Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases

Today, the only potentially curative option in patients with colorectal liver metastases is surgery. However, liver resection is feasible in less than 20% of patients. Surgery has been widely used in association with radiofrequency, cryotherapy, or microwaves to expand the number of treatments perfo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Visualized Experiments 2019-01 (143)
Hauptverfasser: Dupre, Aurélien, Melodelima, David, Perol, David, Chen, Yao, Vincenot, Jérémy, Chapelon, Jean-Yves, Rivoire, Michel
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 143
container_start_page
container_title Journal of Visualized Experiments
container_volume
creator Dupre, Aurélien
Melodelima, David
Perol, David
Chen, Yao
Vincenot, Jérémy
Chapelon, Jean-Yves
Rivoire, Michel
description Today, the only potentially curative option in patients with colorectal liver metastases is surgery. However, liver resection is feasible in less than 20% of patients. Surgery has been widely used in association with radiofrequency, cryotherapy, or microwaves to expand the number of treatments performed with a curative intent. Nevertheless, several limitations have been documented when using these techniques (i.e., a traumatic puncture of the parenchyma, a limited size of lesions, and an inability to monitor the treatment in real-time).High-intensity focused ultrasound (HIFU) technology can achieve precise ablations of biological tissues without incisions or radiation. Current HIFU devices are based on an extracorporeal approach with limited access to the liver. We have developed a HIFU device designed for intraoperative use. The use of a toroidal transducer enables an ablation rate (10 cm3·min-1) higher than any other treatment and is independent of perfusion. The feasibility, safety, and accuracy of intraoperative HIFU ablation were evaluated during an ablate-and-resect prospective study. This clinical phase I and IIa study was performed in patients undergoing hepatectomy for liver metastases. The HIFU treatment was performed on healthy tissue scheduled for resection.Liver metastases measuring less than 20 mm will be targeted during phase IIb (currently ongoing). This set-up allows the real-time evaluation of HIFU ablation while protecting participating patients from any adverse effects related to this new technique. Fifteen patients were included in phase I–IIa and 30 HIFU ablations were safely created within 40 s and with a precision of 1–2 mm. The average dimensions of the HIFU ablations were 27.5 x 21.0 mm2, corresponding to a volume of approximately 7.5 cm3. The aim of the ongoing phase IIb is to ablate metastases of less than 20 mm in diameter with a 5 mm margin.
doi_str_mv 10.3791/57964
format Article
fullrecord <record><control><sourceid>proquest_223</sourceid><recordid>TN_cdi_proquest_miscellaneous_2179456184</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2179456184</sourcerecordid><originalsourceid>FETCH-LOGICAL-c257t-6b7250c33b4f38a4b89defac1db78fe9a55cc2a68d38fd937acbe4e8ce8435023</originalsourceid><addsrcrecordid>eNpNkE1LAzEQhoMoVqt_wIPkInhwNbvZj-xR1Gqh4kEFb8tsdtKmbJOa7Bb6K_zLpraKMPDO4XkG5iXkNGbXvCjjm6wo83SPHMVlyiImio_9f_uAHHs_ZyxPWCYOyYCzXIikZEfk62EFbQ-dtoZaRbsZ0hGC17Vudbe-oq-gcJNgGnorZe9ArjcgGDo2nQO7RBfsFdInPZ1F2nRofDDpyMreY0Pf20B52wf_HldaIlXW0TeHwTJTOgmqo8_YgQ-D_oQcKGg9nu5ySN5HD293T9Hk5XF8dzuJZJIVXZTXRZIxyXmdKi4grUXZoAIZN3UhFJaQZVImkIuGC9WUvABZY4pCokh5xhI-JJfbu0tnP3v0XbXQXmLbgkHb-yqJizLN8jjgQ3KxRaWz3jtU1dLpBbh1FbNq0331033gzncn-3qBzR_1W3YAzrbA3K6wmtvemfDizv4GYLiJ3A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2179456184</pqid></control><display><type>article</type><title>Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases</title><source>Journal of Visualized Experiments : JoVE</source><creator>Dupre, Aurélien ; Melodelima, David ; Perol, David ; Chen, Yao ; Vincenot, Jérémy ; Chapelon, Jean-Yves ; Rivoire, Michel</creator><creatorcontrib>Dupre, Aurélien ; Melodelima, David ; Perol, David ; Chen, Yao ; Vincenot, Jérémy ; Chapelon, Jean-Yves ; Rivoire, Michel</creatorcontrib><description>Today, the only potentially curative option in patients with colorectal liver metastases is surgery. However, liver resection is feasible in less than 20% of patients. Surgery has been widely used in association with radiofrequency, cryotherapy, or microwaves to expand the number of treatments performed with a curative intent. Nevertheless, several limitations have been documented when using these techniques (i.e., a traumatic puncture of the parenchyma, a limited size of lesions, and an inability to monitor the treatment in real-time).High-intensity focused ultrasound (HIFU) technology can achieve precise ablations of biological tissues without incisions or radiation. Current HIFU devices are based on an extracorporeal approach with limited access to the liver. We have developed a HIFU device designed for intraoperative use. The use of a toroidal transducer enables an ablation rate (10 cm3·min-1) higher than any other treatment and is independent of perfusion. The feasibility, safety, and accuracy of intraoperative HIFU ablation were evaluated during an ablate-and-resect prospective study. This clinical phase I and IIa study was performed in patients undergoing hepatectomy for liver metastases. The HIFU treatment was performed on healthy tissue scheduled for resection.Liver metastases measuring less than 20 mm will be targeted during phase IIb (currently ongoing). This set-up allows the real-time evaluation of HIFU ablation while protecting participating patients from any adverse effects related to this new technique. Fifteen patients were included in phase I–IIa and 30 HIFU ablations were safely created within 40 s and with a precision of 1–2 mm. The average dimensions of the HIFU ablations were 27.5 x 21.0 mm2, corresponding to a volume of approximately 7.5 cm3. The aim of the ongoing phase IIb is to ablate metastases of less than 20 mm in diameter with a 5 mm margin.</description><identifier>ISSN: 1940-087X</identifier><identifier>EISSN: 1940-087X</identifier><identifier>DOI: 10.3791/57964</identifier><identifier>PMID: 30688290</identifier><language>eng</language><publisher>United States: MyJove Corporation</publisher><subject>Adult ; Cancer Research ; Feasibility Studies ; High-Intensity Focused Ultrasound Ablation - methods ; Humans ; Liver Neoplasms - complications ; Liver Neoplasms - pathology ; Middle Aged ; Neoplasm Metastasis ; Prospective Studies</subject><ispartof>Journal of Visualized Experiments, 2019-01 (143)</ispartof><rights>Copyright © 2019, Journal of Visualized Experiments</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c257t-6b7250c33b4f38a4b89defac1db78fe9a55cc2a68d38fd937acbe4e8ce8435023</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.jove.com/files/email_thumbs/57964.png</thumbnail><link.rule.ids>314,776,780,3830,27901,27902</link.rule.ids><linktorsrc>$$Uhttp://dx.doi.org/10.3791/57964$$EView_record_in_Journal_of_Visualized_Experiments$$FView_record_in_$$GJournal_of_Visualized_Experiments</linktorsrc><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30688290$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Dupre, Aurélien</creatorcontrib><creatorcontrib>Melodelima, David</creatorcontrib><creatorcontrib>Perol, David</creatorcontrib><creatorcontrib>Chen, Yao</creatorcontrib><creatorcontrib>Vincenot, Jérémy</creatorcontrib><creatorcontrib>Chapelon, Jean-Yves</creatorcontrib><creatorcontrib>Rivoire, Michel</creatorcontrib><title>Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases</title><title>Journal of Visualized Experiments</title><addtitle>J Vis Exp</addtitle><description>Today, the only potentially curative option in patients with colorectal liver metastases is surgery. However, liver resection is feasible in less than 20% of patients. Surgery has been widely used in association with radiofrequency, cryotherapy, or microwaves to expand the number of treatments performed with a curative intent. Nevertheless, several limitations have been documented when using these techniques (i.e., a traumatic puncture of the parenchyma, a limited size of lesions, and an inability to monitor the treatment in real-time).High-intensity focused ultrasound (HIFU) technology can achieve precise ablations of biological tissues without incisions or radiation. Current HIFU devices are based on an extracorporeal approach with limited access to the liver. We have developed a HIFU device designed for intraoperative use. The use of a toroidal transducer enables an ablation rate (10 cm3·min-1) higher than any other treatment and is independent of perfusion. The feasibility, safety, and accuracy of intraoperative HIFU ablation were evaluated during an ablate-and-resect prospective study. This clinical phase I and IIa study was performed in patients undergoing hepatectomy for liver metastases. The HIFU treatment was performed on healthy tissue scheduled for resection.Liver metastases measuring less than 20 mm will be targeted during phase IIb (currently ongoing). This set-up allows the real-time evaluation of HIFU ablation while protecting participating patients from any adverse effects related to this new technique. Fifteen patients were included in phase I–IIa and 30 HIFU ablations were safely created within 40 s and with a precision of 1–2 mm. The average dimensions of the HIFU ablations were 27.5 x 21.0 mm2, corresponding to a volume of approximately 7.5 cm3. The aim of the ongoing phase IIb is to ablate metastases of less than 20 mm in diameter with a 5 mm margin.</description><subject>Adult</subject><subject>Cancer Research</subject><subject>Feasibility Studies</subject><subject>High-Intensity Focused Ultrasound Ablation - methods</subject><subject>Humans</subject><subject>Liver Neoplasms - complications</subject><subject>Liver Neoplasms - pathology</subject><subject>Middle Aged</subject><subject>Neoplasm Metastasis</subject><subject>Prospective Studies</subject><issn>1940-087X</issn><issn>1940-087X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpNkE1LAzEQhoMoVqt_wIPkInhwNbvZj-xR1Gqh4kEFb8tsdtKmbJOa7Bb6K_zLpraKMPDO4XkG5iXkNGbXvCjjm6wo83SPHMVlyiImio_9f_uAHHs_ZyxPWCYOyYCzXIikZEfk62EFbQ-dtoZaRbsZ0hGC17Vudbe-oq-gcJNgGnorZe9ArjcgGDo2nQO7RBfsFdInPZ1F2nRofDDpyMreY0Pf20B52wf_HldaIlXW0TeHwTJTOgmqo8_YgQ-D_oQcKGg9nu5ySN5HD293T9Hk5XF8dzuJZJIVXZTXRZIxyXmdKi4grUXZoAIZN3UhFJaQZVImkIuGC9WUvABZY4pCokh5xhI-JJfbu0tnP3v0XbXQXmLbgkHb-yqJizLN8jjgQ3KxRaWz3jtU1dLpBbh1FbNq0331033gzncn-3qBzR_1W3YAzrbA3K6wmtvemfDizv4GYLiJ3A</recordid><startdate>20190109</startdate><enddate>20190109</enddate><creator>Dupre, Aurélien</creator><creator>Melodelima, David</creator><creator>Perol, David</creator><creator>Chen, Yao</creator><creator>Vincenot, Jérémy</creator><creator>Chapelon, Jean-Yves</creator><creator>Rivoire, Michel</creator><general>MyJove Corporation</general><scope>AULCJ</scope><scope>DRUMS</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20190109</creationdate><title>Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases</title><author>Dupre, Aurélien ; Melodelima, David ; Perol, David ; Chen, Yao ; Vincenot, Jérémy ; Chapelon, Jean-Yves ; Rivoire, Michel</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c257t-6b7250c33b4f38a4b89defac1db78fe9a55cc2a68d38fd937acbe4e8ce8435023</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Adult</topic><topic>Cancer Research</topic><topic>Feasibility Studies</topic><topic>High-Intensity Focused Ultrasound Ablation - methods</topic><topic>Humans</topic><topic>Liver Neoplasms - complications</topic><topic>Liver Neoplasms - pathology</topic><topic>Middle Aged</topic><topic>Neoplasm Metastasis</topic><topic>Prospective Studies</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Dupre, Aurélien</creatorcontrib><creatorcontrib>Melodelima, David</creatorcontrib><creatorcontrib>Perol, David</creatorcontrib><creatorcontrib>Chen, Yao</creatorcontrib><creatorcontrib>Vincenot, Jérémy</creatorcontrib><creatorcontrib>Chapelon, Jean-Yves</creatorcontrib><creatorcontrib>Rivoire, Michel</creatorcontrib><collection>JoVE Journal: Cancer Research</collection><collection>JoVE Open Access</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of Visualized Experiments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Dupre, Aurélien</au><au>Melodelima, David</au><au>Perol, David</au><au>Chen, Yao</au><au>Vincenot, Jérémy</au><au>Chapelon, Jean-Yves</au><au>Rivoire, Michel</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases</atitle><jtitle>Journal of Visualized Experiments</jtitle><addtitle>J Vis Exp</addtitle><date>2019-01-09</date><risdate>2019</risdate><issue>143</issue><issn>1940-087X</issn><eissn>1940-087X</eissn><abstract>Today, the only potentially curative option in patients with colorectal liver metastases is surgery. However, liver resection is feasible in less than 20% of patients. Surgery has been widely used in association with radiofrequency, cryotherapy, or microwaves to expand the number of treatments performed with a curative intent. Nevertheless, several limitations have been documented when using these techniques (i.e., a traumatic puncture of the parenchyma, a limited size of lesions, and an inability to monitor the treatment in real-time).High-intensity focused ultrasound (HIFU) technology can achieve precise ablations of biological tissues without incisions or radiation. Current HIFU devices are based on an extracorporeal approach with limited access to the liver. We have developed a HIFU device designed for intraoperative use. The use of a toroidal transducer enables an ablation rate (10 cm3·min-1) higher than any other treatment and is independent of perfusion. The feasibility, safety, and accuracy of intraoperative HIFU ablation were evaluated during an ablate-and-resect prospective study. This clinical phase I and IIa study was performed in patients undergoing hepatectomy for liver metastases. The HIFU treatment was performed on healthy tissue scheduled for resection.Liver metastases measuring less than 20 mm will be targeted during phase IIb (currently ongoing). This set-up allows the real-time evaluation of HIFU ablation while protecting participating patients from any adverse effects related to this new technique. Fifteen patients were included in phase I–IIa and 30 HIFU ablations were safely created within 40 s and with a precision of 1–2 mm. The average dimensions of the HIFU ablations were 27.5 x 21.0 mm2, corresponding to a volume of approximately 7.5 cm3. The aim of the ongoing phase IIb is to ablate metastases of less than 20 mm in diameter with a 5 mm margin.</abstract><cop>United States</cop><pub>MyJove Corporation</pub><pmid>30688290</pmid><doi>10.3791/57964</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1940-087X
ispartof Journal of Visualized Experiments, 2019-01 (143)
issn 1940-087X
1940-087X
language eng
recordid cdi_proquest_miscellaneous_2179456184
source Journal of Visualized Experiments : JoVE
subjects Adult
Cancer Research
Feasibility Studies
High-Intensity Focused Ultrasound Ablation - methods
Humans
Liver Neoplasms - complications
Liver Neoplasms - pathology
Middle Aged
Neoplasm Metastasis
Prospective Studies
title Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T00%3A52%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_223&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20the%20Feasibility,%20Safety,%20and%20Accuracy%20of%20an%20Intraoperative%20High-intensity%20Focused%20Ultrasound%20Device%20for%20Treating%20Liver%20Metastases&rft.jtitle=Journal%20of%20Visualized%20Experiments&rft.au=Dupre,%20Aur%C3%A9lien&rft.date=2019-01-09&rft.issue=143&rft.issn=1940-087X&rft.eissn=1940-087X&rft_id=info:doi/10.3791/57964&rft_dat=%3Cproquest_223%3E2179456184%3C/proquest_223%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2179456184&rft_id=info:pmid/30688290&rfr_iscdi=true