Ascending aorta measurements as assessed by ECG-gated multi-detector computed tomography: a pilot study to establish normative values for transcatheter therapies
The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels...
Gespeichert in:
Veröffentlicht in: | European radiology 2009-03, Vol.19 (3), p.664-669 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 669 |
---|---|
container_issue | 3 |
container_start_page | 664 |
container_title | European radiology |
container_volume | 19 |
creator | Lu, Tri-Linh C. Huber, Christoph H. Rizzo, Elena Dehmeshki, Jashmid von Segesser, Ludwig K. Qanadli, Salah D. |
description | The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3 ± 3.4, coronary sinus 34.2 ± 4.1, sino-tubular junction 29.7 ± 3.4 and mid ascending aorta 32.7 ± 3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6 ± 11.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1 ± 3.7, and between both coronary ostia 7.2 ± 3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 ± 9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.6 ± 3.3, CV 13–43%. Mean aortic valve area was 582.0 ± 131.9 mm
2
. The variation of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered. |
doi_str_mv | 10.1007/s00330-008-1182-8 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_21318651</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1895617601</sourcerecordid><originalsourceid>FETCH-LOGICAL-p209t-2831d84423bdc8c078884dc73b4cb45b79bd3d517944f86e16e3ae1e3e2feddf3</originalsourceid><addsrcrecordid>eNpdkc9q3DAQh0VpabZpH6CXInrITe3oz67k3sKSpIVAL8lZyNZ418GyXEkO7OP0TSuzKYXCgBjNx8cwP0I-cvjCAfTXDCAlMADDODeCmVdkw5UUjINRr8kGGmmYbhp1Qd7l_AQADVf6LbngxnBQW7Ehv69zh5MfpgN1MRVHA7q8JAw4lUzdWhlredqe6M3-jh1cqU1YxjIwjwW7EhPtYpiX9b_EEA_JzcfTN-roPIyx0FwWf6oTirm4dhzykU4xBVeGZ6TPblww075KSnJT7lw5Vmvtjlg9A-b35E3vxowfXt5L8nh787D_zu5_3v3YX9-zWUBTmDCSe6OUkK3vTAfaGKN8p2WrulZtW920Xvot141Svdkh36F0yFGi6NH7Xl6Sq7N3TvFX3anYMNTbjKObMC7ZCi652W15BT__Bz7FJU11t8qYBrSWK_TpBVragN7OaQgunezfy1dAnIFcR9MB0z8LB7vGa8_x2hqvXeO1Rv4B0VeZeA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>218907731</pqid></control><display><type>article</type><title>Ascending aorta measurements as assessed by ECG-gated multi-detector computed tomography: a pilot study to establish normative values for transcatheter therapies</title><source>MEDLINE</source><source>SpringerLink Journals - AutoHoldings</source><creator>Lu, Tri-Linh C. ; Huber, Christoph H. ; Rizzo, Elena ; Dehmeshki, Jashmid ; von Segesser, Ludwig K. ; Qanadli, Salah D.</creator><creatorcontrib>Lu, Tri-Linh C. ; Huber, Christoph H. ; Rizzo, Elena ; Dehmeshki, Jashmid ; von Segesser, Ludwig K. ; Qanadli, Salah D.</creatorcontrib><description>The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3 ± 3.4, coronary sinus 34.2 ± 4.1, sino-tubular junction 29.7 ± 3.4 and mid ascending aorta 32.7 ± 3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6 ± 11.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1 ± 3.7, and between both coronary ostia 7.2 ± 3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 ± 9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.6 ± 3.3, CV 13–43%. Mean aortic valve area was 582.0 ± 131.9 mm
2
. The variation of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.</description><identifier>ISSN: 0938-7994</identifier><identifier>EISSN: 1432-1084</identifier><identifier>DOI: 10.1007/s00330-008-1182-8</identifier><identifier>PMID: 18810452</identifier><language>eng</language><publisher>Berlin/Heidelberg: Springer-Verlag</publisher><subject>Adult ; Age Factors ; Aged ; Aged, 80 and over ; Angiography - methods ; Aorta - anatomy & histology ; Aorta - pathology ; Aortic aneurysms ; Aortic Valve - pathology ; Beta blockers ; Cardiovascular disease ; Coronary vessels ; Diagnostic Radiology ; Electrocardiography - methods ; Electrocutions ; Female ; Humans ; Imaging ; Internal Medicine ; Interventional Radiology ; Male ; Medical imaging ; Medicine ; Medicine & Public Health ; Middle Aged ; Neuroradiology ; Pilot Projects ; Radiology ; Reference Values ; Sensors ; Software ; Tomography ; Tomography, X-Ray Computed - methods ; Ultrasound ; Vascular-Interventional</subject><ispartof>European radiology, 2009-03, Vol.19 (3), p.664-669</ispartof><rights>European Society of Radiology 2008</rights><rights>European Society of Radiology 2009</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-p209t-2831d84423bdc8c078884dc73b4cb45b79bd3d517944f86e16e3ae1e3e2feddf3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s00330-008-1182-8$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s00330-008-1182-8$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,41488,42557,51319</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18810452$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lu, Tri-Linh C.</creatorcontrib><creatorcontrib>Huber, Christoph H.</creatorcontrib><creatorcontrib>Rizzo, Elena</creatorcontrib><creatorcontrib>Dehmeshki, Jashmid</creatorcontrib><creatorcontrib>von Segesser, Ludwig K.</creatorcontrib><creatorcontrib>Qanadli, Salah D.</creatorcontrib><title>Ascending aorta measurements as assessed by ECG-gated multi-detector computed tomography: a pilot study to establish normative values for transcatheter therapies</title><title>European radiology</title><addtitle>Eur Radiol</addtitle><addtitle>Eur Radiol</addtitle><description>The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3 ± 3.4, coronary sinus 34.2 ± 4.1, sino-tubular junction 29.7 ± 3.4 and mid ascending aorta 32.7 ± 3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6 ± 11.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1 ± 3.7, and between both coronary ostia 7.2 ± 3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 ± 9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.6 ± 3.3, CV 13–43%. Mean aortic valve area was 582.0 ± 131.9 mm
2
. The variation of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.</description><subject>Adult</subject><subject>Age Factors</subject><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Angiography - methods</subject><subject>Aorta - anatomy & histology</subject><subject>Aorta - pathology</subject><subject>Aortic aneurysms</subject><subject>Aortic Valve - pathology</subject><subject>Beta blockers</subject><subject>Cardiovascular disease</subject><subject>Coronary vessels</subject><subject>Diagnostic Radiology</subject><subject>Electrocardiography - methods</subject><subject>Electrocutions</subject><subject>Female</subject><subject>Humans</subject><subject>Imaging</subject><subject>Internal Medicine</subject><subject>Interventional Radiology</subject><subject>Male</subject><subject>Medical imaging</subject><subject>Medicine</subject><subject>Medicine & Public Health</subject><subject>Middle Aged</subject><subject>Neuroradiology</subject><subject>Pilot Projects</subject><subject>Radiology</subject><subject>Reference Values</subject><subject>Sensors</subject><subject>Software</subject><subject>Tomography</subject><subject>Tomography, X-Ray Computed - methods</subject><subject>Ultrasound</subject><subject>Vascular-Interventional</subject><issn>0938-7994</issn><issn>1432-1084</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNpdkc9q3DAQh0VpabZpH6CXInrITe3oz67k3sKSpIVAL8lZyNZ418GyXEkO7OP0TSuzKYXCgBjNx8cwP0I-cvjCAfTXDCAlMADDODeCmVdkw5UUjINRr8kGGmmYbhp1Qd7l_AQADVf6LbngxnBQW7Ehv69zh5MfpgN1MRVHA7q8JAw4lUzdWhlredqe6M3-jh1cqU1YxjIwjwW7EhPtYpiX9b_EEA_JzcfTN-roPIyx0FwWf6oTirm4dhzykU4xBVeGZ6TPblww075KSnJT7lw5Vmvtjlg9A-b35E3vxowfXt5L8nh787D_zu5_3v3YX9-zWUBTmDCSe6OUkK3vTAfaGKN8p2WrulZtW920Xvot141Svdkh36F0yFGi6NH7Xl6Sq7N3TvFX3anYMNTbjKObMC7ZCi652W15BT__Bz7FJU11t8qYBrSWK_TpBVragN7OaQgunezfy1dAnIFcR9MB0z8LB7vGa8_x2hqvXeO1Rv4B0VeZeA</recordid><startdate>20090301</startdate><enddate>20090301</enddate><creator>Lu, Tri-Linh C.</creator><creator>Huber, Christoph H.</creator><creator>Rizzo, Elena</creator><creator>Dehmeshki, Jashmid</creator><creator>von Segesser, Ludwig K.</creator><creator>Qanadli, Salah D.</creator><general>Springer-Verlag</general><general>Springer Nature B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>3V.</scope><scope>7QO</scope><scope>7RV</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FR3</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>KB0</scope><scope>LK8</scope><scope>M0S</scope><scope>M1P</scope><scope>M7P</scope><scope>NAPCQ</scope><scope>P5Z</scope><scope>P62</scope><scope>P64</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>20090301</creationdate><title>Ascending aorta measurements as assessed by ECG-gated multi-detector computed tomography: a pilot study to establish normative values for transcatheter therapies</title><author>Lu, Tri-Linh C. ; Huber, Christoph H. ; Rizzo, Elena ; Dehmeshki, Jashmid ; von Segesser, Ludwig K. ; Qanadli, Salah D.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p209t-2831d84423bdc8c078884dc73b4cb45b79bd3d517944f86e16e3ae1e3e2feddf3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Adult</topic><topic>Age Factors</topic><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Angiography - methods</topic><topic>Aorta - anatomy & histology</topic><topic>Aorta - pathology</topic><topic>Aortic aneurysms</topic><topic>Aortic Valve - pathology</topic><topic>Beta blockers</topic><topic>Cardiovascular disease</topic><topic>Coronary vessels</topic><topic>Diagnostic Radiology</topic><topic>Electrocardiography - methods</topic><topic>Electrocutions</topic><topic>Female</topic><topic>Humans</topic><topic>Imaging</topic><topic>Internal Medicine</topic><topic>Interventional Radiology</topic><topic>Male</topic><topic>Medical imaging</topic><topic>Medicine</topic><topic>Medicine & Public Health</topic><topic>Middle Aged</topic><topic>Neuroradiology</topic><topic>Pilot Projects</topic><topic>Radiology</topic><topic>Reference Values</topic><topic>Sensors</topic><topic>Software</topic><topic>Tomography</topic><topic>Tomography, X-Ray Computed - methods</topic><topic>Ultrasound</topic><topic>Vascular-Interventional</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lu, Tri-Linh C.</creatorcontrib><creatorcontrib>Huber, Christoph H.</creatorcontrib><creatorcontrib>Rizzo, Elena</creatorcontrib><creatorcontrib>Dehmeshki, Jashmid</creatorcontrib><creatorcontrib>von Segesser, Ludwig K.</creatorcontrib><creatorcontrib>Qanadli, Salah D.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>ProQuest Central (Corporate)</collection><collection>Biotechnology Research Abstracts</collection><collection>Nursing & Allied Health Database</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies & Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Engineering Research Database</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Nursing & Allied Health Database (Alumni Edition)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Biological Science Database</collection><collection>Nursing & Allied Health Premium</collection><collection>Advanced Technologies & Aerospace Database</collection><collection>ProQuest Advanced Technologies & Aerospace Collection</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>European radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lu, Tri-Linh C.</au><au>Huber, Christoph H.</au><au>Rizzo, Elena</au><au>Dehmeshki, Jashmid</au><au>von Segesser, Ludwig K.</au><au>Qanadli, Salah D.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Ascending aorta measurements as assessed by ECG-gated multi-detector computed tomography: a pilot study to establish normative values for transcatheter therapies</atitle><jtitle>European radiology</jtitle><stitle>Eur Radiol</stitle><addtitle>Eur Radiol</addtitle><date>2009-03-01</date><risdate>2009</risdate><volume>19</volume><issue>3</issue><spage>664</spage><epage>669</epage><pages>664-669</pages><issn>0938-7994</issn><eissn>1432-1084</eissn><abstract>The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3 ± 3.4, coronary sinus 34.2 ± 4.1, sino-tubular junction 29.7 ± 3.4 and mid ascending aorta 32.7 ± 3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6 ± 11.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1 ± 3.7, and between both coronary ostia 7.2 ± 3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 ± 9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.6 ± 3.3, CV 13–43%. Mean aortic valve area was 582.0 ± 131.9 mm
2
. The variation of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.</abstract><cop>Berlin/Heidelberg</cop><pub>Springer-Verlag</pub><pmid>18810452</pmid><doi>10.1007/s00330-008-1182-8</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0938-7994 |
ispartof | European radiology, 2009-03, Vol.19 (3), p.664-669 |
issn | 0938-7994 1432-1084 |
language | eng |
recordid | cdi_proquest_miscellaneous_21318651 |
source | MEDLINE; SpringerLink Journals - AutoHoldings |
subjects | Adult Age Factors Aged Aged, 80 and over Angiography - methods Aorta - anatomy & histology Aorta - pathology Aortic aneurysms Aortic Valve - pathology Beta blockers Cardiovascular disease Coronary vessels Diagnostic Radiology Electrocardiography - methods Electrocutions Female Humans Imaging Internal Medicine Interventional Radiology Male Medical imaging Medicine Medicine & Public Health Middle Aged Neuroradiology Pilot Projects Radiology Reference Values Sensors Software Tomography Tomography, X-Ray Computed - methods Ultrasound Vascular-Interventional |
title | Ascending aorta measurements as assessed by ECG-gated multi-detector computed tomography: a pilot study to establish normative values for transcatheter therapies |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T13%3A50%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Ascending%20aorta%20measurements%20as%20assessed%20by%20ECG-gated%20multi-detector%20computed%20tomography:%20a%20pilot%20study%20to%20establish%20normative%20values%20for%20transcatheter%20therapies&rft.jtitle=European%20radiology&rft.au=Lu,%20Tri-Linh%20C.&rft.date=2009-03-01&rft.volume=19&rft.issue=3&rft.spage=664&rft.epage=669&rft.pages=664-669&rft.issn=0938-7994&rft.eissn=1432-1084&rft_id=info:doi/10.1007/s00330-008-1182-8&rft_dat=%3Cproquest_pubme%3E1895617601%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=218907731&rft_id=info:pmid/18810452&rfr_iscdi=true |