Normalized averaged range (nAR), a robust quantification method for MPIO-content
[Display omitted] •Micron-sized Iron-oxide particles are useful negative-contrast T2* MRI markers.•The normalized average range is a novel quantification method for Iron-oxide particles.•It can detect small differences between concentrations of iron-oxide particles.•It is relatively robust to most p...
Gespeichert in:
Veröffentlicht in: | Journal of magnetic resonance (1997) 2019-03, Vol.300, p.18-27 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 27 |
---|---|
container_issue | |
container_start_page | 18 |
container_title | Journal of magnetic resonance (1997) |
container_volume | 300 |
creator | Naeyaert, Maarten Roose, Dimitri Mai, Zhenhua Keliris, Aneta Sijbers, Jan Van der Linden, Annemie Verhoye, Marleen |
description | [Display omitted]
•Micron-sized Iron-oxide particles are useful negative-contrast T2* MRI markers.•The normalized average range is a novel quantification method for Iron-oxide particles.•It can detect small differences between concentrations of iron-oxide particles.•It is relatively robust to most processing steps.•It works on positive and negative contrast images.
Micron-sized paramagnetic iron oxide particles (MPIO) are commonly used as contrast agents in magnetic resonance imaging (MRI) that produce negative contrast enhancement, i.e. darkening, on T2*-weighted images. However, estimation and quantification of MPIO in vivo is still challenging. This limitation mainly arises from smearing and displacement of the negative contrast of the MPIO, so-called blooming, potentially leading to false-positive detection. Further, the bias field induced by the MR coils also hinders visualization and quantification of the MPIO. To mitigate these drawbacks, a positive contrast image can be generated, for example by using a frequency offset technique, which can significantly improve the accuracy of quantification methods. In this research, we introduce the normalized average range (nAR) as a new way to quantify the relative MPIO content within a study. The method compares the average value of test ROIs to that of a control ROI in range filtered images. The nAR can be used on both positive and negative contrast images.
The nAR was tested on agar phantoms containing various MPIO concentrations, and on a rostral migration model for MPIO labeled stem cells in mice. The amount of MPIO was quantified for biased and unbiased data, and both for positive and negative contrast images. In addition, the presence of MPIOs in the olfactory bulb was verified by histology.
The results show the nAR can indicate the presence and relative content of MPIO for both negative and positive images. However, the nAR showed slightly higher sensitivity in optimized positive contrast images compared to negative contrast images. In all cases, the bias field played a minor role in the quantification, making debiasing less of a concern. The dependency of the nAR values on the MPIO content in the ROI was further validated histologically. Thus, the nAR provides a robust and reliable tool for quantification of MPIO in mice. |
doi_str_mv | 10.1016/j.jmr.2018.12.019 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2179418619</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1090780718303501</els_id><sourcerecordid>2179418619</sourcerecordid><originalsourceid>FETCH-LOGICAL-c305t-b8aafe1e9c136a884be9bf58df4b0f59fe32a074b95aa60d4b5d34eb0a3c4f6b3</originalsourceid><addsrcrecordid>eNp9kEtP3TAQha2qiFf5Ad1UWYJEwkyejrpCCFokXqratTV2xtRXNzHYDlL76wlc2iWrOYvvHGk-IT4jFAjYnqyK1RiKElAWWBaA_Qexi9C3Ocim_fiaIe8kdDtiL8YVAGLTwbbYqaCVtSybXXF348NIa_eXh4yeOND9EgJN95wdTqc_jo4zyoLXc0zZ40xTctYZSs5P2cjptx8y60N2fXd5mxs_JZ7SJ7FlaR354O3ui18X5z_PvudXt98uz06vclNBk3ItiSwj9warlqSsNffaNnKwtQbb9JarkqCrdd8QtTDUuhmqmjVQZWrb6mpfHG52H4J_nDkmNbpoeL2mif0cVYldX6NssV9Q3KAm-BgDW_UQ3Ejhj0JQLyLVSi0i1YtIhaWC186Xt_lZjzz8b_wztwBfNwAvTz45Dioax5PhwQU2SQ3evTP_DLgIg-0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2179418619</pqid></control><display><type>article</type><title>Normalized averaged range (nAR), a robust quantification method for MPIO-content</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Naeyaert, Maarten ; Roose, Dimitri ; Mai, Zhenhua ; Keliris, Aneta ; Sijbers, Jan ; Van der Linden, Annemie ; Verhoye, Marleen</creator><creatorcontrib>Naeyaert, Maarten ; Roose, Dimitri ; Mai, Zhenhua ; Keliris, Aneta ; Sijbers, Jan ; Van der Linden, Annemie ; Verhoye, Marleen</creatorcontrib><description>[Display omitted]
•Micron-sized Iron-oxide particles are useful negative-contrast T2* MRI markers.•The normalized average range is a novel quantification method for Iron-oxide particles.•It can detect small differences between concentrations of iron-oxide particles.•It is relatively robust to most processing steps.•It works on positive and negative contrast images.
Micron-sized paramagnetic iron oxide particles (MPIO) are commonly used as contrast agents in magnetic resonance imaging (MRI) that produce negative contrast enhancement, i.e. darkening, on T2*-weighted images. However, estimation and quantification of MPIO in vivo is still challenging. This limitation mainly arises from smearing and displacement of the negative contrast of the MPIO, so-called blooming, potentially leading to false-positive detection. Further, the bias field induced by the MR coils also hinders visualization and quantification of the MPIO. To mitigate these drawbacks, a positive contrast image can be generated, for example by using a frequency offset technique, which can significantly improve the accuracy of quantification methods. In this research, we introduce the normalized average range (nAR) as a new way to quantify the relative MPIO content within a study. The method compares the average value of test ROIs to that of a control ROI in range filtered images. The nAR can be used on both positive and negative contrast images.
The nAR was tested on agar phantoms containing various MPIO concentrations, and on a rostral migration model for MPIO labeled stem cells in mice. The amount of MPIO was quantified for biased and unbiased data, and both for positive and negative contrast images. In addition, the presence of MPIOs in the olfactory bulb was verified by histology.
The results show the nAR can indicate the presence and relative content of MPIO for both negative and positive images. However, the nAR showed slightly higher sensitivity in optimized positive contrast images compared to negative contrast images. In all cases, the bias field played a minor role in the quantification, making debiasing less of a concern. The dependency of the nAR values on the MPIO content in the ROI was further validated histologically. Thus, the nAR provides a robust and reliable tool for quantification of MPIO in mice.</description><identifier>ISSN: 1090-7807</identifier><identifier>EISSN: 1096-0856</identifier><identifier>DOI: 10.1016/j.jmr.2018.12.019</identifier><identifier>PMID: 30684825</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Artefact reduction ; MPIO ; Positive contrast ; Quantification ; Stem cell tracking</subject><ispartof>Journal of magnetic resonance (1997), 2019-03, Vol.300, p.18-27</ispartof><rights>2019 Elsevier Inc.</rights><rights>Copyright © 2019 Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c305t-b8aafe1e9c136a884be9bf58df4b0f59fe32a074b95aa60d4b5d34eb0a3c4f6b3</cites><orcidid>0000-0002-7452-5534</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.jmr.2018.12.019$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30684825$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Naeyaert, Maarten</creatorcontrib><creatorcontrib>Roose, Dimitri</creatorcontrib><creatorcontrib>Mai, Zhenhua</creatorcontrib><creatorcontrib>Keliris, Aneta</creatorcontrib><creatorcontrib>Sijbers, Jan</creatorcontrib><creatorcontrib>Van der Linden, Annemie</creatorcontrib><creatorcontrib>Verhoye, Marleen</creatorcontrib><title>Normalized averaged range (nAR), a robust quantification method for MPIO-content</title><title>Journal of magnetic resonance (1997)</title><addtitle>J Magn Reson</addtitle><description>[Display omitted]
•Micron-sized Iron-oxide particles are useful negative-contrast T2* MRI markers.•The normalized average range is a novel quantification method for Iron-oxide particles.•It can detect small differences between concentrations of iron-oxide particles.•It is relatively robust to most processing steps.•It works on positive and negative contrast images.
Micron-sized paramagnetic iron oxide particles (MPIO) are commonly used as contrast agents in magnetic resonance imaging (MRI) that produce negative contrast enhancement, i.e. darkening, on T2*-weighted images. However, estimation and quantification of MPIO in vivo is still challenging. This limitation mainly arises from smearing and displacement of the negative contrast of the MPIO, so-called blooming, potentially leading to false-positive detection. Further, the bias field induced by the MR coils also hinders visualization and quantification of the MPIO. To mitigate these drawbacks, a positive contrast image can be generated, for example by using a frequency offset technique, which can significantly improve the accuracy of quantification methods. In this research, we introduce the normalized average range (nAR) as a new way to quantify the relative MPIO content within a study. The method compares the average value of test ROIs to that of a control ROI in range filtered images. The nAR can be used on both positive and negative contrast images.
The nAR was tested on agar phantoms containing various MPIO concentrations, and on a rostral migration model for MPIO labeled stem cells in mice. The amount of MPIO was quantified for biased and unbiased data, and both for positive and negative contrast images. In addition, the presence of MPIOs in the olfactory bulb was verified by histology.
The results show the nAR can indicate the presence and relative content of MPIO for both negative and positive images. However, the nAR showed slightly higher sensitivity in optimized positive contrast images compared to negative contrast images. In all cases, the bias field played a minor role in the quantification, making debiasing less of a concern. The dependency of the nAR values on the MPIO content in the ROI was further validated histologically. Thus, the nAR provides a robust and reliable tool for quantification of MPIO in mice.</description><subject>Artefact reduction</subject><subject>MPIO</subject><subject>Positive contrast</subject><subject>Quantification</subject><subject>Stem cell tracking</subject><issn>1090-7807</issn><issn>1096-0856</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp9kEtP3TAQha2qiFf5Ad1UWYJEwkyejrpCCFokXqratTV2xtRXNzHYDlL76wlc2iWrOYvvHGk-IT4jFAjYnqyK1RiKElAWWBaA_Qexi9C3Ocim_fiaIe8kdDtiL8YVAGLTwbbYqaCVtSybXXF348NIa_eXh4yeOND9EgJN95wdTqc_jo4zyoLXc0zZ40xTctYZSs5P2cjptx8y60N2fXd5mxs_JZ7SJ7FlaR354O3ui18X5z_PvudXt98uz06vclNBk3ItiSwj9warlqSsNffaNnKwtQbb9JarkqCrdd8QtTDUuhmqmjVQZWrb6mpfHG52H4J_nDkmNbpoeL2mif0cVYldX6NssV9Q3KAm-BgDW_UQ3Ejhj0JQLyLVSi0i1YtIhaWC186Xt_lZjzz8b_wztwBfNwAvTz45Dioax5PhwQU2SQ3evTP_DLgIg-0</recordid><startdate>201903</startdate><enddate>201903</enddate><creator>Naeyaert, Maarten</creator><creator>Roose, Dimitri</creator><creator>Mai, Zhenhua</creator><creator>Keliris, Aneta</creator><creator>Sijbers, Jan</creator><creator>Van der Linden, Annemie</creator><creator>Verhoye, Marleen</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-7452-5534</orcidid></search><sort><creationdate>201903</creationdate><title>Normalized averaged range (nAR), a robust quantification method for MPIO-content</title><author>Naeyaert, Maarten ; Roose, Dimitri ; Mai, Zhenhua ; Keliris, Aneta ; Sijbers, Jan ; Van der Linden, Annemie ; Verhoye, Marleen</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c305t-b8aafe1e9c136a884be9bf58df4b0f59fe32a074b95aa60d4b5d34eb0a3c4f6b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Artefact reduction</topic><topic>MPIO</topic><topic>Positive contrast</topic><topic>Quantification</topic><topic>Stem cell tracking</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Naeyaert, Maarten</creatorcontrib><creatorcontrib>Roose, Dimitri</creatorcontrib><creatorcontrib>Mai, Zhenhua</creatorcontrib><creatorcontrib>Keliris, Aneta</creatorcontrib><creatorcontrib>Sijbers, Jan</creatorcontrib><creatorcontrib>Van der Linden, Annemie</creatorcontrib><creatorcontrib>Verhoye, Marleen</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of magnetic resonance (1997)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Naeyaert, Maarten</au><au>Roose, Dimitri</au><au>Mai, Zhenhua</au><au>Keliris, Aneta</au><au>Sijbers, Jan</au><au>Van der Linden, Annemie</au><au>Verhoye, Marleen</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Normalized averaged range (nAR), a robust quantification method for MPIO-content</atitle><jtitle>Journal of magnetic resonance (1997)</jtitle><addtitle>J Magn Reson</addtitle><date>2019-03</date><risdate>2019</risdate><volume>300</volume><spage>18</spage><epage>27</epage><pages>18-27</pages><issn>1090-7807</issn><eissn>1096-0856</eissn><abstract>[Display omitted]
•Micron-sized Iron-oxide particles are useful negative-contrast T2* MRI markers.•The normalized average range is a novel quantification method for Iron-oxide particles.•It can detect small differences between concentrations of iron-oxide particles.•It is relatively robust to most processing steps.•It works on positive and negative contrast images.
Micron-sized paramagnetic iron oxide particles (MPIO) are commonly used as contrast agents in magnetic resonance imaging (MRI) that produce negative contrast enhancement, i.e. darkening, on T2*-weighted images. However, estimation and quantification of MPIO in vivo is still challenging. This limitation mainly arises from smearing and displacement of the negative contrast of the MPIO, so-called blooming, potentially leading to false-positive detection. Further, the bias field induced by the MR coils also hinders visualization and quantification of the MPIO. To mitigate these drawbacks, a positive contrast image can be generated, for example by using a frequency offset technique, which can significantly improve the accuracy of quantification methods. In this research, we introduce the normalized average range (nAR) as a new way to quantify the relative MPIO content within a study. The method compares the average value of test ROIs to that of a control ROI in range filtered images. The nAR can be used on both positive and negative contrast images.
The nAR was tested on agar phantoms containing various MPIO concentrations, and on a rostral migration model for MPIO labeled stem cells in mice. The amount of MPIO was quantified for biased and unbiased data, and both for positive and negative contrast images. In addition, the presence of MPIOs in the olfactory bulb was verified by histology.
The results show the nAR can indicate the presence and relative content of MPIO for both negative and positive images. However, the nAR showed slightly higher sensitivity in optimized positive contrast images compared to negative contrast images. In all cases, the bias field played a minor role in the quantification, making debiasing less of a concern. The dependency of the nAR values on the MPIO content in the ROI was further validated histologically. Thus, the nAR provides a robust and reliable tool for quantification of MPIO in mice.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>30684825</pmid><doi>10.1016/j.jmr.2018.12.019</doi><tpages>10</tpages><orcidid>https://orcid.org/0000-0002-7452-5534</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1090-7807 |
ispartof | Journal of magnetic resonance (1997), 2019-03, Vol.300, p.18-27 |
issn | 1090-7807 1096-0856 |
language | eng |
recordid | cdi_proquest_miscellaneous_2179418619 |
source | Elsevier ScienceDirect Journals Complete |
subjects | Artefact reduction MPIO Positive contrast Quantification Stem cell tracking |
title | Normalized averaged range (nAR), a robust quantification method for MPIO-content |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T06%3A02%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Normalized%20averaged%20range%20(nAR),%20a%20robust%20quantification%20method%20for%20MPIO-content&rft.jtitle=Journal%20of%20magnetic%20resonance%20(1997)&rft.au=Naeyaert,%20Maarten&rft.date=2019-03&rft.volume=300&rft.spage=18&rft.epage=27&rft.pages=18-27&rft.issn=1090-7807&rft.eissn=1096-0856&rft_id=info:doi/10.1016/j.jmr.2018.12.019&rft_dat=%3Cproquest_cross%3E2179418619%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2179418619&rft_id=info:pmid/30684825&rft_els_id=S1090780718303501&rfr_iscdi=true |