First point-spread function and x-ray phase-contrast imaging results with an 88-mm diameter single crystal
In this study, we report initial demonstrations of the use of single crystals in indirect x-ray imaging with a benchtop implementation of propagation-based x-ray phase-contrast imaging. Based on single Gaussian peak fits to the x-ray images, we observed a four times smaller system point-spread funct...
Gespeichert in:
Veröffentlicht in: | Review of scientific instruments 2018-07, Vol.89 (7), p.073704-073704 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 073704 |
---|---|
container_issue | 7 |
container_start_page | 073704 |
container_title | Review of scientific instruments |
container_volume | 89 |
creator | Lumpkin, Alex H. Garson, Alfred B. Anastasio, Mark A. |
description | In this study, we report initial demonstrations of the use of single crystals in indirect x-ray imaging with a benchtop implementation of propagation-based x-ray phase-contrast imaging. Based on single Gaussian peak fits to the x-ray images, we observed a four times smaller system point-spread function (PSF) with the 50-µm thick single crystal scintillators than with the reference polycrystalline phosphor/scintillator. Fiber-optic plate depth-of-focus and Al reflective-coating aspects are also elucidated. Guided by the results from the 25-mm diameter crystal samples, we report additionally the first results with a unique 88-mm diameter single crystal bonded to a fiber optic plate and coupled to the large format CCD. Both PSF and x-ray phase-contrast imaging data are quantified and presented. |
doi_str_mv | 10.1063/1.5027499 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2082093139</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2087553629</sourcerecordid><originalsourceid>FETCH-LOGICAL-c410t-862adb4ef3e1b760da41c5ee26a5d892306ca31f6415570477b4e644552813053</originalsourceid><addsrcrecordid>eNp90U9rFDEYBvAgil2rB7-ABL1UITX_J3OU0qpQ8KLnkM28080ykxmTTHW_vRl2raBgLrn8ePLmfRB6yeglo1q8Z5eK8ka27SO0YdS0pNFcPEYbSoUkupHmDD3LeU_rUYw9RWeCUm2YbDdofxNSLnieQiwkzwlch_sl-hKmiF3s8E-S3AHPO5eB-CmW5CoPo7sL8Q4nyMtQMv4Ryq5qbAwZR9wFN0KBhHM1A2CfDrm44Tl60rshw4vTfY6-3Vx_vfpEbr98_Hz14ZZ4yWghRnPXbSX0Ati20bRzknkFwLVTnWm5oNo7wXotmVINlU1TsZZSKW6YoEqco9fH3CmXYLMPBfyujh7BF8ukMErwii6OaE7T9wVysWPIHobBRZiWbDk1nLaCibbSN3_R_bSkWL-wqkYpofmq3h6VT1POCXo7p7qmdLCM2rUly-yppWpfnRKX7Qjdg_xdSwXvjmCd3q1dPJj7Kf1JsnPX_w__-_Qv8dKmeQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2087553629</pqid></control><display><type>article</type><title>First point-spread function and x-ray phase-contrast imaging results with an 88-mm diameter single crystal</title><source>AIP Journals Complete</source><source>Alma/SFX Local Collection</source><creator>Lumpkin, Alex H. ; Garson, Alfred B. ; Anastasio, Mark A.</creator><creatorcontrib>Lumpkin, Alex H. ; Garson, Alfred B. ; Anastasio, Mark A. ; Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)</creatorcontrib><description>In this study, we report initial demonstrations of the use of single crystals in indirect x-ray imaging with a benchtop implementation of propagation-based x-ray phase-contrast imaging. Based on single Gaussian peak fits to the x-ray images, we observed a four times smaller system point-spread function (PSF) with the 50-µm thick single crystal scintillators than with the reference polycrystalline phosphor/scintillator. Fiber-optic plate depth-of-focus and Al reflective-coating aspects are also elucidated. Guided by the results from the 25-mm diameter crystal samples, we report additionally the first results with a unique 88-mm diameter single crystal bonded to a fiber optic plate and coupled to the large format CCD. Both PSF and x-ray phase-contrast imaging data are quantified and presented.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.5027499</identifier><identifier>PMID: 30068149</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>United States: American Institute of Physics</publisher><subject>Fiber optics ; Image contrast ; INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY ; Large format ; Optical fibers ; Point spread functions ; PSF ; Scientific apparatus & instruments ; Scintillation counters ; single crystal scintillator ; Single crystals ; x-ray phase-contrast imaging ; x-rays</subject><ispartof>Review of scientific instruments, 2018-07, Vol.89 (7), p.073704-073704</ispartof><rights>Author(s)</rights><rights>2018 Author(s). Published by AIP Publishing.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c410t-862adb4ef3e1b760da41c5ee26a5d892306ca31f6415570477b4e644552813053</citedby><cites>FETCH-LOGICAL-c410t-862adb4ef3e1b760da41c5ee26a5d892306ca31f6415570477b4e644552813053</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.5027499$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>230,314,780,784,794,885,4512,27924,27925,76384</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30068149$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://www.osti.gov/servlets/purl/1438532$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Lumpkin, Alex H.</creatorcontrib><creatorcontrib>Garson, Alfred B.</creatorcontrib><creatorcontrib>Anastasio, Mark A.</creatorcontrib><creatorcontrib>Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)</creatorcontrib><title>First point-spread function and x-ray phase-contrast imaging results with an 88-mm diameter single crystal</title><title>Review of scientific instruments</title><addtitle>Rev Sci Instrum</addtitle><description>In this study, we report initial demonstrations of the use of single crystals in indirect x-ray imaging with a benchtop implementation of propagation-based x-ray phase-contrast imaging. Based on single Gaussian peak fits to the x-ray images, we observed a four times smaller system point-spread function (PSF) with the 50-µm thick single crystal scintillators than with the reference polycrystalline phosphor/scintillator. Fiber-optic plate depth-of-focus and Al reflective-coating aspects are also elucidated. Guided by the results from the 25-mm diameter crystal samples, we report additionally the first results with a unique 88-mm diameter single crystal bonded to a fiber optic plate and coupled to the large format CCD. Both PSF and x-ray phase-contrast imaging data are quantified and presented.</description><subject>Fiber optics</subject><subject>Image contrast</subject><subject>INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY</subject><subject>Large format</subject><subject>Optical fibers</subject><subject>Point spread functions</subject><subject>PSF</subject><subject>Scientific apparatus & instruments</subject><subject>Scintillation counters</subject><subject>single crystal scintillator</subject><subject>Single crystals</subject><subject>x-ray phase-contrast imaging</subject><subject>x-rays</subject><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp90U9rFDEYBvAgil2rB7-ABL1UITX_J3OU0qpQ8KLnkM28080ykxmTTHW_vRl2raBgLrn8ePLmfRB6yeglo1q8Z5eK8ka27SO0YdS0pNFcPEYbSoUkupHmDD3LeU_rUYw9RWeCUm2YbDdofxNSLnieQiwkzwlch_sl-hKmiF3s8E-S3AHPO5eB-CmW5CoPo7sL8Q4nyMtQMv4Ryq5qbAwZR9wFN0KBhHM1A2CfDrm44Tl60rshw4vTfY6-3Vx_vfpEbr98_Hz14ZZ4yWghRnPXbSX0Ati20bRzknkFwLVTnWm5oNo7wXotmVINlU1TsZZSKW6YoEqco9fH3CmXYLMPBfyujh7BF8ukMErwii6OaE7T9wVysWPIHobBRZiWbDk1nLaCibbSN3_R_bSkWL-wqkYpofmq3h6VT1POCXo7p7qmdLCM2rUly-yppWpfnRKX7Qjdg_xdSwXvjmCd3q1dPJj7Kf1JsnPX_w__-_Qv8dKmeQ</recordid><startdate>201807</startdate><enddate>201807</enddate><creator>Lumpkin, Alex H.</creator><creator>Garson, Alfred B.</creator><creator>Anastasio, Mark A.</creator><general>American Institute of Physics</general><general>American Institute of Physics (AIP)</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><scope>7X8</scope><scope>OIOZB</scope><scope>OTOTI</scope></search><sort><creationdate>201807</creationdate><title>First point-spread function and x-ray phase-contrast imaging results with an 88-mm diameter single crystal</title><author>Lumpkin, Alex H. ; Garson, Alfred B. ; Anastasio, Mark A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c410t-862adb4ef3e1b760da41c5ee26a5d892306ca31f6415570477b4e644552813053</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Fiber optics</topic><topic>Image contrast</topic><topic>INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY</topic><topic>Large format</topic><topic>Optical fibers</topic><topic>Point spread functions</topic><topic>PSF</topic><topic>Scientific apparatus & instruments</topic><topic>Scintillation counters</topic><topic>single crystal scintillator</topic><topic>Single crystals</topic><topic>x-ray phase-contrast imaging</topic><topic>x-rays</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lumpkin, Alex H.</creatorcontrib><creatorcontrib>Garson, Alfred B.</creatorcontrib><creatorcontrib>Anastasio, Mark A.</creatorcontrib><creatorcontrib>Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><collection>OSTI.GOV - Hybrid</collection><collection>OSTI.GOV</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lumpkin, Alex H.</au><au>Garson, Alfred B.</au><au>Anastasio, Mark A.</au><aucorp>Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>First point-spread function and x-ray phase-contrast imaging results with an 88-mm diameter single crystal</atitle><jtitle>Review of scientific instruments</jtitle><addtitle>Rev Sci Instrum</addtitle><date>2018-07</date><risdate>2018</risdate><volume>89</volume><issue>7</issue><spage>073704</spage><epage>073704</epage><pages>073704-073704</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>In this study, we report initial demonstrations of the use of single crystals in indirect x-ray imaging with a benchtop implementation of propagation-based x-ray phase-contrast imaging. Based on single Gaussian peak fits to the x-ray images, we observed a four times smaller system point-spread function (PSF) with the 50-µm thick single crystal scintillators than with the reference polycrystalline phosphor/scintillator. Fiber-optic plate depth-of-focus and Al reflective-coating aspects are also elucidated. Guided by the results from the 25-mm diameter crystal samples, we report additionally the first results with a unique 88-mm diameter single crystal bonded to a fiber optic plate and coupled to the large format CCD. Both PSF and x-ray phase-contrast imaging data are quantified and presented.</abstract><cop>United States</cop><pub>American Institute of Physics</pub><pmid>30068149</pmid><doi>10.1063/1.5027499</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0034-6748 |
ispartof | Review of scientific instruments, 2018-07, Vol.89 (7), p.073704-073704 |
issn | 0034-6748 1089-7623 |
language | eng |
recordid | cdi_proquest_miscellaneous_2082093139 |
source | AIP Journals Complete; Alma/SFX Local Collection |
subjects | Fiber optics Image contrast INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY Large format Optical fibers Point spread functions PSF Scientific apparatus & instruments Scintillation counters single crystal scintillator Single crystals x-ray phase-contrast imaging x-rays |
title | First point-spread function and x-ray phase-contrast imaging results with an 88-mm diameter single crystal |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T04%3A45%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=First%20point-spread%20function%20and%20x-ray%20phase-contrast%20imaging%20results%20with%20an%2088-mm%20diameter%20single%20crystal&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Lumpkin,%20Alex%20H.&rft.aucorp=Fermi%20National%20Accelerator%20Lab.%20(FNAL),%20Batavia,%20IL%20(United%20States)&rft.date=2018-07&rft.volume=89&rft.issue=7&rft.spage=073704&rft.epage=073704&rft.pages=073704-073704&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.5027499&rft_dat=%3Cproquest_cross%3E2087553629%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2087553629&rft_id=info:pmid/30068149&rfr_iscdi=true |