Integrated microfluidic pneumatic circuit for point-of-care molecular diagnostics

Developing simple, portable, rapid, and easy-to-use diagnostic technologies is essential for point-of-care (POC) blood molecular testing. Integrated microfluidic devices that include the functionalities of blood separation, microfluidic pumping, and molecular detection are desirable for POC testing;...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biosensors & bioelectronics 2019-05, Vol.133, p.169-176
Hauptverfasser: Shin, Suyeon, Kim, Byeongyeon, Kim, Yoon-Jin, Choi, Sungyoung
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 176
container_issue
container_start_page 169
container_title Biosensors & bioelectronics
container_volume 133
creator Shin, Suyeon
Kim, Byeongyeon
Kim, Yoon-Jin
Choi, Sungyoung
description Developing simple, portable, rapid, and easy-to-use diagnostic technologies is essential for point-of-care (POC) blood molecular testing. Integrated microfluidic devices that include the functionalities of blood separation, microfluidic pumping, and molecular detection are desirable for POC testing; however, current technologies still rely on off-chip sample processing or require bulky equipment. We report a fully-integrated microfluidic diagnostic device, i.e., an integrated pneumatic microfluidic circuit (iPC), that can autonomously pump whole blood, continuously sort blood plasma, and readily enable blood plasma proteomic analysis. The iPC contains vacuum pillars as a vacuum source and waste reservoir, as well as microchannels connecting the pillars as a plasma separator or a flow stabilizer. We combined the iPC and a miniaturized fluorescence microscope to create a portable diagnostic platform that enables fluorescence-based biomarker detection. First, we performed systematic parametric studies to establish design rules for determining the transport and distribution of fluid streams in the iPC. We then demonstrated the capability of the iPC-based diagnostic platform by successfully separating blood plasma from microliter quantities of whole blood while simultaneously quantifying thrombin in blood samples using an aptamer beacon within 5 min of sample injection. Our platform holds potential as a rapid, field-deployable, essentially universal diagnostic tool in POC settings. •Integrated microfluidic pneumatic circuit for autonomous aptamer-based molecular detection.•Establishment of the design rules for the fluid transport and distribution in a vacuum-driven pneumatic channel circuit.•High-purity blood plasma separation using the integrated microfluidic pneumatic circuit.•In-situ thrombin detection from blood samples using the integrated microfluidic pneumatic circuit.
doi_str_mv 10.1016/j.bios.2019.03.018
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2221036854</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0956566319302210</els_id><sourcerecordid>2201709860</sourcerecordid><originalsourceid>FETCH-LOGICAL-c426t-a5e59a7e9227262c0ca6459fd30f52c8cc5633562fe649f737194dc1c4f003733</originalsourceid><addsrcrecordid>eNqNkE1r3TAQRUVoSF4-_kAWxctu7I4kS7agmxKSNBAogWQtlPEo6GFbr5Jd6L-PHi_tsmQ1d3HuZTiMXXFoOHD9ddu8hJgbAdw0IBvg_RHb8L6TdSuk-sQ2YJSuldbylJ3lvAWAjhs4YacSjCic2rDH-3mh1-QWGqopYIp-XMMQsNrNtE5uKQlDwjUslY-p2sUwL3X0NbpE1RRHwnV0qRqCe51jLni-YMfejZku3-85e769ebr-UT_8vLu__v5QYyv0UjtFyriOjBCd0AIBnW6V8YMErwT2iEpLqbTwpFvjO1lebwfk2HoA2Ul5zr4cdncp_lopL3YKGWkc3UxxzVYIwUHqXrUfQIF3YHoNBRUHtKjIOZG3uxQml_5YDnZv3W7t3rrdW7cgbbFeSp_f99eXiYZ_lb-aC_DtAFAR8jtQshkDzUhDSISLHWL43_4bgzGTAg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2201709860</pqid></control><display><type>article</type><title>Integrated microfluidic pneumatic circuit for point-of-care molecular diagnostics</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Shin, Suyeon ; Kim, Byeongyeon ; Kim, Yoon-Jin ; Choi, Sungyoung</creator><creatorcontrib>Shin, Suyeon ; Kim, Byeongyeon ; Kim, Yoon-Jin ; Choi, Sungyoung</creatorcontrib><description>Developing simple, portable, rapid, and easy-to-use diagnostic technologies is essential for point-of-care (POC) blood molecular testing. Integrated microfluidic devices that include the functionalities of blood separation, microfluidic pumping, and molecular detection are desirable for POC testing; however, current technologies still rely on off-chip sample processing or require bulky equipment. We report a fully-integrated microfluidic diagnostic device, i.e., an integrated pneumatic microfluidic circuit (iPC), that can autonomously pump whole blood, continuously sort blood plasma, and readily enable blood plasma proteomic analysis. The iPC contains vacuum pillars as a vacuum source and waste reservoir, as well as microchannels connecting the pillars as a plasma separator or a flow stabilizer. We combined the iPC and a miniaturized fluorescence microscope to create a portable diagnostic platform that enables fluorescence-based biomarker detection. First, we performed systematic parametric studies to establish design rules for determining the transport and distribution of fluid streams in the iPC. We then demonstrated the capability of the iPC-based diagnostic platform by successfully separating blood plasma from microliter quantities of whole blood while simultaneously quantifying thrombin in blood samples using an aptamer beacon within 5 min of sample injection. Our platform holds potential as a rapid, field-deployable, essentially universal diagnostic tool in POC settings. •Integrated microfluidic pneumatic circuit for autonomous aptamer-based molecular detection.•Establishment of the design rules for the fluid transport and distribution in a vacuum-driven pneumatic channel circuit.•High-purity blood plasma separation using the integrated microfluidic pneumatic circuit.•In-situ thrombin detection from blood samples using the integrated microfluidic pneumatic circuit.</description><identifier>ISSN: 0956-5663</identifier><identifier>EISSN: 1873-4235</identifier><identifier>DOI: 10.1016/j.bios.2019.03.018</identifier><identifier>PMID: 30928735</identifier><language>eng</language><publisher>England: Elsevier B.V</publisher><subject>Aptamer beacon ; biomarkers ; biosensors ; blood plasma ; diagnostic techniques ; fluorescence microscopes ; Microfluidic pneumatic circuit ; oligonucleotides ; Plasma separation ; point-of-care systems ; proteomics ; stabilizers ; Thrombin ; Vacuum pillar</subject><ispartof>Biosensors &amp; bioelectronics, 2019-05, Vol.133, p.169-176</ispartof><rights>2019 Elsevier B.V.</rights><rights>Copyright © 2019 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c426t-a5e59a7e9227262c0ca6459fd30f52c8cc5633562fe649f737194dc1c4f003733</citedby><cites>FETCH-LOGICAL-c426t-a5e59a7e9227262c0ca6459fd30f52c8cc5633562fe649f737194dc1c4f003733</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0956566319302210$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30928735$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Shin, Suyeon</creatorcontrib><creatorcontrib>Kim, Byeongyeon</creatorcontrib><creatorcontrib>Kim, Yoon-Jin</creatorcontrib><creatorcontrib>Choi, Sungyoung</creatorcontrib><title>Integrated microfluidic pneumatic circuit for point-of-care molecular diagnostics</title><title>Biosensors &amp; bioelectronics</title><addtitle>Biosens Bioelectron</addtitle><description>Developing simple, portable, rapid, and easy-to-use diagnostic technologies is essential for point-of-care (POC) blood molecular testing. Integrated microfluidic devices that include the functionalities of blood separation, microfluidic pumping, and molecular detection are desirable for POC testing; however, current technologies still rely on off-chip sample processing or require bulky equipment. We report a fully-integrated microfluidic diagnostic device, i.e., an integrated pneumatic microfluidic circuit (iPC), that can autonomously pump whole blood, continuously sort blood plasma, and readily enable blood plasma proteomic analysis. The iPC contains vacuum pillars as a vacuum source and waste reservoir, as well as microchannels connecting the pillars as a plasma separator or a flow stabilizer. We combined the iPC and a miniaturized fluorescence microscope to create a portable diagnostic platform that enables fluorescence-based biomarker detection. First, we performed systematic parametric studies to establish design rules for determining the transport and distribution of fluid streams in the iPC. We then demonstrated the capability of the iPC-based diagnostic platform by successfully separating blood plasma from microliter quantities of whole blood while simultaneously quantifying thrombin in blood samples using an aptamer beacon within 5 min of sample injection. Our platform holds potential as a rapid, field-deployable, essentially universal diagnostic tool in POC settings. •Integrated microfluidic pneumatic circuit for autonomous aptamer-based molecular detection.•Establishment of the design rules for the fluid transport and distribution in a vacuum-driven pneumatic channel circuit.•High-purity blood plasma separation using the integrated microfluidic pneumatic circuit.•In-situ thrombin detection from blood samples using the integrated microfluidic pneumatic circuit.</description><subject>Aptamer beacon</subject><subject>biomarkers</subject><subject>biosensors</subject><subject>blood plasma</subject><subject>diagnostic techniques</subject><subject>fluorescence microscopes</subject><subject>Microfluidic pneumatic circuit</subject><subject>oligonucleotides</subject><subject>Plasma separation</subject><subject>point-of-care systems</subject><subject>proteomics</subject><subject>stabilizers</subject><subject>Thrombin</subject><subject>Vacuum pillar</subject><issn>0956-5663</issn><issn>1873-4235</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNqNkE1r3TAQRUVoSF4-_kAWxctu7I4kS7agmxKSNBAogWQtlPEo6GFbr5Jd6L-PHi_tsmQ1d3HuZTiMXXFoOHD9ddu8hJgbAdw0IBvg_RHb8L6TdSuk-sQ2YJSuldbylJ3lvAWAjhs4YacSjCic2rDH-3mh1-QWGqopYIp-XMMQsNrNtE5uKQlDwjUslY-p2sUwL3X0NbpE1RRHwnV0qRqCe51jLni-YMfejZku3-85e769ebr-UT_8vLu__v5QYyv0UjtFyriOjBCd0AIBnW6V8YMErwT2iEpLqbTwpFvjO1lebwfk2HoA2Ul5zr4cdncp_lopL3YKGWkc3UxxzVYIwUHqXrUfQIF3YHoNBRUHtKjIOZG3uxQml_5YDnZv3W7t3rrdW7cgbbFeSp_f99eXiYZ_lb-aC_DtAFAR8jtQshkDzUhDSISLHWL43_4bgzGTAg</recordid><startdate>20190515</startdate><enddate>20190515</enddate><creator>Shin, Suyeon</creator><creator>Kim, Byeongyeon</creator><creator>Kim, Yoon-Jin</creator><creator>Choi, Sungyoung</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7S9</scope><scope>L.6</scope></search><sort><creationdate>20190515</creationdate><title>Integrated microfluidic pneumatic circuit for point-of-care molecular diagnostics</title><author>Shin, Suyeon ; Kim, Byeongyeon ; Kim, Yoon-Jin ; Choi, Sungyoung</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c426t-a5e59a7e9227262c0ca6459fd30f52c8cc5633562fe649f737194dc1c4f003733</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Aptamer beacon</topic><topic>biomarkers</topic><topic>biosensors</topic><topic>blood plasma</topic><topic>diagnostic techniques</topic><topic>fluorescence microscopes</topic><topic>Microfluidic pneumatic circuit</topic><topic>oligonucleotides</topic><topic>Plasma separation</topic><topic>point-of-care systems</topic><topic>proteomics</topic><topic>stabilizers</topic><topic>Thrombin</topic><topic>Vacuum pillar</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shin, Suyeon</creatorcontrib><creatorcontrib>Kim, Byeongyeon</creatorcontrib><creatorcontrib>Kim, Yoon-Jin</creatorcontrib><creatorcontrib>Choi, Sungyoung</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>AGRICOLA</collection><collection>AGRICOLA - Academic</collection><jtitle>Biosensors &amp; bioelectronics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shin, Suyeon</au><au>Kim, Byeongyeon</au><au>Kim, Yoon-Jin</au><au>Choi, Sungyoung</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Integrated microfluidic pneumatic circuit for point-of-care molecular diagnostics</atitle><jtitle>Biosensors &amp; bioelectronics</jtitle><addtitle>Biosens Bioelectron</addtitle><date>2019-05-15</date><risdate>2019</risdate><volume>133</volume><spage>169</spage><epage>176</epage><pages>169-176</pages><issn>0956-5663</issn><eissn>1873-4235</eissn><abstract>Developing simple, portable, rapid, and easy-to-use diagnostic technologies is essential for point-of-care (POC) blood molecular testing. Integrated microfluidic devices that include the functionalities of blood separation, microfluidic pumping, and molecular detection are desirable for POC testing; however, current technologies still rely on off-chip sample processing or require bulky equipment. We report a fully-integrated microfluidic diagnostic device, i.e., an integrated pneumatic microfluidic circuit (iPC), that can autonomously pump whole blood, continuously sort blood plasma, and readily enable blood plasma proteomic analysis. The iPC contains vacuum pillars as a vacuum source and waste reservoir, as well as microchannels connecting the pillars as a plasma separator or a flow stabilizer. We combined the iPC and a miniaturized fluorescence microscope to create a portable diagnostic platform that enables fluorescence-based biomarker detection. First, we performed systematic parametric studies to establish design rules for determining the transport and distribution of fluid streams in the iPC. We then demonstrated the capability of the iPC-based diagnostic platform by successfully separating blood plasma from microliter quantities of whole blood while simultaneously quantifying thrombin in blood samples using an aptamer beacon within 5 min of sample injection. Our platform holds potential as a rapid, field-deployable, essentially universal diagnostic tool in POC settings. •Integrated microfluidic pneumatic circuit for autonomous aptamer-based molecular detection.•Establishment of the design rules for the fluid transport and distribution in a vacuum-driven pneumatic channel circuit.•High-purity blood plasma separation using the integrated microfluidic pneumatic circuit.•In-situ thrombin detection from blood samples using the integrated microfluidic pneumatic circuit.</abstract><cop>England</cop><pub>Elsevier B.V</pub><pmid>30928735</pmid><doi>10.1016/j.bios.2019.03.018</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0956-5663
ispartof Biosensors & bioelectronics, 2019-05, Vol.133, p.169-176
issn 0956-5663
1873-4235
language eng
recordid cdi_proquest_miscellaneous_2221036854
source Elsevier ScienceDirect Journals Complete
subjects Aptamer beacon
biomarkers
biosensors
blood plasma
diagnostic techniques
fluorescence microscopes
Microfluidic pneumatic circuit
oligonucleotides
Plasma separation
point-of-care systems
proteomics
stabilizers
Thrombin
Vacuum pillar
title Integrated microfluidic pneumatic circuit for point-of-care molecular diagnostics
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-06T09%3A56%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Integrated%20microfluidic%20pneumatic%20circuit%20for%20point-of-care%20molecular%20diagnostics&rft.jtitle=Biosensors%20&%20bioelectronics&rft.au=Shin,%20Suyeon&rft.date=2019-05-15&rft.volume=133&rft.spage=169&rft.epage=176&rft.pages=169-176&rft.issn=0956-5663&rft.eissn=1873-4235&rft_id=info:doi/10.1016/j.bios.2019.03.018&rft_dat=%3Cproquest_cross%3E2201709860%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2201709860&rft_id=info:pmid/30928735&rft_els_id=S0956566319302210&rfr_iscdi=true