Study of X-ray scattered in a phantom as function of its maximum energy during bimodal PET/CT imaging

In a simultaneous Bimodal System with Positron Emission Tomography and Computed Tomography, the X-rays from a collimated X-ray tube are scattered over an anatomical region on the patient being scanning and cause a contamination effect on the signal received by the detectors distributed in the shape...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied radiation and isotopes 2019-06, Vol.148, p.1-6
Hauptverfasser: Olaya Dávila, H., Martinez-Ovalle, S.A., Vega-Carrillo, H.R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 6
container_issue
container_start_page 1
container_title Applied radiation and isotopes
container_volume 148
creator Olaya Dávila, H.
Martinez-Ovalle, S.A.
Vega-Carrillo, H.R.
description In a simultaneous Bimodal System with Positron Emission Tomography and Computed Tomography, the X-rays from a collimated X-ray tube are scattered over an anatomical region on the patient being scanning and cause a contamination effect on the signal received by the detectors distributed in the shape of a ring of the PET system. To study this phenomenon, each of the components of a bimodal system was modeled and simulated by the Monte Carlo method in Geant4 an X-ray beam produced in a RTW tube MCBM 65B with typical fluences used in medical diagnosis of small animals hitting a cylindrical phantom with a diameter greater than Field of View (FOV) in the tomographic center. The number of ionization events that occur in each of the phoswich detectors of the PET were obtained, the spatial distribution of the scattered X-rays was studied according to three maximum energies of the spectrum and calculation was made to find a filter that was located at the input of the phoswich detector that attenuates the X-rays by 98% and that would allow transmitting the gamma rays of annihilation also by 98%. For this, simulations were carried out using various filter materials, finding that copper is an excellent candidate and were found an optimum thicknesses between 0.5 mm and 1.3 mm, according to the average energy of the X-rays used in the different exploration techniques. •In a bimodal PET/CT system X-ray photons being scattered in a phantom has been estimated using Monte Carlo method.•Calculations were carried out with the Geant4 code where a detail model of PET/CT system was built.•The use of proper filter thickness at the phoswich detectors entrance reduce the noise signal.
doi_str_mv 10.1016/j.apradiso.2019.03.002
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2194583776</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0969804318311229</els_id><sourcerecordid>2194583776</sourcerecordid><originalsourceid>FETCH-LOGICAL-c368t-35c557c89765f95ab4b01390b7508744ded70af26478249bb159d7910d903cf73</originalsourceid><addsrcrecordid>eNqFkE1r3DAQhkVpaDZp_0LQsRc7I8uypFvLkqaFQAvZQm9ClsZbLWtrK8kl--_jZZNeexoYnnc-HkJuGNQMWHe7q-0hWR9yrBtgugZeAzRvyIop2VRaAbwlK9CdrhS0_JJc5bwDgFbp5h255KCUFo1aEXwssz_SONBfVbJHmp0tBRN6GiZq6eG3nUocqc10mCdXQpxObCiZjvYpjPNIccK0PVI_pzBtaR_G6O2e_rjb3K43NIx2u7Tfk4vB7jN-eKnX5OeXu836a_Xw_f7b-vND5XinSsWFE0I6pWUnBi1s3_bAuIZeClCybT16CXZoulaqptV9z4T2UjPwGrgbJL8mH89zDyn-mTEXM4bscL-3E8Y5m4bpViguZbeg3Rl1KeaccDCHtFybjoaBOSk2O_Oq2JwUG-BmUbwEb152zP2I_l_s1ekCfDoDuHz6N2Ay2QWcHPqQ0BXjY_jfjmf7zo9x</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2194583776</pqid></control><display><type>article</type><title>Study of X-ray scattered in a phantom as function of its maximum energy during bimodal PET/CT imaging</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Olaya Dávila, H. ; Martinez-Ovalle, S.A. ; Vega-Carrillo, H.R.</creator><creatorcontrib>Olaya Dávila, H. ; Martinez-Ovalle, S.A. ; Vega-Carrillo, H.R.</creatorcontrib><description>In a simultaneous Bimodal System with Positron Emission Tomography and Computed Tomography, the X-rays from a collimated X-ray tube are scattered over an anatomical region on the patient being scanning and cause a contamination effect on the signal received by the detectors distributed in the shape of a ring of the PET system. To study this phenomenon, each of the components of a bimodal system was modeled and simulated by the Monte Carlo method in Geant4 an X-ray beam produced in a RTW tube MCBM 65B with typical fluences used in medical diagnosis of small animals hitting a cylindrical phantom with a diameter greater than Field of View (FOV) in the tomographic center. The number of ionization events that occur in each of the phoswich detectors of the PET were obtained, the spatial distribution of the scattered X-rays was studied according to three maximum energies of the spectrum and calculation was made to find a filter that was located at the input of the phoswich detector that attenuates the X-rays by 98% and that would allow transmitting the gamma rays of annihilation also by 98%. For this, simulations were carried out using various filter materials, finding that copper is an excellent candidate and were found an optimum thicknesses between 0.5 mm and 1.3 mm, according to the average energy of the X-rays used in the different exploration techniques. •In a bimodal PET/CT system X-ray photons being scattered in a phantom has been estimated using Monte Carlo method.•Calculations were carried out with the Geant4 code where a detail model of PET/CT system was built.•The use of proper filter thickness at the phoswich detectors entrance reduce the noise signal.</description><identifier>ISSN: 0969-8043</identifier><identifier>EISSN: 1872-9800</identifier><identifier>DOI: 10.1016/j.apradiso.2019.03.002</identifier><identifier>PMID: 30889528</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Animals ; Bimodal system ; Equipment Design ; Humans ; Monte Carlo Method ; Monte Carlo simulation ; Patient Simulation ; PET ; Phantoms, Imaging ; Phoswich ; Positron Emission Tomography Computed Tomography - methods ; Scattering, Radiation ; X-Rays</subject><ispartof>Applied radiation and isotopes, 2019-06, Vol.148, p.1-6</ispartof><rights>2019 Elsevier Ltd</rights><rights>Copyright © 2019 Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c368t-35c557c89765f95ab4b01390b7508744ded70af26478249bb159d7910d903cf73</citedby><cites>FETCH-LOGICAL-c368t-35c557c89765f95ab4b01390b7508744ded70af26478249bb159d7910d903cf73</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.apradiso.2019.03.002$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30889528$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Olaya Dávila, H.</creatorcontrib><creatorcontrib>Martinez-Ovalle, S.A.</creatorcontrib><creatorcontrib>Vega-Carrillo, H.R.</creatorcontrib><title>Study of X-ray scattered in a phantom as function of its maximum energy during bimodal PET/CT imaging</title><title>Applied radiation and isotopes</title><addtitle>Appl Radiat Isot</addtitle><description>In a simultaneous Bimodal System with Positron Emission Tomography and Computed Tomography, the X-rays from a collimated X-ray tube are scattered over an anatomical region on the patient being scanning and cause a contamination effect on the signal received by the detectors distributed in the shape of a ring of the PET system. To study this phenomenon, each of the components of a bimodal system was modeled and simulated by the Monte Carlo method in Geant4 an X-ray beam produced in a RTW tube MCBM 65B with typical fluences used in medical diagnosis of small animals hitting a cylindrical phantom with a diameter greater than Field of View (FOV) in the tomographic center. The number of ionization events that occur in each of the phoswich detectors of the PET were obtained, the spatial distribution of the scattered X-rays was studied according to three maximum energies of the spectrum and calculation was made to find a filter that was located at the input of the phoswich detector that attenuates the X-rays by 98% and that would allow transmitting the gamma rays of annihilation also by 98%. For this, simulations were carried out using various filter materials, finding that copper is an excellent candidate and were found an optimum thicknesses between 0.5 mm and 1.3 mm, according to the average energy of the X-rays used in the different exploration techniques. •In a bimodal PET/CT system X-ray photons being scattered in a phantom has been estimated using Monte Carlo method.•Calculations were carried out with the Geant4 code where a detail model of PET/CT system was built.•The use of proper filter thickness at the phoswich detectors entrance reduce the noise signal.</description><subject>Animals</subject><subject>Bimodal system</subject><subject>Equipment Design</subject><subject>Humans</subject><subject>Monte Carlo Method</subject><subject>Monte Carlo simulation</subject><subject>Patient Simulation</subject><subject>PET</subject><subject>Phantoms, Imaging</subject><subject>Phoswich</subject><subject>Positron Emission Tomography Computed Tomography - methods</subject><subject>Scattering, Radiation</subject><subject>X-Rays</subject><issn>0969-8043</issn><issn>1872-9800</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkE1r3DAQhkVpaDZp_0LQsRc7I8uypFvLkqaFQAvZQm9ClsZbLWtrK8kl--_jZZNeexoYnnc-HkJuGNQMWHe7q-0hWR9yrBtgugZeAzRvyIop2VRaAbwlK9CdrhS0_JJc5bwDgFbp5h255KCUFo1aEXwssz_SONBfVbJHmp0tBRN6GiZq6eG3nUocqc10mCdXQpxObCiZjvYpjPNIccK0PVI_pzBtaR_G6O2e_rjb3K43NIx2u7Tfk4vB7jN-eKnX5OeXu836a_Xw_f7b-vND5XinSsWFE0I6pWUnBi1s3_bAuIZeClCybT16CXZoulaqptV9z4T2UjPwGrgbJL8mH89zDyn-mTEXM4bscL-3E8Y5m4bpViguZbeg3Rl1KeaccDCHtFybjoaBOSk2O_Oq2JwUG-BmUbwEb152zP2I_l_s1ekCfDoDuHz6N2Ay2QWcHPqQ0BXjY_jfjmf7zo9x</recordid><startdate>201906</startdate><enddate>201906</enddate><creator>Olaya Dávila, H.</creator><creator>Martinez-Ovalle, S.A.</creator><creator>Vega-Carrillo, H.R.</creator><general>Elsevier Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201906</creationdate><title>Study of X-ray scattered in a phantom as function of its maximum energy during bimodal PET/CT imaging</title><author>Olaya Dávila, H. ; Martinez-Ovalle, S.A. ; Vega-Carrillo, H.R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c368t-35c557c89765f95ab4b01390b7508744ded70af26478249bb159d7910d903cf73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Animals</topic><topic>Bimodal system</topic><topic>Equipment Design</topic><topic>Humans</topic><topic>Monte Carlo Method</topic><topic>Monte Carlo simulation</topic><topic>Patient Simulation</topic><topic>PET</topic><topic>Phantoms, Imaging</topic><topic>Phoswich</topic><topic>Positron Emission Tomography Computed Tomography - methods</topic><topic>Scattering, Radiation</topic><topic>X-Rays</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Olaya Dávila, H.</creatorcontrib><creatorcontrib>Martinez-Ovalle, S.A.</creatorcontrib><creatorcontrib>Vega-Carrillo, H.R.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Applied radiation and isotopes</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Olaya Dávila, H.</au><au>Martinez-Ovalle, S.A.</au><au>Vega-Carrillo, H.R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Study of X-ray scattered in a phantom as function of its maximum energy during bimodal PET/CT imaging</atitle><jtitle>Applied radiation and isotopes</jtitle><addtitle>Appl Radiat Isot</addtitle><date>2019-06</date><risdate>2019</risdate><volume>148</volume><spage>1</spage><epage>6</epage><pages>1-6</pages><issn>0969-8043</issn><eissn>1872-9800</eissn><abstract>In a simultaneous Bimodal System with Positron Emission Tomography and Computed Tomography, the X-rays from a collimated X-ray tube are scattered over an anatomical region on the patient being scanning and cause a contamination effect on the signal received by the detectors distributed in the shape of a ring of the PET system. To study this phenomenon, each of the components of a bimodal system was modeled and simulated by the Monte Carlo method in Geant4 an X-ray beam produced in a RTW tube MCBM 65B with typical fluences used in medical diagnosis of small animals hitting a cylindrical phantom with a diameter greater than Field of View (FOV) in the tomographic center. The number of ionization events that occur in each of the phoswich detectors of the PET were obtained, the spatial distribution of the scattered X-rays was studied according to three maximum energies of the spectrum and calculation was made to find a filter that was located at the input of the phoswich detector that attenuates the X-rays by 98% and that would allow transmitting the gamma rays of annihilation also by 98%. For this, simulations were carried out using various filter materials, finding that copper is an excellent candidate and were found an optimum thicknesses between 0.5 mm and 1.3 mm, according to the average energy of the X-rays used in the different exploration techniques. •In a bimodal PET/CT system X-ray photons being scattered in a phantom has been estimated using Monte Carlo method.•Calculations were carried out with the Geant4 code where a detail model of PET/CT system was built.•The use of proper filter thickness at the phoswich detectors entrance reduce the noise signal.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>30889528</pmid><doi>10.1016/j.apradiso.2019.03.002</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0969-8043
ispartof Applied radiation and isotopes, 2019-06, Vol.148, p.1-6
issn 0969-8043
1872-9800
language eng
recordid cdi_proquest_miscellaneous_2194583776
source MEDLINE; Access via ScienceDirect (Elsevier)
subjects Animals
Bimodal system
Equipment Design
Humans
Monte Carlo Method
Monte Carlo simulation
Patient Simulation
PET
Phantoms, Imaging
Phoswich
Positron Emission Tomography Computed Tomography - methods
Scattering, Radiation
X-Rays
title Study of X-ray scattered in a phantom as function of its maximum energy during bimodal PET/CT imaging
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T23%3A44%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Study%20of%20X-ray%20scattered%20in%20a%20phantom%20as%20function%20of%20its%20maximum%20energy%20during%20bimodal%20PET/CT%20imaging&rft.jtitle=Applied%20radiation%20and%20isotopes&rft.au=Olaya%20D%C3%A1vila,%20H.&rft.date=2019-06&rft.volume=148&rft.spage=1&rft.epage=6&rft.pages=1-6&rft.issn=0969-8043&rft.eissn=1872-9800&rft_id=info:doi/10.1016/j.apradiso.2019.03.002&rft_dat=%3Cproquest_cross%3E2194583776%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2194583776&rft_id=info:pmid/30889528&rft_els_id=S0969804318311229&rfr_iscdi=true