Photon counting and integrating analog gaseous detectors for digital scanning radiography
In this paper we consider two types of gaseous detectors for radiography. The first one, the Multiwire Proportional Chamber, is used at present as a part of the digital radiographic system. It works in counting mode, has a quantum efficiency of 30% and a spatial resolution of 0.6mm. Our new detector...
Gespeichert in:
Veröffentlicht in: | Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 1998-12, Vol.419 (2-3), p.290-294 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 294 |
---|---|
container_issue | 2-3 |
container_start_page | 290 |
container_title | Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment |
container_volume | 419 |
creator | Babichev, E.A. Baru, S.E. Groshev, V.R. Khabakhpashev, A.G. Porosev, V.V. Savinov, G.A. Shekhtman, L.I. Telnov, V.I. |
description | In this paper we consider two types of gaseous detectors for radiography. The first one, the Multiwire Proportional Chamber, is used at present as a part of the digital radiographic system. It works in counting mode, has a quantum efficiency of 30% and a spatial resolution of 0.6mm. Our new detector, the Multistrip Ionisation Chamber, is filled with Xe at 10atm., has a quantum efficiency up to 70% and a spatial resolution of 0.4mm. This method with integration of collected charge allows to avoid the problems of counting rate and gas ageing and considerably reduces the cost of electronics. |
doi_str_mv | 10.1016/S0168-9002(98)00874-2 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_21393228</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0168900298008742</els_id><sourcerecordid>374427</sourcerecordid><originalsourceid>FETCH-LOGICAL-c338t-2ac359b01b6edff234db4c7d872383b7e63e988f5170e089cbdc00a8d0e44b643</originalsourceid><addsrcrecordid>eNqFkE1LAzEQhoMoWKs_QchJ9LCaj_1ITiLFLygoqAdPIZvMbiPbpCZbof_e3bZ4dQ4zDLzv8M6D0Dkl15TQ8uZtaCKThLBLKa4IEVWesQM0oaJimSyq8hBN_iTH6CSlLzKUrMQEfb4uQh88NmHte-dbrL3FzvfQRr3fdRda3OoEYZ2whR5MH2LCTYjYutb1usPJaO9HddTWhcG6WmxO0VGjuwRn-zlFHw_377OnbP7y-Dy7m2eGc9FnTBteyJrQugTbNIznts5NZYfsXPC6gpKDFKIpaEWACGlqawjRwhLI87rM-RRd7O6uYvheQ-rV0iUDXaf9mFgxyiVnTAzCYic0MaQUoVGr6JY6bhQlagSptiDVSElJobYgFRt8tzsfDF_8OIgqGQfegHVxYKFscP9c-AXfQHxt</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>21393228</pqid></control><display><type>article</type><title>Photon counting and integrating analog gaseous detectors for digital scanning radiography</title><source>Access via ScienceDirect (Elsevier)</source><creator>Babichev, E.A. ; Baru, S.E. ; Groshev, V.R. ; Khabakhpashev, A.G. ; Porosev, V.V. ; Savinov, G.A. ; Shekhtman, L.I. ; Telnov, V.I.</creator><creatorcontrib>Babichev, E.A. ; Baru, S.E. ; Groshev, V.R. ; Khabakhpashev, A.G. ; Porosev, V.V. ; Savinov, G.A. ; Shekhtman, L.I. ; Telnov, V.I.</creatorcontrib><description>In this paper we consider two types of gaseous detectors for radiography. The first one, the Multiwire Proportional Chamber, is used at present as a part of the digital radiographic system. It works in counting mode, has a quantum efficiency of 30% and a spatial resolution of 0.6mm. Our new detector, the Multistrip Ionisation Chamber, is filled with Xe at 10atm., has a quantum efficiency up to 70% and a spatial resolution of 0.4mm. This method with integration of collected charge allows to avoid the problems of counting rate and gas ageing and considerably reduces the cost of electronics.</description><identifier>ISSN: 0168-9002</identifier><identifier>EISSN: 1872-9576</identifier><identifier>DOI: 10.1016/S0168-9002(98)00874-2</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Ionization chambers ; Proportional counters ; Quantum efficiency ; X ray radiography</subject><ispartof>Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 1998-12, Vol.419 (2-3), p.290-294</ispartof><rights>1998 Elsevier Science B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c338t-2ac359b01b6edff234db4c7d872383b7e63e988f5170e089cbdc00a8d0e44b643</citedby><cites>FETCH-LOGICAL-c338t-2ac359b01b6edff234db4c7d872383b7e63e988f5170e089cbdc00a8d0e44b643</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0168-9002(98)00874-2$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids></links><search><creatorcontrib>Babichev, E.A.</creatorcontrib><creatorcontrib>Baru, S.E.</creatorcontrib><creatorcontrib>Groshev, V.R.</creatorcontrib><creatorcontrib>Khabakhpashev, A.G.</creatorcontrib><creatorcontrib>Porosev, V.V.</creatorcontrib><creatorcontrib>Savinov, G.A.</creatorcontrib><creatorcontrib>Shekhtman, L.I.</creatorcontrib><creatorcontrib>Telnov, V.I.</creatorcontrib><title>Photon counting and integrating analog gaseous detectors for digital scanning radiography</title><title>Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment</title><description>In this paper we consider two types of gaseous detectors for radiography. The first one, the Multiwire Proportional Chamber, is used at present as a part of the digital radiographic system. It works in counting mode, has a quantum efficiency of 30% and a spatial resolution of 0.6mm. Our new detector, the Multistrip Ionisation Chamber, is filled with Xe at 10atm., has a quantum efficiency up to 70% and a spatial resolution of 0.4mm. This method with integration of collected charge allows to avoid the problems of counting rate and gas ageing and considerably reduces the cost of electronics.</description><subject>Ionization chambers</subject><subject>Proportional counters</subject><subject>Quantum efficiency</subject><subject>X ray radiography</subject><issn>0168-9002</issn><issn>1872-9576</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNqFkE1LAzEQhoMoWKs_QchJ9LCaj_1ITiLFLygoqAdPIZvMbiPbpCZbof_e3bZ4dQ4zDLzv8M6D0Dkl15TQ8uZtaCKThLBLKa4IEVWesQM0oaJimSyq8hBN_iTH6CSlLzKUrMQEfb4uQh88NmHte-dbrL3FzvfQRr3fdRda3OoEYZ2whR5MH2LCTYjYutb1usPJaO9HddTWhcG6WmxO0VGjuwRn-zlFHw_377OnbP7y-Dy7m2eGc9FnTBteyJrQugTbNIznts5NZYfsXPC6gpKDFKIpaEWACGlqawjRwhLI87rM-RRd7O6uYvheQ-rV0iUDXaf9mFgxyiVnTAzCYic0MaQUoVGr6JY6bhQlagSptiDVSElJobYgFRt8tzsfDF_8OIgqGQfegHVxYKFscP9c-AXfQHxt</recordid><startdate>19981221</startdate><enddate>19981221</enddate><creator>Babichev, E.A.</creator><creator>Baru, S.E.</creator><creator>Groshev, V.R.</creator><creator>Khabakhpashev, A.G.</creator><creator>Porosev, V.V.</creator><creator>Savinov, G.A.</creator><creator>Shekhtman, L.I.</creator><creator>Telnov, V.I.</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19981221</creationdate><title>Photon counting and integrating analog gaseous detectors for digital scanning radiography</title><author>Babichev, E.A. ; Baru, S.E. ; Groshev, V.R. ; Khabakhpashev, A.G. ; Porosev, V.V. ; Savinov, G.A. ; Shekhtman, L.I. ; Telnov, V.I.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c338t-2ac359b01b6edff234db4c7d872383b7e63e988f5170e089cbdc00a8d0e44b643</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Ionization chambers</topic><topic>Proportional counters</topic><topic>Quantum efficiency</topic><topic>X ray radiography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Babichev, E.A.</creatorcontrib><creatorcontrib>Baru, S.E.</creatorcontrib><creatorcontrib>Groshev, V.R.</creatorcontrib><creatorcontrib>Khabakhpashev, A.G.</creatorcontrib><creatorcontrib>Porosev, V.V.</creatorcontrib><creatorcontrib>Savinov, G.A.</creatorcontrib><creatorcontrib>Shekhtman, L.I.</creatorcontrib><creatorcontrib>Telnov, V.I.</creatorcontrib><collection>CrossRef</collection><jtitle>Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Babichev, E.A.</au><au>Baru, S.E.</au><au>Groshev, V.R.</au><au>Khabakhpashev, A.G.</au><au>Porosev, V.V.</au><au>Savinov, G.A.</au><au>Shekhtman, L.I.</au><au>Telnov, V.I.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Photon counting and integrating analog gaseous detectors for digital scanning radiography</atitle><jtitle>Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment</jtitle><date>1998-12-21</date><risdate>1998</risdate><volume>419</volume><issue>2-3</issue><spage>290</spage><epage>294</epage><pages>290-294</pages><issn>0168-9002</issn><eissn>1872-9576</eissn><abstract>In this paper we consider two types of gaseous detectors for radiography. The first one, the Multiwire Proportional Chamber, is used at present as a part of the digital radiographic system. It works in counting mode, has a quantum efficiency of 30% and a spatial resolution of 0.6mm. Our new detector, the Multistrip Ionisation Chamber, is filled with Xe at 10atm., has a quantum efficiency up to 70% and a spatial resolution of 0.4mm. This method with integration of collected charge allows to avoid the problems of counting rate and gas ageing and considerably reduces the cost of electronics.</abstract><pub>Elsevier B.V</pub><doi>10.1016/S0168-9002(98)00874-2</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0168-9002 |
ispartof | Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 1998-12, Vol.419 (2-3), p.290-294 |
issn | 0168-9002 1872-9576 |
language | eng |
recordid | cdi_proquest_miscellaneous_21393228 |
source | Access via ScienceDirect (Elsevier) |
subjects | Ionization chambers Proportional counters Quantum efficiency X ray radiography |
title | Photon counting and integrating analog gaseous detectors for digital scanning radiography |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-22T12%3A49%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Photon%20counting%20and%20integrating%20analog%20gaseous%20detectors%20for%20digital%20scanning%20radiography&rft.jtitle=Nuclear%20instruments%20&%20methods%20in%20physics%20research.%20Section%20A,%20Accelerators,%20spectrometers,%20detectors%20and%20associated%20equipment&rft.au=Babichev,%20E.A.&rft.date=1998-12-21&rft.volume=419&rft.issue=2-3&rft.spage=290&rft.epage=294&rft.pages=290-294&rft.issn=0168-9002&rft.eissn=1872-9576&rft_id=info:doi/10.1016/S0168-9002(98)00874-2&rft_dat=%3Cproquest_cross%3E374427%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=21393228&rft_id=info:pmid/&rft_els_id=S0168900298008742&rfr_iscdi=true |