Optimized Workflow for Selecting Peptides for HDX-MS Data Analyses

Hydrogen deuterium exchange measured by mass spectrometry (HDX-MS) is a commonly used technique for studying the structural dynamics of proteins in solution. The first part of any bottom-up HDX-MS experiment is to identify the peptides generated from a digestion step. This requires manual inspection...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the American Society for Mass Spectrometry 2018-11, Vol.29 (11), p.2278-2281
Hauptverfasser: Sørensen, Lars, Salbo, Rune
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2281
container_issue 11
container_start_page 2278
container_title Journal of the American Society for Mass Spectrometry
container_volume 29
creator Sørensen, Lars
Salbo, Rune
description Hydrogen deuterium exchange measured by mass spectrometry (HDX-MS) is a commonly used technique for studying the structural dynamics of proteins in solution. The first part of any bottom-up HDX-MS experiment is to identify the peptides generated from a digestion step. This requires manual inspection of the identified peptides to determine their use for HDX-MS analysis, which is a time-consuming task. Throughout the literature, there have been different approaches for removing peptides that do not yield quantifiable HDX information. This includes using validity scores from the software used in the generation of the peptide map and that the peptide should be found in two out of three technical replicate experiments. Here, we analyze the previously available methods for filtering the identified peptides in regard to their ability to predict whether a peptide will provide quantifiable HDX-MS data or not. We also present a new score-based system relying on a combination of MS/MS parameters that offers an improved method for separating quantifiable peptides from the nonquantifiable. Using this score-based method reduces the number of peptide spectra that needs to be manually inspected and thereby the time spent curating HDX-MS data. Graphical Abstract ᅟ
doi_str_mv 10.1007/s13361-018-2056-1
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2098773190</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2097844894</sourcerecordid><originalsourceid>FETCH-LOGICAL-c372t-b96c6a752ccc58e107ba80bfce9725f60e6cd165043682128b6ef3bafdf7e6203</originalsourceid><addsrcrecordid>eNp1kE1P3DAQhi3Uiq_yA7igSL30YpixE9s58lE-JCqQtlW5WY4zRqHZzdbOqoJfj3cXqITEySPPM--MHsb2EQ4RQB8llFIhBzRcQKU4brBtNLrmiEJ-yjWUJQcJ1RbbSekBADXUepNtyVxhWcI2O7mZj920e6K2-D3EP6Ef_hVhiMWEevJjN7svbikTLaXV9-XZHf8xKc7c6IrjmesfE6Uv7HNwfaK9l3eX_Tr__vP0kl_fXFydHl9zL7UYeVMrr5yuhPe-MoSgG2egCZ5qLaqggJRvUVVQSmUECtMoCrJxoQ2alAC5y76tc-dx-LugNNpplzz1vZvRsEhWQG20llgv0a_v0IdhEfO9K0qbsjR1mSlcUz4OKUUKdh67qYuPFsEuBdu1YJsF26Vgi3nm4CV50UypfZt4NZoBsQZSbs3uKf5f_XHqM8J-g6k</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2097844894</pqid></control><display><type>article</type><title>Optimized Workflow for Selecting Peptides for HDX-MS Data Analyses</title><source>SpringerLink Journals - AutoHoldings</source><creator>Sørensen, Lars ; Salbo, Rune</creator><creatorcontrib>Sørensen, Lars ; Salbo, Rune</creatorcontrib><description>Hydrogen deuterium exchange measured by mass spectrometry (HDX-MS) is a commonly used technique for studying the structural dynamics of proteins in solution. The first part of any bottom-up HDX-MS experiment is to identify the peptides generated from a digestion step. This requires manual inspection of the identified peptides to determine their use for HDX-MS analysis, which is a time-consuming task. Throughout the literature, there have been different approaches for removing peptides that do not yield quantifiable HDX information. This includes using validity scores from the software used in the generation of the peptide map and that the peptide should be found in two out of three technical replicate experiments. Here, we analyze the previously available methods for filtering the identified peptides in regard to their ability to predict whether a peptide will provide quantifiable HDX-MS data or not. We also present a new score-based system relying on a combination of MS/MS parameters that offers an improved method for separating quantifiable peptides from the nonquantifiable. Using this score-based method reduces the number of peptide spectra that needs to be manually inspected and thereby the time spent curating HDX-MS data. Graphical Abstract ᅟ</description><identifier>ISSN: 1044-0305</identifier><identifier>EISSN: 1879-1123</identifier><identifier>DOI: 10.1007/s13361-018-2056-1</identifier><identifier>PMID: 30171440</identifier><language>eng</language><publisher>New York: Springer US</publisher><subject>Analytical Chemistry ; Application Note ; Bioinformatics ; Biotechnology ; Chemistry ; Chemistry and Materials Science ; Deuterium ; Dynamic structural analysis ; Filtration ; Identification methods ; Inspection ; Mass spectrometry ; Organic Chemistry ; Peptides ; Proteins ; Proteomics ; Workflow</subject><ispartof>Journal of the American Society for Mass Spectrometry, 2018-11, Vol.29 (11), p.2278-2281</ispartof><rights>American Society for Mass Spectrometry 2018</rights><rights>Journal of The American Society for Mass Spectrometry is a copyright of Springer, (2018). All Rights Reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c372t-b96c6a752ccc58e107ba80bfce9725f60e6cd165043682128b6ef3bafdf7e6203</citedby><cites>FETCH-LOGICAL-c372t-b96c6a752ccc58e107ba80bfce9725f60e6cd165043682128b6ef3bafdf7e6203</cites><orcidid>0000-0001-7653-4920</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s13361-018-2056-1$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s13361-018-2056-1$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,41488,42557,51319</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30171440$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sørensen, Lars</creatorcontrib><creatorcontrib>Salbo, Rune</creatorcontrib><title>Optimized Workflow for Selecting Peptides for HDX-MS Data Analyses</title><title>Journal of the American Society for Mass Spectrometry</title><addtitle>J. Am. Soc. Mass Spectrom</addtitle><addtitle>J Am Soc Mass Spectrom</addtitle><description>Hydrogen deuterium exchange measured by mass spectrometry (HDX-MS) is a commonly used technique for studying the structural dynamics of proteins in solution. The first part of any bottom-up HDX-MS experiment is to identify the peptides generated from a digestion step. This requires manual inspection of the identified peptides to determine their use for HDX-MS analysis, which is a time-consuming task. Throughout the literature, there have been different approaches for removing peptides that do not yield quantifiable HDX information. This includes using validity scores from the software used in the generation of the peptide map and that the peptide should be found in two out of three technical replicate experiments. Here, we analyze the previously available methods for filtering the identified peptides in regard to their ability to predict whether a peptide will provide quantifiable HDX-MS data or not. We also present a new score-based system relying on a combination of MS/MS parameters that offers an improved method for separating quantifiable peptides from the nonquantifiable. Using this score-based method reduces the number of peptide spectra that needs to be manually inspected and thereby the time spent curating HDX-MS data. Graphical Abstract ᅟ</description><subject>Analytical Chemistry</subject><subject>Application Note</subject><subject>Bioinformatics</subject><subject>Biotechnology</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><subject>Deuterium</subject><subject>Dynamic structural analysis</subject><subject>Filtration</subject><subject>Identification methods</subject><subject>Inspection</subject><subject>Mass spectrometry</subject><subject>Organic Chemistry</subject><subject>Peptides</subject><subject>Proteins</subject><subject>Proteomics</subject><subject>Workflow</subject><issn>1044-0305</issn><issn>1879-1123</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>8G5</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><sourceid>GUQSH</sourceid><sourceid>M2O</sourceid><recordid>eNp1kE1P3DAQhi3Uiq_yA7igSL30YpixE9s58lE-JCqQtlW5WY4zRqHZzdbOqoJfj3cXqITEySPPM--MHsb2EQ4RQB8llFIhBzRcQKU4brBtNLrmiEJ-yjWUJQcJ1RbbSekBADXUepNtyVxhWcI2O7mZj920e6K2-D3EP6Ef_hVhiMWEevJjN7svbikTLaXV9-XZHf8xKc7c6IrjmesfE6Uv7HNwfaK9l3eX_Tr__vP0kl_fXFydHl9zL7UYeVMrr5yuhPe-MoSgG2egCZ5qLaqggJRvUVVQSmUECtMoCrJxoQ2alAC5y76tc-dx-LugNNpplzz1vZvRsEhWQG20llgv0a_v0IdhEfO9K0qbsjR1mSlcUz4OKUUKdh67qYuPFsEuBdu1YJsF26Vgi3nm4CV50UypfZt4NZoBsQZSbs3uKf5f_XHqM8J-g6k</recordid><startdate>20181101</startdate><enddate>20181101</enddate><creator>Sørensen, Lars</creator><creator>Salbo, Rune</creator><general>Springer US</general><general>Springer Nature B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8FE</scope><scope>8FG</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>8G5</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>GUQSH</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>M2O</scope><scope>MBDVC</scope><scope>P5Z</scope><scope>P62</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-7653-4920</orcidid></search><sort><creationdate>20181101</creationdate><title>Optimized Workflow for Selecting Peptides for HDX-MS Data Analyses</title><author>Sørensen, Lars ; Salbo, Rune</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c372t-b96c6a752ccc58e107ba80bfce9725f60e6cd165043682128b6ef3bafdf7e6203</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Analytical Chemistry</topic><topic>Application Note</topic><topic>Bioinformatics</topic><topic>Biotechnology</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><topic>Deuterium</topic><topic>Dynamic structural analysis</topic><topic>Filtration</topic><topic>Identification methods</topic><topic>Inspection</topic><topic>Mass spectrometry</topic><topic>Organic Chemistry</topic><topic>Peptides</topic><topic>Proteins</topic><topic>Proteomics</topic><topic>Workflow</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sørensen, Lars</creatorcontrib><creatorcontrib>Salbo, Rune</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Research Library (Alumni Edition)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Research Library Prep</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Research Library</collection><collection>Research Library (Corporate)</collection><collection>Advanced Technologies &amp; Aerospace Database</collection><collection>ProQuest Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of the American Society for Mass Spectrometry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sørensen, Lars</au><au>Salbo, Rune</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Optimized Workflow for Selecting Peptides for HDX-MS Data Analyses</atitle><jtitle>Journal of the American Society for Mass Spectrometry</jtitle><stitle>J. Am. Soc. Mass Spectrom</stitle><addtitle>J Am Soc Mass Spectrom</addtitle><date>2018-11-01</date><risdate>2018</risdate><volume>29</volume><issue>11</issue><spage>2278</spage><epage>2281</epage><pages>2278-2281</pages><issn>1044-0305</issn><eissn>1879-1123</eissn><abstract>Hydrogen deuterium exchange measured by mass spectrometry (HDX-MS) is a commonly used technique for studying the structural dynamics of proteins in solution. The first part of any bottom-up HDX-MS experiment is to identify the peptides generated from a digestion step. This requires manual inspection of the identified peptides to determine their use for HDX-MS analysis, which is a time-consuming task. Throughout the literature, there have been different approaches for removing peptides that do not yield quantifiable HDX information. This includes using validity scores from the software used in the generation of the peptide map and that the peptide should be found in two out of three technical replicate experiments. Here, we analyze the previously available methods for filtering the identified peptides in regard to their ability to predict whether a peptide will provide quantifiable HDX-MS data or not. We also present a new score-based system relying on a combination of MS/MS parameters that offers an improved method for separating quantifiable peptides from the nonquantifiable. Using this score-based method reduces the number of peptide spectra that needs to be manually inspected and thereby the time spent curating HDX-MS data. Graphical Abstract ᅟ</abstract><cop>New York</cop><pub>Springer US</pub><pmid>30171440</pmid><doi>10.1007/s13361-018-2056-1</doi><tpages>4</tpages><orcidid>https://orcid.org/0000-0001-7653-4920</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1044-0305
ispartof Journal of the American Society for Mass Spectrometry, 2018-11, Vol.29 (11), p.2278-2281
issn 1044-0305
1879-1123
language eng
recordid cdi_proquest_miscellaneous_2098773190
source SpringerLink Journals - AutoHoldings
subjects Analytical Chemistry
Application Note
Bioinformatics
Biotechnology
Chemistry
Chemistry and Materials Science
Deuterium
Dynamic structural analysis
Filtration
Identification methods
Inspection
Mass spectrometry
Organic Chemistry
Peptides
Proteins
Proteomics
Workflow
title Optimized Workflow for Selecting Peptides for HDX-MS Data Analyses
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-30T22%3A41%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Optimized%20Workflow%20for%20Selecting%20Peptides%20for%20HDX-MS%20Data%20Analyses&rft.jtitle=Journal%20of%20the%20American%20Society%20for%20Mass%20Spectrometry&rft.au=S%C3%B8rensen,%20Lars&rft.date=2018-11-01&rft.volume=29&rft.issue=11&rft.spage=2278&rft.epage=2281&rft.pages=2278-2281&rft.issn=1044-0305&rft.eissn=1879-1123&rft_id=info:doi/10.1007/s13361-018-2056-1&rft_dat=%3Cproquest_cross%3E2097844894%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2097844894&rft_id=info:pmid/30171440&rfr_iscdi=true