Relation between the electric field and activation of cortical neurons in transcranial electrical stimulation

To address the brain areas and circuits affected by transcranial electrical stimulation (tES), which had been used widely to treat psychiatric and neurological diseases, the stimulus-induced electric field in the cortex was calculated using a head model that reflects anatomical information. To obtai...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Brain stimulation 2019-03, Vol.12 (2), p.275-289
Hauptverfasser: Seo, Hyeon, Jun, Sung Chan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 289
container_issue 2
container_start_page 275
container_title Brain stimulation
container_volume 12
creator Seo, Hyeon
Jun, Sung Chan
description To address the brain areas and circuits affected by transcranial electrical stimulation (tES), which had been used widely to treat psychiatric and neurological diseases, the stimulus-induced electric field in the cortex was calculated using a head model that reflects anatomical information. To obtain detailed information at the macroscopic and microscopic levels, multi-scale modeling was proposed that integrates the head model with multi-compartmental models of cortical neurons. Our goal was to use multi-scale modeling to describe the relation between the stimulus-induced electric field and neuronal responses during tES. We simulated sub- and supra-threshold neuronal responses to stimulus-induced uniform and realistic electric fields. For the realistic electric field, multi-scale models that combined the head model derived from structural MRIs and multi-compartmental models of neurons were constructed. Then, we simulated the steady-state membrane polarization for sub-threshold stimulation and the excitation threshold for supra-threshold stimulation by varying the tES montages. The electric field calculated was decomposed into two orthogonal components, the radial and tangential fields, which were compared to the neuronal responses. The stimulus-induced electric field depended strongly on stimulus parameters, and neuronal excitability showed a higher correlation with the radial field. We demonstrated that neurons exhibited linear polarization during sub-threshold stimulation depending on the local radial field intensity that resulted in a significant relation regardless of the tES montage. Supra-threshold stimulation showed a stronger relation with the radial field, but rather complex patterns of excitation thresholds depending on neurons’ morphological features. Our results indicated that cortical neurons are affected greatly by the relative direction of the stimulus-induced electric field, which may be a necessary step toward a detailed understanding of tES’ potential mechanisms. •We proposed the multi-scale models that combine the head model and neuronal models.•We analyzed the relation between electric field and neuronal excitability.•Neuronal excitability showed a strong correlation with the radial field for sub/supra-threshold stimulations.•Supra-threshold stimulation yielded complex patterns of excitation thresholds.•The multi-scale models may improve understanding at macroscopic and microscopic levels.
doi_str_mv 10.1016/j.brs.2018.11.004
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2135643466</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1935861X1830370X</els_id><sourcerecordid>2135643466</sourcerecordid><originalsourceid>FETCH-LOGICAL-c419t-de1b6babd491d70f37a2eef0c81b87aa6ca08a15359ecf99ff05c3c5aaac95743</originalsourceid><addsrcrecordid>eNp9kMtq3TAURUVpaR7tB2RSPOzEjs7VwxYZhdA8IBAIDWQm5OMjoosfqSSn9O-r4KTDDiQdxNpbaDF2ArwBDvp03_QxNTsOXQPQcC4_sEPoWl3LVsmPZTZC1Z2GxwN2lNKec2VM135mB4JLabRQh2y6p9HlsMxVT_k30VzlJ6poJMwxYOUDjUPl5rIwh5eNXHyFS8wB3VjNtMZlTlUowejmhGUL5f69oYwph2ndHvnCPnk3Jvr6dh6zh8sfPy-u69u7q5uL89saJZhcDwS97l0_SANDy71o3Y7Ic-yg71rnNDreOVBCGUJvjPdcoUDlnEOjWimO2fet9zkuv1ZK2U4hIY2jm2lZk92BUFoKqXVBYUMxLilF8vY5hsnFPxa4fbVs97ZYtq-WLYAtlkvm21v92k80_Eu8ay3A2QZQ-eRLoGgTBpqRhhCLFzss4T_1fwGVIZDE</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2135643466</pqid></control><display><type>article</type><title>Relation between the electric field and activation of cortical neurons in transcranial electrical stimulation</title><source>Elsevier ScienceDirect Journals</source><creator>Seo, Hyeon ; Jun, Sung Chan</creator><creatorcontrib>Seo, Hyeon ; Jun, Sung Chan</creatorcontrib><description>To address the brain areas and circuits affected by transcranial electrical stimulation (tES), which had been used widely to treat psychiatric and neurological diseases, the stimulus-induced electric field in the cortex was calculated using a head model that reflects anatomical information. To obtain detailed information at the macroscopic and microscopic levels, multi-scale modeling was proposed that integrates the head model with multi-compartmental models of cortical neurons. Our goal was to use multi-scale modeling to describe the relation between the stimulus-induced electric field and neuronal responses during tES. We simulated sub- and supra-threshold neuronal responses to stimulus-induced uniform and realistic electric fields. For the realistic electric field, multi-scale models that combined the head model derived from structural MRIs and multi-compartmental models of neurons were constructed. Then, we simulated the steady-state membrane polarization for sub-threshold stimulation and the excitation threshold for supra-threshold stimulation by varying the tES montages. The electric field calculated was decomposed into two orthogonal components, the radial and tangential fields, which were compared to the neuronal responses. The stimulus-induced electric field depended strongly on stimulus parameters, and neuronal excitability showed a higher correlation with the radial field. We demonstrated that neurons exhibited linear polarization during sub-threshold stimulation depending on the local radial field intensity that resulted in a significant relation regardless of the tES montage. Supra-threshold stimulation showed a stronger relation with the radial field, but rather complex patterns of excitation thresholds depending on neurons’ morphological features. Our results indicated that cortical neurons are affected greatly by the relative direction of the stimulus-induced electric field, which may be a necessary step toward a detailed understanding of tES’ potential mechanisms. •We proposed the multi-scale models that combine the head model and neuronal models.•We analyzed the relation between electric field and neuronal excitability.•Neuronal excitability showed a strong correlation with the radial field for sub/supra-threshold stimulations.•Supra-threshold stimulation yielded complex patterns of excitation thresholds.•The multi-scale models may improve understanding at macroscopic and microscopic levels.</description><identifier>ISSN: 1935-861X</identifier><identifier>EISSN: 1876-4754</identifier><identifier>DOI: 10.1016/j.brs.2018.11.004</identifier><identifier>PMID: 30449635</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Finite element method ; Multi-scale modeling ; Noninvasive brain stimulation ; Pyramidal neuron ; Transcranial electrical stimulation</subject><ispartof>Brain stimulation, 2019-03, Vol.12 (2), p.275-289</ispartof><rights>2018 Elsevier Inc.</rights><rights>Copyright © 2018 Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c419t-de1b6babd491d70f37a2eef0c81b87aa6ca08a15359ecf99ff05c3c5aaac95743</citedby><cites>FETCH-LOGICAL-c419t-de1b6babd491d70f37a2eef0c81b87aa6ca08a15359ecf99ff05c3c5aaac95743</cites><orcidid>0000-0001-8488-3733 ; 0000-0001-5357-4436</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S1935861X1830370X$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30449635$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Seo, Hyeon</creatorcontrib><creatorcontrib>Jun, Sung Chan</creatorcontrib><title>Relation between the electric field and activation of cortical neurons in transcranial electrical stimulation</title><title>Brain stimulation</title><addtitle>Brain Stimul</addtitle><description>To address the brain areas and circuits affected by transcranial electrical stimulation (tES), which had been used widely to treat psychiatric and neurological diseases, the stimulus-induced electric field in the cortex was calculated using a head model that reflects anatomical information. To obtain detailed information at the macroscopic and microscopic levels, multi-scale modeling was proposed that integrates the head model with multi-compartmental models of cortical neurons. Our goal was to use multi-scale modeling to describe the relation between the stimulus-induced electric field and neuronal responses during tES. We simulated sub- and supra-threshold neuronal responses to stimulus-induced uniform and realistic electric fields. For the realistic electric field, multi-scale models that combined the head model derived from structural MRIs and multi-compartmental models of neurons were constructed. Then, we simulated the steady-state membrane polarization for sub-threshold stimulation and the excitation threshold for supra-threshold stimulation by varying the tES montages. The electric field calculated was decomposed into two orthogonal components, the radial and tangential fields, which were compared to the neuronal responses. The stimulus-induced electric field depended strongly on stimulus parameters, and neuronal excitability showed a higher correlation with the radial field. We demonstrated that neurons exhibited linear polarization during sub-threshold stimulation depending on the local radial field intensity that resulted in a significant relation regardless of the tES montage. Supra-threshold stimulation showed a stronger relation with the radial field, but rather complex patterns of excitation thresholds depending on neurons’ morphological features. Our results indicated that cortical neurons are affected greatly by the relative direction of the stimulus-induced electric field, which may be a necessary step toward a detailed understanding of tES’ potential mechanisms. •We proposed the multi-scale models that combine the head model and neuronal models.•We analyzed the relation between electric field and neuronal excitability.•Neuronal excitability showed a strong correlation with the radial field for sub/supra-threshold stimulations.•Supra-threshold stimulation yielded complex patterns of excitation thresholds.•The multi-scale models may improve understanding at macroscopic and microscopic levels.</description><subject>Finite element method</subject><subject>Multi-scale modeling</subject><subject>Noninvasive brain stimulation</subject><subject>Pyramidal neuron</subject><subject>Transcranial electrical stimulation</subject><issn>1935-861X</issn><issn>1876-4754</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp9kMtq3TAURUVpaR7tB2RSPOzEjs7VwxYZhdA8IBAIDWQm5OMjoosfqSSn9O-r4KTDDiQdxNpbaDF2ArwBDvp03_QxNTsOXQPQcC4_sEPoWl3LVsmPZTZC1Z2GxwN2lNKec2VM135mB4JLabRQh2y6p9HlsMxVT_k30VzlJ6poJMwxYOUDjUPl5rIwh5eNXHyFS8wB3VjNtMZlTlUowejmhGUL5f69oYwph2ndHvnCPnk3Jvr6dh6zh8sfPy-u69u7q5uL89saJZhcDwS97l0_SANDy71o3Y7Ic-yg71rnNDreOVBCGUJvjPdcoUDlnEOjWimO2fet9zkuv1ZK2U4hIY2jm2lZk92BUFoKqXVBYUMxLilF8vY5hsnFPxa4fbVs97ZYtq-WLYAtlkvm21v92k80_Eu8ay3A2QZQ-eRLoGgTBpqRhhCLFzss4T_1fwGVIZDE</recordid><startdate>201903</startdate><enddate>201903</enddate><creator>Seo, Hyeon</creator><creator>Jun, Sung Chan</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-8488-3733</orcidid><orcidid>https://orcid.org/0000-0001-5357-4436</orcidid></search><sort><creationdate>201903</creationdate><title>Relation between the electric field and activation of cortical neurons in transcranial electrical stimulation</title><author>Seo, Hyeon ; Jun, Sung Chan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c419t-de1b6babd491d70f37a2eef0c81b87aa6ca08a15359ecf99ff05c3c5aaac95743</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Finite element method</topic><topic>Multi-scale modeling</topic><topic>Noninvasive brain stimulation</topic><topic>Pyramidal neuron</topic><topic>Transcranial electrical stimulation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Seo, Hyeon</creatorcontrib><creatorcontrib>Jun, Sung Chan</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Brain stimulation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Seo, Hyeon</au><au>Jun, Sung Chan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Relation between the electric field and activation of cortical neurons in transcranial electrical stimulation</atitle><jtitle>Brain stimulation</jtitle><addtitle>Brain Stimul</addtitle><date>2019-03</date><risdate>2019</risdate><volume>12</volume><issue>2</issue><spage>275</spage><epage>289</epage><pages>275-289</pages><issn>1935-861X</issn><eissn>1876-4754</eissn><abstract>To address the brain areas and circuits affected by transcranial electrical stimulation (tES), which had been used widely to treat psychiatric and neurological diseases, the stimulus-induced electric field in the cortex was calculated using a head model that reflects anatomical information. To obtain detailed information at the macroscopic and microscopic levels, multi-scale modeling was proposed that integrates the head model with multi-compartmental models of cortical neurons. Our goal was to use multi-scale modeling to describe the relation between the stimulus-induced electric field and neuronal responses during tES. We simulated sub- and supra-threshold neuronal responses to stimulus-induced uniform and realistic electric fields. For the realistic electric field, multi-scale models that combined the head model derived from structural MRIs and multi-compartmental models of neurons were constructed. Then, we simulated the steady-state membrane polarization for sub-threshold stimulation and the excitation threshold for supra-threshold stimulation by varying the tES montages. The electric field calculated was decomposed into two orthogonal components, the radial and tangential fields, which were compared to the neuronal responses. The stimulus-induced electric field depended strongly on stimulus parameters, and neuronal excitability showed a higher correlation with the radial field. We demonstrated that neurons exhibited linear polarization during sub-threshold stimulation depending on the local radial field intensity that resulted in a significant relation regardless of the tES montage. Supra-threshold stimulation showed a stronger relation with the radial field, but rather complex patterns of excitation thresholds depending on neurons’ morphological features. Our results indicated that cortical neurons are affected greatly by the relative direction of the stimulus-induced electric field, which may be a necessary step toward a detailed understanding of tES’ potential mechanisms. •We proposed the multi-scale models that combine the head model and neuronal models.•We analyzed the relation between electric field and neuronal excitability.•Neuronal excitability showed a strong correlation with the radial field for sub/supra-threshold stimulations.•Supra-threshold stimulation yielded complex patterns of excitation thresholds.•The multi-scale models may improve understanding at macroscopic and microscopic levels.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>30449635</pmid><doi>10.1016/j.brs.2018.11.004</doi><tpages>15</tpages><orcidid>https://orcid.org/0000-0001-8488-3733</orcidid><orcidid>https://orcid.org/0000-0001-5357-4436</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1935-861X
ispartof Brain stimulation, 2019-03, Vol.12 (2), p.275-289
issn 1935-861X
1876-4754
language eng
recordid cdi_proquest_miscellaneous_2135643466
source Elsevier ScienceDirect Journals
subjects Finite element method
Multi-scale modeling
Noninvasive brain stimulation
Pyramidal neuron
Transcranial electrical stimulation
title Relation between the electric field and activation of cortical neurons in transcranial electrical stimulation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T20%3A50%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Relation%20between%20the%20electric%20field%20and%20activation%20of%20cortical%20neurons%20in%20transcranial%20electrical%20stimulation&rft.jtitle=Brain%20stimulation&rft.au=Seo,%20Hyeon&rft.date=2019-03&rft.volume=12&rft.issue=2&rft.spage=275&rft.epage=289&rft.pages=275-289&rft.issn=1935-861X&rft.eissn=1876-4754&rft_id=info:doi/10.1016/j.brs.2018.11.004&rft_dat=%3Cproquest_cross%3E2135643466%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2135643466&rft_id=info:pmid/30449635&rft_els_id=S1935861X1830370X&rfr_iscdi=true