A sensitive label-free impedimetric DNA biosensor based on silsesquioxane-functionalized gold nanoparticles for Zika Virus detection
Zika virus (ZIKV) has recently become a global health challenge due to its rapid geographical expansion, since it is associated with serious neurological anomalies such as Guillain-Barré syndrome and microcephaly. Currently, the techniques for ZIKV diagnosis require labor-intensive, expensive and le...
Gespeichert in:
Veröffentlicht in: | Biosensors & bioelectronics 2019-09, Vol.141, p.111351-111351, Article 111351 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Zika virus (ZIKV) has recently become a global health challenge due to its rapid geographical expansion, since it is associated with serious neurological anomalies such as Guillain-Barré syndrome and microcephaly. Currently, the techniques for ZIKV diagnosis require labor-intensive, expensive and lengthy tests using sophisticated equipment. Moreover, false-positive or false-negative results can occur. In the present work, a DNA biosensor to detect ZIKV in real human serum samples was developed using an oxidized glassy carbon electrode (ox-GCE) modified with silsesquioxane-functionalized gold nanoparticles (AuNPs-SiPy). This nanohybrid was characterized by UV-Vis, FTIR and Raman spectroscopies, DLS, and XRD. The conditions for the immobilization of a ZIKV ssDNA probe on the electrode surface (ox-GCE-[AuNPs-SiPy]) were optimized by univariate and multivariate analysis. The optimized biosensor was characterized by CV, EIS and AFM experiments. The ZIKV target recognition was based on the variation of the charge transfer resistance (ΔRct) of the redox marker ([Fe(CN)6]3-/4-) used and the roughness (Rq) of the electrode surface. The proposed biosensor presented a LOD of 0.82 pmol L-1, with a linear range of 1.0 x10-12 – 1.0 x10-6 mol L-1. Moreover, the reported device showed a suitable stability and satisfactory sensitivity and selectivity to quantify ZIKV in human serum samples, which suggests its promising clinical applications for the early diagnosis of ZIKV-associated pathologies.
[Display omitted]
•DNA biosensor based on silsesquioxane-functionalized gold nanoparticles was prepared.•Positive charged polyelectrolyte was immobilized on oxidized-GCE for interaction of thiolated DNA probe.•Zika Virus (ZIKV) was detected using a sensitive label-free impedimetric DNA biosensor.•DNA biosensor presents suitable stability and selectivity to quantify ZIKV in serum samples. |
---|---|
ISSN: | 0956-5663 1873-4235 |
DOI: | 10.1016/j.bios.2019.111351 |