On the influence of rotational motion on MRI velocimetry of granular flows – Theoretical predictions and comparison to experimental data
[Display omitted] •Spinning granules amplify velocity variance measured by MRI.•Theoretical model derived to relate granule rotation to MRI signal.•Rotational velocity variance determined for simulated MRI of granular shear flow.•New model improves consistency with experimental data. Continuum dynam...
Gespeichert in:
Veröffentlicht in: | Journal of magnetic resonance (1997) 2019-10, Vol.307, p.106569-106569, Article 106569 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | [Display omitted]
•Spinning granules amplify velocity variance measured by MRI.•Theoretical model derived to relate granule rotation to MRI signal.•Rotational velocity variance determined for simulated MRI of granular shear flow.•New model improves consistency with experimental data.
Continuum dynamics of granular materials are known to be influenced by rotational, as well as translational, motion. Few experimental techniques exist that are sensitive to rotational motion. Here we demonstrate that MRI is sensitive to the rotation of granules and that we can quantify its effect on the MRI signal. In order to demonstrate the importance of rotational motion, we perform discrete element method (DEM) simulations of spherical particles inside a Couette shear cell. The variance of the velocity distribution was determined from DEM data using two approaches. (1) Direct averaging of the individual particle velocities. (2) Numerical simulation of the pulsed field gradient (PFG) MRI signal acquisition based on the DEM data. Rotational motion is found to be a significant effect, typically contributing up to 50% of the signal attenuation, thus amplifying the calculated velocity variance. A theoretical model was derived to relate an MRI signal to the angular velocity distribution. This model for the signal was compared to previously published experimental data as well as simulated MRI results and found to be consistent. |
---|---|
ISSN: | 1090-7807 1096-0856 |
DOI: | 10.1016/j.jmr.2019.106569 |