Determination of aluminium using different techniques based on the Al(III)-morin complex

Three different methods for the determination of Al(III) in aqueous samples were compared. The different described procedures were based on the formation of the Al(III)-morin complex. UV–Vis spectrophotometry, spectrofluorimetry and differential pulse adsorptive stripping voltammetry (DPAdSV) techni...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2019-05, Vol.196, p.131-136
Hauptverfasser: Domínguez-Renedo, Olga, Marta Navarro-Cuñado, A., Ventas-Romay, Eduardo, Asunción Alonso-Lomillo, M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 136
container_issue
container_start_page 131
container_title Talanta (Oxford)
container_volume 196
creator Domínguez-Renedo, Olga
Marta Navarro-Cuñado, A.
Ventas-Romay, Eduardo
Asunción Alonso-Lomillo, M.
description Three different methods for the determination of Al(III) in aqueous samples were compared. The different described procedures were based on the formation of the Al(III)-morin complex. UV–Vis spectrophotometry, spectrofluorimetry and differential pulse adsorptive stripping voltammetry (DPAdSV) techniques were compared under optimized experimental conditions. The DPAdSV method showed a better performance for the analysis of Al(III) in terms of capability of detection (70 nM) in comparison with the value obtained for UV–Vis spectrophotometric (300 nM) and spectrofluorimetic (110 nM) techniques. Thus, DPAdSV method was selected for the analysis of aluminium in river, tap and bottled water samples under the following optimized experimental conditions: pH = 4.4, deposition potential = +243 mV, deposition time = 210 s, giving satisfactory results. [Display omitted] •Voltammetric determination of Al(III) using a GCE.•High sensitivity and selectivity.•Comparison of electrochemical, UV–VIS and spectrofluorimetic methods.•Successful determination of Al(III) in real samples.
doi_str_mv 10.1016/j.talanta.2018.12.048
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2179451148</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0039914018313122</els_id><sourcerecordid>2179451148</sourcerecordid><originalsourceid>FETCH-LOGICAL-c365t-71750d9e8296d1b1caf0d31f855063679ffa62e224c0a655cb33134a7db154f93</originalsourceid><addsrcrecordid>eNqFkMtuFDEQRS0EIpPAJ4C8DIvuVNntfqxQFAiMFIkNSOwst10mHvVjsN0R-fv0MAPbrEolnVuPw9g7hBIB66tdmc1gpmxKAdiWKEqo2hdsg20jC6ka-ZJtAGRXdFjBGTtPaQcAQoJ8zc4k1K2Uldiwn58oUxzDZHKYJz57boZlbcMy8iWF6Rd3wXuKNGWeyd5P4fdCifcmkeNrIN8Tvx4ut9vth2KcY5i4ncf9QH_esFfeDInenuoF-3H7-fvN1-Lu25ftzfVdYWWtctFgo8B11IqudtijNR6cRN8qBbWsm857UwsSorJgaqVsLyXKyjSuR1X5Tl6wy-PcfZwPp2U9hmRpWN3QvCQtsOkqhVi1K6qOqI1zSpG83scwmvioEfRBqt7pk1R9kKpRaPibe39asfQjuf-pfxZX4OMRoPXRh0BRJxtosuRCJJu1m8MzK54AH0uKcA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2179451148</pqid></control><display><type>article</type><title>Determination of aluminium using different techniques based on the Al(III)-morin complex</title><source>Elsevier ScienceDirect Journals</source><creator>Domínguez-Renedo, Olga ; Marta Navarro-Cuñado, A. ; Ventas-Romay, Eduardo ; Asunción Alonso-Lomillo, M.</creator><creatorcontrib>Domínguez-Renedo, Olga ; Marta Navarro-Cuñado, A. ; Ventas-Romay, Eduardo ; Asunción Alonso-Lomillo, M.</creatorcontrib><description>Three different methods for the determination of Al(III) in aqueous samples were compared. The different described procedures were based on the formation of the Al(III)-morin complex. UV–Vis spectrophotometry, spectrofluorimetry and differential pulse adsorptive stripping voltammetry (DPAdSV) techniques were compared under optimized experimental conditions. The DPAdSV method showed a better performance for the analysis of Al(III) in terms of capability of detection (70 nM) in comparison with the value obtained for UV–Vis spectrophotometric (300 nM) and spectrofluorimetic (110 nM) techniques. Thus, DPAdSV method was selected for the analysis of aluminium in river, tap and bottled water samples under the following optimized experimental conditions: pH = 4.4, deposition potential = +243 mV, deposition time = 210 s, giving satisfactory results. [Display omitted] •Voltammetric determination of Al(III) using a GCE.•High sensitivity and selectivity.•Comparison of electrochemical, UV–VIS and spectrofluorimetic methods.•Successful determination of Al(III) in real samples.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/j.talanta.2018.12.048</identifier><identifier>PMID: 30683342</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Aluminium ; Fluorescence ; Morin ; Stripping voltammetry ; UV–Vis spectroscopy ; Water samples</subject><ispartof>Talanta (Oxford), 2019-05, Vol.196, p.131-136</ispartof><rights>2018 Elsevier B.V.</rights><rights>Copyright © 2018 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c365t-71750d9e8296d1b1caf0d31f855063679ffa62e224c0a655cb33134a7db154f93</citedby><cites>FETCH-LOGICAL-c365t-71750d9e8296d1b1caf0d31f855063679ffa62e224c0a655cb33134a7db154f93</cites><orcidid>0000-0002-5714-3956</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0039914018313122$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30683342$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Domínguez-Renedo, Olga</creatorcontrib><creatorcontrib>Marta Navarro-Cuñado, A.</creatorcontrib><creatorcontrib>Ventas-Romay, Eduardo</creatorcontrib><creatorcontrib>Asunción Alonso-Lomillo, M.</creatorcontrib><title>Determination of aluminium using different techniques based on the Al(III)-morin complex</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>Three different methods for the determination of Al(III) in aqueous samples were compared. The different described procedures were based on the formation of the Al(III)-morin complex. UV–Vis spectrophotometry, spectrofluorimetry and differential pulse adsorptive stripping voltammetry (DPAdSV) techniques were compared under optimized experimental conditions. The DPAdSV method showed a better performance for the analysis of Al(III) in terms of capability of detection (70 nM) in comparison with the value obtained for UV–Vis spectrophotometric (300 nM) and spectrofluorimetic (110 nM) techniques. Thus, DPAdSV method was selected for the analysis of aluminium in river, tap and bottled water samples under the following optimized experimental conditions: pH = 4.4, deposition potential = +243 mV, deposition time = 210 s, giving satisfactory results. [Display omitted] •Voltammetric determination of Al(III) using a GCE.•High sensitivity and selectivity.•Comparison of electrochemical, UV–VIS and spectrofluorimetic methods.•Successful determination of Al(III) in real samples.</description><subject>Aluminium</subject><subject>Fluorescence</subject><subject>Morin</subject><subject>Stripping voltammetry</subject><subject>UV–Vis spectroscopy</subject><subject>Water samples</subject><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNqFkMtuFDEQRS0EIpPAJ4C8DIvuVNntfqxQFAiMFIkNSOwst10mHvVjsN0R-fv0MAPbrEolnVuPw9g7hBIB66tdmc1gpmxKAdiWKEqo2hdsg20jC6ka-ZJtAGRXdFjBGTtPaQcAQoJ8zc4k1K2Uldiwn58oUxzDZHKYJz57boZlbcMy8iWF6Rd3wXuKNGWeyd5P4fdCifcmkeNrIN8Tvx4ut9vth2KcY5i4ncf9QH_esFfeDInenuoF-3H7-fvN1-Lu25ftzfVdYWWtctFgo8B11IqudtijNR6cRN8qBbWsm857UwsSorJgaqVsLyXKyjSuR1X5Tl6wy-PcfZwPp2U9hmRpWN3QvCQtsOkqhVi1K6qOqI1zSpG83scwmvioEfRBqt7pk1R9kKpRaPibe39asfQjuf-pfxZX4OMRoPXRh0BRJxtosuRCJJu1m8MzK54AH0uKcA</recordid><startdate>20190501</startdate><enddate>20190501</enddate><creator>Domínguez-Renedo, Olga</creator><creator>Marta Navarro-Cuñado, A.</creator><creator>Ventas-Romay, Eduardo</creator><creator>Asunción Alonso-Lomillo, M.</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-5714-3956</orcidid></search><sort><creationdate>20190501</creationdate><title>Determination of aluminium using different techniques based on the Al(III)-morin complex</title><author>Domínguez-Renedo, Olga ; Marta Navarro-Cuñado, A. ; Ventas-Romay, Eduardo ; Asunción Alonso-Lomillo, M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c365t-71750d9e8296d1b1caf0d31f855063679ffa62e224c0a655cb33134a7db154f93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Aluminium</topic><topic>Fluorescence</topic><topic>Morin</topic><topic>Stripping voltammetry</topic><topic>UV–Vis spectroscopy</topic><topic>Water samples</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Domínguez-Renedo, Olga</creatorcontrib><creatorcontrib>Marta Navarro-Cuñado, A.</creatorcontrib><creatorcontrib>Ventas-Romay, Eduardo</creatorcontrib><creatorcontrib>Asunción Alonso-Lomillo, M.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Domínguez-Renedo, Olga</au><au>Marta Navarro-Cuñado, A.</au><au>Ventas-Romay, Eduardo</au><au>Asunción Alonso-Lomillo, M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of aluminium using different techniques based on the Al(III)-morin complex</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>2019-05-01</date><risdate>2019</risdate><volume>196</volume><spage>131</spage><epage>136</epage><pages>131-136</pages><issn>0039-9140</issn><eissn>1873-3573</eissn><abstract>Three different methods for the determination of Al(III) in aqueous samples were compared. The different described procedures were based on the formation of the Al(III)-morin complex. UV–Vis spectrophotometry, spectrofluorimetry and differential pulse adsorptive stripping voltammetry (DPAdSV) techniques were compared under optimized experimental conditions. The DPAdSV method showed a better performance for the analysis of Al(III) in terms of capability of detection (70 nM) in comparison with the value obtained for UV–Vis spectrophotometric (300 nM) and spectrofluorimetic (110 nM) techniques. Thus, DPAdSV method was selected for the analysis of aluminium in river, tap and bottled water samples under the following optimized experimental conditions: pH = 4.4, deposition potential = +243 mV, deposition time = 210 s, giving satisfactory results. [Display omitted] •Voltammetric determination of Al(III) using a GCE.•High sensitivity and selectivity.•Comparison of electrochemical, UV–VIS and spectrofluorimetic methods.•Successful determination of Al(III) in real samples.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>30683342</pmid><doi>10.1016/j.talanta.2018.12.048</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0002-5714-3956</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 2019-05, Vol.196, p.131-136
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_2179451148
source Elsevier ScienceDirect Journals
subjects Aluminium
Fluorescence
Morin
Stripping voltammetry
UV–Vis spectroscopy
Water samples
title Determination of aluminium using different techniques based on the Al(III)-morin complex
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-13T03%3A48%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20aluminium%20using%20different%20techniques%20based%20on%20the%20Al(III)-morin%20complex&rft.jtitle=Talanta%20(Oxford)&rft.au=Dom%C3%ADnguez-Renedo,%20Olga&rft.date=2019-05-01&rft.volume=196&rft.spage=131&rft.epage=136&rft.pages=131-136&rft.issn=0039-9140&rft.eissn=1873-3573&rft_id=info:doi/10.1016/j.talanta.2018.12.048&rft_dat=%3Cproquest_cross%3E2179451148%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2179451148&rft_id=info:pmid/30683342&rft_els_id=S0039914018313122&rfr_iscdi=true