Fricke xylenol glycine gel dosimeter for in vivo dosimetry at extended treatment distance

Fricke xylenol gelatin with glycine (FXGGly) as gel dosimeter was investigated for in vivo dosimetry at extended source-to-surface distance (eSSD) and validated with optically stimulated luminescence dosimeters (OSLD). FXGGly dosimeter was calibrated with a low dose rate of 10 cGy/min at eSSD and ev...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied radiation and isotopes 2019-03, Vol.145, p.217-222
Hauptverfasser: Ebenezer Suman Babu, S., Mohamathu Rafic, K., Timothy Peace, B.S., Jose Solomon Raj, L., Paul Ravindran, B.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 222
container_issue
container_start_page 217
container_title Applied radiation and isotopes
container_volume 145
creator Ebenezer Suman Babu, S.
Mohamathu Rafic, K.
Timothy Peace, B.S.
Jose Solomon Raj, L.
Paul Ravindran, B.
description Fricke xylenol gelatin with glycine (FXGGly) as gel dosimeter was investigated for in vivo dosimetry at extended source-to-surface distance (eSSD) and validated with optically stimulated luminescence dosimeters (OSLD). FXGGly dosimeter was calibrated with a low dose rate of 10 cGy/min at eSSD and evaluated using anthropomorphic phantom simulating the actual treatment scenario. The FXGGly dosimeter was demonstrated as a suitable in vivo dosimeter for total body irradiation at eSSD with desirable dosimetric accuracy (± 2%) in comparison with OSLD or ionization chamber. •FXG-Glycine gel dosimeters for in-vivo dosimetry at extended SSD.•Profile measurements with gel dosimeters agree with ionization chamber values.•Gel measurements were comparable to OSLD on anthropomorphic phantom.
doi_str_mv 10.1016/j.apradiso.2018.09.028
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2185878174</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0969804317314859</els_id><sourcerecordid>2185878174</sourcerecordid><originalsourceid>FETCH-LOGICAL-c368t-c72b8ff024a73e91fd6f4cad394677c17c8c84af681aa25bad60d8c12d90f05d3</originalsourceid><addsrcrecordid>eNqFkD1v2zAQhomiRe18_AWDYxcpR0oWya2FUTcBDHRJhk4ETR4NupLokrQR__sqcNy10wGH572Ph5AFg5oB6x72tTkk40KONQcma1A1cPmBzJkUvFIS4COZg-pUJaFtZuQm5z0AtFLxz2TWgFCSL2FOfq1TsL-Rvp57HGNPd_3ZhhHpDnvqYg4DFkzUx0TDSE_hFK_ddKamUHwtODp0tCQ0ZcCx0OmmYkaLd-STN33G-_d6S17W359Xj9Xm54-n1bdNZZtOlsoKvpXeA2-NaFAx7zrfWuMa1XZCWCastLI1vpPMGL7cGteBk5Zxp8DD0jW35Mtl7iHFP0fMRQ8hW-x7M2I8Zs2ZXEohmWgntLugNsWcE3p9SGEw6awZ6Deteq-vWvWbVg1KT1qn4OJ9x3E7oPsXu3qcgK8XAKdPTwGTzjbgZMGFhLZoF8P_dvwFGzKOZw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2185878174</pqid></control><display><type>article</type><title>Fricke xylenol glycine gel dosimeter for in vivo dosimetry at extended treatment distance</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Ebenezer Suman Babu, S. ; Mohamathu Rafic, K. ; Timothy Peace, B.S. ; Jose Solomon Raj, L. ; Paul Ravindran, B.</creator><creatorcontrib>Ebenezer Suman Babu, S. ; Mohamathu Rafic, K. ; Timothy Peace, B.S. ; Jose Solomon Raj, L. ; Paul Ravindran, B.</creatorcontrib><description>Fricke xylenol gelatin with glycine (FXGGly) as gel dosimeter was investigated for in vivo dosimetry at extended source-to-surface distance (eSSD) and validated with optically stimulated luminescence dosimeters (OSLD). FXGGly dosimeter was calibrated with a low dose rate of 10 cGy/min at eSSD and evaluated using anthropomorphic phantom simulating the actual treatment scenario. The FXGGly dosimeter was demonstrated as a suitable in vivo dosimeter for total body irradiation at eSSD with desirable dosimetric accuracy (± 2%) in comparison with OSLD or ionization chamber. •FXG-Glycine gel dosimeters for in-vivo dosimetry at extended SSD.•Profile measurements with gel dosimeters agree with ionization chamber values.•Gel measurements were comparable to OSLD on anthropomorphic phantom.</description><identifier>ISSN: 0969-8043</identifier><identifier>EISSN: 1872-9800</identifier><identifier>DOI: 10.1016/j.apradiso.2018.09.028</identifier><identifier>PMID: 30798250</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><ispartof>Applied radiation and isotopes, 2019-03, Vol.145, p.217-222</ispartof><rights>2018 Elsevier Ltd</rights><rights>Copyright © 2018 Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c368t-c72b8ff024a73e91fd6f4cad394677c17c8c84af681aa25bad60d8c12d90f05d3</citedby><cites>FETCH-LOGICAL-c368t-c72b8ff024a73e91fd6f4cad394677c17c8c84af681aa25bad60d8c12d90f05d3</cites><orcidid>0000-0003-4035-974X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.apradiso.2018.09.028$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3548,27923,27924,45994</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30798250$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ebenezer Suman Babu, S.</creatorcontrib><creatorcontrib>Mohamathu Rafic, K.</creatorcontrib><creatorcontrib>Timothy Peace, B.S.</creatorcontrib><creatorcontrib>Jose Solomon Raj, L.</creatorcontrib><creatorcontrib>Paul Ravindran, B.</creatorcontrib><title>Fricke xylenol glycine gel dosimeter for in vivo dosimetry at extended treatment distance</title><title>Applied radiation and isotopes</title><addtitle>Appl Radiat Isot</addtitle><description>Fricke xylenol gelatin with glycine (FXGGly) as gel dosimeter was investigated for in vivo dosimetry at extended source-to-surface distance (eSSD) and validated with optically stimulated luminescence dosimeters (OSLD). FXGGly dosimeter was calibrated with a low dose rate of 10 cGy/min at eSSD and evaluated using anthropomorphic phantom simulating the actual treatment scenario. The FXGGly dosimeter was demonstrated as a suitable in vivo dosimeter for total body irradiation at eSSD with desirable dosimetric accuracy (± 2%) in comparison with OSLD or ionization chamber. •FXG-Glycine gel dosimeters for in-vivo dosimetry at extended SSD.•Profile measurements with gel dosimeters agree with ionization chamber values.•Gel measurements were comparable to OSLD on anthropomorphic phantom.</description><issn>0969-8043</issn><issn>1872-9800</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNqFkD1v2zAQhomiRe18_AWDYxcpR0oWya2FUTcBDHRJhk4ETR4NupLokrQR__sqcNy10wGH572Ph5AFg5oB6x72tTkk40KONQcma1A1cPmBzJkUvFIS4COZg-pUJaFtZuQm5z0AtFLxz2TWgFCSL2FOfq1TsL-Rvp57HGNPd_3ZhhHpDnvqYg4DFkzUx0TDSE_hFK_ddKamUHwtODp0tCQ0ZcCx0OmmYkaLd-STN33G-_d6S17W359Xj9Xm54-n1bdNZZtOlsoKvpXeA2-NaFAx7zrfWuMa1XZCWCastLI1vpPMGL7cGteBk5Zxp8DD0jW35Mtl7iHFP0fMRQ8hW-x7M2I8Zs2ZXEohmWgntLugNsWcE3p9SGEw6awZ6Deteq-vWvWbVg1KT1qn4OJ9x3E7oPsXu3qcgK8XAKdPTwGTzjbgZMGFhLZoF8P_dvwFGzKOZw</recordid><startdate>201903</startdate><enddate>201903</enddate><creator>Ebenezer Suman Babu, S.</creator><creator>Mohamathu Rafic, K.</creator><creator>Timothy Peace, B.S.</creator><creator>Jose Solomon Raj, L.</creator><creator>Paul Ravindran, B.</creator><general>Elsevier Ltd</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-4035-974X</orcidid></search><sort><creationdate>201903</creationdate><title>Fricke xylenol glycine gel dosimeter for in vivo dosimetry at extended treatment distance</title><author>Ebenezer Suman Babu, S. ; Mohamathu Rafic, K. ; Timothy Peace, B.S. ; Jose Solomon Raj, L. ; Paul Ravindran, B.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c368t-c72b8ff024a73e91fd6f4cad394677c17c8c84af681aa25bad60d8c12d90f05d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ebenezer Suman Babu, S.</creatorcontrib><creatorcontrib>Mohamathu Rafic, K.</creatorcontrib><creatorcontrib>Timothy Peace, B.S.</creatorcontrib><creatorcontrib>Jose Solomon Raj, L.</creatorcontrib><creatorcontrib>Paul Ravindran, B.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Applied radiation and isotopes</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ebenezer Suman Babu, S.</au><au>Mohamathu Rafic, K.</au><au>Timothy Peace, B.S.</au><au>Jose Solomon Raj, L.</au><au>Paul Ravindran, B.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fricke xylenol glycine gel dosimeter for in vivo dosimetry at extended treatment distance</atitle><jtitle>Applied radiation and isotopes</jtitle><addtitle>Appl Radiat Isot</addtitle><date>2019-03</date><risdate>2019</risdate><volume>145</volume><spage>217</spage><epage>222</epage><pages>217-222</pages><issn>0969-8043</issn><eissn>1872-9800</eissn><abstract>Fricke xylenol gelatin with glycine (FXGGly) as gel dosimeter was investigated for in vivo dosimetry at extended source-to-surface distance (eSSD) and validated with optically stimulated luminescence dosimeters (OSLD). FXGGly dosimeter was calibrated with a low dose rate of 10 cGy/min at eSSD and evaluated using anthropomorphic phantom simulating the actual treatment scenario. The FXGGly dosimeter was demonstrated as a suitable in vivo dosimeter for total body irradiation at eSSD with desirable dosimetric accuracy (± 2%) in comparison with OSLD or ionization chamber. •FXG-Glycine gel dosimeters for in-vivo dosimetry at extended SSD.•Profile measurements with gel dosimeters agree with ionization chamber values.•Gel measurements were comparable to OSLD on anthropomorphic phantom.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>30798250</pmid><doi>10.1016/j.apradiso.2018.09.028</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0003-4035-974X</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0969-8043
ispartof Applied radiation and isotopes, 2019-03, Vol.145, p.217-222
issn 0969-8043
1872-9800
language eng
recordid cdi_proquest_miscellaneous_2185878174
source ScienceDirect Journals (5 years ago - present)
title Fricke xylenol glycine gel dosimeter for in vivo dosimetry at extended treatment distance
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T17%3A41%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fricke%20xylenol%20glycine%20gel%20dosimeter%20for%20in%20vivo%20dosimetry%20at%20extended%20treatment%20distance&rft.jtitle=Applied%20radiation%20and%20isotopes&rft.au=Ebenezer%20Suman%20Babu,%20S.&rft.date=2019-03&rft.volume=145&rft.spage=217&rft.epage=222&rft.pages=217-222&rft.issn=0969-8043&rft.eissn=1872-9800&rft_id=info:doi/10.1016/j.apradiso.2018.09.028&rft_dat=%3Cproquest_cross%3E2185878174%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2185878174&rft_id=info:pmid/30798250&rft_els_id=S0969804317314859&rfr_iscdi=true