The Role of Angle in the Evaluation of Ablation Accuracy in Pulmonary Vein Isolation Navigated by Image Integration

The conventional index for ablation accuracy is to compare the distance between mapping points with and without treatment by using image integration. We attempted to quantitatively evaluate the role of angle as an index in the ablation accuracy in patients with atrial fibrillation (AF). A total of 4...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Heart surgery forum 2018-11, Vol.21 (6), p.E438-E442
Hauptverfasser: Chen, Song-Wen, Cai, Li-Dong, Asakawa, Tetsuya, Zhou, Gen-Qing, Wei, Yong, Qi, Bao-Zhen, Ling, Zhi-Yu, Wu, Hai-Qing, Xu, Juan, Liu, Shao-Wen
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page E442
container_issue 6
container_start_page E438
container_title The Heart surgery forum
container_volume 21
creator Chen, Song-Wen
Cai, Li-Dong
Asakawa, Tetsuya
Zhou, Gen-Qing
Wei, Yong
Qi, Bao-Zhen
Ling, Zhi-Yu
Wu, Hai-Qing
Xu, Juan
Liu, Shao-Wen
description The conventional index for ablation accuracy is to compare the distance between mapping points with and without treatment by using image integration. We attempted to quantitatively evaluate the role of angle as an index in the ablation accuracy in patients with atrial fibrillation (AF). A total of 48 patients with AF were included in the present study. Virtual fluoroscopy planes were predicted by pulmonary vein (PV) angiography, and the standard image planes were defined on the basis of the computed tomography images. Ablations were performed, guided by image integration; and the ablation planes were defined by the actual ablation rings. The predicted angle (distance) was defined as the angle (distance) between the fluoroscopy (predicted) plane and image (standard) plane, whereas the actual angle (distance) was defined as the angle (distance) between the ablation (actual) planes and the image (standard) planes. We found that all actual angles were significantly smaller than the predicted angles (P .05). Our finding indicates that both the angle and the distance can be significantly reduced by navigation with image integration, but that the angle exhibited better sensitivity than the conventional index of distance. We suggest that the angle should be considered as a new index for ablation accuracy.
doi_str_mv 10.1532/hsf.2231
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2163011829</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2163011829</sourcerecordid><originalsourceid>FETCH-LOGICAL-c310t-781efc0c76a4b1f15618cc55c9349cd33e0f4ad65e673d0276f384dc1fc4ed6d3</originalsourceid><addsrcrecordid>eNpFkN1LwzAUxYMobk7Bv0Dy6EtnbtKk7eMYUwtDRaavJc1HV2mb2bSD_fd2H-rTPfeeHwfuQegWyBQ4ow9rb6eUMjhDY-CUBkIIej5oksQB4wAjdOX9FyFUUCou0YgRQUIh-Bj51drgd1cZ7CyeNcUgygZ3w3GxlVUvu9I1ByuvjnqmVN9Ktdtjb31Vu0a2O_xphjX17gS9yG1ZyM5onO9wWsvC4LTpTNEe7Gt0YWXlzc1pTtDH42I1fw6Wr0_pfLYMFAPSBVEMxiqiIiHDHCxwAbFSnKuEhYnSjBliQ6kFNyJimtBIWBaHWoFVodFCswm6P-ZuWvfdG99ldemVqSrZGNf7jIJgBCCmyT-qWud9a2y2act6-CwDku0rzoaKs33FA3p3Su3z2ug_8LdT9gMKl3cW</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2163011829</pqid></control><display><type>article</type><title>The Role of Angle in the Evaluation of Ablation Accuracy in Pulmonary Vein Isolation Navigated by Image Integration</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Chen, Song-Wen ; Cai, Li-Dong ; Asakawa, Tetsuya ; Zhou, Gen-Qing ; Wei, Yong ; Qi, Bao-Zhen ; Ling, Zhi-Yu ; Wu, Hai-Qing ; Xu, Juan ; Liu, Shao-Wen</creator><creatorcontrib>Chen, Song-Wen ; Cai, Li-Dong ; Asakawa, Tetsuya ; Zhou, Gen-Qing ; Wei, Yong ; Qi, Bao-Zhen ; Ling, Zhi-Yu ; Wu, Hai-Qing ; Xu, Juan ; Liu, Shao-Wen</creatorcontrib><description>The conventional index for ablation accuracy is to compare the distance between mapping points with and without treatment by using image integration. We attempted to quantitatively evaluate the role of angle as an index in the ablation accuracy in patients with atrial fibrillation (AF). A total of 48 patients with AF were included in the present study. Virtual fluoroscopy planes were predicted by pulmonary vein (PV) angiography, and the standard image planes were defined on the basis of the computed tomography images. Ablations were performed, guided by image integration; and the ablation planes were defined by the actual ablation rings. The predicted angle (distance) was defined as the angle (distance) between the fluoroscopy (predicted) plane and image (standard) plane, whereas the actual angle (distance) was defined as the angle (distance) between the ablation (actual) planes and the image (standard) planes. We found that all actual angles were significantly smaller than the predicted angles (P &lt;.05), but only the actual distances in the left PV, right inferior PV, right superior PV, and right PV were significantly smaller; the distances in the left inferior PV and left superior PV were not significantly different (P &gt;.05). Our finding indicates that both the angle and the distance can be significantly reduced by navigation with image integration, but that the angle exhibited better sensitivity than the conventional index of distance. We suggest that the angle should be considered as a new index for ablation accuracy.</description><identifier>ISSN: 1098-3511</identifier><identifier>EISSN: 1522-6662</identifier><identifier>DOI: 10.1532/hsf.2231</identifier><identifier>PMID: 30604665</identifier><language>eng</language><publisher>United States</publisher><ispartof>The Heart surgery forum, 2018-11, Vol.21 (6), p.E438-E442</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30604665$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Chen, Song-Wen</creatorcontrib><creatorcontrib>Cai, Li-Dong</creatorcontrib><creatorcontrib>Asakawa, Tetsuya</creatorcontrib><creatorcontrib>Zhou, Gen-Qing</creatorcontrib><creatorcontrib>Wei, Yong</creatorcontrib><creatorcontrib>Qi, Bao-Zhen</creatorcontrib><creatorcontrib>Ling, Zhi-Yu</creatorcontrib><creatorcontrib>Wu, Hai-Qing</creatorcontrib><creatorcontrib>Xu, Juan</creatorcontrib><creatorcontrib>Liu, Shao-Wen</creatorcontrib><title>The Role of Angle in the Evaluation of Ablation Accuracy in Pulmonary Vein Isolation Navigated by Image Integration</title><title>The Heart surgery forum</title><addtitle>Heart Surg Forum</addtitle><description>The conventional index for ablation accuracy is to compare the distance between mapping points with and without treatment by using image integration. We attempted to quantitatively evaluate the role of angle as an index in the ablation accuracy in patients with atrial fibrillation (AF). A total of 48 patients with AF were included in the present study. Virtual fluoroscopy planes were predicted by pulmonary vein (PV) angiography, and the standard image planes were defined on the basis of the computed tomography images. Ablations were performed, guided by image integration; and the ablation planes were defined by the actual ablation rings. The predicted angle (distance) was defined as the angle (distance) between the fluoroscopy (predicted) plane and image (standard) plane, whereas the actual angle (distance) was defined as the angle (distance) between the ablation (actual) planes and the image (standard) planes. We found that all actual angles were significantly smaller than the predicted angles (P &lt;.05), but only the actual distances in the left PV, right inferior PV, right superior PV, and right PV were significantly smaller; the distances in the left inferior PV and left superior PV were not significantly different (P &gt;.05). Our finding indicates that both the angle and the distance can be significantly reduced by navigation with image integration, but that the angle exhibited better sensitivity than the conventional index of distance. We suggest that the angle should be considered as a new index for ablation accuracy.</description><issn>1098-3511</issn><issn>1522-6662</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNpFkN1LwzAUxYMobk7Bv0Dy6EtnbtKk7eMYUwtDRaavJc1HV2mb2bSD_fd2H-rTPfeeHwfuQegWyBQ4ow9rb6eUMjhDY-CUBkIIej5oksQB4wAjdOX9FyFUUCou0YgRQUIh-Bj51drgd1cZ7CyeNcUgygZ3w3GxlVUvu9I1ByuvjnqmVN9Ktdtjb31Vu0a2O_xphjX17gS9yG1ZyM5onO9wWsvC4LTpTNEe7Gt0YWXlzc1pTtDH42I1fw6Wr0_pfLYMFAPSBVEMxiqiIiHDHCxwAbFSnKuEhYnSjBliQ6kFNyJimtBIWBaHWoFVodFCswm6P-ZuWvfdG99ldemVqSrZGNf7jIJgBCCmyT-qWud9a2y2act6-CwDku0rzoaKs33FA3p3Su3z2ug_8LdT9gMKl3cW</recordid><startdate>20181106</startdate><enddate>20181106</enddate><creator>Chen, Song-Wen</creator><creator>Cai, Li-Dong</creator><creator>Asakawa, Tetsuya</creator><creator>Zhou, Gen-Qing</creator><creator>Wei, Yong</creator><creator>Qi, Bao-Zhen</creator><creator>Ling, Zhi-Yu</creator><creator>Wu, Hai-Qing</creator><creator>Xu, Juan</creator><creator>Liu, Shao-Wen</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20181106</creationdate><title>The Role of Angle in the Evaluation of Ablation Accuracy in Pulmonary Vein Isolation Navigated by Image Integration</title><author>Chen, Song-Wen ; Cai, Li-Dong ; Asakawa, Tetsuya ; Zhou, Gen-Qing ; Wei, Yong ; Qi, Bao-Zhen ; Ling, Zhi-Yu ; Wu, Hai-Qing ; Xu, Juan ; Liu, Shao-Wen</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c310t-781efc0c76a4b1f15618cc55c9349cd33e0f4ad65e673d0276f384dc1fc4ed6d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chen, Song-Wen</creatorcontrib><creatorcontrib>Cai, Li-Dong</creatorcontrib><creatorcontrib>Asakawa, Tetsuya</creatorcontrib><creatorcontrib>Zhou, Gen-Qing</creatorcontrib><creatorcontrib>Wei, Yong</creatorcontrib><creatorcontrib>Qi, Bao-Zhen</creatorcontrib><creatorcontrib>Ling, Zhi-Yu</creatorcontrib><creatorcontrib>Wu, Hai-Qing</creatorcontrib><creatorcontrib>Xu, Juan</creatorcontrib><creatorcontrib>Liu, Shao-Wen</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Heart surgery forum</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chen, Song-Wen</au><au>Cai, Li-Dong</au><au>Asakawa, Tetsuya</au><au>Zhou, Gen-Qing</au><au>Wei, Yong</au><au>Qi, Bao-Zhen</au><au>Ling, Zhi-Yu</au><au>Wu, Hai-Qing</au><au>Xu, Juan</au><au>Liu, Shao-Wen</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The Role of Angle in the Evaluation of Ablation Accuracy in Pulmonary Vein Isolation Navigated by Image Integration</atitle><jtitle>The Heart surgery forum</jtitle><addtitle>Heart Surg Forum</addtitle><date>2018-11-06</date><risdate>2018</risdate><volume>21</volume><issue>6</issue><spage>E438</spage><epage>E442</epage><pages>E438-E442</pages><issn>1098-3511</issn><eissn>1522-6662</eissn><abstract>The conventional index for ablation accuracy is to compare the distance between mapping points with and without treatment by using image integration. We attempted to quantitatively evaluate the role of angle as an index in the ablation accuracy in patients with atrial fibrillation (AF). A total of 48 patients with AF were included in the present study. Virtual fluoroscopy planes were predicted by pulmonary vein (PV) angiography, and the standard image planes were defined on the basis of the computed tomography images. Ablations were performed, guided by image integration; and the ablation planes were defined by the actual ablation rings. The predicted angle (distance) was defined as the angle (distance) between the fluoroscopy (predicted) plane and image (standard) plane, whereas the actual angle (distance) was defined as the angle (distance) between the ablation (actual) planes and the image (standard) planes. We found that all actual angles were significantly smaller than the predicted angles (P &lt;.05), but only the actual distances in the left PV, right inferior PV, right superior PV, and right PV were significantly smaller; the distances in the left inferior PV and left superior PV were not significantly different (P &gt;.05). Our finding indicates that both the angle and the distance can be significantly reduced by navigation with image integration, but that the angle exhibited better sensitivity than the conventional index of distance. We suggest that the angle should be considered as a new index for ablation accuracy.</abstract><cop>United States</cop><pmid>30604665</pmid><doi>10.1532/hsf.2231</doi></addata></record>
fulltext fulltext
identifier ISSN: 1098-3511
ispartof The Heart surgery forum, 2018-11, Vol.21 (6), p.E438-E442
issn 1098-3511
1522-6662
language eng
recordid cdi_proquest_miscellaneous_2163011829
source Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
title The Role of Angle in the Evaluation of Ablation Accuracy in Pulmonary Vein Isolation Navigated by Image Integration
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T10%3A28%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20Role%20of%20Angle%20in%20the%20Evaluation%20of%20Ablation%20Accuracy%20in%20Pulmonary%20Vein%20Isolation%20Navigated%20by%20Image%20Integration&rft.jtitle=The%20Heart%20surgery%20forum&rft.au=Chen,%20Song-Wen&rft.date=2018-11-06&rft.volume=21&rft.issue=6&rft.spage=E438&rft.epage=E442&rft.pages=E438-E442&rft.issn=1098-3511&rft.eissn=1522-6662&rft_id=info:doi/10.1532/hsf.2231&rft_dat=%3Cproquest_cross%3E2163011829%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2163011829&rft_id=info:pmid/30604665&rfr_iscdi=true