpfTDGlTb6lEwkzznLhTkjb0vfgxtoV9O6HbuIyWFwSLtAn8FDoBF9NyBNGFIT3nfcgL7HCMMYkTaBhl2Dln7BgJEm8H2L6YKc1NAmvDzklLw-LF7mT9lq_bic368yJ4UZMsN0XVQOheIF47nUhsvKMLcBVFqXCEWlJBNFzhGAlVBqp3IpudMOpKk3ckpu9rt97D5HTIP1zfZB20LAbkxWiNLkWipRbtHbPepil1LE2vax8RC_LWd2Z9KuF1Zouze5xa8Py2PlcfMH_6qTP3iEbf0</recordid><startdate>20190805</startdate><enddate>20190805</enddate><creator>de Lima Ribeiro, Andréa</creator><creator>Artlett, Christopher</creator><creator>Ajani, Penelope A</creator><creator>Derkenne, Caro</creator><creator>Pask, Helen</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-4578-8439</orcidid></search><sort><creationdate>20190805</creationdate><title>Impact of fluorescence on Raman remote sensing of temperature in natural water samples</title><author>de Lima Ribeiro, Andréa ; Artlett, Christopher ; Ajani, Penelope A ; Derkenne, Caro ; Pask, Helen</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c329t-907f6bce241601537913b90cdae4778ea6b4302651eaa08a87c45331c7ca39fd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>de Lima Ribeiro, Andréa</creatorcontrib><creatorcontrib>Artlett, Christopher</creatorcontrib><creatorcontrib>Ajani, Penelope A</creatorcontrib><creatorcontrib>Derkenne, Caro</creatorcontrib><creatorcontrib>Pask, Helen</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Optics express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>de Lima Ribeiro, Andréa</au><au>Artlett, Christopher</au><au>Ajani, Penelope A</au><au>Derkenne, Caro</au><au>Pask, Helen</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Impact of fluorescence on Raman remote sensing of temperature in natural water samples</atitle><jtitle>Optics express</jtitle><addtitle>Opt Express</addtitle><date>2019-08-05</date><risdate>2019</risdate><volume>27</volume><issue>16</issue><spage>22339</spage><epage>22351</epage><pages>22339-22351</pages><issn>1094-4087</issn><eissn>1094-4087</eissn><abstract>A comprehensive investigation into the impact of spectral baseline on temperature prediction in natural marine water samples by Raman spectroscopy is presented. The origin of baseline signals is investigated using principal component analysis and phytoplankton cultures in laboratory experiments. Results indicate that fluorescence from photosynthetic pigments and dissolved organic matter may overlap with the Raman peak for 532 nm excitation and compromise the accuracy of temperature predictions. Two methods of spectral baseline correction in natural waters are evaluated: a traditional tilted baseline correction and a new correction by temperature marker values, with accuracies as high as ± 0.2°C being achieved in both cases.</abstract><cop>United States</cop><pmid>31510529</pmid><doi>10.1364/OE.27.022339</doi><tpages>13</tpages><orcidid>https://orcid.org/0000-0003-4578-8439</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1094-4087 |
ispartof | Optics express, 2019-08, Vol.27 (16), p.22339-22351 |
issn | 1094-4087 1094-4087 |
language | eng |
recordid | cdi_proquest_miscellaneous_2289573428 |
source | DOAJ Directory of Open Access Journals; EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection |
title | Impact of fluorescence on Raman remote sensing of temperature in natural water samples |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T05%3A45%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Impact%20of%20fluorescence%20on%20Raman%20remote%20sensing%20of%20temperature%20in%20natural%20water%20samples&rft.jtitle=Optics%20express&rft.au=de%20Lima%20Ribeiro,%20Andr%C3%A9a&rft.date=2019-08-05&rft.volume=27&rft.issue=16&rft.spage=22339&rft.epage=22351&rft.pages=22339-22351&rft.issn=1094-4087&rft.eissn=1094-4087&rft_id=info:doi/10.1364/OE.27.022339&rft_dat=%3Cproquest_cross%3E2289573428%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2289573428&rft_id=info:pmid/31510529&rfr_iscdi=true |