The peptide-tethered lipid membrane as a biomimetic system to incorporate cytochrome c oxidase in a functionally active form

Peptide-supported lipid bilayers are investigated as a new class of solidsupported membranes tethered to the support by a peptide spacer. They are referred to as peptide tethered lipid membranes (tBLMs), formed by the fusion of liposomes with a thiopeptide-lipid monolayer chemisorbed on a gold suppo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biosensors & bioelectronics 1999-10, Vol.14 (7), p.651-662
Hauptverfasser: Naumann, R., Schmidt, E.K., Jonczyk, A., Fendler, K., Kadenbach, B., Liebermann, T., Offenhäusser, A., Knoll, W.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 662
container_issue 7
container_start_page 651
container_title Biosensors & bioelectronics
container_volume 14
creator Naumann, R.
Schmidt, E.K.
Jonczyk, A.
Fendler, K.
Kadenbach, B.
Liebermann, T.
Offenhäusser, A.
Knoll, W.
description Peptide-supported lipid bilayers are investigated as a new class of solidsupported membranes tethered to the support by a peptide spacer. They are referred to as peptide tethered lipid membranes (tBLMs), formed by the fusion of liposomes with a thiopeptide-lipid monolayer chemisorbed on a gold support. Peptide tBLMs are designed as a biomimetic system to investigate integral membrane proteins. As an example, cytochrome c oxidase (COX) from bovine heart is incorporated into the preformed peptide tBLM by dilution of the solubilised protein below the critical micellar concentration. The formation of the lipid film as well as the incorporation of the protein were monitored by surface plasmon resonance spectroscopy and surface plasmon fluorescence spectroscopy. COX is activated by adding the reduced form of cytochrome c to the air-saturated buffer solution. Using electrochemical techniques, such as square wave voltammetry (SWV) and chronoamperometry (CA), the direct electron transfer between COX and the gold electrode is observed as well as proton transport from the inside to the outside across the lipid bilayer. Proton transport is then further investigated using impedance spectroscopy, although the electrode is shown to be only partially (70%) covered with a bilayer while defect domains with only a monolayer of peptide or peptide-lipid coexist (approx. 30%). Proton transport carried out by the COX is shown to be voltage dependent. This transport is indicated as a resistance in parallel to the resistance of the lipid film. As a consequence, the total resistance decreases as a function of the concentration of cytochrome c and increases again either by removal of the substrate or by addition of cyanide as an inhibitor of COX. The conductance in the presence of the activated enzyme correlates with the known turnover rate of COX. These experiments demonstrate the possibility to assess the activity of integral membrane proteins incorporated in peptide tBLMs using electrochemical techniques. The system could thus be promising for screening as well as biosensor applications.
doi_str_mv 10.1016/S0956-5663(99)00036-6
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_21428810</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0956566399000366</els_id><sourcerecordid>435903</sourcerecordid><originalsourceid>FETCH-LOGICAL-c367t-2f201033c4ba6d1d32112311ade6087cb20b5e42bcf3d1f7c203e8db05a6123c3</originalsourceid><addsrcrecordid>eNqFkE1r3DAQhkVJoZttf0JBh1KSg1N9rGX7FEJI2sBCD9mehTwasyqW5UrakIX8-GqzITnmNHN43nmZh5CvnF1wxtWPe9bVqqqVkmddd84Yk6pSH8iCt42sVkLWJ2Txinwipyn9LVDDO7YgT5st0hnn7CxWGfMWI1o6utlZ6tH30UxITaKG9i545zE7oGmfMnqaA3UThDiHaDJS2OcA2xh8WWl4dNYkLECJDrsJsguTGcc9NWV9QDqE6D-Tj4MZE355mUvy5_Zmc_2rWv_-eXd9ta5AqiZXYhCMMylh1RtluZWCcyE5NxYVaxvoBetrXIkeBmn50IBgElvbs9qoAoJcku_Hu3MM_3aYsvYuAY5jeS7skhZ8Jdq2VCxJfQQhhpQiDnqOzpu415zpg2v97FofROqu08-utSq5by8FJoEZh2INXHoL86ZVNS_Y5RHD8uyDw6gTOJwArYsIWdvg3in6D6fblRQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>21428810</pqid></control><display><type>article</type><title>The peptide-tethered lipid membrane as a biomimetic system to incorporate cytochrome c oxidase in a functionally active form</title><source>Access via ScienceDirect (Elsevier)</source><creator>Naumann, R. ; Schmidt, E.K. ; Jonczyk, A. ; Fendler, K. ; Kadenbach, B. ; Liebermann, T. ; Offenhäusser, A. ; Knoll, W.</creator><creatorcontrib>Naumann, R. ; Schmidt, E.K. ; Jonczyk, A. ; Fendler, K. ; Kadenbach, B. ; Liebermann, T. ; Offenhäusser, A. ; Knoll, W.</creatorcontrib><description>Peptide-supported lipid bilayers are investigated as a new class of solidsupported membranes tethered to the support by a peptide spacer. They are referred to as peptide tethered lipid membranes (tBLMs), formed by the fusion of liposomes with a thiopeptide-lipid monolayer chemisorbed on a gold support. Peptide tBLMs are designed as a biomimetic system to investigate integral membrane proteins. As an example, cytochrome c oxidase (COX) from bovine heart is incorporated into the preformed peptide tBLM by dilution of the solubilised protein below the critical micellar concentration. The formation of the lipid film as well as the incorporation of the protein were monitored by surface plasmon resonance spectroscopy and surface plasmon fluorescence spectroscopy. COX is activated by adding the reduced form of cytochrome c to the air-saturated buffer solution. Using electrochemical techniques, such as square wave voltammetry (SWV) and chronoamperometry (CA), the direct electron transfer between COX and the gold electrode is observed as well as proton transport from the inside to the outside across the lipid bilayer. Proton transport is then further investigated using impedance spectroscopy, although the electrode is shown to be only partially (70%) covered with a bilayer while defect domains with only a monolayer of peptide or peptide-lipid coexist (approx. 30%). Proton transport carried out by the COX is shown to be voltage dependent. This transport is indicated as a resistance in parallel to the resistance of the lipid film. As a consequence, the total resistance decreases as a function of the concentration of cytochrome c and increases again either by removal of the substrate or by addition of cyanide as an inhibitor of COX. The conductance in the presence of the activated enzyme correlates with the known turnover rate of COX. These experiments demonstrate the possibility to assess the activity of integral membrane proteins incorporated in peptide tBLMs using electrochemical techniques. The system could thus be promising for screening as well as biosensor applications.</description><identifier>ISSN: 0956-5663</identifier><identifier>EISSN: 1873-4235</identifier><identifier>DOI: 10.1016/S0956-5663(99)00036-6</identifier><language>eng</language><publisher>Lausanne: Elsevier B.V</publisher><subject>Active ion transport ; Antibody binding assay ; Artificial membranes and reconstituted systems ; Bioassay ; Biological and medical sciences ; Biological membranes ; Biomimetic system ; Chemisorption ; Cytochrome c oxidase ; Emission spectroscopy ; Enzymes ; Fluorescence ; Fundamental and applied biological sciences. Psychology ; Impedance spectroscopy ; Lipids ; Membrane physicochemistry ; Micelles ; Molecular biophysics ; Monolayers ; Potentiometric sensors ; Solid-supported lipid film ; Surface plasmon fluorescence spectroscopy ; Surface plasmon resonance spectroscopy ; Tethered lipid film</subject><ispartof>Biosensors &amp; bioelectronics, 1999-10, Vol.14 (7), p.651-662</ispartof><rights>1999 Elsevier Science S.A.</rights><rights>2000 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c367t-2f201033c4ba6d1d32112311ade6087cb20b5e42bcf3d1f7c203e8db05a6123c3</citedby><cites>FETCH-LOGICAL-c367t-2f201033c4ba6d1d32112311ade6087cb20b5e42bcf3d1f7c203e8db05a6123c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0956-5663(99)00036-6$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=1178651$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Naumann, R.</creatorcontrib><creatorcontrib>Schmidt, E.K.</creatorcontrib><creatorcontrib>Jonczyk, A.</creatorcontrib><creatorcontrib>Fendler, K.</creatorcontrib><creatorcontrib>Kadenbach, B.</creatorcontrib><creatorcontrib>Liebermann, T.</creatorcontrib><creatorcontrib>Offenhäusser, A.</creatorcontrib><creatorcontrib>Knoll, W.</creatorcontrib><title>The peptide-tethered lipid membrane as a biomimetic system to incorporate cytochrome c oxidase in a functionally active form</title><title>Biosensors &amp; bioelectronics</title><description>Peptide-supported lipid bilayers are investigated as a new class of solidsupported membranes tethered to the support by a peptide spacer. They are referred to as peptide tethered lipid membranes (tBLMs), formed by the fusion of liposomes with a thiopeptide-lipid monolayer chemisorbed on a gold support. Peptide tBLMs are designed as a biomimetic system to investigate integral membrane proteins. As an example, cytochrome c oxidase (COX) from bovine heart is incorporated into the preformed peptide tBLM by dilution of the solubilised protein below the critical micellar concentration. The formation of the lipid film as well as the incorporation of the protein were monitored by surface plasmon resonance spectroscopy and surface plasmon fluorescence spectroscopy. COX is activated by adding the reduced form of cytochrome c to the air-saturated buffer solution. Using electrochemical techniques, such as square wave voltammetry (SWV) and chronoamperometry (CA), the direct electron transfer between COX and the gold electrode is observed as well as proton transport from the inside to the outside across the lipid bilayer. Proton transport is then further investigated using impedance spectroscopy, although the electrode is shown to be only partially (70%) covered with a bilayer while defect domains with only a monolayer of peptide or peptide-lipid coexist (approx. 30%). Proton transport carried out by the COX is shown to be voltage dependent. This transport is indicated as a resistance in parallel to the resistance of the lipid film. As a consequence, the total resistance decreases as a function of the concentration of cytochrome c and increases again either by removal of the substrate or by addition of cyanide as an inhibitor of COX. The conductance in the presence of the activated enzyme correlates with the known turnover rate of COX. These experiments demonstrate the possibility to assess the activity of integral membrane proteins incorporated in peptide tBLMs using electrochemical techniques. The system could thus be promising for screening as well as biosensor applications.</description><subject>Active ion transport</subject><subject>Antibody binding assay</subject><subject>Artificial membranes and reconstituted systems</subject><subject>Bioassay</subject><subject>Biological and medical sciences</subject><subject>Biological membranes</subject><subject>Biomimetic system</subject><subject>Chemisorption</subject><subject>Cytochrome c oxidase</subject><subject>Emission spectroscopy</subject><subject>Enzymes</subject><subject>Fluorescence</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>Impedance spectroscopy</subject><subject>Lipids</subject><subject>Membrane physicochemistry</subject><subject>Micelles</subject><subject>Molecular biophysics</subject><subject>Monolayers</subject><subject>Potentiometric sensors</subject><subject>Solid-supported lipid film</subject><subject>Surface plasmon fluorescence spectroscopy</subject><subject>Surface plasmon resonance spectroscopy</subject><subject>Tethered lipid film</subject><issn>0956-5663</issn><issn>1873-4235</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><recordid>eNqFkE1r3DAQhkVJoZttf0JBh1KSg1N9rGX7FEJI2sBCD9mehTwasyqW5UrakIX8-GqzITnmNHN43nmZh5CvnF1wxtWPe9bVqqqVkmddd84Yk6pSH8iCt42sVkLWJ2Txinwipyn9LVDDO7YgT5st0hnn7CxWGfMWI1o6utlZ6tH30UxITaKG9i545zE7oGmfMnqaA3UThDiHaDJS2OcA2xh8WWl4dNYkLECJDrsJsguTGcc9NWV9QDqE6D-Tj4MZE355mUvy5_Zmc_2rWv_-eXd9ta5AqiZXYhCMMylh1RtluZWCcyE5NxYVaxvoBetrXIkeBmn50IBgElvbs9qoAoJcku_Hu3MM_3aYsvYuAY5jeS7skhZ8Jdq2VCxJfQQhhpQiDnqOzpu415zpg2v97FofROqu08-utSq5by8FJoEZh2INXHoL86ZVNS_Y5RHD8uyDw6gTOJwArYsIWdvg3in6D6fblRQ</recordid><startdate>19991001</startdate><enddate>19991001</enddate><creator>Naumann, R.</creator><creator>Schmidt, E.K.</creator><creator>Jonczyk, A.</creator><creator>Fendler, K.</creator><creator>Kadenbach, B.</creator><creator>Liebermann, T.</creator><creator>Offenhäusser, A.</creator><creator>Knoll, W.</creator><general>Elsevier B.V</general><general>Elsevier Science</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19991001</creationdate><title>The peptide-tethered lipid membrane as a biomimetic system to incorporate cytochrome c oxidase in a functionally active form</title><author>Naumann, R. ; Schmidt, E.K. ; Jonczyk, A. ; Fendler, K. ; Kadenbach, B. ; Liebermann, T. ; Offenhäusser, A. ; Knoll, W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c367t-2f201033c4ba6d1d32112311ade6087cb20b5e42bcf3d1f7c203e8db05a6123c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><topic>Active ion transport</topic><topic>Antibody binding assay</topic><topic>Artificial membranes and reconstituted systems</topic><topic>Bioassay</topic><topic>Biological and medical sciences</topic><topic>Biological membranes</topic><topic>Biomimetic system</topic><topic>Chemisorption</topic><topic>Cytochrome c oxidase</topic><topic>Emission spectroscopy</topic><topic>Enzymes</topic><topic>Fluorescence</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>Impedance spectroscopy</topic><topic>Lipids</topic><topic>Membrane physicochemistry</topic><topic>Micelles</topic><topic>Molecular biophysics</topic><topic>Monolayers</topic><topic>Potentiometric sensors</topic><topic>Solid-supported lipid film</topic><topic>Surface plasmon fluorescence spectroscopy</topic><topic>Surface plasmon resonance spectroscopy</topic><topic>Tethered lipid film</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Naumann, R.</creatorcontrib><creatorcontrib>Schmidt, E.K.</creatorcontrib><creatorcontrib>Jonczyk, A.</creatorcontrib><creatorcontrib>Fendler, K.</creatorcontrib><creatorcontrib>Kadenbach, B.</creatorcontrib><creatorcontrib>Liebermann, T.</creatorcontrib><creatorcontrib>Offenhäusser, A.</creatorcontrib><creatorcontrib>Knoll, W.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><jtitle>Biosensors &amp; bioelectronics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Naumann, R.</au><au>Schmidt, E.K.</au><au>Jonczyk, A.</au><au>Fendler, K.</au><au>Kadenbach, B.</au><au>Liebermann, T.</au><au>Offenhäusser, A.</au><au>Knoll, W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The peptide-tethered lipid membrane as a biomimetic system to incorporate cytochrome c oxidase in a functionally active form</atitle><jtitle>Biosensors &amp; bioelectronics</jtitle><date>1999-10-01</date><risdate>1999</risdate><volume>14</volume><issue>7</issue><spage>651</spage><epage>662</epage><pages>651-662</pages><issn>0956-5663</issn><eissn>1873-4235</eissn><abstract>Peptide-supported lipid bilayers are investigated as a new class of solidsupported membranes tethered to the support by a peptide spacer. They are referred to as peptide tethered lipid membranes (tBLMs), formed by the fusion of liposomes with a thiopeptide-lipid monolayer chemisorbed on a gold support. Peptide tBLMs are designed as a biomimetic system to investigate integral membrane proteins. As an example, cytochrome c oxidase (COX) from bovine heart is incorporated into the preformed peptide tBLM by dilution of the solubilised protein below the critical micellar concentration. The formation of the lipid film as well as the incorporation of the protein were monitored by surface plasmon resonance spectroscopy and surface plasmon fluorescence spectroscopy. COX is activated by adding the reduced form of cytochrome c to the air-saturated buffer solution. Using electrochemical techniques, such as square wave voltammetry (SWV) and chronoamperometry (CA), the direct electron transfer between COX and the gold electrode is observed as well as proton transport from the inside to the outside across the lipid bilayer. Proton transport is then further investigated using impedance spectroscopy, although the electrode is shown to be only partially (70%) covered with a bilayer while defect domains with only a monolayer of peptide or peptide-lipid coexist (approx. 30%). Proton transport carried out by the COX is shown to be voltage dependent. This transport is indicated as a resistance in parallel to the resistance of the lipid film. As a consequence, the total resistance decreases as a function of the concentration of cytochrome c and increases again either by removal of the substrate or by addition of cyanide as an inhibitor of COX. The conductance in the presence of the activated enzyme correlates with the known turnover rate of COX. These experiments demonstrate the possibility to assess the activity of integral membrane proteins incorporated in peptide tBLMs using electrochemical techniques. The system could thus be promising for screening as well as biosensor applications.</abstract><cop>Lausanne</cop><pub>Elsevier B.V</pub><doi>10.1016/S0956-5663(99)00036-6</doi><tpages>12</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0956-5663
ispartof Biosensors & bioelectronics, 1999-10, Vol.14 (7), p.651-662
issn 0956-5663
1873-4235
language eng
recordid cdi_proquest_miscellaneous_21428810
source Access via ScienceDirect (Elsevier)
subjects Active ion transport
Antibody binding assay
Artificial membranes and reconstituted systems
Bioassay
Biological and medical sciences
Biological membranes
Biomimetic system
Chemisorption
Cytochrome c oxidase
Emission spectroscopy
Enzymes
Fluorescence
Fundamental and applied biological sciences. Psychology
Impedance spectroscopy
Lipids
Membrane physicochemistry
Micelles
Molecular biophysics
Monolayers
Potentiometric sensors
Solid-supported lipid film
Surface plasmon fluorescence spectroscopy
Surface plasmon resonance spectroscopy
Tethered lipid film
title The peptide-tethered lipid membrane as a biomimetic system to incorporate cytochrome c oxidase in a functionally active form
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-22T08%3A37%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20peptide-tethered%20lipid%20membrane%20as%20a%20biomimetic%20system%20to%20incorporate%20cytochrome%20c%20oxidase%20in%20a%20functionally%20active%20form&rft.jtitle=Biosensors%20&%20bioelectronics&rft.au=Naumann,%20R.&rft.date=1999-10-01&rft.volume=14&rft.issue=7&rft.spage=651&rft.epage=662&rft.pages=651-662&rft.issn=0956-5663&rft.eissn=1873-4235&rft_id=info:doi/10.1016/S0956-5663(99)00036-6&rft_dat=%3Cproquest_cross%3E435903%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=21428810&rft_id=info:pmid/&rft_els_id=S0956566399000366&rfr_iscdi=true