Industrial radiotracer application in flow rate measurement and flowmeter calibration using 99mTc and 198Au nanoparticles radioisotope

The flow rate or fluid velocity measurement is important to maintain fluid flow quality performance in the systems. This study focuses on determination of volumetric flow rate measurement and to calibrate the conventional flowmeter using industrial radiotracer approach in quadrilateral gas-liquid bu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied radiation and isotopes 2019-01, Vol.143, p.24-28
Hauptverfasser: Mohd Yunos, Mohd Amirul Syafiq, Hussain, Siti Aslina, Sipaun, Susan Maria
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 28
container_issue
container_start_page 24
container_title Applied radiation and isotopes
container_volume 143
creator Mohd Yunos, Mohd Amirul Syafiq
Hussain, Siti Aslina
Sipaun, Susan Maria
description The flow rate or fluid velocity measurement is important to maintain fluid flow quality performance in the systems. This study focuses on determination of volumetric flow rate measurement and to calibrate the conventional flowmeter using industrial radiotracer approach in quadrilateral gas-liquid bubble column reactor. In this work, two different radioisotopes which emit γ-ray have been chosen as radioactive tracer which is 99mTc produced from 99Mo/99mTc radioisotope generator and 198Au nanoparticle form neutron activation at research nuclear reactor TRIGA Mark II. Both radioisotopes representing liquid and solid tracer purposely designed for tracing liquid flow. The peak to peak radiotracer method known as pulse velocity method was applied to determine the volumetric flow rate. The radiation signals were monitored using 4 unit NaI scintillation detectors located at 4 different points nearby the inlet and outlet of the quadrilateral bubble column reactor process stream. The water volume inside the bubble column reactor was fixed at 0.04 m3 and liquid flow rates in this reactor were specified on installed flowmeter at different reference value which is 4 lpm, 8 lpm, and 12 lpm, respectively. The experimental result shows very good linearity and repeatability by following the theoretical equations with less uncertainty in volumetric flow rate measurement. The obtained results also validated the effectiveness of the proposed method for the installed flowmeter calibration efficiency. •The flow rate of liquid phase was measured using 99mTc and 198Au industrial radiotracer.•The peak to peak radiotracer method was applied to determine the volumetric flow rates.•Validation of the suitability of tracer physical form for radiotracer techniques.•Quadrilateral bubble column reactor model was used to simulate process stream.•Calibration of conventional flowmeter using radiotracer method was compared and validated.
doi_str_mv 10.1016/j.apradiso.2018.10.008
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2126911295</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0969804317314823</els_id><sourcerecordid>2126911295</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1905-86d287531c3eb7a9ae74efd54bdd7dde3727d83bd466258537dc0e51cea125cd3</originalsourceid><addsrcrecordid>eNqFUMlOwzAQtRBIlOUXUI5cUmxns29UFUulSlzK2ZraU-QqsYPtgPgBvpu0gTOnkd42M4-QG0bnjLL6bj-HPoCx0c85ZWIE55SKEzJjouG5FJSekhmVtcwFLYtzchHjnlJaCsln5HvlzBBTsNBmhxCfAmgMGfR9azUk611mXbZr_efIJ8w6hDgE7NClDJw5Mh2m0aKhtdswWYZo3VsmZbfRRxWTYjFkDpzvISSrW4zTuvHq5Hu8Imc7aCNe_85L8vr4sFk-5-uXp9Vysc41k7TKRW24aKqC6QK3DUjApsSdqcqtMY0xWDS8MaLYmrKueSWqojGaYsU0AuOVNsUluZ1y--DfB4xJdTZqbFtw6IeoOOO1ZIzLapTWk1QHH2PAneqD7SB8KUbVoXi1V3_Fq0PxB3wsfjTeT0YcH_mwGFTUFp1GYwPqpIy3_0X8ACRPkzM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2126911295</pqid></control><display><type>article</type><title>Industrial radiotracer application in flow rate measurement and flowmeter calibration using 99mTc and 198Au nanoparticles radioisotope</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Mohd Yunos, Mohd Amirul Syafiq ; Hussain, Siti Aslina ; Sipaun, Susan Maria</creator><creatorcontrib>Mohd Yunos, Mohd Amirul Syafiq ; Hussain, Siti Aslina ; Sipaun, Susan Maria</creatorcontrib><description>The flow rate or fluid velocity measurement is important to maintain fluid flow quality performance in the systems. This study focuses on determination of volumetric flow rate measurement and to calibrate the conventional flowmeter using industrial radiotracer approach in quadrilateral gas-liquid bubble column reactor. In this work, two different radioisotopes which emit γ-ray have been chosen as radioactive tracer which is 99mTc produced from 99Mo/99mTc radioisotope generator and 198Au nanoparticle form neutron activation at research nuclear reactor TRIGA Mark II. Both radioisotopes representing liquid and solid tracer purposely designed for tracing liquid flow. The peak to peak radiotracer method known as pulse velocity method was applied to determine the volumetric flow rate. The radiation signals were monitored using 4 unit NaI scintillation detectors located at 4 different points nearby the inlet and outlet of the quadrilateral bubble column reactor process stream. The water volume inside the bubble column reactor was fixed at 0.04 m3 and liquid flow rates in this reactor were specified on installed flowmeter at different reference value which is 4 lpm, 8 lpm, and 12 lpm, respectively. The experimental result shows very good linearity and repeatability by following the theoretical equations with less uncertainty in volumetric flow rate measurement. The obtained results also validated the effectiveness of the proposed method for the installed flowmeter calibration efficiency. •The flow rate of liquid phase was measured using 99mTc and 198Au industrial radiotracer.•The peak to peak radiotracer method was applied to determine the volumetric flow rates.•Validation of the suitability of tracer physical form for radiotracer techniques.•Quadrilateral bubble column reactor model was used to simulate process stream.•Calibration of conventional flowmeter using radiotracer method was compared and validated.</description><identifier>ISSN: 0969-8043</identifier><identifier>EISSN: 1872-9800</identifier><identifier>DOI: 10.1016/j.apradiso.2018.10.008</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Bubble column ; Closed conduit ; Flowrate measurement ; Gold nanoparticle tracer ; Industrial radiotracer ; Scintillation detector</subject><ispartof>Applied radiation and isotopes, 2019-01, Vol.143, p.24-28</ispartof><rights>2018 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c1905-86d287531c3eb7a9ae74efd54bdd7dde3727d83bd466258537dc0e51cea125cd3</citedby><cites>FETCH-LOGICAL-c1905-86d287531c3eb7a9ae74efd54bdd7dde3727d83bd466258537dc0e51cea125cd3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0969804317314823$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Mohd Yunos, Mohd Amirul Syafiq</creatorcontrib><creatorcontrib>Hussain, Siti Aslina</creatorcontrib><creatorcontrib>Sipaun, Susan Maria</creatorcontrib><title>Industrial radiotracer application in flow rate measurement and flowmeter calibration using 99mTc and 198Au nanoparticles radioisotope</title><title>Applied radiation and isotopes</title><description>The flow rate or fluid velocity measurement is important to maintain fluid flow quality performance in the systems. This study focuses on determination of volumetric flow rate measurement and to calibrate the conventional flowmeter using industrial radiotracer approach in quadrilateral gas-liquid bubble column reactor. In this work, two different radioisotopes which emit γ-ray have been chosen as radioactive tracer which is 99mTc produced from 99Mo/99mTc radioisotope generator and 198Au nanoparticle form neutron activation at research nuclear reactor TRIGA Mark II. Both radioisotopes representing liquid and solid tracer purposely designed for tracing liquid flow. The peak to peak radiotracer method known as pulse velocity method was applied to determine the volumetric flow rate. The radiation signals were monitored using 4 unit NaI scintillation detectors located at 4 different points nearby the inlet and outlet of the quadrilateral bubble column reactor process stream. The water volume inside the bubble column reactor was fixed at 0.04 m3 and liquid flow rates in this reactor were specified on installed flowmeter at different reference value which is 4 lpm, 8 lpm, and 12 lpm, respectively. The experimental result shows very good linearity and repeatability by following the theoretical equations with less uncertainty in volumetric flow rate measurement. The obtained results also validated the effectiveness of the proposed method for the installed flowmeter calibration efficiency. •The flow rate of liquid phase was measured using 99mTc and 198Au industrial radiotracer.•The peak to peak radiotracer method was applied to determine the volumetric flow rates.•Validation of the suitability of tracer physical form for radiotracer techniques.•Quadrilateral bubble column reactor model was used to simulate process stream.•Calibration of conventional flowmeter using radiotracer method was compared and validated.</description><subject>Bubble column</subject><subject>Closed conduit</subject><subject>Flowrate measurement</subject><subject>Gold nanoparticle tracer</subject><subject>Industrial radiotracer</subject><subject>Scintillation detector</subject><issn>0969-8043</issn><issn>1872-9800</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNqFUMlOwzAQtRBIlOUXUI5cUmxns29UFUulSlzK2ZraU-QqsYPtgPgBvpu0gTOnkd42M4-QG0bnjLL6bj-HPoCx0c85ZWIE55SKEzJjouG5FJSekhmVtcwFLYtzchHjnlJaCsln5HvlzBBTsNBmhxCfAmgMGfR9azUk611mXbZr_efIJ8w6hDgE7NClDJw5Mh2m0aKhtdswWYZo3VsmZbfRRxWTYjFkDpzvISSrW4zTuvHq5Hu8Imc7aCNe_85L8vr4sFk-5-uXp9Vysc41k7TKRW24aKqC6QK3DUjApsSdqcqtMY0xWDS8MaLYmrKueSWqojGaYsU0AuOVNsUluZ1y--DfB4xJdTZqbFtw6IeoOOO1ZIzLapTWk1QHH2PAneqD7SB8KUbVoXi1V3_Fq0PxB3wsfjTeT0YcH_mwGFTUFp1GYwPqpIy3_0X8ACRPkzM</recordid><startdate>201901</startdate><enddate>201901</enddate><creator>Mohd Yunos, Mohd Amirul Syafiq</creator><creator>Hussain, Siti Aslina</creator><creator>Sipaun, Susan Maria</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201901</creationdate><title>Industrial radiotracer application in flow rate measurement and flowmeter calibration using 99mTc and 198Au nanoparticles radioisotope</title><author>Mohd Yunos, Mohd Amirul Syafiq ; Hussain, Siti Aslina ; Sipaun, Susan Maria</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1905-86d287531c3eb7a9ae74efd54bdd7dde3727d83bd466258537dc0e51cea125cd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Bubble column</topic><topic>Closed conduit</topic><topic>Flowrate measurement</topic><topic>Gold nanoparticle tracer</topic><topic>Industrial radiotracer</topic><topic>Scintillation detector</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mohd Yunos, Mohd Amirul Syafiq</creatorcontrib><creatorcontrib>Hussain, Siti Aslina</creatorcontrib><creatorcontrib>Sipaun, Susan Maria</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Applied radiation and isotopes</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mohd Yunos, Mohd Amirul Syafiq</au><au>Hussain, Siti Aslina</au><au>Sipaun, Susan Maria</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Industrial radiotracer application in flow rate measurement and flowmeter calibration using 99mTc and 198Au nanoparticles radioisotope</atitle><jtitle>Applied radiation and isotopes</jtitle><date>2019-01</date><risdate>2019</risdate><volume>143</volume><spage>24</spage><epage>28</epage><pages>24-28</pages><issn>0969-8043</issn><eissn>1872-9800</eissn><abstract>The flow rate or fluid velocity measurement is important to maintain fluid flow quality performance in the systems. This study focuses on determination of volumetric flow rate measurement and to calibrate the conventional flowmeter using industrial radiotracer approach in quadrilateral gas-liquid bubble column reactor. In this work, two different radioisotopes which emit γ-ray have been chosen as radioactive tracer which is 99mTc produced from 99Mo/99mTc radioisotope generator and 198Au nanoparticle form neutron activation at research nuclear reactor TRIGA Mark II. Both radioisotopes representing liquid and solid tracer purposely designed for tracing liquid flow. The peak to peak radiotracer method known as pulse velocity method was applied to determine the volumetric flow rate. The radiation signals were monitored using 4 unit NaI scintillation detectors located at 4 different points nearby the inlet and outlet of the quadrilateral bubble column reactor process stream. The water volume inside the bubble column reactor was fixed at 0.04 m3 and liquid flow rates in this reactor were specified on installed flowmeter at different reference value which is 4 lpm, 8 lpm, and 12 lpm, respectively. The experimental result shows very good linearity and repeatability by following the theoretical equations with less uncertainty in volumetric flow rate measurement. The obtained results also validated the effectiveness of the proposed method for the installed flowmeter calibration efficiency. •The flow rate of liquid phase was measured using 99mTc and 198Au industrial radiotracer.•The peak to peak radiotracer method was applied to determine the volumetric flow rates.•Validation of the suitability of tracer physical form for radiotracer techniques.•Quadrilateral bubble column reactor model was used to simulate process stream.•Calibration of conventional flowmeter using radiotracer method was compared and validated.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.apradiso.2018.10.008</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0969-8043
ispartof Applied radiation and isotopes, 2019-01, Vol.143, p.24-28
issn 0969-8043
1872-9800
language eng
recordid cdi_proquest_miscellaneous_2126911295
source Elsevier ScienceDirect Journals Complete
subjects Bubble column
Closed conduit
Flowrate measurement
Gold nanoparticle tracer
Industrial radiotracer
Scintillation detector
title Industrial radiotracer application in flow rate measurement and flowmeter calibration using 99mTc and 198Au nanoparticles radioisotope
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T22%3A34%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Industrial%20radiotracer%20application%20in%20flow%20rate%20measurement%20and%20flowmeter%20calibration%20using%2099mTc%20and%20198Au%20nanoparticles%20radioisotope&rft.jtitle=Applied%20radiation%20and%20isotopes&rft.au=Mohd%20Yunos,%20Mohd%20Amirul%20Syafiq&rft.date=2019-01&rft.volume=143&rft.spage=24&rft.epage=28&rft.pages=24-28&rft.issn=0969-8043&rft.eissn=1872-9800&rft_id=info:doi/10.1016/j.apradiso.2018.10.008&rft_dat=%3Cproquest_cross%3E2126911295%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2126911295&rft_id=info:pmid/&rft_els_id=S0969804317314823&rfr_iscdi=true