Portable cell-based biosensor system for toxin detection

A portable cell-based biosensor has been developed and characterized. The prototype system relies on extracellular recording from excitable cells cultured over an array of platinized gold microelectrodes. Extracellular potentials were bandpass filtered between 80 Hz to 2.8 kHz and amplified with a s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sensors and actuators. B, Chemical Chemical, 1998-01, Vol.53 (3), p.179-185
Hauptverfasser: Pancrazio, Joseph J, Bey Jr, Paul P, Cuttino, David S, Kusel, Julian K, Borkholder, David A, Shaffer, Kara M, Kovacs, Gregory T.A, Stenger, David A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 185
container_issue 3
container_start_page 179
container_title Sensors and actuators. B, Chemical
container_volume 53
creator Pancrazio, Joseph J
Bey Jr, Paul P
Cuttino, David S
Kusel, Julian K
Borkholder, David A
Shaffer, Kara M
Kovacs, Gregory T.A
Stenger, David A
description A portable cell-based biosensor has been developed and characterized. The prototype system relies on extracellular recording from excitable cells cultured over an array of platinized gold microelectrodes. Extracellular potentials were bandpass filtered between 80 Hz to 2.8 kHz and amplified with a selectable gain of either 1000 or 5000. The input-referred noise level of the system was only 8.7 μV RMS in the laboratory setting, reaching only 10.6 μV RMS in an outdoor environment, more than sufficient for measurement of extracellular potentials from excitable cells. The system also incorporates a feedback control system for temperature regulation and a 36-channel multiplexer for selection of up to four output channels for simultaneous display. Wherever possible, low-cost ‘off-the-shelf’ components were utilized in this prototype biosensor design. Using this system, extracellular recordings from chick myocardiocytes were performed under both laboratory and outdoor conditions.
doi_str_mv 10.1016/S0925-4005(98)00340-2
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_21361260</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0925400598003402</els_id><sourcerecordid>399655</sourcerecordid><originalsourceid>FETCH-LOGICAL-c375t-8a21a6f870c4a3d48f958fb3e7b9263c039860b0c3ec75cfd762f3d3b0f631153</originalsourceid><addsrcrecordid>eNqFkE9LAzEQxYMoWKsfQdiT6GF1ktlNsieR4j8oKKjnkM1OINJuarIV--3dWvHqad7hvce8H2OnHC45cHn1Ao2oywqgPm_0BQBWUIo9NuFaYYmg1D6b_FkO2VHO7wBQoYQJ088xDbZdUOFosShbm6kr2hAz9TmmIm_yQMvCj3KIX6EvOhrIDSH2x-zA20Wmk987ZW93t6-zh3L-dP84u5mXDlU9lNoKbqXXClxlsau0b2rtWyTVNkKiA2y0hBYcklO1852SwmOHLXiJnNc4ZWe73lWKH2vKg1mGvP3V9hTX2QiOkgsJo7HeGV2KOSfyZpXC0qaN4WC2nMwPJ7OFYBptfjgZMeaudzkaV3wGSia7QL2jLqRxquli-KfhG6Z_buw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>21361260</pqid></control><display><type>article</type><title>Portable cell-based biosensor system for toxin detection</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Pancrazio, Joseph J ; Bey Jr, Paul P ; Cuttino, David S ; Kusel, Julian K ; Borkholder, David A ; Shaffer, Kara M ; Kovacs, Gregory T.A ; Stenger, David A</creator><creatorcontrib>Pancrazio, Joseph J ; Bey Jr, Paul P ; Cuttino, David S ; Kusel, Julian K ; Borkholder, David A ; Shaffer, Kara M ; Kovacs, Gregory T.A ; Stenger, David A</creatorcontrib><description>A portable cell-based biosensor has been developed and characterized. The prototype system relies on extracellular recording from excitable cells cultured over an array of platinized gold microelectrodes. Extracellular potentials were bandpass filtered between 80 Hz to 2.8 kHz and amplified with a selectable gain of either 1000 or 5000. The input-referred noise level of the system was only 8.7 μV RMS in the laboratory setting, reaching only 10.6 μV RMS in an outdoor environment, more than sufficient for measurement of extracellular potentials from excitable cells. The system also incorporates a feedback control system for temperature regulation and a 36-channel multiplexer for selection of up to four output channels for simultaneous display. Wherever possible, low-cost ‘off-the-shelf’ components were utilized in this prototype biosensor design. Using this system, extracellular recordings from chick myocardiocytes were performed under both laboratory and outdoor conditions.</description><identifier>ISSN: 0925-4005</identifier><identifier>EISSN: 1873-3077</identifier><identifier>DOI: 10.1016/S0925-4005(98)00340-2</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Amplifier ; Antibodies ; Biosensor ; Cardiac myocytes ; Cell culture ; Electrochemical electrodes ; Extracellular recording ; Feedback control ; Portable ; Portable equipment ; Toxicity</subject><ispartof>Sensors and actuators. B, Chemical, 1998-01, Vol.53 (3), p.179-185</ispartof><rights>1999 Elsevier Science S.A.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c375t-8a21a6f870c4a3d48f958fb3e7b9263c039860b0c3ec75cfd762f3d3b0f631153</citedby><cites>FETCH-LOGICAL-c375t-8a21a6f870c4a3d48f958fb3e7b9263c039860b0c3ec75cfd762f3d3b0f631153</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0925400598003402$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Pancrazio, Joseph J</creatorcontrib><creatorcontrib>Bey Jr, Paul P</creatorcontrib><creatorcontrib>Cuttino, David S</creatorcontrib><creatorcontrib>Kusel, Julian K</creatorcontrib><creatorcontrib>Borkholder, David A</creatorcontrib><creatorcontrib>Shaffer, Kara M</creatorcontrib><creatorcontrib>Kovacs, Gregory T.A</creatorcontrib><creatorcontrib>Stenger, David A</creatorcontrib><title>Portable cell-based biosensor system for toxin detection</title><title>Sensors and actuators. B, Chemical</title><description>A portable cell-based biosensor has been developed and characterized. The prototype system relies on extracellular recording from excitable cells cultured over an array of platinized gold microelectrodes. Extracellular potentials were bandpass filtered between 80 Hz to 2.8 kHz and amplified with a selectable gain of either 1000 or 5000. The input-referred noise level of the system was only 8.7 μV RMS in the laboratory setting, reaching only 10.6 μV RMS in an outdoor environment, more than sufficient for measurement of extracellular potentials from excitable cells. The system also incorporates a feedback control system for temperature regulation and a 36-channel multiplexer for selection of up to four output channels for simultaneous display. Wherever possible, low-cost ‘off-the-shelf’ components were utilized in this prototype biosensor design. Using this system, extracellular recordings from chick myocardiocytes were performed under both laboratory and outdoor conditions.</description><subject>Amplifier</subject><subject>Antibodies</subject><subject>Biosensor</subject><subject>Cardiac myocytes</subject><subject>Cell culture</subject><subject>Electrochemical electrodes</subject><subject>Extracellular recording</subject><subject>Feedback control</subject><subject>Portable</subject><subject>Portable equipment</subject><subject>Toxicity</subject><issn>0925-4005</issn><issn>1873-3077</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNqFkE9LAzEQxYMoWKsfQdiT6GF1ktlNsieR4j8oKKjnkM1OINJuarIV--3dWvHqad7hvce8H2OnHC45cHn1Ao2oywqgPm_0BQBWUIo9NuFaYYmg1D6b_FkO2VHO7wBQoYQJ088xDbZdUOFosShbm6kr2hAz9TmmIm_yQMvCj3KIX6EvOhrIDSH2x-zA20Wmk987ZW93t6-zh3L-dP84u5mXDlU9lNoKbqXXClxlsau0b2rtWyTVNkKiA2y0hBYcklO1852SwmOHLXiJnNc4ZWe73lWKH2vKg1mGvP3V9hTX2QiOkgsJo7HeGV2KOSfyZpXC0qaN4WC2nMwPJ7OFYBptfjgZMeaudzkaV3wGSia7QL2jLqRxquli-KfhG6Z_buw</recordid><startdate>19980101</startdate><enddate>19980101</enddate><creator>Pancrazio, Joseph J</creator><creator>Bey Jr, Paul P</creator><creator>Cuttino, David S</creator><creator>Kusel, Julian K</creator><creator>Borkholder, David A</creator><creator>Shaffer, Kara M</creator><creator>Kovacs, Gregory T.A</creator><creator>Stenger, David A</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19980101</creationdate><title>Portable cell-based biosensor system for toxin detection</title><author>Pancrazio, Joseph J ; Bey Jr, Paul P ; Cuttino, David S ; Kusel, Julian K ; Borkholder, David A ; Shaffer, Kara M ; Kovacs, Gregory T.A ; Stenger, David A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c375t-8a21a6f870c4a3d48f958fb3e7b9263c039860b0c3ec75cfd762f3d3b0f631153</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Amplifier</topic><topic>Antibodies</topic><topic>Biosensor</topic><topic>Cardiac myocytes</topic><topic>Cell culture</topic><topic>Electrochemical electrodes</topic><topic>Extracellular recording</topic><topic>Feedback control</topic><topic>Portable</topic><topic>Portable equipment</topic><topic>Toxicity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Pancrazio, Joseph J</creatorcontrib><creatorcontrib>Bey Jr, Paul P</creatorcontrib><creatorcontrib>Cuttino, David S</creatorcontrib><creatorcontrib>Kusel, Julian K</creatorcontrib><creatorcontrib>Borkholder, David A</creatorcontrib><creatorcontrib>Shaffer, Kara M</creatorcontrib><creatorcontrib>Kovacs, Gregory T.A</creatorcontrib><creatorcontrib>Stenger, David A</creatorcontrib><collection>CrossRef</collection><jtitle>Sensors and actuators. B, Chemical</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Pancrazio, Joseph J</au><au>Bey Jr, Paul P</au><au>Cuttino, David S</au><au>Kusel, Julian K</au><au>Borkholder, David A</au><au>Shaffer, Kara M</au><au>Kovacs, Gregory T.A</au><au>Stenger, David A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Portable cell-based biosensor system for toxin detection</atitle><jtitle>Sensors and actuators. B, Chemical</jtitle><date>1998-01-01</date><risdate>1998</risdate><volume>53</volume><issue>3</issue><spage>179</spage><epage>185</epage><pages>179-185</pages><issn>0925-4005</issn><eissn>1873-3077</eissn><abstract>A portable cell-based biosensor has been developed and characterized. The prototype system relies on extracellular recording from excitable cells cultured over an array of platinized gold microelectrodes. Extracellular potentials were bandpass filtered between 80 Hz to 2.8 kHz and amplified with a selectable gain of either 1000 or 5000. The input-referred noise level of the system was only 8.7 μV RMS in the laboratory setting, reaching only 10.6 μV RMS in an outdoor environment, more than sufficient for measurement of extracellular potentials from excitable cells. The system also incorporates a feedback control system for temperature regulation and a 36-channel multiplexer for selection of up to four output channels for simultaneous display. Wherever possible, low-cost ‘off-the-shelf’ components were utilized in this prototype biosensor design. Using this system, extracellular recordings from chick myocardiocytes were performed under both laboratory and outdoor conditions.</abstract><pub>Elsevier B.V</pub><doi>10.1016/S0925-4005(98)00340-2</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0925-4005
ispartof Sensors and actuators. B, Chemical, 1998-01, Vol.53 (3), p.179-185
issn 0925-4005
1873-3077
language eng
recordid cdi_proquest_miscellaneous_21361260
source Elsevier ScienceDirect Journals Complete
subjects Amplifier
Antibodies
Biosensor
Cardiac myocytes
Cell culture
Electrochemical electrodes
Extracellular recording
Feedback control
Portable
Portable equipment
Toxicity
title Portable cell-based biosensor system for toxin detection
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-11T23%3A23%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Portable%20cell-based%20biosensor%20system%20for%20toxin%20detection&rft.jtitle=Sensors%20and%20actuators.%20B,%20Chemical&rft.au=Pancrazio,%20Joseph%20J&rft.date=1998-01-01&rft.volume=53&rft.issue=3&rft.spage=179&rft.epage=185&rft.pages=179-185&rft.issn=0925-4005&rft.eissn=1873-3077&rft_id=info:doi/10.1016/S0925-4005(98)00340-2&rft_dat=%3Cproquest_cross%3E399655%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=21361260&rft_id=info:pmid/&rft_els_id=S0925400598003402&rfr_iscdi=true