Effect of scan pattern on complete-arch scans with 4 digital scanners

Complete-arch digital scans are becoming popular as digital dentistry is adopted for expanded clinical situations such as complete-arch prostheses, removable prostheses, extensive implant-supported treatment, and orthodontic aligners. Whether the scan pattern technique affects the trueness and preci...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of prosthetic dentistry 2020-01, Vol.123 (1), p.85-95
Hauptverfasser: Latham, Jason, Ludlow, Mark, Mennito, Anthony, Kelly, Abigail, Evans, Zachary, Renne, Walter
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 95
container_issue 1
container_start_page 85
container_title The Journal of prosthetic dentistry
container_volume 123
creator Latham, Jason
Ludlow, Mark
Mennito, Anthony
Kelly, Abigail
Evans, Zachary
Renne, Walter
description Complete-arch digital scans are becoming popular as digital dentistry is adopted for expanded clinical situations such as complete-arch prostheses, removable prostheses, extensive implant-supported treatment, and orthodontic aligners. Whether the scan pattern technique affects the trueness and precision of complete-arch scans and whether differences in accuracy exist among different scanners remain unclear. Furthermore, each manufacturer recommends a different scan pattern, but evidence of the superiority of the manufacturer’s recommended pattern is lacking. The purpose of this in vitro study was to determine whether the scan pattern affects the trueness, precision, and speed of complete-arch digital scans performed by using 4 different digital scanning systems. A custom model used as the reference standard was fabricated with teeth having the same refractive index as dentin and enamel to simulate the natural dentition. The scan of the custom typodont was obtained by using an ATOS III Triple Scan 3D optical scanner. This study evaluated the CEREC Omnicam, Planmeca Emerald, Align iTero Element, and 3Shape TRIOS 3. Experimental scans were obtained from each of the 4 different digital scanning systems by using 4 unique scan patterns by experienced clinicians. Four experimental scans were acquired from each of the scanners by using 4 distinct scan patterns for a total of 16 scans for each scanner. Scan patterns 1 to 4 were based on the operator manuals for each different scanner. The scan time was recorded for each scan. All experimental scans were converted to standard tessellation language (STL) format, and a comprehensive metrology program, Geomagic Control X, was used to compare the reference standard scan with the experimental scans. For trueness, the scanner (P
doi_str_mv 10.1016/j.prosdent.2019.02.008
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2210002554</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0022391319301520</els_id><sourcerecordid>2210002554</sourcerecordid><originalsourceid>FETCH-LOGICAL-c416t-34068bcdccb466e64c7f042e54cae39ba7250a62c7049a6a44a4de782bf7d1b23</originalsourceid><addsrcrecordid>eNqFkMtOwzAQRS0EoqXwC1WWbBLGjuMkO1BVHlIlNrC2HGdCXeWF7YL4e9wXW1YjzZyZ0T2EzCkkFKi42ySjHVyNvU8Y0DIBlgAUZ2RKocxjUXB6TqYAjMVpSdMJuXJuA4HIcnpJJimUBRNUTMly2TSofTQ0kdOqj0blPdo-GvpID93YosdYWb3eT130bfw64lFtPoxX7b7Zo3XX5KJRrcObY52R98fl2-I5Xr0-vSweVrHmVPg45SCKStdaV1wIFFznDXCGGdcK07JSOctACaZz4KUSinPFa8wLVjV5TSuWzsjt4W4I_7lF52VnnMa2VT0OWycZoyEkyzIeUHFAdfDkLDZytKZT9kdSkDuFciNPCuVOoQQmg6CwOD_-2FYd1n9rJ2cBuD8AGJJ-GbTSaYO9xtrYoFLWg_nvxy_MDYWM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2210002554</pqid></control><display><type>article</type><title>Effect of scan pattern on complete-arch scans with 4 digital scanners</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Latham, Jason ; Ludlow, Mark ; Mennito, Anthony ; Kelly, Abigail ; Evans, Zachary ; Renne, Walter</creator><creatorcontrib>Latham, Jason ; Ludlow, Mark ; Mennito, Anthony ; Kelly, Abigail ; Evans, Zachary ; Renne, Walter</creatorcontrib><description>Complete-arch digital scans are becoming popular as digital dentistry is adopted for expanded clinical situations such as complete-arch prostheses, removable prostheses, extensive implant-supported treatment, and orthodontic aligners. Whether the scan pattern technique affects the trueness and precision of complete-arch scans and whether differences in accuracy exist among different scanners remain unclear. Furthermore, each manufacturer recommends a different scan pattern, but evidence of the superiority of the manufacturer’s recommended pattern is lacking. The purpose of this in vitro study was to determine whether the scan pattern affects the trueness, precision, and speed of complete-arch digital scans performed by using 4 different digital scanning systems. A custom model used as the reference standard was fabricated with teeth having the same refractive index as dentin and enamel to simulate the natural dentition. The scan of the custom typodont was obtained by using an ATOS III Triple Scan 3D optical scanner. This study evaluated the CEREC Omnicam, Planmeca Emerald, Align iTero Element, and 3Shape TRIOS 3. Experimental scans were obtained from each of the 4 different digital scanning systems by using 4 unique scan patterns by experienced clinicians. Four experimental scans were acquired from each of the scanners by using 4 distinct scan patterns for a total of 16 scans for each scanner. Scan patterns 1 to 4 were based on the operator manuals for each different scanner. The scan time was recorded for each scan. All experimental scans were converted to standard tessellation language (STL) format, and a comprehensive metrology program, Geomagic Control X, was used to compare the reference standard scan with the experimental scans. For trueness, the scanner (P&lt;.001), scan pattern (P=.001), and their interaction (P&lt;.001) were found to be significant. Overall, scan pattern 2 showed the highest average trueness and precision. Likewise, for overall scan pattern precision, the scanner, scan pattern, and their interaction were found to be significant (P&lt;.001). Scan pattern affected trueness and precision for some scanners, but not for others. Differences exist in the complete-arch scan speed, trueness, and precision of individual scanners. Scan pattern can play an important role in the success of digital scanning.</description><identifier>ISSN: 0022-3913</identifier><identifier>EISSN: 1097-6841</identifier><identifier>DOI: 10.1016/j.prosdent.2019.02.008</identifier><identifier>PMID: 30982616</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Computer-Aided Design ; Dental Arch ; Dental Impression Technique ; Dental Models ; Dentistry ; Humans ; Imaging, Three-Dimensional ; Mouth, Edentulous</subject><ispartof>The Journal of prosthetic dentistry, 2020-01, Vol.123 (1), p.85-95</ispartof><rights>2019 Editorial Council for the Journal of Prosthetic Dentistry</rights><rights>Copyright © 2019 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c416t-34068bcdccb466e64c7f042e54cae39ba7250a62c7049a6a44a4de782bf7d1b23</citedby><cites>FETCH-LOGICAL-c416t-34068bcdccb466e64c7f042e54cae39ba7250a62c7049a6a44a4de782bf7d1b23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0022391319301520$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30982616$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Latham, Jason</creatorcontrib><creatorcontrib>Ludlow, Mark</creatorcontrib><creatorcontrib>Mennito, Anthony</creatorcontrib><creatorcontrib>Kelly, Abigail</creatorcontrib><creatorcontrib>Evans, Zachary</creatorcontrib><creatorcontrib>Renne, Walter</creatorcontrib><title>Effect of scan pattern on complete-arch scans with 4 digital scanners</title><title>The Journal of prosthetic dentistry</title><addtitle>J Prosthet Dent</addtitle><description>Complete-arch digital scans are becoming popular as digital dentistry is adopted for expanded clinical situations such as complete-arch prostheses, removable prostheses, extensive implant-supported treatment, and orthodontic aligners. Whether the scan pattern technique affects the trueness and precision of complete-arch scans and whether differences in accuracy exist among different scanners remain unclear. Furthermore, each manufacturer recommends a different scan pattern, but evidence of the superiority of the manufacturer’s recommended pattern is lacking. The purpose of this in vitro study was to determine whether the scan pattern affects the trueness, precision, and speed of complete-arch digital scans performed by using 4 different digital scanning systems. A custom model used as the reference standard was fabricated with teeth having the same refractive index as dentin and enamel to simulate the natural dentition. The scan of the custom typodont was obtained by using an ATOS III Triple Scan 3D optical scanner. This study evaluated the CEREC Omnicam, Planmeca Emerald, Align iTero Element, and 3Shape TRIOS 3. Experimental scans were obtained from each of the 4 different digital scanning systems by using 4 unique scan patterns by experienced clinicians. Four experimental scans were acquired from each of the scanners by using 4 distinct scan patterns for a total of 16 scans for each scanner. Scan patterns 1 to 4 were based on the operator manuals for each different scanner. The scan time was recorded for each scan. All experimental scans were converted to standard tessellation language (STL) format, and a comprehensive metrology program, Geomagic Control X, was used to compare the reference standard scan with the experimental scans. For trueness, the scanner (P&lt;.001), scan pattern (P=.001), and their interaction (P&lt;.001) were found to be significant. Overall, scan pattern 2 showed the highest average trueness and precision. Likewise, for overall scan pattern precision, the scanner, scan pattern, and their interaction were found to be significant (P&lt;.001). Scan pattern affected trueness and precision for some scanners, but not for others. Differences exist in the complete-arch scan speed, trueness, and precision of individual scanners. Scan pattern can play an important role in the success of digital scanning.</description><subject>Computer-Aided Design</subject><subject>Dental Arch</subject><subject>Dental Impression Technique</subject><subject>Dental Models</subject><subject>Dentistry</subject><subject>Humans</subject><subject>Imaging, Three-Dimensional</subject><subject>Mouth, Edentulous</subject><issn>0022-3913</issn><issn>1097-6841</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkMtOwzAQRS0EoqXwC1WWbBLGjuMkO1BVHlIlNrC2HGdCXeWF7YL4e9wXW1YjzZyZ0T2EzCkkFKi42ySjHVyNvU8Y0DIBlgAUZ2RKocxjUXB6TqYAjMVpSdMJuXJuA4HIcnpJJimUBRNUTMly2TSofTQ0kdOqj0blPdo-GvpID93YosdYWb3eT130bfw64lFtPoxX7b7Zo3XX5KJRrcObY52R98fl2-I5Xr0-vSweVrHmVPg45SCKStdaV1wIFFznDXCGGdcK07JSOctACaZz4KUSinPFa8wLVjV5TSuWzsjt4W4I_7lF52VnnMa2VT0OWycZoyEkyzIeUHFAdfDkLDZytKZT9kdSkDuFciNPCuVOoQQmg6CwOD_-2FYd1n9rJ2cBuD8AGJJ-GbTSaYO9xtrYoFLWg_nvxy_MDYWM</recordid><startdate>202001</startdate><enddate>202001</enddate><creator>Latham, Jason</creator><creator>Ludlow, Mark</creator><creator>Mennito, Anthony</creator><creator>Kelly, Abigail</creator><creator>Evans, Zachary</creator><creator>Renne, Walter</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202001</creationdate><title>Effect of scan pattern on complete-arch scans with 4 digital scanners</title><author>Latham, Jason ; Ludlow, Mark ; Mennito, Anthony ; Kelly, Abigail ; Evans, Zachary ; Renne, Walter</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c416t-34068bcdccb466e64c7f042e54cae39ba7250a62c7049a6a44a4de782bf7d1b23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Computer-Aided Design</topic><topic>Dental Arch</topic><topic>Dental Impression Technique</topic><topic>Dental Models</topic><topic>Dentistry</topic><topic>Humans</topic><topic>Imaging, Three-Dimensional</topic><topic>Mouth, Edentulous</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Latham, Jason</creatorcontrib><creatorcontrib>Ludlow, Mark</creatorcontrib><creatorcontrib>Mennito, Anthony</creatorcontrib><creatorcontrib>Kelly, Abigail</creatorcontrib><creatorcontrib>Evans, Zachary</creatorcontrib><creatorcontrib>Renne, Walter</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of prosthetic dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Latham, Jason</au><au>Ludlow, Mark</au><au>Mennito, Anthony</au><au>Kelly, Abigail</au><au>Evans, Zachary</au><au>Renne, Walter</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of scan pattern on complete-arch scans with 4 digital scanners</atitle><jtitle>The Journal of prosthetic dentistry</jtitle><addtitle>J Prosthet Dent</addtitle><date>2020-01</date><risdate>2020</risdate><volume>123</volume><issue>1</issue><spage>85</spage><epage>95</epage><pages>85-95</pages><issn>0022-3913</issn><eissn>1097-6841</eissn><abstract>Complete-arch digital scans are becoming popular as digital dentistry is adopted for expanded clinical situations such as complete-arch prostheses, removable prostheses, extensive implant-supported treatment, and orthodontic aligners. Whether the scan pattern technique affects the trueness and precision of complete-arch scans and whether differences in accuracy exist among different scanners remain unclear. Furthermore, each manufacturer recommends a different scan pattern, but evidence of the superiority of the manufacturer’s recommended pattern is lacking. The purpose of this in vitro study was to determine whether the scan pattern affects the trueness, precision, and speed of complete-arch digital scans performed by using 4 different digital scanning systems. A custom model used as the reference standard was fabricated with teeth having the same refractive index as dentin and enamel to simulate the natural dentition. The scan of the custom typodont was obtained by using an ATOS III Triple Scan 3D optical scanner. This study evaluated the CEREC Omnicam, Planmeca Emerald, Align iTero Element, and 3Shape TRIOS 3. Experimental scans were obtained from each of the 4 different digital scanning systems by using 4 unique scan patterns by experienced clinicians. Four experimental scans were acquired from each of the scanners by using 4 distinct scan patterns for a total of 16 scans for each scanner. Scan patterns 1 to 4 were based on the operator manuals for each different scanner. The scan time was recorded for each scan. All experimental scans were converted to standard tessellation language (STL) format, and a comprehensive metrology program, Geomagic Control X, was used to compare the reference standard scan with the experimental scans. For trueness, the scanner (P&lt;.001), scan pattern (P=.001), and their interaction (P&lt;.001) were found to be significant. Overall, scan pattern 2 showed the highest average trueness and precision. Likewise, for overall scan pattern precision, the scanner, scan pattern, and their interaction were found to be significant (P&lt;.001). Scan pattern affected trueness and precision for some scanners, but not for others. Differences exist in the complete-arch scan speed, trueness, and precision of individual scanners. Scan pattern can play an important role in the success of digital scanning.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>30982616</pmid><doi>10.1016/j.prosdent.2019.02.008</doi><tpages>11</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0022-3913
ispartof The Journal of prosthetic dentistry, 2020-01, Vol.123 (1), p.85-95
issn 0022-3913
1097-6841
language eng
recordid cdi_proquest_miscellaneous_2210002554
source MEDLINE; Elsevier ScienceDirect Journals
subjects Computer-Aided Design
Dental Arch
Dental Impression Technique
Dental Models
Dentistry
Humans
Imaging, Three-Dimensional
Mouth, Edentulous
title Effect of scan pattern on complete-arch scans with 4 digital scanners
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T11%3A43%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20scan%20pattern%20on%20complete-arch%20scans%20with%204%20digital%20scanners&rft.jtitle=The%20Journal%20of%20prosthetic%20dentistry&rft.au=Latham,%20Jason&rft.date=2020-01&rft.volume=123&rft.issue=1&rft.spage=85&rft.epage=95&rft.pages=85-95&rft.issn=0022-3913&rft.eissn=1097-6841&rft_id=info:doi/10.1016/j.prosdent.2019.02.008&rft_dat=%3Cproquest_cross%3E2210002554%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2210002554&rft_id=info:pmid/30982616&rft_els_id=S0022391319301520&rfr_iscdi=true