Selection of design parameters for closed-circuit forced-circulation solar heating systems

A system effectiveness, determined only by the physical characteristics, is defined for a closed-circuit forced-circulation solar heating system. Conditions leading to high values of the effectiveness are identified and simple methods developed for the selection of design parameters giving a specifi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Solar energy 1975, Vol.17 (6), p.331-333
1. Verfasser: Brinkworth, B.J.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 333
container_issue 6
container_start_page 331
container_title Solar energy
container_volume 17
creator Brinkworth, B.J.
description A system effectiveness, determined only by the physical characteristics, is defined for a closed-circuit forced-circulation solar heating system. Conditions leading to high values of the effectiveness are identified and simple methods developed for the selection of design parameters giving a specified performance.
doi_str_mv 10.1016/0038-092X(75)90033-X
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_22467747</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0038092X7590033X</els_id><sourcerecordid>22467747</sourcerecordid><originalsourceid>FETCH-LOGICAL-c335t-59f38e0fc45d87aa048967a26de3a06189d1b2f617a76e8b39d0265e6d78a34c3</originalsourceid><addsrcrecordid>eNp9kE9LxDAUxIMouK5-Aw89iR6qSdMm6UWQxX-w4EGFxUvIJq9rpG3WvFbYb2-7qx49PeYxMzA_Qk4ZvWSUiStKuUppmS3OZXFRDoqniz0yYblkKcsKuU8mf5ZDcoT4QSmTTMkJeXuGGmznQ5uEKnGAftUmaxNNAx1ETKoQE1sHBJdaH23vu_Flf2VttlEMtYnJOwyqXSW4wQ4aPCYHlakRTn7ulLze3b7MHtL50_3j7GaeWs6LLi3Kiiuglc0Lp6QxNFelkCYTDrihgqnSsWVWCSaNFKCWvHQ0EwUIJ5XhueVTcrbrXcfw2QN2uvFooa5NC6FHnWW5kDKXgzHfGW0MiBEqvY6-MXGjGdUjSD1S0iMlLQu9BakXQ-x6F4NhxJeHqNF6aAcGPg7otAv-_4Jv_RN8Hg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>22467747</pqid></control><display><type>article</type><title>Selection of design parameters for closed-circuit forced-circulation solar heating systems</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Brinkworth, B.J.</creator><creatorcontrib>Brinkworth, B.J.</creatorcontrib><description>A system effectiveness, determined only by the physical characteristics, is defined for a closed-circuit forced-circulation solar heating system. Conditions leading to high values of the effectiveness are identified and simple methods developed for the selection of design parameters giving a specified performance.</description><identifier>ISSN: 0038-092X</identifier><identifier>EISSN: 1471-1257</identifier><identifier>DOI: 10.1016/0038-092X(75)90033-X</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><ispartof>Solar energy, 1975, Vol.17 (6), p.331-333</ispartof><rights>1975</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c335t-59f38e0fc45d87aa048967a26de3a06189d1b2f617a76e8b39d0265e6d78a34c3</citedby><cites>FETCH-LOGICAL-c335t-59f38e0fc45d87aa048967a26de3a06189d1b2f617a76e8b39d0265e6d78a34c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/0038-092X(75)90033-X$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3548,4021,27921,27922,27923,45993</link.rule.ids></links><search><creatorcontrib>Brinkworth, B.J.</creatorcontrib><title>Selection of design parameters for closed-circuit forced-circulation solar heating systems</title><title>Solar energy</title><description>A system effectiveness, determined only by the physical characteristics, is defined for a closed-circuit forced-circulation solar heating system. Conditions leading to high values of the effectiveness are identified and simple methods developed for the selection of design parameters giving a specified performance.</description><issn>0038-092X</issn><issn>1471-1257</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1975</creationdate><recordtype>article</recordtype><recordid>eNp9kE9LxDAUxIMouK5-Aw89iR6qSdMm6UWQxX-w4EGFxUvIJq9rpG3WvFbYb2-7qx49PeYxMzA_Qk4ZvWSUiStKuUppmS3OZXFRDoqniz0yYblkKcsKuU8mf5ZDcoT4QSmTTMkJeXuGGmznQ5uEKnGAftUmaxNNAx1ETKoQE1sHBJdaH23vu_Flf2VttlEMtYnJOwyqXSW4wQ4aPCYHlakRTn7ulLze3b7MHtL50_3j7GaeWs6LLi3Kiiuglc0Lp6QxNFelkCYTDrihgqnSsWVWCSaNFKCWvHQ0EwUIJ5XhueVTcrbrXcfw2QN2uvFooa5NC6FHnWW5kDKXgzHfGW0MiBEqvY6-MXGjGdUjSD1S0iMlLQu9BakXQ-x6F4NhxJeHqNF6aAcGPg7otAv-_4Jv_RN8Hg</recordid><startdate>1975</startdate><enddate>1975</enddate><creator>Brinkworth, B.J.</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>1975</creationdate><title>Selection of design parameters for closed-circuit forced-circulation solar heating systems</title><author>Brinkworth, B.J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c335t-59f38e0fc45d87aa048967a26de3a06189d1b2f617a76e8b39d0265e6d78a34c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1975</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Brinkworth, B.J.</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Solar energy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Brinkworth, B.J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Selection of design parameters for closed-circuit forced-circulation solar heating systems</atitle><jtitle>Solar energy</jtitle><date>1975</date><risdate>1975</risdate><volume>17</volume><issue>6</issue><spage>331</spage><epage>333</epage><pages>331-333</pages><issn>0038-092X</issn><eissn>1471-1257</eissn><abstract>A system effectiveness, determined only by the physical characteristics, is defined for a closed-circuit forced-circulation solar heating system. Conditions leading to high values of the effectiveness are identified and simple methods developed for the selection of design parameters giving a specified performance.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/0038-092X(75)90033-X</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0038-092X
ispartof Solar energy, 1975, Vol.17 (6), p.331-333
issn 0038-092X
1471-1257
language eng
recordid cdi_proquest_miscellaneous_22467747
source Elsevier ScienceDirect Journals Complete
title Selection of design parameters for closed-circuit forced-circulation solar heating systems
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T17%3A14%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Selection%20of%20design%20parameters%20for%20closed-circuit%20forced-circulation%20solar%20heating%20systems&rft.jtitle=Solar%20energy&rft.au=Brinkworth,%20B.J.&rft.date=1975&rft.volume=17&rft.issue=6&rft.spage=331&rft.epage=333&rft.pages=331-333&rft.issn=0038-092X&rft.eissn=1471-1257&rft_id=info:doi/10.1016/0038-092X(75)90033-X&rft_dat=%3Cproquest_cross%3E22467747%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=22467747&rft_id=info:pmid/&rft_els_id=0038092X7590033X&rfr_iscdi=true