Recommendations of the Spanish Antibiogram Committee (COESANT) for selecting antimicrobial agents and concentrations for in vitro susceptibility studies using automated systems

Abstract Automated antimicrobial susceptibility testing devices are widely implemented in clinical microbiology laboratories in Spain, mainly using EUCAST (European Committee on Antimicrobial Susceptibility Testing) breakpoints. In 2007, a group of experts published recommendations for including ant...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Enfermedades infecciosas y microbiologia clinica 2020-04, Vol.38 (4), p.182-187
Hauptverfasser: Cantón, Rafael, Oliver, Antonio, Alós, Juan Ignacio, de Benito, Natividad, Bou, Germán, Campos, José, Calvo, Jorge, Canut, Andrés, Castillo, Javier, Cercenado, Emilia, Domínguez, Maria Ángeles, Fernández-Cuenca, Felipe, Guinea, Jesús, Larrosa, Nieves, Liñares, Josefina, López-Cerero, Lorena, López-Navas, Antonio, Marco, Francesc, Mirelis, Beatriz, Moreno-Romo, Miguel Ángel, Morosini, María Isabel, Navarro, Ferran, Oteo, Jesús, Pascual, Álvaro, Pérez-Trallero, Emilio, Pérez-Vázquez, María, Soriano, Alex, Torres, Carmen, Vila, Jordi, Martínez-Martínez, Luis
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 187
container_issue 4
container_start_page 182
container_title Enfermedades infecciosas y microbiologia clinica
container_volume 38
creator Cantón, Rafael
Oliver, Antonio
Alós, Juan Ignacio
de Benito, Natividad
Bou, Germán
Campos, José
Calvo, Jorge
Canut, Andrés
Castillo, Javier
Cercenado, Emilia
Domínguez, Maria Ángeles
Fernández-Cuenca, Felipe
Guinea, Jesús
Larrosa, Nieves
Liñares, Josefina
López-Cerero, Lorena
López-Navas, Antonio
Marco, Francesc
Mirelis, Beatriz
Moreno-Romo, Miguel Ángel
Morosini, María Isabel
Navarro, Ferran
Oteo, Jesús
Pascual, Álvaro
Pérez-Trallero, Emilio
Pérez-Vázquez, María
Soriano, Alex
Torres, Carmen
Vila, Jordi
Martínez-Martínez, Luis
description Abstract Automated antimicrobial susceptibility testing devices are widely implemented in clinical microbiology laboratories in Spain, mainly using EUCAST (European Committee on Antimicrobial Susceptibility Testing) breakpoints. In 2007, a group of experts published recommendations for including antimicrobial agents and selecting concentrations in these systems. Under the patronage of the Spanish Antibiogram Committee ( Comité Español del Antibiograma , COESANT) and the Study Group on Mechanisms of Action and Resistance to Antimicrobial Agents (GEMARA) from the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC), and aligned with the Spanish National Plan against Antimicrobial Resistance (PRAN), a group of experts have updated this document. The main modifications from the previous version comprise the inclusion of new antimicrobial agents, adaptation of the ranges of concentrations to cover the EUCAST breakpoints and epidemiological cut-off values (ECOFFs), and the inference of new resistance mechanisms. This proposal should be considered by different manufacturers and users when designing new panels or cards. In addition, recommendations for selective reporting are also included. With this approach, the implementation of EUCAST breakpoints will be easier, increasing the quality of antimicrobial susceptibility testing data and their microbiological interpretation. It will also benefit epidemiological surveillance studies as well as the clinical use of antimicrobials aligned with antimicrobial stewardship programs.
doi_str_mv 10.1016/j.eimc.2019.01.017
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2193602320</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>1_s2_0_S0213005X19301351</els_id><sourcerecordid>2193602320</sourcerecordid><originalsourceid>FETCH-LOGICAL-c455t-e55bc3395095c7e202ff0cefd2f545b61dea3d663abcb6ea9d1df4aa8a19fab03</originalsourceid><addsrcrecordid>eNp9UsuKFDEULURx2tEfcCFZjotq8-jUA0RomvEBgwP2CO5CKrnVk7YqaXNTA_1XfqIpu3XhQrgQEs45N_ecWxQvGV0yyqo3-yW40Sw5Ze2Sslz1o2LBZN2UrJH8cbGgnImSUvntoniGuKeUSyHE0-JC0KZuBBOL4ucXMGEcwVudXPBIQk_SPZDtQXuH92Ttk-tc2EU9kk0GupQAyNXm9nq7_nz3mvQhEoQBTHJ-R3RGj87E0Dk9EL0DnzA_WmKCN_kSz01mlvPkwaUYCE5o4DC3GVw6EkyTdYBkwt-KUwqjTmAJHjHBiM-LJ70eEF6cz8vi6_vru83H8ub2w6fN-qY0KylTCVJ2RohW0laaGjjlfU8N9Jb3ciW7ilnQwlaV0J3pKtCtZbZfad1o1va6o-KyuDrpHmL4MQEmNbr8z2HQHsKEirNWVJQLPkP5CZoHR4zQq0N0o45Hxaiak1J7NSel5qQUZbnqTHp11p-6Eexfyp9oMuDtCQB5ygcHUaFxkG20Lma7lQ3u__rv_qGbwXln9PAdjoD7MEWf_VNMIVdUbeddmVclj0WZkEz8Agiwv4M</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2193602320</pqid></control><display><type>article</type><title>Recommendations of the Spanish Antibiogram Committee (COESANT) for selecting antimicrobial agents and concentrations for in vitro susceptibility studies using automated systems</title><source>Elsevier ScienceDirect Journals Complete</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><creator>Cantón, Rafael ; Oliver, Antonio ; Alós, Juan Ignacio ; de Benito, Natividad ; Bou, Germán ; Campos, José ; Calvo, Jorge ; Canut, Andrés ; Castillo, Javier ; Cercenado, Emilia ; Domínguez, Maria Ángeles ; Fernández-Cuenca, Felipe ; Guinea, Jesús ; Larrosa, Nieves ; Liñares, Josefina ; López-Cerero, Lorena ; López-Navas, Antonio ; Marco, Francesc ; Mirelis, Beatriz ; Moreno-Romo, Miguel Ángel ; Morosini, María Isabel ; Navarro, Ferran ; Oteo, Jesús ; Pascual, Álvaro ; Pérez-Trallero, Emilio ; Pérez-Vázquez, María ; Soriano, Alex ; Torres, Carmen ; Vila, Jordi ; Martínez-Martínez, Luis</creator><creatorcontrib>Cantón, Rafael ; Oliver, Antonio ; Alós, Juan Ignacio ; de Benito, Natividad ; Bou, Germán ; Campos, José ; Calvo, Jorge ; Canut, Andrés ; Castillo, Javier ; Cercenado, Emilia ; Domínguez, Maria Ángeles ; Fernández-Cuenca, Felipe ; Guinea, Jesús ; Larrosa, Nieves ; Liñares, Josefina ; López-Cerero, Lorena ; López-Navas, Antonio ; Marco, Francesc ; Mirelis, Beatriz ; Moreno-Romo, Miguel Ángel ; Morosini, María Isabel ; Navarro, Ferran ; Oteo, Jesús ; Pascual, Álvaro ; Pérez-Trallero, Emilio ; Pérez-Vázquez, María ; Soriano, Alex ; Torres, Carmen ; Vila, Jordi ; Martínez-Martínez, Luis</creatorcontrib><description>Abstract Automated antimicrobial susceptibility testing devices are widely implemented in clinical microbiology laboratories in Spain, mainly using EUCAST (European Committee on Antimicrobial Susceptibility Testing) breakpoints. In 2007, a group of experts published recommendations for including antimicrobial agents and selecting concentrations in these systems. Under the patronage of the Spanish Antibiogram Committee ( Comité Español del Antibiograma , COESANT) and the Study Group on Mechanisms of Action and Resistance to Antimicrobial Agents (GEMARA) from the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC), and aligned with the Spanish National Plan against Antimicrobial Resistance (PRAN), a group of experts have updated this document. The main modifications from the previous version comprise the inclusion of new antimicrobial agents, adaptation of the ranges of concentrations to cover the EUCAST breakpoints and epidemiological cut-off values (ECOFFs), and the inference of new resistance mechanisms. This proposal should be considered by different manufacturers and users when designing new panels or cards. In addition, recommendations for selective reporting are also included. With this approach, the implementation of EUCAST breakpoints will be easier, increasing the quality of antimicrobial susceptibility testing data and their microbiological interpretation. It will also benefit epidemiological surveillance studies as well as the clinical use of antimicrobials aligned with antimicrobial stewardship programs.</description><identifier>ISSN: 0213-005X</identifier><identifier>EISSN: 1578-1852</identifier><identifier>EISSN: 2529-993X</identifier><identifier>DOI: 10.1016/j.eimc.2019.01.017</identifier><identifier>PMID: 30878313</identifier><language>eng</language><publisher>Spain: Elsevier España, S.L.U</publisher><subject>Antibiogram ; Antibiograma ; Automated susceptibility testing systems ; CMI ; Concentraciones mínimas antimicrobianas ; Infectious Disease ; MICs ; Minimum antimicrobial concentrations ; Sistemas automáticos de detección de sensibilidad</subject><ispartof>Enfermedades infecciosas y microbiologia clinica, 2020-04, Vol.38 (4), p.182-187</ispartof><rights>Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica</rights><rights>2019 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica</rights><rights>Copyright © 2019 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c455t-e55bc3395095c7e202ff0cefd2f545b61dea3d663abcb6ea9d1df4aa8a19fab03</citedby><cites>FETCH-LOGICAL-c455t-e55bc3395095c7e202ff0cefd2f545b61dea3d663abcb6ea9d1df4aa8a19fab03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0213005X19301351$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65534</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30878313$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cantón, Rafael</creatorcontrib><creatorcontrib>Oliver, Antonio</creatorcontrib><creatorcontrib>Alós, Juan Ignacio</creatorcontrib><creatorcontrib>de Benito, Natividad</creatorcontrib><creatorcontrib>Bou, Germán</creatorcontrib><creatorcontrib>Campos, José</creatorcontrib><creatorcontrib>Calvo, Jorge</creatorcontrib><creatorcontrib>Canut, Andrés</creatorcontrib><creatorcontrib>Castillo, Javier</creatorcontrib><creatorcontrib>Cercenado, Emilia</creatorcontrib><creatorcontrib>Domínguez, Maria Ángeles</creatorcontrib><creatorcontrib>Fernández-Cuenca, Felipe</creatorcontrib><creatorcontrib>Guinea, Jesús</creatorcontrib><creatorcontrib>Larrosa, Nieves</creatorcontrib><creatorcontrib>Liñares, Josefina</creatorcontrib><creatorcontrib>López-Cerero, Lorena</creatorcontrib><creatorcontrib>López-Navas, Antonio</creatorcontrib><creatorcontrib>Marco, Francesc</creatorcontrib><creatorcontrib>Mirelis, Beatriz</creatorcontrib><creatorcontrib>Moreno-Romo, Miguel Ángel</creatorcontrib><creatorcontrib>Morosini, María Isabel</creatorcontrib><creatorcontrib>Navarro, Ferran</creatorcontrib><creatorcontrib>Oteo, Jesús</creatorcontrib><creatorcontrib>Pascual, Álvaro</creatorcontrib><creatorcontrib>Pérez-Trallero, Emilio</creatorcontrib><creatorcontrib>Pérez-Vázquez, María</creatorcontrib><creatorcontrib>Soriano, Alex</creatorcontrib><creatorcontrib>Torres, Carmen</creatorcontrib><creatorcontrib>Vila, Jordi</creatorcontrib><creatorcontrib>Martínez-Martínez, Luis</creatorcontrib><title>Recommendations of the Spanish Antibiogram Committee (COESANT) for selecting antimicrobial agents and concentrations for in vitro susceptibility studies using automated systems</title><title>Enfermedades infecciosas y microbiologia clinica</title><addtitle>Enferm Infecc Microbiol Clin</addtitle><description>Abstract Automated antimicrobial susceptibility testing devices are widely implemented in clinical microbiology laboratories in Spain, mainly using EUCAST (European Committee on Antimicrobial Susceptibility Testing) breakpoints. In 2007, a group of experts published recommendations for including antimicrobial agents and selecting concentrations in these systems. Under the patronage of the Spanish Antibiogram Committee ( Comité Español del Antibiograma , COESANT) and the Study Group on Mechanisms of Action and Resistance to Antimicrobial Agents (GEMARA) from the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC), and aligned with the Spanish National Plan against Antimicrobial Resistance (PRAN), a group of experts have updated this document. The main modifications from the previous version comprise the inclusion of new antimicrobial agents, adaptation of the ranges of concentrations to cover the EUCAST breakpoints and epidemiological cut-off values (ECOFFs), and the inference of new resistance mechanisms. This proposal should be considered by different manufacturers and users when designing new panels or cards. In addition, recommendations for selective reporting are also included. With this approach, the implementation of EUCAST breakpoints will be easier, increasing the quality of antimicrobial susceptibility testing data and their microbiological interpretation. It will also benefit epidemiological surveillance studies as well as the clinical use of antimicrobials aligned with antimicrobial stewardship programs.</description><subject>Antibiogram</subject><subject>Antibiograma</subject><subject>Automated susceptibility testing systems</subject><subject>CMI</subject><subject>Concentraciones mínimas antimicrobianas</subject><subject>Infectious Disease</subject><subject>MICs</subject><subject>Minimum antimicrobial concentrations</subject><subject>Sistemas automáticos de detección de sensibilidad</subject><issn>0213-005X</issn><issn>1578-1852</issn><issn>2529-993X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9UsuKFDEULURx2tEfcCFZjotq8-jUA0RomvEBgwP2CO5CKrnVk7YqaXNTA_1XfqIpu3XhQrgQEs45N_ecWxQvGV0yyqo3-yW40Sw5Ze2Sslz1o2LBZN2UrJH8cbGgnImSUvntoniGuKeUSyHE0-JC0KZuBBOL4ucXMGEcwVudXPBIQk_SPZDtQXuH92Ttk-tc2EU9kk0GupQAyNXm9nq7_nz3mvQhEoQBTHJ-R3RGj87E0Dk9EL0DnzA_WmKCN_kSz01mlvPkwaUYCE5o4DC3GVw6EkyTdYBkwt-KUwqjTmAJHjHBiM-LJ70eEF6cz8vi6_vru83H8ub2w6fN-qY0KylTCVJ2RohW0laaGjjlfU8N9Jb3ciW7ilnQwlaV0J3pKtCtZbZfad1o1va6o-KyuDrpHmL4MQEmNbr8z2HQHsKEirNWVJQLPkP5CZoHR4zQq0N0o45Hxaiak1J7NSel5qQUZbnqTHp11p-6Eexfyp9oMuDtCQB5ygcHUaFxkG20Lma7lQ3u__rv_qGbwXln9PAdjoD7MEWf_VNMIVdUbeddmVclj0WZkEz8Agiwv4M</recordid><startdate>20200401</startdate><enddate>20200401</enddate><creator>Cantón, Rafael</creator><creator>Oliver, Antonio</creator><creator>Alós, Juan Ignacio</creator><creator>de Benito, Natividad</creator><creator>Bou, Germán</creator><creator>Campos, José</creator><creator>Calvo, Jorge</creator><creator>Canut, Andrés</creator><creator>Castillo, Javier</creator><creator>Cercenado, Emilia</creator><creator>Domínguez, Maria Ángeles</creator><creator>Fernández-Cuenca, Felipe</creator><creator>Guinea, Jesús</creator><creator>Larrosa, Nieves</creator><creator>Liñares, Josefina</creator><creator>López-Cerero, Lorena</creator><creator>López-Navas, Antonio</creator><creator>Marco, Francesc</creator><creator>Mirelis, Beatriz</creator><creator>Moreno-Romo, Miguel Ángel</creator><creator>Morosini, María Isabel</creator><creator>Navarro, Ferran</creator><creator>Oteo, Jesús</creator><creator>Pascual, Álvaro</creator><creator>Pérez-Trallero, Emilio</creator><creator>Pérez-Vázquez, María</creator><creator>Soriano, Alex</creator><creator>Torres, Carmen</creator><creator>Vila, Jordi</creator><creator>Martínez-Martínez, Luis</creator><general>Elsevier España, S.L.U</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20200401</creationdate><title>Recommendations of the Spanish Antibiogram Committee (COESANT) for selecting antimicrobial agents and concentrations for in vitro susceptibility studies using automated systems</title><author>Cantón, Rafael ; Oliver, Antonio ; Alós, Juan Ignacio ; de Benito, Natividad ; Bou, Germán ; Campos, José ; Calvo, Jorge ; Canut, Andrés ; Castillo, Javier ; Cercenado, Emilia ; Domínguez, Maria Ángeles ; Fernández-Cuenca, Felipe ; Guinea, Jesús ; Larrosa, Nieves ; Liñares, Josefina ; López-Cerero, Lorena ; López-Navas, Antonio ; Marco, Francesc ; Mirelis, Beatriz ; Moreno-Romo, Miguel Ángel ; Morosini, María Isabel ; Navarro, Ferran ; Oteo, Jesús ; Pascual, Álvaro ; Pérez-Trallero, Emilio ; Pérez-Vázquez, María ; Soriano, Alex ; Torres, Carmen ; Vila, Jordi ; Martínez-Martínez, Luis</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c455t-e55bc3395095c7e202ff0cefd2f545b61dea3d663abcb6ea9d1df4aa8a19fab03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Antibiogram</topic><topic>Antibiograma</topic><topic>Automated susceptibility testing systems</topic><topic>CMI</topic><topic>Concentraciones mínimas antimicrobianas</topic><topic>Infectious Disease</topic><topic>MICs</topic><topic>Minimum antimicrobial concentrations</topic><topic>Sistemas automáticos de detección de sensibilidad</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cantón, Rafael</creatorcontrib><creatorcontrib>Oliver, Antonio</creatorcontrib><creatorcontrib>Alós, Juan Ignacio</creatorcontrib><creatorcontrib>de Benito, Natividad</creatorcontrib><creatorcontrib>Bou, Germán</creatorcontrib><creatorcontrib>Campos, José</creatorcontrib><creatorcontrib>Calvo, Jorge</creatorcontrib><creatorcontrib>Canut, Andrés</creatorcontrib><creatorcontrib>Castillo, Javier</creatorcontrib><creatorcontrib>Cercenado, Emilia</creatorcontrib><creatorcontrib>Domínguez, Maria Ángeles</creatorcontrib><creatorcontrib>Fernández-Cuenca, Felipe</creatorcontrib><creatorcontrib>Guinea, Jesús</creatorcontrib><creatorcontrib>Larrosa, Nieves</creatorcontrib><creatorcontrib>Liñares, Josefina</creatorcontrib><creatorcontrib>López-Cerero, Lorena</creatorcontrib><creatorcontrib>López-Navas, Antonio</creatorcontrib><creatorcontrib>Marco, Francesc</creatorcontrib><creatorcontrib>Mirelis, Beatriz</creatorcontrib><creatorcontrib>Moreno-Romo, Miguel Ángel</creatorcontrib><creatorcontrib>Morosini, María Isabel</creatorcontrib><creatorcontrib>Navarro, Ferran</creatorcontrib><creatorcontrib>Oteo, Jesús</creatorcontrib><creatorcontrib>Pascual, Álvaro</creatorcontrib><creatorcontrib>Pérez-Trallero, Emilio</creatorcontrib><creatorcontrib>Pérez-Vázquez, María</creatorcontrib><creatorcontrib>Soriano, Alex</creatorcontrib><creatorcontrib>Torres, Carmen</creatorcontrib><creatorcontrib>Vila, Jordi</creatorcontrib><creatorcontrib>Martínez-Martínez, Luis</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Enfermedades infecciosas y microbiologia clinica</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cantón, Rafael</au><au>Oliver, Antonio</au><au>Alós, Juan Ignacio</au><au>de Benito, Natividad</au><au>Bou, Germán</au><au>Campos, José</au><au>Calvo, Jorge</au><au>Canut, Andrés</au><au>Castillo, Javier</au><au>Cercenado, Emilia</au><au>Domínguez, Maria Ángeles</au><au>Fernández-Cuenca, Felipe</au><au>Guinea, Jesús</au><au>Larrosa, Nieves</au><au>Liñares, Josefina</au><au>López-Cerero, Lorena</au><au>López-Navas, Antonio</au><au>Marco, Francesc</au><au>Mirelis, Beatriz</au><au>Moreno-Romo, Miguel Ángel</au><au>Morosini, María Isabel</au><au>Navarro, Ferran</au><au>Oteo, Jesús</au><au>Pascual, Álvaro</au><au>Pérez-Trallero, Emilio</au><au>Pérez-Vázquez, María</au><au>Soriano, Alex</au><au>Torres, Carmen</au><au>Vila, Jordi</au><au>Martínez-Martínez, Luis</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Recommendations of the Spanish Antibiogram Committee (COESANT) for selecting antimicrobial agents and concentrations for in vitro susceptibility studies using automated systems</atitle><jtitle>Enfermedades infecciosas y microbiologia clinica</jtitle><addtitle>Enferm Infecc Microbiol Clin</addtitle><date>2020-04-01</date><risdate>2020</risdate><volume>38</volume><issue>4</issue><spage>182</spage><epage>187</epage><pages>182-187</pages><issn>0213-005X</issn><eissn>1578-1852</eissn><eissn>2529-993X</eissn><abstract>Abstract Automated antimicrobial susceptibility testing devices are widely implemented in clinical microbiology laboratories in Spain, mainly using EUCAST (European Committee on Antimicrobial Susceptibility Testing) breakpoints. In 2007, a group of experts published recommendations for including antimicrobial agents and selecting concentrations in these systems. Under the patronage of the Spanish Antibiogram Committee ( Comité Español del Antibiograma , COESANT) and the Study Group on Mechanisms of Action and Resistance to Antimicrobial Agents (GEMARA) from the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC), and aligned with the Spanish National Plan against Antimicrobial Resistance (PRAN), a group of experts have updated this document. The main modifications from the previous version comprise the inclusion of new antimicrobial agents, adaptation of the ranges of concentrations to cover the EUCAST breakpoints and epidemiological cut-off values (ECOFFs), and the inference of new resistance mechanisms. This proposal should be considered by different manufacturers and users when designing new panels or cards. In addition, recommendations for selective reporting are also included. With this approach, the implementation of EUCAST breakpoints will be easier, increasing the quality of antimicrobial susceptibility testing data and their microbiological interpretation. It will also benefit epidemiological surveillance studies as well as the clinical use of antimicrobials aligned with antimicrobial stewardship programs.</abstract><cop>Spain</cop><pub>Elsevier España, S.L.U</pub><pmid>30878313</pmid><doi>10.1016/j.eimc.2019.01.017</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0213-005X
ispartof Enfermedades infecciosas y microbiologia clinica, 2020-04, Vol.38 (4), p.182-187
issn 0213-005X
1578-1852
2529-993X
language eng
recordid cdi_proquest_miscellaneous_2193602320
source Elsevier ScienceDirect Journals Complete; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection
subjects Antibiogram
Antibiograma
Automated susceptibility testing systems
CMI
Concentraciones mínimas antimicrobianas
Infectious Disease
MICs
Minimum antimicrobial concentrations
Sistemas automáticos de detección de sensibilidad
title Recommendations of the Spanish Antibiogram Committee (COESANT) for selecting antimicrobial agents and concentrations for in vitro susceptibility studies using automated systems
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-20T21%3A38%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Recommendations%20of%20the%20Spanish%20Antibiogram%20Committee%20(COESANT)%20for%20selecting%20antimicrobial%20agents%20and%20concentrations%20for%20in%20vitro%20susceptibility%20studies%20using%20automated%20systems&rft.jtitle=Enfermedades%20infecciosas%20y%20microbiologia%20clinica&rft.au=Cant%C3%B3n,%20Rafael&rft.date=2020-04-01&rft.volume=38&rft.issue=4&rft.spage=182&rft.epage=187&rft.pages=182-187&rft.issn=0213-005X&rft.eissn=1578-1852&rft_id=info:doi/10.1016/j.eimc.2019.01.017&rft_dat=%3Cproquest_cross%3E2193602320%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2193602320&rft_id=info:pmid/30878313&rft_els_id=1_s2_0_S0213005X19301351&rfr_iscdi=true