Photon counting and integrating analog gaseous detectors for digital scanning radiography

In this paper we consider two types of gaseous detectors for radiography. The first one, the Multiwire Proportional Chamber, is used at present as a part of the digital radiographic system. It works in counting mode, has a quantum efficiency of 30% and a spatial resolution of 0.6mm. Our new detector...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 1998-12, Vol.419 (2-3), p.290-294
Hauptverfasser: Babichev, E.A., Baru, S.E., Groshev, V.R., Khabakhpashev, A.G., Porosev, V.V., Savinov, G.A., Shekhtman, L.I., Telnov, V.I.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 294
container_issue 2-3
container_start_page 290
container_title Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
container_volume 419
creator Babichev, E.A.
Baru, S.E.
Groshev, V.R.
Khabakhpashev, A.G.
Porosev, V.V.
Savinov, G.A.
Shekhtman, L.I.
Telnov, V.I.
description In this paper we consider two types of gaseous detectors for radiography. The first one, the Multiwire Proportional Chamber, is used at present as a part of the digital radiographic system. It works in counting mode, has a quantum efficiency of 30% and a spatial resolution of 0.6mm. Our new detector, the Multistrip Ionisation Chamber, is filled with Xe at 10atm., has a quantum efficiency up to 70% and a spatial resolution of 0.4mm. This method with integration of collected charge allows to avoid the problems of counting rate and gas ageing and considerably reduces the cost of electronics.
doi_str_mv 10.1016/S0168-9002(98)00874-2
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_21393228</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0168900298008742</els_id><sourcerecordid>374427</sourcerecordid><originalsourceid>FETCH-LOGICAL-c338t-2ac359b01b6edff234db4c7d872383b7e63e988f5170e089cbdc00a8d0e44b643</originalsourceid><addsrcrecordid>eNqFkE1LAzEQhoMoWKs_QchJ9LCaj_1ITiLFLygoqAdPIZvMbiPbpCZbof_e3bZ4dQ4zDLzv8M6D0Dkl15TQ8uZtaCKThLBLKa4IEVWesQM0oaJimSyq8hBN_iTH6CSlLzKUrMQEfb4uQh88NmHte-dbrL3FzvfQRr3fdRda3OoEYZ2whR5MH2LCTYjYutb1usPJaO9HddTWhcG6WmxO0VGjuwRn-zlFHw_377OnbP7y-Dy7m2eGc9FnTBteyJrQugTbNIznts5NZYfsXPC6gpKDFKIpaEWACGlqawjRwhLI87rM-RRd7O6uYvheQ-rV0iUDXaf9mFgxyiVnTAzCYic0MaQUoVGr6JY6bhQlagSptiDVSElJobYgFRt8tzsfDF_8OIgqGQfegHVxYKFscP9c-AXfQHxt</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>21393228</pqid></control><display><type>article</type><title>Photon counting and integrating analog gaseous detectors for digital scanning radiography</title><source>Access via ScienceDirect (Elsevier)</source><creator>Babichev, E.A. ; Baru, S.E. ; Groshev, V.R. ; Khabakhpashev, A.G. ; Porosev, V.V. ; Savinov, G.A. ; Shekhtman, L.I. ; Telnov, V.I.</creator><creatorcontrib>Babichev, E.A. ; Baru, S.E. ; Groshev, V.R. ; Khabakhpashev, A.G. ; Porosev, V.V. ; Savinov, G.A. ; Shekhtman, L.I. ; Telnov, V.I.</creatorcontrib><description>In this paper we consider two types of gaseous detectors for radiography. The first one, the Multiwire Proportional Chamber, is used at present as a part of the digital radiographic system. It works in counting mode, has a quantum efficiency of 30% and a spatial resolution of 0.6mm. Our new detector, the Multistrip Ionisation Chamber, is filled with Xe at 10atm., has a quantum efficiency up to 70% and a spatial resolution of 0.4mm. This method with integration of collected charge allows to avoid the problems of counting rate and gas ageing and considerably reduces the cost of electronics.</description><identifier>ISSN: 0168-9002</identifier><identifier>EISSN: 1872-9576</identifier><identifier>DOI: 10.1016/S0168-9002(98)00874-2</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Ionization chambers ; Proportional counters ; Quantum efficiency ; X ray radiography</subject><ispartof>Nuclear instruments &amp; methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 1998-12, Vol.419 (2-3), p.290-294</ispartof><rights>1998 Elsevier Science B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c338t-2ac359b01b6edff234db4c7d872383b7e63e988f5170e089cbdc00a8d0e44b643</citedby><cites>FETCH-LOGICAL-c338t-2ac359b01b6edff234db4c7d872383b7e63e988f5170e089cbdc00a8d0e44b643</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0168-9002(98)00874-2$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids></links><search><creatorcontrib>Babichev, E.A.</creatorcontrib><creatorcontrib>Baru, S.E.</creatorcontrib><creatorcontrib>Groshev, V.R.</creatorcontrib><creatorcontrib>Khabakhpashev, A.G.</creatorcontrib><creatorcontrib>Porosev, V.V.</creatorcontrib><creatorcontrib>Savinov, G.A.</creatorcontrib><creatorcontrib>Shekhtman, L.I.</creatorcontrib><creatorcontrib>Telnov, V.I.</creatorcontrib><title>Photon counting and integrating analog gaseous detectors for digital scanning radiography</title><title>Nuclear instruments &amp; methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment</title><description>In this paper we consider two types of gaseous detectors for radiography. The first one, the Multiwire Proportional Chamber, is used at present as a part of the digital radiographic system. It works in counting mode, has a quantum efficiency of 30% and a spatial resolution of 0.6mm. Our new detector, the Multistrip Ionisation Chamber, is filled with Xe at 10atm., has a quantum efficiency up to 70% and a spatial resolution of 0.4mm. This method with integration of collected charge allows to avoid the problems of counting rate and gas ageing and considerably reduces the cost of electronics.</description><subject>Ionization chambers</subject><subject>Proportional counters</subject><subject>Quantum efficiency</subject><subject>X ray radiography</subject><issn>0168-9002</issn><issn>1872-9576</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNqFkE1LAzEQhoMoWKs_QchJ9LCaj_1ITiLFLygoqAdPIZvMbiPbpCZbof_e3bZ4dQ4zDLzv8M6D0Dkl15TQ8uZtaCKThLBLKa4IEVWesQM0oaJimSyq8hBN_iTH6CSlLzKUrMQEfb4uQh88NmHte-dbrL3FzvfQRr3fdRda3OoEYZ2whR5MH2LCTYjYutb1usPJaO9HddTWhcG6WmxO0VGjuwRn-zlFHw_377OnbP7y-Dy7m2eGc9FnTBteyJrQugTbNIznts5NZYfsXPC6gpKDFKIpaEWACGlqawjRwhLI87rM-RRd7O6uYvheQ-rV0iUDXaf9mFgxyiVnTAzCYic0MaQUoVGr6JY6bhQlagSptiDVSElJobYgFRt8tzsfDF_8OIgqGQfegHVxYKFscP9c-AXfQHxt</recordid><startdate>19981221</startdate><enddate>19981221</enddate><creator>Babichev, E.A.</creator><creator>Baru, S.E.</creator><creator>Groshev, V.R.</creator><creator>Khabakhpashev, A.G.</creator><creator>Porosev, V.V.</creator><creator>Savinov, G.A.</creator><creator>Shekhtman, L.I.</creator><creator>Telnov, V.I.</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19981221</creationdate><title>Photon counting and integrating analog gaseous detectors for digital scanning radiography</title><author>Babichev, E.A. ; Baru, S.E. ; Groshev, V.R. ; Khabakhpashev, A.G. ; Porosev, V.V. ; Savinov, G.A. ; Shekhtman, L.I. ; Telnov, V.I.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c338t-2ac359b01b6edff234db4c7d872383b7e63e988f5170e089cbdc00a8d0e44b643</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Ionization chambers</topic><topic>Proportional counters</topic><topic>Quantum efficiency</topic><topic>X ray radiography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Babichev, E.A.</creatorcontrib><creatorcontrib>Baru, S.E.</creatorcontrib><creatorcontrib>Groshev, V.R.</creatorcontrib><creatorcontrib>Khabakhpashev, A.G.</creatorcontrib><creatorcontrib>Porosev, V.V.</creatorcontrib><creatorcontrib>Savinov, G.A.</creatorcontrib><creatorcontrib>Shekhtman, L.I.</creatorcontrib><creatorcontrib>Telnov, V.I.</creatorcontrib><collection>CrossRef</collection><jtitle>Nuclear instruments &amp; methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Babichev, E.A.</au><au>Baru, S.E.</au><au>Groshev, V.R.</au><au>Khabakhpashev, A.G.</au><au>Porosev, V.V.</au><au>Savinov, G.A.</au><au>Shekhtman, L.I.</au><au>Telnov, V.I.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Photon counting and integrating analog gaseous detectors for digital scanning radiography</atitle><jtitle>Nuclear instruments &amp; methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment</jtitle><date>1998-12-21</date><risdate>1998</risdate><volume>419</volume><issue>2-3</issue><spage>290</spage><epage>294</epage><pages>290-294</pages><issn>0168-9002</issn><eissn>1872-9576</eissn><abstract>In this paper we consider two types of gaseous detectors for radiography. The first one, the Multiwire Proportional Chamber, is used at present as a part of the digital radiographic system. It works in counting mode, has a quantum efficiency of 30% and a spatial resolution of 0.6mm. Our new detector, the Multistrip Ionisation Chamber, is filled with Xe at 10atm., has a quantum efficiency up to 70% and a spatial resolution of 0.4mm. This method with integration of collected charge allows to avoid the problems of counting rate and gas ageing and considerably reduces the cost of electronics.</abstract><pub>Elsevier B.V</pub><doi>10.1016/S0168-9002(98)00874-2</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0168-9002
ispartof Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 1998-12, Vol.419 (2-3), p.290-294
issn 0168-9002
1872-9576
language eng
recordid cdi_proquest_miscellaneous_21393228
source Access via ScienceDirect (Elsevier)
subjects Ionization chambers
Proportional counters
Quantum efficiency
X ray radiography
title Photon counting and integrating analog gaseous detectors for digital scanning radiography
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-22T12%3A49%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Photon%20counting%20and%20integrating%20analog%20gaseous%20detectors%20for%20digital%20scanning%20radiography&rft.jtitle=Nuclear%20instruments%20&%20methods%20in%20physics%20research.%20Section%20A,%20Accelerators,%20spectrometers,%20detectors%20and%20associated%20equipment&rft.au=Babichev,%20E.A.&rft.date=1998-12-21&rft.volume=419&rft.issue=2-3&rft.spage=290&rft.epage=294&rft.pages=290-294&rft.issn=0168-9002&rft.eissn=1872-9576&rft_id=info:doi/10.1016/S0168-9002(98)00874-2&rft_dat=%3Cproquest_cross%3E374427%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=21393228&rft_id=info:pmid/&rft_els_id=S0168900298008742&rfr_iscdi=true