Comparative study of one-step and two-step quantitative fluorescence photoacoustic tomography

Fluorescence optical tomography (FOT) is a well-known imaging technique, where fluorescent biological markers are injected to tag targeted tissues (tumors, proteins), and the absorption coefficient of fluorophore is reconstructed to provide contrast-enhanced images. Conventional FOT is known to have...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied optics (2004) 2019-04, Vol.58 (12), p.3116-3127
Hauptverfasser: Pandey, Prabodh Kumar, Gottam, Omprakash, Naik, Naren, Pradhan, Asima
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3127
container_issue 12
container_start_page 3116
container_title Applied optics (2004)
container_volume 58
creator Pandey, Prabodh Kumar
Gottam, Omprakash
Naik, Naren
Pradhan, Asima
description Fluorescence optical tomography (FOT) is a well-known imaging technique, where fluorescent biological markers are injected to tag targeted tissues (tumors, proteins), and the absorption coefficient of fluorophore is reconstructed to provide contrast-enhanced images. Conventional FOT is known to have lack of stability to noise and shallow imaging depth due to strong optical scattering in biological tissue. Photoacoustic tomography (PAT) has been previously proposed to combine with FOT to resolve this issue. We propose a fully nonlinear one-step reconstruction in a diffuse-approximation modeled fluorescence photoacoustic tomographic (FPAT) setting, where the absorption coefficient of exogenous fluorophore is recovered directly from the photoacoustic data. Computational validations in two dimensions in single- and dual-grid reconstruction settings using full as well as partial data have been provided in support of the proposed algorithm. One-step schemes are particularly useful with respect to dual representations of field (optical and pressure) variables and optical parameters, especially in limited-data settings, which effectively help in constraining the optimization search space. We have compared the results of one- and two-step FPAT schemes and concluded that the one-step reconstructions are superior as compared with the corresponding two-step reconstructions. To the best of our knowledge, these are the first comparisons of one-step and two-step reconstructions in FPAT.
doi_str_mv 10.1364/AO.58.003116
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2219000160</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2219000160</sourcerecordid><originalsourceid>FETCH-LOGICAL-c319t-5f5537322eb98147aa23daccee9b5a4d1cac2ac8f5b397e3951fecb04508d3523</originalsourceid><addsrcrecordid>eNpd0E1Lw0AQBuBFFFurN88S8OLB1P1MssdS_IJCLwpeJGw2E5uSZOPuRum_d0uqB08zAw_Dy4vQJcFzwhJ-t1jPRTbHmBGSHKEpJULEjCTiGE3DKmNCs7cJOnNuG4zgMj1FE0Yw56nMpuh9adpeWeXrL4icH8pdZKrIdBA7D32kujLy32Y8PgfV-dqPtmoGY8Fp6DRE_cZ4o7QZnK915E1rPqzqN7tzdFKpxsHFYc7Q68P9y_IpXq0fn5eLVawZkT4WlRAsZZRCITPCU6UoK5XWALIQipdEK02VzipRMJkCk4JUoAvMBc5KJiiboZvxb2_N5wDO520dojWN6iCEyiklEmNMEhzo9T-6NYPtQrq94jIRCeNB3Y5KW-OchSrvbd0qu8sJzve154t1LrJ8rD3wq8PToWih_MO_PbMfH6R-eQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2214965634</pqid></control><display><type>article</type><title>Comparative study of one-step and two-step quantitative fluorescence photoacoustic tomography</title><source>Alma/SFX Local Collection</source><source>Optica Publishing Group Journals</source><creator>Pandey, Prabodh Kumar ; Gottam, Omprakash ; Naik, Naren ; Pradhan, Asima</creator><creatorcontrib>Pandey, Prabodh Kumar ; Gottam, Omprakash ; Naik, Naren ; Pradhan, Asima</creatorcontrib><description>Fluorescence optical tomography (FOT) is a well-known imaging technique, where fluorescent biological markers are injected to tag targeted tissues (tumors, proteins), and the absorption coefficient of fluorophore is reconstructed to provide contrast-enhanced images. Conventional FOT is known to have lack of stability to noise and shallow imaging depth due to strong optical scattering in biological tissue. Photoacoustic tomography (PAT) has been previously proposed to combine with FOT to resolve this issue. We propose a fully nonlinear one-step reconstruction in a diffuse-approximation modeled fluorescence photoacoustic tomographic (FPAT) setting, where the absorption coefficient of exogenous fluorophore is recovered directly from the photoacoustic data. Computational validations in two dimensions in single- and dual-grid reconstruction settings using full as well as partial data have been provided in support of the proposed algorithm. One-step schemes are particularly useful with respect to dual representations of field (optical and pressure) variables and optical parameters, especially in limited-data settings, which effectively help in constraining the optimization search space. We have compared the results of one- and two-step FPAT schemes and concluded that the one-step reconstructions are superior as compared with the corresponding two-step reconstructions. To the best of our knowledge, these are the first comparisons of one-step and two-step reconstructions in FPAT.</description><identifier>ISSN: 1559-128X</identifier><identifier>EISSN: 2155-3165</identifier><identifier>EISSN: 1539-4522</identifier><identifier>DOI: 10.1364/AO.58.003116</identifier><identifier>PMID: 31044798</identifier><language>eng</language><publisher>United States: Optical Society of America</publisher><subject>Absorptivity ; Algorithms ; Biomarkers ; Comparative studies ; Fluorescence ; Image contrast ; Image enhancement ; Image reconstruction ; Medical imaging ; Optimization ; Photoacoustic effect ; Proteins ; Tissues ; Tomography</subject><ispartof>Applied optics (2004), 2019-04, Vol.58 (12), p.3116-3127</ispartof><rights>Copyright Optical Society of America Apr 20, 2019</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c319t-5f5537322eb98147aa23daccee9b5a4d1cac2ac8f5b397e3951fecb04508d3523</citedby><cites>FETCH-LOGICAL-c319t-5f5537322eb98147aa23daccee9b5a4d1cac2ac8f5b397e3951fecb04508d3523</cites><orcidid>0000-0003-3949-6747 ; 0000-0002-8962-2580 ; 0000-0003-2726-3399 ; 0000-0002-3351-0141</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,3259,27928,27929</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31044798$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Pandey, Prabodh Kumar</creatorcontrib><creatorcontrib>Gottam, Omprakash</creatorcontrib><creatorcontrib>Naik, Naren</creatorcontrib><creatorcontrib>Pradhan, Asima</creatorcontrib><title>Comparative study of one-step and two-step quantitative fluorescence photoacoustic tomography</title><title>Applied optics (2004)</title><addtitle>Appl Opt</addtitle><description>Fluorescence optical tomography (FOT) is a well-known imaging technique, where fluorescent biological markers are injected to tag targeted tissues (tumors, proteins), and the absorption coefficient of fluorophore is reconstructed to provide contrast-enhanced images. Conventional FOT is known to have lack of stability to noise and shallow imaging depth due to strong optical scattering in biological tissue. Photoacoustic tomography (PAT) has been previously proposed to combine with FOT to resolve this issue. We propose a fully nonlinear one-step reconstruction in a diffuse-approximation modeled fluorescence photoacoustic tomographic (FPAT) setting, where the absorption coefficient of exogenous fluorophore is recovered directly from the photoacoustic data. Computational validations in two dimensions in single- and dual-grid reconstruction settings using full as well as partial data have been provided in support of the proposed algorithm. One-step schemes are particularly useful with respect to dual representations of field (optical and pressure) variables and optical parameters, especially in limited-data settings, which effectively help in constraining the optimization search space. We have compared the results of one- and two-step FPAT schemes and concluded that the one-step reconstructions are superior as compared with the corresponding two-step reconstructions. To the best of our knowledge, these are the first comparisons of one-step and two-step reconstructions in FPAT.</description><subject>Absorptivity</subject><subject>Algorithms</subject><subject>Biomarkers</subject><subject>Comparative studies</subject><subject>Fluorescence</subject><subject>Image contrast</subject><subject>Image enhancement</subject><subject>Image reconstruction</subject><subject>Medical imaging</subject><subject>Optimization</subject><subject>Photoacoustic effect</subject><subject>Proteins</subject><subject>Tissues</subject><subject>Tomography</subject><issn>1559-128X</issn><issn>2155-3165</issn><issn>1539-4522</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNpd0E1Lw0AQBuBFFFurN88S8OLB1P1MssdS_IJCLwpeJGw2E5uSZOPuRum_d0uqB08zAw_Dy4vQJcFzwhJ-t1jPRTbHmBGSHKEpJULEjCTiGE3DKmNCs7cJOnNuG4zgMj1FE0Yw56nMpuh9adpeWeXrL4icH8pdZKrIdBA7D32kujLy32Y8PgfV-dqPtmoGY8Fp6DRE_cZ4o7QZnK915E1rPqzqN7tzdFKpxsHFYc7Q68P9y_IpXq0fn5eLVawZkT4WlRAsZZRCITPCU6UoK5XWALIQipdEK02VzipRMJkCk4JUoAvMBc5KJiiboZvxb2_N5wDO520dojWN6iCEyiklEmNMEhzo9T-6NYPtQrq94jIRCeNB3Y5KW-OchSrvbd0qu8sJzve154t1LrJ8rD3wq8PToWih_MO_PbMfH6R-eQ</recordid><startdate>20190420</startdate><enddate>20190420</enddate><creator>Pandey, Prabodh Kumar</creator><creator>Gottam, Omprakash</creator><creator>Naik, Naren</creator><creator>Pradhan, Asima</creator><general>Optical Society of America</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-3949-6747</orcidid><orcidid>https://orcid.org/0000-0002-8962-2580</orcidid><orcidid>https://orcid.org/0000-0003-2726-3399</orcidid><orcidid>https://orcid.org/0000-0002-3351-0141</orcidid></search><sort><creationdate>20190420</creationdate><title>Comparative study of one-step and two-step quantitative fluorescence photoacoustic tomography</title><author>Pandey, Prabodh Kumar ; Gottam, Omprakash ; Naik, Naren ; Pradhan, Asima</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c319t-5f5537322eb98147aa23daccee9b5a4d1cac2ac8f5b397e3951fecb04508d3523</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Absorptivity</topic><topic>Algorithms</topic><topic>Biomarkers</topic><topic>Comparative studies</topic><topic>Fluorescence</topic><topic>Image contrast</topic><topic>Image enhancement</topic><topic>Image reconstruction</topic><topic>Medical imaging</topic><topic>Optimization</topic><topic>Photoacoustic effect</topic><topic>Proteins</topic><topic>Tissues</topic><topic>Tomography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Pandey, Prabodh Kumar</creatorcontrib><creatorcontrib>Gottam, Omprakash</creatorcontrib><creatorcontrib>Naik, Naren</creatorcontrib><creatorcontrib>Pradhan, Asima</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Applied optics (2004)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Pandey, Prabodh Kumar</au><au>Gottam, Omprakash</au><au>Naik, Naren</au><au>Pradhan, Asima</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparative study of one-step and two-step quantitative fluorescence photoacoustic tomography</atitle><jtitle>Applied optics (2004)</jtitle><addtitle>Appl Opt</addtitle><date>2019-04-20</date><risdate>2019</risdate><volume>58</volume><issue>12</issue><spage>3116</spage><epage>3127</epage><pages>3116-3127</pages><issn>1559-128X</issn><eissn>2155-3165</eissn><eissn>1539-4522</eissn><abstract>Fluorescence optical tomography (FOT) is a well-known imaging technique, where fluorescent biological markers are injected to tag targeted tissues (tumors, proteins), and the absorption coefficient of fluorophore is reconstructed to provide contrast-enhanced images. Conventional FOT is known to have lack of stability to noise and shallow imaging depth due to strong optical scattering in biological tissue. Photoacoustic tomography (PAT) has been previously proposed to combine with FOT to resolve this issue. We propose a fully nonlinear one-step reconstruction in a diffuse-approximation modeled fluorescence photoacoustic tomographic (FPAT) setting, where the absorption coefficient of exogenous fluorophore is recovered directly from the photoacoustic data. Computational validations in two dimensions in single- and dual-grid reconstruction settings using full as well as partial data have been provided in support of the proposed algorithm. One-step schemes are particularly useful with respect to dual representations of field (optical and pressure) variables and optical parameters, especially in limited-data settings, which effectively help in constraining the optimization search space. We have compared the results of one- and two-step FPAT schemes and concluded that the one-step reconstructions are superior as compared with the corresponding two-step reconstructions. To the best of our knowledge, these are the first comparisons of one-step and two-step reconstructions in FPAT.</abstract><cop>United States</cop><pub>Optical Society of America</pub><pmid>31044798</pmid><doi>10.1364/AO.58.003116</doi><tpages>12</tpages><orcidid>https://orcid.org/0000-0003-3949-6747</orcidid><orcidid>https://orcid.org/0000-0002-8962-2580</orcidid><orcidid>https://orcid.org/0000-0003-2726-3399</orcidid><orcidid>https://orcid.org/0000-0002-3351-0141</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1559-128X
ispartof Applied optics (2004), 2019-04, Vol.58 (12), p.3116-3127
issn 1559-128X
2155-3165
1539-4522
language eng
recordid cdi_proquest_miscellaneous_2219000160
source Alma/SFX Local Collection; Optica Publishing Group Journals
subjects Absorptivity
Algorithms
Biomarkers
Comparative studies
Fluorescence
Image contrast
Image enhancement
Image reconstruction
Medical imaging
Optimization
Photoacoustic effect
Proteins
Tissues
Tomography
title Comparative study of one-step and two-step quantitative fluorescence photoacoustic tomography
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-17T07%3A06%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparative%20study%20of%20one-step%20and%20two-step%20quantitative%20fluorescence%20photoacoustic%20tomography&rft.jtitle=Applied%20optics%20(2004)&rft.au=Pandey,%20Prabodh%20Kumar&rft.date=2019-04-20&rft.volume=58&rft.issue=12&rft.spage=3116&rft.epage=3127&rft.pages=3116-3127&rft.issn=1559-128X&rft.eissn=2155-3165&rft_id=info:doi/10.1364/AO.58.003116&rft_dat=%3Cproquest_cross%3E2219000160%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2214965634&rft_id=info:pmid/31044798&rfr_iscdi=true