Primary cementless total knee arthroplasty with or without stem extension: a matched comparative study of ninety eight standard stems versus ninety eight long stems after more than ten years of follow-up

Introduction Using a cementless fixation for total knee arthroplasty (TKA) is controversial. We hypothesized that cementless tibial base plate with a monoblock long stem (MLS) would provide secure tibial alignment and stable fixation when bone conditions were considered as poor for a cementless fixa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International orthopaedics 2019-08, Vol.43 (8), p.1849-1857
Hauptverfasser: Prudhon, Jean-Louis, Verdier, Régis, Caton, Jacques H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Introduction Using a cementless fixation for total knee arthroplasty (TKA) is controversial. We hypothesized that cementless tibial base plate with a monoblock long stem (MLS) would provide secure tibial alignment and stable fixation when bone conditions were considered as poor for a cementless fixation. The purpose of this study was to compare the mean eight year survivorship of cementless standard keels (SK) vs cementless MLS. Material methods We report a matched series of 98 cases of SK and 98 cases of MLS in patients with poor bone conditions. The two cohorts were statistically compared. Revision for tibial loosening was used as the endpoint in the survivorship analysis. Results We recorded two cases of tibial loosening and three cases of bipolar loosening in the SK group (0% MLS vs 5% SK). No tibial loosening occurred in the MLS group (statistically significant). No tibial periprosthetic or intra-operative fractures occurred in either group. The survivorship at eight years of follow-up was 95.6% in the SS cohort vs 100% in the MLS cohort using revision for tibial loosening as the endpoint. Discussion This study was not randomized. Its strength was that it took into account the comparative midterm outcomes of a matched cohort of patients implanted with two types of cementless components in the same bone conditions. We did not record any tibial loosening in the MLS group. Using long stems has been criticized but we did not observe any adverse reactions and no intra-operative tibial fracture occurred. Conclusion MLS improves the alignment and fixation of cementless TKA. This is a safe solution when bone conditions are poor or modified by previous surgery.
ISSN:0341-2695
1432-5195
DOI:10.1007/s00264-018-4191-5