A porous organic polymer with magnetic nanoparticles on a chip array for preconcentration of platinum(IV), gold(III) and bismuth(III) prior to their on-line quantitation by ICP-MS
A chip-based array is described for magnetic solid-phase microextraction (MSPME) of the ions of Pt, Au and Bi. Magnetic porous organic polymers (MOPs) prepared from magnetite nanoparticles and 1,3,5-tris(4-aminophenyl)benzene are introduced as a novel adsorbent. Eight solid phase extraction columns...
Gespeichert in:
Veröffentlicht in: | Mikrochimica acta (1966) 2019-02, Vol.186 (2), p.107-8, Article 107 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 8 |
---|---|
container_issue | 2 |
container_start_page | 107 |
container_title | Mikrochimica acta (1966) |
container_volume | 186 |
creator | Chen, Zhenna Chen, Beibei He, Man Wang, Han Hu, Bin |
description | A chip-based array is described for magnetic solid-phase microextraction (MSPME) of the ions of Pt, Au and Bi. Magnetic porous organic polymers (MOPs) prepared from magnetite nanoparticles and 1,3,5-tris(4-aminophenyl)benzene are introduced as a novel adsorbent. Eight solid phase extraction columns packed with MOPs were integrated in parallel on a microfluidic chip for array microextraction. After elution with a 12% (m/v) solution of cysteamine hydrochloride (pH 8.0), the eluent is introduced into an ICP-MS instrument for quantification. Under the optimized conditions, the limits of detection for Pt, Au and Bi are 8.6, 4.4 and 3.4 ng L
−1
, respectively. The sample throughput is 7 h
−1
, and the adsorption capacities are 32, 24 and 24 μg mg
−1
for Pt, Au and Bi, respectively. The method was validated by the determination of Bi in a certified reference material (GSH-1A; human hair), and the values obtained coincided with the certified value. This method was also applied to the determination of Pt, Au and Bi in (spiked) urine and cell samples, and good recoveries (85.8–113%) were achieved. The method is highly sensitive and has a high throughput and a low sample/reagent consumption (with 500 HeLa cells consumed).
Graphical abstract
Schematic presentation of the magnetic packed column, microfluidic chip, and online chip-based MSPME-ICPMS system. Design sketch of the online system: microextraction unit (blue lines), microvalves (black lines), outlet channels (yellow lines), permanent magnets (red), urine and cell samples. |
doi_str_mv | 10.1007/s00604-018-3139-1 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2179353868</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2166927694</sourcerecordid><originalsourceid>FETCH-LOGICAL-c372t-ba849b871bbde0135343430fe6a569aab412e5bdc5719f71975505eba6f2ea4e3</originalsourceid><addsrcrecordid>eNp1kV2L1DAUhoMo7rj6A7yRgDezsNWkSZPp5TL4UVhR8OO2JO3pTJY26SYpy_wu_6Bn6aogSAg5OXnOe5K8hLzk7A1nTL9NjCkmC8Z3heCiLvgjsuFSqKJiWjwmG8ZKVQilyzPyLKUbxrhWpXxKzgRTQstabsjPKzqHGJZEQzwY7zrcjqcJIr1z-Ugnc_CQMeuND7OJGI6ArKeGdkc3UxOjOdEhRDpH6ILvwOdoskMiDHQeMfTLtG1-XFzSQxj7bdM0F9T4nlqXpiUf18QcHUrkQPMRXET9YnQe6O1ifHZ51bMn2uy_FJ--PidPBjMmePGwnpPv7999238srj9_aPZX10UndJkLa3aytjvNre2BcVEJiYMNoEylamOs5CVUtu8qzesBp64qVoE1aijBSBDnZLvqzjHcLpByO7nUwTgaD_hjbcl1jao7tUP09T_oTViix9shpVRdalVLpPhKdTGkFGFo8d2TiaeWs_be0XZ1tEVH23tHW441rx6UFztB_6fit4UIlCuQ8MgfIP5t_X_VX3jdrHg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2166927694</pqid></control><display><type>article</type><title>A porous organic polymer with magnetic nanoparticles on a chip array for preconcentration of platinum(IV), gold(III) and bismuth(III) prior to their on-line quantitation by ICP-MS</title><source>SpringerLink Journals - AutoHoldings</source><creator>Chen, Zhenna ; Chen, Beibei ; He, Man ; Wang, Han ; Hu, Bin</creator><creatorcontrib>Chen, Zhenna ; Chen, Beibei ; He, Man ; Wang, Han ; Hu, Bin</creatorcontrib><description>A chip-based array is described for magnetic solid-phase microextraction (MSPME) of the ions of Pt, Au and Bi. Magnetic porous organic polymers (MOPs) prepared from magnetite nanoparticles and 1,3,5-tris(4-aminophenyl)benzene are introduced as a novel adsorbent. Eight solid phase extraction columns packed with MOPs were integrated in parallel on a microfluidic chip for array microextraction. After elution with a 12% (m/v) solution of cysteamine hydrochloride (pH 8.0), the eluent is introduced into an ICP-MS instrument for quantification. Under the optimized conditions, the limits of detection for Pt, Au and Bi are 8.6, 4.4 and 3.4 ng L
−1
, respectively. The sample throughput is 7 h
−1
, and the adsorption capacities are 32, 24 and 24 μg mg
−1
for Pt, Au and Bi, respectively. The method was validated by the determination of Bi in a certified reference material (GSH-1A; human hair), and the values obtained coincided with the certified value. This method was also applied to the determination of Pt, Au and Bi in (spiked) urine and cell samples, and good recoveries (85.8–113%) were achieved. The method is highly sensitive and has a high throughput and a low sample/reagent consumption (with 500 HeLa cells consumed).
Graphical abstract
Schematic presentation of the magnetic packed column, microfluidic chip, and online chip-based MSPME-ICPMS system. Design sketch of the online system: microextraction unit (blue lines), microvalves (black lines), outlet channels (yellow lines), permanent magnets (red), urine and cell samples.</description><identifier>ISSN: 0026-3672</identifier><identifier>EISSN: 1436-5073</identifier><identifier>DOI: 10.1007/s00604-018-3139-1</identifier><identifier>PMID: 30637494</identifier><language>eng</language><publisher>Vienna: Springer Vienna</publisher><subject>Analytical Chemistry ; Arrays ; Benzene ; Bismuth ; Characterization and Evaluation of Materials ; Chemistry ; Chemistry and Materials Science ; Cysteamine ; Elution ; Gold ; Microengineering ; Microfluidics ; Mopping ; Nanochemistry ; Nanoparticles ; Nanotechnology ; Original Paper ; Platinum ; Reagents ; Solid phases ; Urine</subject><ispartof>Mikrochimica acta (1966), 2019-02, Vol.186 (2), p.107-8, Article 107</ispartof><rights>Springer-Verlag GmbH Austria, part of Springer Nature 2019</rights><rights>Microchimica Acta is a copyright of Springer, (2019). All Rights Reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c372t-ba849b871bbde0135343430fe6a569aab412e5bdc5719f71975505eba6f2ea4e3</citedby><cites>FETCH-LOGICAL-c372t-ba849b871bbde0135343430fe6a569aab412e5bdc5719f71975505eba6f2ea4e3</cites><orcidid>0000-0003-2171-2202</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s00604-018-3139-1$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s00604-018-3139-1$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,27922,27923,41486,42555,51317</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30637494$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Chen, Zhenna</creatorcontrib><creatorcontrib>Chen, Beibei</creatorcontrib><creatorcontrib>He, Man</creatorcontrib><creatorcontrib>Wang, Han</creatorcontrib><creatorcontrib>Hu, Bin</creatorcontrib><title>A porous organic polymer with magnetic nanoparticles on a chip array for preconcentration of platinum(IV), gold(III) and bismuth(III) prior to their on-line quantitation by ICP-MS</title><title>Mikrochimica acta (1966)</title><addtitle>Microchim Acta</addtitle><addtitle>Mikrochim Acta</addtitle><description>A chip-based array is described for magnetic solid-phase microextraction (MSPME) of the ions of Pt, Au and Bi. Magnetic porous organic polymers (MOPs) prepared from magnetite nanoparticles and 1,3,5-tris(4-aminophenyl)benzene are introduced as a novel adsorbent. Eight solid phase extraction columns packed with MOPs were integrated in parallel on a microfluidic chip for array microextraction. After elution with a 12% (m/v) solution of cysteamine hydrochloride (pH 8.0), the eluent is introduced into an ICP-MS instrument for quantification. Under the optimized conditions, the limits of detection for Pt, Au and Bi are 8.6, 4.4 and 3.4 ng L
−1
, respectively. The sample throughput is 7 h
−1
, and the adsorption capacities are 32, 24 and 24 μg mg
−1
for Pt, Au and Bi, respectively. The method was validated by the determination of Bi in a certified reference material (GSH-1A; human hair), and the values obtained coincided with the certified value. This method was also applied to the determination of Pt, Au and Bi in (spiked) urine and cell samples, and good recoveries (85.8–113%) were achieved. The method is highly sensitive and has a high throughput and a low sample/reagent consumption (with 500 HeLa cells consumed).
Graphical abstract
Schematic presentation of the magnetic packed column, microfluidic chip, and online chip-based MSPME-ICPMS system. Design sketch of the online system: microextraction unit (blue lines), microvalves (black lines), outlet channels (yellow lines), permanent magnets (red), urine and cell samples.</description><subject>Analytical Chemistry</subject><subject>Arrays</subject><subject>Benzene</subject><subject>Bismuth</subject><subject>Characterization and Evaluation of Materials</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><subject>Cysteamine</subject><subject>Elution</subject><subject>Gold</subject><subject>Microengineering</subject><subject>Microfluidics</subject><subject>Mopping</subject><subject>Nanochemistry</subject><subject>Nanoparticles</subject><subject>Nanotechnology</subject><subject>Original Paper</subject><subject>Platinum</subject><subject>Reagents</subject><subject>Solid phases</subject><subject>Urine</subject><issn>0026-3672</issn><issn>1436-5073</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp1kV2L1DAUhoMo7rj6A7yRgDezsNWkSZPp5TL4UVhR8OO2JO3pTJY26SYpy_wu_6Bn6aogSAg5OXnOe5K8hLzk7A1nTL9NjCkmC8Z3heCiLvgjsuFSqKJiWjwmG8ZKVQilyzPyLKUbxrhWpXxKzgRTQstabsjPKzqHGJZEQzwY7zrcjqcJIr1z-Ugnc_CQMeuND7OJGI6ArKeGdkc3UxOjOdEhRDpH6ILvwOdoskMiDHQeMfTLtG1-XFzSQxj7bdM0F9T4nlqXpiUf18QcHUrkQPMRXET9YnQe6O1ifHZ51bMn2uy_FJ--PidPBjMmePGwnpPv7999238srj9_aPZX10UndJkLa3aytjvNre2BcVEJiYMNoEylamOs5CVUtu8qzesBp64qVoE1aijBSBDnZLvqzjHcLpByO7nUwTgaD_hjbcl1jao7tUP09T_oTViix9shpVRdalVLpPhKdTGkFGFo8d2TiaeWs_be0XZ1tEVH23tHW441rx6UFztB_6fit4UIlCuQ8MgfIP5t_X_VX3jdrHg</recordid><startdate>20190201</startdate><enddate>20190201</enddate><creator>Chen, Zhenna</creator><creator>Chen, Beibei</creator><creator>He, Man</creator><creator>Wang, Han</creator><creator>Hu, Bin</creator><general>Springer Vienna</general><general>Springer Nature B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>K9.</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-2171-2202</orcidid></search><sort><creationdate>20190201</creationdate><title>A porous organic polymer with magnetic nanoparticles on a chip array for preconcentration of platinum(IV), gold(III) and bismuth(III) prior to their on-line quantitation by ICP-MS</title><author>Chen, Zhenna ; Chen, Beibei ; He, Man ; Wang, Han ; Hu, Bin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c372t-ba849b871bbde0135343430fe6a569aab412e5bdc5719f71975505eba6f2ea4e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Analytical Chemistry</topic><topic>Arrays</topic><topic>Benzene</topic><topic>Bismuth</topic><topic>Characterization and Evaluation of Materials</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><topic>Cysteamine</topic><topic>Elution</topic><topic>Gold</topic><topic>Microengineering</topic><topic>Microfluidics</topic><topic>Mopping</topic><topic>Nanochemistry</topic><topic>Nanoparticles</topic><topic>Nanotechnology</topic><topic>Original Paper</topic><topic>Platinum</topic><topic>Reagents</topic><topic>Solid phases</topic><topic>Urine</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chen, Zhenna</creatorcontrib><creatorcontrib>Chen, Beibei</creatorcontrib><creatorcontrib>He, Man</creatorcontrib><creatorcontrib>Wang, Han</creatorcontrib><creatorcontrib>Hu, Bin</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>MEDLINE - Academic</collection><jtitle>Mikrochimica acta (1966)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chen, Zhenna</au><au>Chen, Beibei</au><au>He, Man</au><au>Wang, Han</au><au>Hu, Bin</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A porous organic polymer with magnetic nanoparticles on a chip array for preconcentration of platinum(IV), gold(III) and bismuth(III) prior to their on-line quantitation by ICP-MS</atitle><jtitle>Mikrochimica acta (1966)</jtitle><stitle>Microchim Acta</stitle><addtitle>Mikrochim Acta</addtitle><date>2019-02-01</date><risdate>2019</risdate><volume>186</volume><issue>2</issue><spage>107</spage><epage>8</epage><pages>107-8</pages><artnum>107</artnum><issn>0026-3672</issn><eissn>1436-5073</eissn><abstract>A chip-based array is described for magnetic solid-phase microextraction (MSPME) of the ions of Pt, Au and Bi. Magnetic porous organic polymers (MOPs) prepared from magnetite nanoparticles and 1,3,5-tris(4-aminophenyl)benzene are introduced as a novel adsorbent. Eight solid phase extraction columns packed with MOPs were integrated in parallel on a microfluidic chip for array microextraction. After elution with a 12% (m/v) solution of cysteamine hydrochloride (pH 8.0), the eluent is introduced into an ICP-MS instrument for quantification. Under the optimized conditions, the limits of detection for Pt, Au and Bi are 8.6, 4.4 and 3.4 ng L
−1
, respectively. The sample throughput is 7 h
−1
, and the adsorption capacities are 32, 24 and 24 μg mg
−1
for Pt, Au and Bi, respectively. The method was validated by the determination of Bi in a certified reference material (GSH-1A; human hair), and the values obtained coincided with the certified value. This method was also applied to the determination of Pt, Au and Bi in (spiked) urine and cell samples, and good recoveries (85.8–113%) were achieved. The method is highly sensitive and has a high throughput and a low sample/reagent consumption (with 500 HeLa cells consumed).
Graphical abstract
Schematic presentation of the magnetic packed column, microfluidic chip, and online chip-based MSPME-ICPMS system. Design sketch of the online system: microextraction unit (blue lines), microvalves (black lines), outlet channels (yellow lines), permanent magnets (red), urine and cell samples.</abstract><cop>Vienna</cop><pub>Springer Vienna</pub><pmid>30637494</pmid><doi>10.1007/s00604-018-3139-1</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0003-2171-2202</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0026-3672 |
ispartof | Mikrochimica acta (1966), 2019-02, Vol.186 (2), p.107-8, Article 107 |
issn | 0026-3672 1436-5073 |
language | eng |
recordid | cdi_proquest_miscellaneous_2179353868 |
source | SpringerLink Journals - AutoHoldings |
subjects | Analytical Chemistry Arrays Benzene Bismuth Characterization and Evaluation of Materials Chemistry Chemistry and Materials Science Cysteamine Elution Gold Microengineering Microfluidics Mopping Nanochemistry Nanoparticles Nanotechnology Original Paper Platinum Reagents Solid phases Urine |
title | A porous organic polymer with magnetic nanoparticles on a chip array for preconcentration of platinum(IV), gold(III) and bismuth(III) prior to their on-line quantitation by ICP-MS |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T20%3A00%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20porous%20organic%20polymer%20with%20magnetic%20nanoparticles%20on%20a%20chip%20array%20for%20preconcentration%20of%20platinum(IV),%20gold(III)%20and%20bismuth(III)%20prior%20to%20their%20on-line%20quantitation%20by%20ICP-MS&rft.jtitle=Mikrochimica%20acta%20(1966)&rft.au=Chen,%20Zhenna&rft.date=2019-02-01&rft.volume=186&rft.issue=2&rft.spage=107&rft.epage=8&rft.pages=107-8&rft.artnum=107&rft.issn=0026-3672&rft.eissn=1436-5073&rft_id=info:doi/10.1007/s00604-018-3139-1&rft_dat=%3Cproquest_cross%3E2166927694%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2166927694&rft_id=info:pmid/30637494&rfr_iscdi=true |