RP-hPLC/ESI MS determination of acyl chain positions in phospholipids

Since phospholipids are used as excipients in many pharmaceutical products, there is a need for validated strategies to characterize the phospholipid constituents. We describe a reversed phase HPLC/electrospray ionization mass spectrometry method that is an alternative to the laborious phospholipase...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of separation science 2002-04, Vol.25 (5-6), p.285-289
Hauptverfasser: Vernooij, Elisabeth A. A. M., Brouwers, Jos F. H. M., Kettenes-Van den Bosch, J. Jantina, Crommelin, Daan J. A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 289
container_issue 5-6
container_start_page 285
container_title Journal of separation science
container_volume 25
creator Vernooij, Elisabeth A. A. M.
Brouwers, Jos F. H. M.
Kettenes-Van den Bosch, J. Jantina
Crommelin, Daan J. A.
description Since phospholipids are used as excipients in many pharmaceutical products, there is a need for validated strategies to characterize the phospholipid constituents. We describe a reversed phase HPLC/electrospray ionization mass spectrometry method that is an alternative to the laborious phospholipase A2 treatment commonly used to determine the acyl chain positions in phospholipids. This reversed phase HPLC/electrospray mass spectrometry system (a) shows good chromatographic resolution for phosphatidylcholine molecular species, (b) allows determination of the composition of complex mixtures of phosphatidylcholines, and, most important, (c) allows unequivocal assignment of the positions of the acyl chains on the glycerol backbone in mixtures of POPC and OPPC and in mixtures of POPE and OPPE.
doi_str_mv 10.1002/1615-9314(20020401)25:5/6<285::AID-JSSC285>3.0.CO;2-U
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_21479959</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>610294</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4785-cc4f53c344ee676d1c4bc73648c34a8aa0487fc25a9884e1bdf9b5be55715633</originalsourceid><addsrcrecordid>eNqVkF1P2zAYhSM0JFjhP-SGabtI628n3YZUZaXrKBSRVmxXr1zXUT3SpIuLoP8eR_3gZjdcWPY5Oj7vqycIvmPUxgiRDhaYRwnF7DPxEjGEvxDe5R3xjcS82-0Nf0S_siz14pK2UTsdfyXR9Cg4Pfz7cHgjcRJ8dO4vQljGCToN-vd30eJulHb62TC8ycK5WZt6aUu1tlUZVnmo9KYI9ULZMlxVzja2CxuxqJw_hV3ZuTsLjnNVOHO-u1vB5Ko_SX9Go_FgmPZGkWYy5pHWLOdUU8aMEVLMsWYzLalgsfdUrBRiscw14SqJY2bwbJ4nMz4znEvMBaWt4NO2dlVX_56MW8PSOm2KQpWmenJAMJNJwhMfnG6Duq6cq00Oq9ouVb0BjKBhCg0PaNjAnikQDhwEeIwAninsmAIFBOkYCEx978VuAeW0KvJaldq6t3IqcMJQs-ifbe7ZFmbzzuH_n723fHe07bZubV4O3ap-BCGp5PBwO4AHMroeMJnBb_oK0TOkTw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>21479959</pqid></control><display><type>article</type><title>RP-hPLC/ESI MS determination of acyl chain positions in phospholipids</title><source>Wiley Online Library Journals Frontfile Complete</source><creator>Vernooij, Elisabeth A. A. M. ; Brouwers, Jos F. H. M. ; Kettenes-Van den Bosch, J. Jantina ; Crommelin, Daan J. A.</creator><creatorcontrib>Vernooij, Elisabeth A. A. M. ; Brouwers, Jos F. H. M. ; Kettenes-Van den Bosch, J. Jantina ; Crommelin, Daan J. A.</creatorcontrib><description>Since phospholipids are used as excipients in many pharmaceutical products, there is a need for validated strategies to characterize the phospholipid constituents. We describe a reversed phase HPLC/electrospray ionization mass spectrometry method that is an alternative to the laborious phospholipase A2 treatment commonly used to determine the acyl chain positions in phospholipids. This reversed phase HPLC/electrospray mass spectrometry system (a) shows good chromatographic resolution for phosphatidylcholine molecular species, (b) allows determination of the composition of complex mixtures of phosphatidylcholines, and, most important, (c) allows unequivocal assignment of the positions of the acyl chains on the glycerol backbone in mixtures of POPC and OPPC and in mixtures of POPE and OPPE.</description><identifier>ISSN: 1615-9306</identifier><identifier>EISSN: 1615-9314</identifier><identifier>DOI: 10.1002/1615-9314(20020401)25:5/6&lt;285::AID-JSSC285&gt;3.0.CO;2-U</identifier><language>eng</language><publisher>Weinheim: WILEY-VCH Verlag</publisher><subject>Analysis ; Analytical chemistry ; Biological and medical sciences ; Chemistry ; Chromatographic analysis ; Chromatographic methods and physical methods associated with chromatography ; Drug products ; Electrospray ionization ; Exact sciences and technology ; General pharmacology ; Glycerol ; HPLC ; Ionization ; Mass spectrometry ; Medical sciences ; Other chromatographic methods ; Pharmacology. Drug treatments ; Phospholipids</subject><ispartof>Journal of separation science, 2002-04, Vol.25 (5-6), p.285-289</ispartof><rights>Copyright © 2002 WILEY‐VCH Verlag GmbH, Weinheim, Fed. Rep. of Germany</rights><rights>2002 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c4785-cc4f53c344ee676d1c4bc73648c34a8aa0487fc25a9884e1bdf9b5be55715633</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2F1615-9314%2820020401%2925%3A5%2F6%3C285%3A%3AAID-JSSC285%3E3.0.CO%3B2-U$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2F1615-9314%2820020401%2925%3A5%2F6%3C285%3A%3AAID-JSSC285%3E3.0.CO%3B2-U$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27901,27902,45550,45551</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=13619403$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Vernooij, Elisabeth A. A. M.</creatorcontrib><creatorcontrib>Brouwers, Jos F. H. M.</creatorcontrib><creatorcontrib>Kettenes-Van den Bosch, J. Jantina</creatorcontrib><creatorcontrib>Crommelin, Daan J. A.</creatorcontrib><title>RP-hPLC/ESI MS determination of acyl chain positions in phospholipids</title><title>Journal of separation science</title><addtitle>J. Sep. Science</addtitle><description>Since phospholipids are used as excipients in many pharmaceutical products, there is a need for validated strategies to characterize the phospholipid constituents. We describe a reversed phase HPLC/electrospray ionization mass spectrometry method that is an alternative to the laborious phospholipase A2 treatment commonly used to determine the acyl chain positions in phospholipids. This reversed phase HPLC/electrospray mass spectrometry system (a) shows good chromatographic resolution for phosphatidylcholine molecular species, (b) allows determination of the composition of complex mixtures of phosphatidylcholines, and, most important, (c) allows unequivocal assignment of the positions of the acyl chains on the glycerol backbone in mixtures of POPC and OPPC and in mixtures of POPE and OPPE.</description><subject>Analysis</subject><subject>Analytical chemistry</subject><subject>Biological and medical sciences</subject><subject>Chemistry</subject><subject>Chromatographic analysis</subject><subject>Chromatographic methods and physical methods associated with chromatography</subject><subject>Drug products</subject><subject>Electrospray ionization</subject><subject>Exact sciences and technology</subject><subject>General pharmacology</subject><subject>Glycerol</subject><subject>HPLC</subject><subject>Ionization</subject><subject>Mass spectrometry</subject><subject>Medical sciences</subject><subject>Other chromatographic methods</subject><subject>Pharmacology. Drug treatments</subject><subject>Phospholipids</subject><issn>1615-9306</issn><issn>1615-9314</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><recordid>eNqVkF1P2zAYhSM0JFjhP-SGabtI628n3YZUZaXrKBSRVmxXr1zXUT3SpIuLoP8eR_3gZjdcWPY5Oj7vqycIvmPUxgiRDhaYRwnF7DPxEjGEvxDe5R3xjcS82-0Nf0S_siz14pK2UTsdfyXR9Cg4Pfz7cHgjcRJ8dO4vQljGCToN-vd30eJulHb62TC8ycK5WZt6aUu1tlUZVnmo9KYI9ULZMlxVzja2CxuxqJw_hV3ZuTsLjnNVOHO-u1vB5Ko_SX9Go_FgmPZGkWYy5pHWLOdUU8aMEVLMsWYzLalgsfdUrBRiscw14SqJY2bwbJ4nMz4znEvMBaWt4NO2dlVX_56MW8PSOm2KQpWmenJAMJNJwhMfnG6Duq6cq00Oq9ouVb0BjKBhCg0PaNjAnikQDhwEeIwAninsmAIFBOkYCEx978VuAeW0KvJaldq6t3IqcMJQs-ifbe7ZFmbzzuH_n723fHe07bZubV4O3ap-BCGp5PBwO4AHMroeMJnBb_oK0TOkTw</recordid><startdate>200204</startdate><enddate>200204</enddate><creator>Vernooij, Elisabeth A. A. M.</creator><creator>Brouwers, Jos F. H. M.</creator><creator>Kettenes-Van den Bosch, J. Jantina</creator><creator>Crommelin, Daan J. A.</creator><general>WILEY-VCH Verlag</general><general>WILEY‐VCH Verlag</general><general>Wiley</general><scope>BSCLL</scope><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>200204</creationdate><title>RP-hPLC/ESI MS determination of acyl chain positions in phospholipids</title><author>Vernooij, Elisabeth A. A. M. ; Brouwers, Jos F. H. M. ; Kettenes-Van den Bosch, J. Jantina ; Crommelin, Daan J. A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4785-cc4f53c344ee676d1c4bc73648c34a8aa0487fc25a9884e1bdf9b5be55715633</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Analysis</topic><topic>Analytical chemistry</topic><topic>Biological and medical sciences</topic><topic>Chemistry</topic><topic>Chromatographic analysis</topic><topic>Chromatographic methods and physical methods associated with chromatography</topic><topic>Drug products</topic><topic>Electrospray ionization</topic><topic>Exact sciences and technology</topic><topic>General pharmacology</topic><topic>Glycerol</topic><topic>HPLC</topic><topic>Ionization</topic><topic>Mass spectrometry</topic><topic>Medical sciences</topic><topic>Other chromatographic methods</topic><topic>Pharmacology. Drug treatments</topic><topic>Phospholipids</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Vernooij, Elisabeth A. A. M.</creatorcontrib><creatorcontrib>Brouwers, Jos F. H. M.</creatorcontrib><creatorcontrib>Kettenes-Van den Bosch, J. Jantina</creatorcontrib><creatorcontrib>Crommelin, Daan J. A.</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>CrossRef</collection><jtitle>Journal of separation science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Vernooij, Elisabeth A. A. M.</au><au>Brouwers, Jos F. H. M.</au><au>Kettenes-Van den Bosch, J. Jantina</au><au>Crommelin, Daan J. A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>RP-hPLC/ESI MS determination of acyl chain positions in phospholipids</atitle><jtitle>Journal of separation science</jtitle><addtitle>J. Sep. Science</addtitle><date>2002-04</date><risdate>2002</risdate><volume>25</volume><issue>5-6</issue><spage>285</spage><epage>289</epage><pages>285-289</pages><issn>1615-9306</issn><eissn>1615-9314</eissn><abstract>Since phospholipids are used as excipients in many pharmaceutical products, there is a need for validated strategies to characterize the phospholipid constituents. We describe a reversed phase HPLC/electrospray ionization mass spectrometry method that is an alternative to the laborious phospholipase A2 treatment commonly used to determine the acyl chain positions in phospholipids. This reversed phase HPLC/electrospray mass spectrometry system (a) shows good chromatographic resolution for phosphatidylcholine molecular species, (b) allows determination of the composition of complex mixtures of phosphatidylcholines, and, most important, (c) allows unequivocal assignment of the positions of the acyl chains on the glycerol backbone in mixtures of POPC and OPPC and in mixtures of POPE and OPPE.</abstract><cop>Weinheim</cop><pub>WILEY-VCH Verlag</pub><doi>10.1002/1615-9314(20020401)25:5/6&lt;285::AID-JSSC285&gt;3.0.CO;2-U</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1615-9306
ispartof Journal of separation science, 2002-04, Vol.25 (5-6), p.285-289
issn 1615-9306
1615-9314
language eng
recordid cdi_proquest_miscellaneous_21479959
source Wiley Online Library Journals Frontfile Complete
subjects Analysis
Analytical chemistry
Biological and medical sciences
Chemistry
Chromatographic analysis
Chromatographic methods and physical methods associated with chromatography
Drug products
Electrospray ionization
Exact sciences and technology
General pharmacology
Glycerol
HPLC
Ionization
Mass spectrometry
Medical sciences
Other chromatographic methods
Pharmacology. Drug treatments
Phospholipids
title RP-hPLC/ESI MS determination of acyl chain positions in phospholipids
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-20T03%3A39%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=RP-hPLC/ESI%20MS%20determination%20of%20acyl%20chain%20positions%20in%20phospholipids&rft.jtitle=Journal%20of%20separation%20science&rft.au=Vernooij,%20Elisabeth%20A.%20A.%20M.&rft.date=2002-04&rft.volume=25&rft.issue=5-6&rft.spage=285&rft.epage=289&rft.pages=285-289&rft.issn=1615-9306&rft.eissn=1615-9314&rft_id=info:doi/10.1002/1615-9314(20020401)25:5/6%3C285::AID-JSSC285%3E3.0.CO;2-U&rft_dat=%3Cproquest_cross%3E610294%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=21479959&rft_id=info:pmid/&rfr_iscdi=true