Evaluation of the performance of three hand-held near-infrared spectrometer through investigation of total antioxidant capacity in gluten-free grains

The performance of three portable NIR spectrometers was compared by analysing the total antioxidant capacity (TAC) of different species of gluten-free grains. TAC is often used to evaluate the quality of foods and was determined using Folin-Ciocalteu measurements and used as reference data for estab...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2018-11, Vol.189, p.233-240
Hauptverfasser: Wiedemair, Verena, Huck, Christian W.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 240
container_issue
container_start_page 233
container_title Talanta (Oxford)
container_volume 189
creator Wiedemair, Verena
Huck, Christian W.
description The performance of three portable NIR spectrometers was compared by analysing the total antioxidant capacity (TAC) of different species of gluten-free grains. TAC is often used to evaluate the quality of foods and was determined using Folin-Ciocalteu measurements and used as reference data for establishing PLS-R models with NIR data. NIRS enables fast and non-invasive measurements. The microPhazir RX and the MicroNIR 2200 are broadly used in chemical and pharmaceutical industries, whereas SCiO is a pocket-sized, consumer-oriented spectrometer. The devices work in different regions of the NIR spectrum and their performances was compared using statistical parameters. 77 samples were measured and analysed using the software The Unscrambler X, as well as SCiO-Lab. All models established were cross- and test set validated. The multivariate data processing using The Unscrambler X yielded similar results as SCiO-Lab. The best model was established for non-milled samples measured with the MicroNIR 2200 and analysed using The Unscrambler X. [Display omitted] •Performance of pocket-sized NIR spectrometer is comparable to other hand-held devices.•Simplified multivariate data analyses yield similar results as sophisticated analyses.•Calculation of multivariate LOD and LOQ for hand-held NIR spectrometer.
doi_str_mv 10.1016/j.talanta.2018.06.056
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2085655520</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0039914018306647</els_id><sourcerecordid>2085655520</sourcerecordid><originalsourceid>FETCH-LOGICAL-c365t-2b3db68f881e6edfc4fbaa9e566e02506dde346770d8528d9db3e8a4b2d8d70c3</originalsourceid><addsrcrecordid>eNqFkc1u1DAUhS0EokPbRwB5ySbhOh47zgqhqvxIlbopa8uxb2Y8SuJgOyP6ILwvHs0AS1ZXsr57z_E5hLxlUDNg8sOhzmY0czZ1A0zVIGsQ8gXZMNXyiouWvyQbAN5VHdvCFXmT0gEAGg78NbniAEp2jG3Ir_ujGVeTfZhpGGjeI10wDiFOZrZ4foqIdG9mV-1xdHRGEys_D9FEdDQtaHMME2aMJzSsuz318xFT9rt_Z0MxS4tbH356Vya1ZjHW5-fC0t24Zpyr4aSzi8bP6Ya8GsyY8PYyr8n3z_dPd1-rh8cv3-4-PVSWS5Grpueul2pQiqFEN9jt0BvToZASoREgnUO-lW0LTolGuc71HJXZ9o1TrgXLr8n7890lhh9r8awnnyyOJVgMa9INKCGFEA0UVJxRG0NKEQe9RD-Z-KwZ6FMj-qAvjehTIxqkLo2UvXcXibWf0P3d-lNBAT6eASwfPXqMOlmPJXznY8lWu-D_I_Ebsq2kGg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2085655520</pqid></control><display><type>article</type><title>Evaluation of the performance of three hand-held near-infrared spectrometer through investigation of total antioxidant capacity in gluten-free grains</title><source>Elsevier ScienceDirect Journals</source><creator>Wiedemair, Verena ; Huck, Christian W.</creator><creatorcontrib>Wiedemair, Verena ; Huck, Christian W.</creatorcontrib><description>The performance of three portable NIR spectrometers was compared by analysing the total antioxidant capacity (TAC) of different species of gluten-free grains. TAC is often used to evaluate the quality of foods and was determined using Folin-Ciocalteu measurements and used as reference data for establishing PLS-R models with NIR data. NIRS enables fast and non-invasive measurements. The microPhazir RX and the MicroNIR 2200 are broadly used in chemical and pharmaceutical industries, whereas SCiO is a pocket-sized, consumer-oriented spectrometer. The devices work in different regions of the NIR spectrum and their performances was compared using statistical parameters. 77 samples were measured and analysed using the software The Unscrambler X, as well as SCiO-Lab. All models established were cross- and test set validated. The multivariate data processing using The Unscrambler X yielded similar results as SCiO-Lab. The best model was established for non-milled samples measured with the MicroNIR 2200 and analysed using The Unscrambler X. [Display omitted] •Performance of pocket-sized NIR spectrometer is comparable to other hand-held devices.•Simplified multivariate data analyses yield similar results as sophisticated analyses.•Calculation of multivariate LOD and LOQ for hand-held NIR spectrometer.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/j.talanta.2018.06.056</identifier><identifier>PMID: 30086911</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Miniaturisation ; NIRS ; Phazir, MicroNIR ; SCiO</subject><ispartof>Talanta (Oxford), 2018-11, Vol.189, p.233-240</ispartof><rights>2018 Elsevier B.V.</rights><rights>Copyright © 2018 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c365t-2b3db68f881e6edfc4fbaa9e566e02506dde346770d8528d9db3e8a4b2d8d70c3</citedby><cites>FETCH-LOGICAL-c365t-2b3db68f881e6edfc4fbaa9e566e02506dde346770d8528d9db3e8a4b2d8d70c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0039914018306647$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65534</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30086911$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Wiedemair, Verena</creatorcontrib><creatorcontrib>Huck, Christian W.</creatorcontrib><title>Evaluation of the performance of three hand-held near-infrared spectrometer through investigation of total antioxidant capacity in gluten-free grains</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>The performance of three portable NIR spectrometers was compared by analysing the total antioxidant capacity (TAC) of different species of gluten-free grains. TAC is often used to evaluate the quality of foods and was determined using Folin-Ciocalteu measurements and used as reference data for establishing PLS-R models with NIR data. NIRS enables fast and non-invasive measurements. The microPhazir RX and the MicroNIR 2200 are broadly used in chemical and pharmaceutical industries, whereas SCiO is a pocket-sized, consumer-oriented spectrometer. The devices work in different regions of the NIR spectrum and their performances was compared using statistical parameters. 77 samples were measured and analysed using the software The Unscrambler X, as well as SCiO-Lab. All models established were cross- and test set validated. The multivariate data processing using The Unscrambler X yielded similar results as SCiO-Lab. The best model was established for non-milled samples measured with the MicroNIR 2200 and analysed using The Unscrambler X. [Display omitted] •Performance of pocket-sized NIR spectrometer is comparable to other hand-held devices.•Simplified multivariate data analyses yield similar results as sophisticated analyses.•Calculation of multivariate LOD and LOQ for hand-held NIR spectrometer.</description><subject>Miniaturisation</subject><subject>NIRS</subject><subject>Phazir, MicroNIR</subject><subject>SCiO</subject><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqFkc1u1DAUhS0EokPbRwB5ySbhOh47zgqhqvxIlbopa8uxb2Y8SuJgOyP6ILwvHs0AS1ZXsr57z_E5hLxlUDNg8sOhzmY0czZ1A0zVIGsQ8gXZMNXyiouWvyQbAN5VHdvCFXmT0gEAGg78NbniAEp2jG3Ir_ujGVeTfZhpGGjeI10wDiFOZrZ4foqIdG9mV-1xdHRGEys_D9FEdDQtaHMME2aMJzSsuz318xFT9rt_Z0MxS4tbH356Vya1ZjHW5-fC0t24Zpyr4aSzi8bP6Ya8GsyY8PYyr8n3z_dPd1-rh8cv3-4-PVSWS5Grpueul2pQiqFEN9jt0BvToZASoREgnUO-lW0LTolGuc71HJXZ9o1TrgXLr8n7890lhh9r8awnnyyOJVgMa9INKCGFEA0UVJxRG0NKEQe9RD-Z-KwZ6FMj-qAvjehTIxqkLo2UvXcXibWf0P3d-lNBAT6eASwfPXqMOlmPJXznY8lWu-D_I_Ebsq2kGg</recordid><startdate>20181101</startdate><enddate>20181101</enddate><creator>Wiedemair, Verena</creator><creator>Huck, Christian W.</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20181101</creationdate><title>Evaluation of the performance of three hand-held near-infrared spectrometer through investigation of total antioxidant capacity in gluten-free grains</title><author>Wiedemair, Verena ; Huck, Christian W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c365t-2b3db68f881e6edfc4fbaa9e566e02506dde346770d8528d9db3e8a4b2d8d70c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Miniaturisation</topic><topic>NIRS</topic><topic>Phazir, MicroNIR</topic><topic>SCiO</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wiedemair, Verena</creatorcontrib><creatorcontrib>Huck, Christian W.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wiedemair, Verena</au><au>Huck, Christian W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of the performance of three hand-held near-infrared spectrometer through investigation of total antioxidant capacity in gluten-free grains</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>2018-11-01</date><risdate>2018</risdate><volume>189</volume><spage>233</spage><epage>240</epage><pages>233-240</pages><issn>0039-9140</issn><eissn>1873-3573</eissn><abstract>The performance of three portable NIR spectrometers was compared by analysing the total antioxidant capacity (TAC) of different species of gluten-free grains. TAC is often used to evaluate the quality of foods and was determined using Folin-Ciocalteu measurements and used as reference data for establishing PLS-R models with NIR data. NIRS enables fast and non-invasive measurements. The microPhazir RX and the MicroNIR 2200 are broadly used in chemical and pharmaceutical industries, whereas SCiO is a pocket-sized, consumer-oriented spectrometer. The devices work in different regions of the NIR spectrum and their performances was compared using statistical parameters. 77 samples were measured and analysed using the software The Unscrambler X, as well as SCiO-Lab. All models established were cross- and test set validated. The multivariate data processing using The Unscrambler X yielded similar results as SCiO-Lab. The best model was established for non-milled samples measured with the MicroNIR 2200 and analysed using The Unscrambler X. [Display omitted] •Performance of pocket-sized NIR spectrometer is comparable to other hand-held devices.•Simplified multivariate data analyses yield similar results as sophisticated analyses.•Calculation of multivariate LOD and LOQ for hand-held NIR spectrometer.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>30086911</pmid><doi>10.1016/j.talanta.2018.06.056</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 2018-11, Vol.189, p.233-240
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_2085655520
source Elsevier ScienceDirect Journals
subjects Miniaturisation
NIRS
Phazir, MicroNIR
SCiO
title Evaluation of the performance of three hand-held near-infrared spectrometer through investigation of total antioxidant capacity in gluten-free grains
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-13T15%3A49%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20the%20performance%20of%20three%20hand-held%20near-infrared%20spectrometer%20through%20investigation%20of%20total%20antioxidant%20capacity%20in%20gluten-free%20grains&rft.jtitle=Talanta%20(Oxford)&rft.au=Wiedemair,%20Verena&rft.date=2018-11-01&rft.volume=189&rft.spage=233&rft.epage=240&rft.pages=233-240&rft.issn=0039-9140&rft.eissn=1873-3573&rft_id=info:doi/10.1016/j.talanta.2018.06.056&rft_dat=%3Cproquest_cross%3E2085655520%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2085655520&rft_id=info:pmid/30086911&rft_els_id=S0039914018306647&rfr_iscdi=true