Industrial radiotracer application in flow rate measurement and flowmeter calibration using 99mTc and 198Au nanoparticles radioisotope
The flow rate or fluid velocity measurement is important to maintain fluid flow quality performance in the systems. This study focuses on determination of volumetric flow rate measurement and to calibrate the conventional flowmeter using industrial radiotracer approach in quadrilateral gas-liquid bu...
Gespeichert in:
Veröffentlicht in: | Applied radiation and isotopes 2019-01, Vol.143, p.24-28 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 28 |
---|---|
container_issue | |
container_start_page | 24 |
container_title | Applied radiation and isotopes |
container_volume | 143 |
creator | Mohd Yunos, Mohd Amirul Syafiq Hussain, Siti Aslina Sipaun, Susan Maria |
description | The flow rate or fluid velocity measurement is important to maintain fluid flow quality performance in the systems. This study focuses on determination of volumetric flow rate measurement and to calibrate the conventional flowmeter using industrial radiotracer approach in quadrilateral gas-liquid bubble column reactor. In this work, two different radioisotopes which emit γ-ray have been chosen as radioactive tracer which is 99mTc produced from 99Mo/99mTc radioisotope generator and 198Au nanoparticle form neutron activation at research nuclear reactor TRIGA Mark II. Both radioisotopes representing liquid and solid tracer purposely designed for tracing liquid flow. The peak to peak radiotracer method known as pulse velocity method was applied to determine the volumetric flow rate. The radiation signals were monitored using 4 unit NaI scintillation detectors located at 4 different points nearby the inlet and outlet of the quadrilateral bubble column reactor process stream. The water volume inside the bubble column reactor was fixed at 0.04 m3 and liquid flow rates in this reactor were specified on installed flowmeter at different reference value which is 4 lpm, 8 lpm, and 12 lpm, respectively. The experimental result shows very good linearity and repeatability by following the theoretical equations with less uncertainty in volumetric flow rate measurement. The obtained results also validated the effectiveness of the proposed method for the installed flowmeter calibration efficiency.
•The flow rate of liquid phase was measured using 99mTc and 198Au industrial radiotracer.•The peak to peak radiotracer method was applied to determine the volumetric flow rates.•Validation of the suitability of tracer physical form for radiotracer techniques.•Quadrilateral bubble column reactor model was used to simulate process stream.•Calibration of conventional flowmeter using radiotracer method was compared and validated. |
doi_str_mv | 10.1016/j.apradiso.2018.10.008 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2126911295</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0969804317314823</els_id><sourcerecordid>2126911295</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1905-86d287531c3eb7a9ae74efd54bdd7dde3727d83bd466258537dc0e51cea125cd3</originalsourceid><addsrcrecordid>eNqFUMlOwzAQtRBIlOUXUI5cUmxns29UFUulSlzK2ZraU-QqsYPtgPgBvpu0gTOnkd42M4-QG0bnjLL6bj-HPoCx0c85ZWIE55SKEzJjouG5FJSekhmVtcwFLYtzchHjnlJaCsln5HvlzBBTsNBmhxCfAmgMGfR9azUk611mXbZr_efIJ8w6hDgE7NClDJw5Mh2m0aKhtdswWYZo3VsmZbfRRxWTYjFkDpzvISSrW4zTuvHq5Hu8Imc7aCNe_85L8vr4sFk-5-uXp9Vysc41k7TKRW24aKqC6QK3DUjApsSdqcqtMY0xWDS8MaLYmrKueSWqojGaYsU0AuOVNsUluZ1y--DfB4xJdTZqbFtw6IeoOOO1ZIzLapTWk1QHH2PAneqD7SB8KUbVoXi1V3_Fq0PxB3wsfjTeT0YcH_mwGFTUFp1GYwPqpIy3_0X8ACRPkzM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2126911295</pqid></control><display><type>article</type><title>Industrial radiotracer application in flow rate measurement and flowmeter calibration using 99mTc and 198Au nanoparticles radioisotope</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Mohd Yunos, Mohd Amirul Syafiq ; Hussain, Siti Aslina ; Sipaun, Susan Maria</creator><creatorcontrib>Mohd Yunos, Mohd Amirul Syafiq ; Hussain, Siti Aslina ; Sipaun, Susan Maria</creatorcontrib><description>The flow rate or fluid velocity measurement is important to maintain fluid flow quality performance in the systems. This study focuses on determination of volumetric flow rate measurement and to calibrate the conventional flowmeter using industrial radiotracer approach in quadrilateral gas-liquid bubble column reactor. In this work, two different radioisotopes which emit γ-ray have been chosen as radioactive tracer which is 99mTc produced from 99Mo/99mTc radioisotope generator and 198Au nanoparticle form neutron activation at research nuclear reactor TRIGA Mark II. Both radioisotopes representing liquid and solid tracer purposely designed for tracing liquid flow. The peak to peak radiotracer method known as pulse velocity method was applied to determine the volumetric flow rate. The radiation signals were monitored using 4 unit NaI scintillation detectors located at 4 different points nearby the inlet and outlet of the quadrilateral bubble column reactor process stream. The water volume inside the bubble column reactor was fixed at 0.04 m3 and liquid flow rates in this reactor were specified on installed flowmeter at different reference value which is 4 lpm, 8 lpm, and 12 lpm, respectively. The experimental result shows very good linearity and repeatability by following the theoretical equations with less uncertainty in volumetric flow rate measurement. The obtained results also validated the effectiveness of the proposed method for the installed flowmeter calibration efficiency.
•The flow rate of liquid phase was measured using 99mTc and 198Au industrial radiotracer.•The peak to peak radiotracer method was applied to determine the volumetric flow rates.•Validation of the suitability of tracer physical form for radiotracer techniques.•Quadrilateral bubble column reactor model was used to simulate process stream.•Calibration of conventional flowmeter using radiotracer method was compared and validated.</description><identifier>ISSN: 0969-8043</identifier><identifier>EISSN: 1872-9800</identifier><identifier>DOI: 10.1016/j.apradiso.2018.10.008</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Bubble column ; Closed conduit ; Flowrate measurement ; Gold nanoparticle tracer ; Industrial radiotracer ; Scintillation detector</subject><ispartof>Applied radiation and isotopes, 2019-01, Vol.143, p.24-28</ispartof><rights>2018 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c1905-86d287531c3eb7a9ae74efd54bdd7dde3727d83bd466258537dc0e51cea125cd3</citedby><cites>FETCH-LOGICAL-c1905-86d287531c3eb7a9ae74efd54bdd7dde3727d83bd466258537dc0e51cea125cd3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0969804317314823$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Mohd Yunos, Mohd Amirul Syafiq</creatorcontrib><creatorcontrib>Hussain, Siti Aslina</creatorcontrib><creatorcontrib>Sipaun, Susan Maria</creatorcontrib><title>Industrial radiotracer application in flow rate measurement and flowmeter calibration using 99mTc and 198Au nanoparticles radioisotope</title><title>Applied radiation and isotopes</title><description>The flow rate or fluid velocity measurement is important to maintain fluid flow quality performance in the systems. This study focuses on determination of volumetric flow rate measurement and to calibrate the conventional flowmeter using industrial radiotracer approach in quadrilateral gas-liquid bubble column reactor. In this work, two different radioisotopes which emit γ-ray have been chosen as radioactive tracer which is 99mTc produced from 99Mo/99mTc radioisotope generator and 198Au nanoparticle form neutron activation at research nuclear reactor TRIGA Mark II. Both radioisotopes representing liquid and solid tracer purposely designed for tracing liquid flow. The peak to peak radiotracer method known as pulse velocity method was applied to determine the volumetric flow rate. The radiation signals were monitored using 4 unit NaI scintillation detectors located at 4 different points nearby the inlet and outlet of the quadrilateral bubble column reactor process stream. The water volume inside the bubble column reactor was fixed at 0.04 m3 and liquid flow rates in this reactor were specified on installed flowmeter at different reference value which is 4 lpm, 8 lpm, and 12 lpm, respectively. The experimental result shows very good linearity and repeatability by following the theoretical equations with less uncertainty in volumetric flow rate measurement. The obtained results also validated the effectiveness of the proposed method for the installed flowmeter calibration efficiency.
•The flow rate of liquid phase was measured using 99mTc and 198Au industrial radiotracer.•The peak to peak radiotracer method was applied to determine the volumetric flow rates.•Validation of the suitability of tracer physical form for radiotracer techniques.•Quadrilateral bubble column reactor model was used to simulate process stream.•Calibration of conventional flowmeter using radiotracer method was compared and validated.</description><subject>Bubble column</subject><subject>Closed conduit</subject><subject>Flowrate measurement</subject><subject>Gold nanoparticle tracer</subject><subject>Industrial radiotracer</subject><subject>Scintillation detector</subject><issn>0969-8043</issn><issn>1872-9800</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNqFUMlOwzAQtRBIlOUXUI5cUmxns29UFUulSlzK2ZraU-QqsYPtgPgBvpu0gTOnkd42M4-QG0bnjLL6bj-HPoCx0c85ZWIE55SKEzJjouG5FJSekhmVtcwFLYtzchHjnlJaCsln5HvlzBBTsNBmhxCfAmgMGfR9azUk611mXbZr_efIJ8w6hDgE7NClDJw5Mh2m0aKhtdswWYZo3VsmZbfRRxWTYjFkDpzvISSrW4zTuvHq5Hu8Imc7aCNe_85L8vr4sFk-5-uXp9Vysc41k7TKRW24aKqC6QK3DUjApsSdqcqtMY0xWDS8MaLYmrKueSWqojGaYsU0AuOVNsUluZ1y--DfB4xJdTZqbFtw6IeoOOO1ZIzLapTWk1QHH2PAneqD7SB8KUbVoXi1V3_Fq0PxB3wsfjTeT0YcH_mwGFTUFp1GYwPqpIy3_0X8ACRPkzM</recordid><startdate>201901</startdate><enddate>201901</enddate><creator>Mohd Yunos, Mohd Amirul Syafiq</creator><creator>Hussain, Siti Aslina</creator><creator>Sipaun, Susan Maria</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201901</creationdate><title>Industrial radiotracer application in flow rate measurement and flowmeter calibration using 99mTc and 198Au nanoparticles radioisotope</title><author>Mohd Yunos, Mohd Amirul Syafiq ; Hussain, Siti Aslina ; Sipaun, Susan Maria</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1905-86d287531c3eb7a9ae74efd54bdd7dde3727d83bd466258537dc0e51cea125cd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Bubble column</topic><topic>Closed conduit</topic><topic>Flowrate measurement</topic><topic>Gold nanoparticle tracer</topic><topic>Industrial radiotracer</topic><topic>Scintillation detector</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mohd Yunos, Mohd Amirul Syafiq</creatorcontrib><creatorcontrib>Hussain, Siti Aslina</creatorcontrib><creatorcontrib>Sipaun, Susan Maria</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Applied radiation and isotopes</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mohd Yunos, Mohd Amirul Syafiq</au><au>Hussain, Siti Aslina</au><au>Sipaun, Susan Maria</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Industrial radiotracer application in flow rate measurement and flowmeter calibration using 99mTc and 198Au nanoparticles radioisotope</atitle><jtitle>Applied radiation and isotopes</jtitle><date>2019-01</date><risdate>2019</risdate><volume>143</volume><spage>24</spage><epage>28</epage><pages>24-28</pages><issn>0969-8043</issn><eissn>1872-9800</eissn><abstract>The flow rate or fluid velocity measurement is important to maintain fluid flow quality performance in the systems. This study focuses on determination of volumetric flow rate measurement and to calibrate the conventional flowmeter using industrial radiotracer approach in quadrilateral gas-liquid bubble column reactor. In this work, two different radioisotopes which emit γ-ray have been chosen as radioactive tracer which is 99mTc produced from 99Mo/99mTc radioisotope generator and 198Au nanoparticle form neutron activation at research nuclear reactor TRIGA Mark II. Both radioisotopes representing liquid and solid tracer purposely designed for tracing liquid flow. The peak to peak radiotracer method known as pulse velocity method was applied to determine the volumetric flow rate. The radiation signals were monitored using 4 unit NaI scintillation detectors located at 4 different points nearby the inlet and outlet of the quadrilateral bubble column reactor process stream. The water volume inside the bubble column reactor was fixed at 0.04 m3 and liquid flow rates in this reactor were specified on installed flowmeter at different reference value which is 4 lpm, 8 lpm, and 12 lpm, respectively. The experimental result shows very good linearity and repeatability by following the theoretical equations with less uncertainty in volumetric flow rate measurement. The obtained results also validated the effectiveness of the proposed method for the installed flowmeter calibration efficiency.
•The flow rate of liquid phase was measured using 99mTc and 198Au industrial radiotracer.•The peak to peak radiotracer method was applied to determine the volumetric flow rates.•Validation of the suitability of tracer physical form for radiotracer techniques.•Quadrilateral bubble column reactor model was used to simulate process stream.•Calibration of conventional flowmeter using radiotracer method was compared and validated.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.apradiso.2018.10.008</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0969-8043 |
ispartof | Applied radiation and isotopes, 2019-01, Vol.143, p.24-28 |
issn | 0969-8043 1872-9800 |
language | eng |
recordid | cdi_proquest_miscellaneous_2126911295 |
source | Elsevier ScienceDirect Journals Complete |
subjects | Bubble column Closed conduit Flowrate measurement Gold nanoparticle tracer Industrial radiotracer Scintillation detector |
title | Industrial radiotracer application in flow rate measurement and flowmeter calibration using 99mTc and 198Au nanoparticles radioisotope |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T22%3A34%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Industrial%20radiotracer%20application%20in%20flow%20rate%20measurement%20and%20flowmeter%20calibration%20using%2099mTc%20and%20198Au%20nanoparticles%20radioisotope&rft.jtitle=Applied%20radiation%20and%20isotopes&rft.au=Mohd%20Yunos,%20Mohd%20Amirul%20Syafiq&rft.date=2019-01&rft.volume=143&rft.spage=24&rft.epage=28&rft.pages=24-28&rft.issn=0969-8043&rft.eissn=1872-9800&rft_id=info:doi/10.1016/j.apradiso.2018.10.008&rft_dat=%3Cproquest_cross%3E2126911295%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2126911295&rft_id=info:pmid/&rft_els_id=S0969804317314823&rfr_iscdi=true |