3D Molecular ToF-SIMS Imaging of Artificial Lipid Membranes Using a Discriminant Analysis-Based Algorithm

Artificial lipid membranes play a growing role in technical applications such as biosensors in pharmacological research and as model systems in the investigation of biological lipid films. In the standard procedure for displaying the distribution of membrane components, fluorescence microscopy, the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Langmuir 2018-07, Vol.34 (30), p.8750-8757
Hauptverfasser: Kassenböhmer, Rainer, Heeger, Marcel, Dwivedi, Mridula, Körsgen, Martin, Tyler, Bonnie J, Galla, Hans-Joachim, Arlinghaus, Heinrich F
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 8757
container_issue 30
container_start_page 8750
container_title Langmuir
container_volume 34
creator Kassenböhmer, Rainer
Heeger, Marcel
Dwivedi, Mridula
Körsgen, Martin
Tyler, Bonnie J
Galla, Hans-Joachim
Arlinghaus, Heinrich F
description Artificial lipid membranes play a growing role in technical applications such as biosensors in pharmacological research and as model systems in the investigation of biological lipid films. In the standard procedure for displaying the distribution of membrane components, fluorescence microscopy, the fluorophores used can influence the distribution of the components and usually not all substances can be displayed at the same time. The discriminant analysis-based algorithm used in combination with scanning time-of-flight secondary ion mass spectrometry (ToF-SIMS) enables marker-free, quantitative, simultaneous recording of all membrane components. These data are used for reconstruction of distribution patterns. In the model system used for this survey, a tear fluid lipid layer, the distribution patterns of all lipids correlate well in calculated ToF-SIMS images and epi-fluorescence microscopic images. All epi-fluorescence microscopically viewable structures are visible when using both positive and negative secondary ions and can be reproduced with high lateral resolution in the submicrometer range despite the very low signal intensity and a very low signal-to-noise ratio. In addition, three-dimensional images can be obtained with a subnanometer depth resolution. Furthermore, structures and the distribution of substances that cannot be made visible by epi-fluorescence microscopy can be displayed. This enables new insights that cannot be gained by epi-fluorescence microscopy alone.
doi_str_mv 10.1021/acs.langmuir.8b01253
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2063710468</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2063710468</sourcerecordid><originalsourceid>FETCH-LOGICAL-a385t-a191db3e99aa8201cc6cb073828a03743ed8318e66bdd3043d97ff712945f4c03</originalsourceid><addsrcrecordid>eNp9kLtOAzEQRS0EgvD4A4Rc0mwY2_uwy5DwiJSIIqFezXq9wdE-gr1b5O9xlEBJNc25d2YOIfcMxgw4e0LtxzW2m2awbiwLYDwRZ2TEEg5RInl2TkaQxSLK4lRckWvvtwCgRKwuyRVXKlUg1IhYMaPLrjZ6qNHRdfcarebLFZ03uLHthnYVnbjeVlZbrOnC7mxJl6YpHLbG009_YJDOrNfONrbFtqeTFuu9tz56Rm9KOqk3nbP9V3NLLiqsvbk7zRvy-fqynr5Hi4-3-XSyiFDIpI-QKVYWwiiFKDkwrVNdQCYklwgiPGRKKZg0aVqUpYBYlCqrqoxxFSdVrEHckMdj785134Pxfd6E80wdXJlu8DmHVGQM4lQGND6i2nXeO1Plu_AGun3OID9IzoPk_FdyfpIcYg-nDUPRmPIv9Gs1AHAEDvFtN7igxP_f-QObfItS</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2063710468</pqid></control><display><type>article</type><title>3D Molecular ToF-SIMS Imaging of Artificial Lipid Membranes Using a Discriminant Analysis-Based Algorithm</title><source>MEDLINE</source><source>American Chemical Society Journals</source><creator>Kassenböhmer, Rainer ; Heeger, Marcel ; Dwivedi, Mridula ; Körsgen, Martin ; Tyler, Bonnie J ; Galla, Hans-Joachim ; Arlinghaus, Heinrich F</creator><creatorcontrib>Kassenböhmer, Rainer ; Heeger, Marcel ; Dwivedi, Mridula ; Körsgen, Martin ; Tyler, Bonnie J ; Galla, Hans-Joachim ; Arlinghaus, Heinrich F</creatorcontrib><description>Artificial lipid membranes play a growing role in technical applications such as biosensors in pharmacological research and as model systems in the investigation of biological lipid films. In the standard procedure for displaying the distribution of membrane components, fluorescence microscopy, the fluorophores used can influence the distribution of the components and usually not all substances can be displayed at the same time. The discriminant analysis-based algorithm used in combination with scanning time-of-flight secondary ion mass spectrometry (ToF-SIMS) enables marker-free, quantitative, simultaneous recording of all membrane components. These data are used for reconstruction of distribution patterns. In the model system used for this survey, a tear fluid lipid layer, the distribution patterns of all lipids correlate well in calculated ToF-SIMS images and epi-fluorescence microscopic images. All epi-fluorescence microscopically viewable structures are visible when using both positive and negative secondary ions and can be reproduced with high lateral resolution in the submicrometer range despite the very low signal intensity and a very low signal-to-noise ratio. In addition, three-dimensional images can be obtained with a subnanometer depth resolution. Furthermore, structures and the distribution of substances that cannot be made visible by epi-fluorescence microscopy can be displayed. This enables new insights that cannot be gained by epi-fluorescence microscopy alone.</description><identifier>ISSN: 0743-7463</identifier><identifier>EISSN: 1520-5827</identifier><identifier>DOI: 10.1021/acs.langmuir.8b01253</identifier><identifier>PMID: 29969039</identifier><language>eng</language><publisher>United States: American Chemical Society</publisher><subject>Algorithms ; Discriminant Analysis ; Imaging, Three-Dimensional - methods ; Lipids - chemistry ; Membranes, Artificial ; Molecular Imaging - methods ; Spectrometry, Mass, Secondary Ion</subject><ispartof>Langmuir, 2018-07, Vol.34 (30), p.8750-8757</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a385t-a191db3e99aa8201cc6cb073828a03743ed8318e66bdd3043d97ff712945f4c03</citedby><cites>FETCH-LOGICAL-a385t-a191db3e99aa8201cc6cb073828a03743ed8318e66bdd3043d97ff712945f4c03</cites><orcidid>0000-0002-0349-0346 ; 0000-0003-1018-052X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://pubs.acs.org/doi/pdf/10.1021/acs.langmuir.8b01253$$EPDF$$P50$$Gacs$$H</linktopdf><linktohtml>$$Uhttps://pubs.acs.org/doi/10.1021/acs.langmuir.8b01253$$EHTML$$P50$$Gacs$$H</linktohtml><link.rule.ids>314,780,784,2765,27076,27924,27925,56738,56788</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29969039$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kassenböhmer, Rainer</creatorcontrib><creatorcontrib>Heeger, Marcel</creatorcontrib><creatorcontrib>Dwivedi, Mridula</creatorcontrib><creatorcontrib>Körsgen, Martin</creatorcontrib><creatorcontrib>Tyler, Bonnie J</creatorcontrib><creatorcontrib>Galla, Hans-Joachim</creatorcontrib><creatorcontrib>Arlinghaus, Heinrich F</creatorcontrib><title>3D Molecular ToF-SIMS Imaging of Artificial Lipid Membranes Using a Discriminant Analysis-Based Algorithm</title><title>Langmuir</title><addtitle>Langmuir</addtitle><description>Artificial lipid membranes play a growing role in technical applications such as biosensors in pharmacological research and as model systems in the investigation of biological lipid films. In the standard procedure for displaying the distribution of membrane components, fluorescence microscopy, the fluorophores used can influence the distribution of the components and usually not all substances can be displayed at the same time. The discriminant analysis-based algorithm used in combination with scanning time-of-flight secondary ion mass spectrometry (ToF-SIMS) enables marker-free, quantitative, simultaneous recording of all membrane components. These data are used for reconstruction of distribution patterns. In the model system used for this survey, a tear fluid lipid layer, the distribution patterns of all lipids correlate well in calculated ToF-SIMS images and epi-fluorescence microscopic images. All epi-fluorescence microscopically viewable structures are visible when using both positive and negative secondary ions and can be reproduced with high lateral resolution in the submicrometer range despite the very low signal intensity and a very low signal-to-noise ratio. In addition, three-dimensional images can be obtained with a subnanometer depth resolution. Furthermore, structures and the distribution of substances that cannot be made visible by epi-fluorescence microscopy can be displayed. This enables new insights that cannot be gained by epi-fluorescence microscopy alone.</description><subject>Algorithms</subject><subject>Discriminant Analysis</subject><subject>Imaging, Three-Dimensional - methods</subject><subject>Lipids - chemistry</subject><subject>Membranes, Artificial</subject><subject>Molecular Imaging - methods</subject><subject>Spectrometry, Mass, Secondary Ion</subject><issn>0743-7463</issn><issn>1520-5827</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kLtOAzEQRS0EgvD4A4Rc0mwY2_uwy5DwiJSIIqFezXq9wdE-gr1b5O9xlEBJNc25d2YOIfcMxgw4e0LtxzW2m2awbiwLYDwRZ2TEEg5RInl2TkaQxSLK4lRckWvvtwCgRKwuyRVXKlUg1IhYMaPLrjZ6qNHRdfcarebLFZ03uLHthnYVnbjeVlZbrOnC7mxJl6YpHLbG009_YJDOrNfONrbFtqeTFuu9tz56Rm9KOqk3nbP9V3NLLiqsvbk7zRvy-fqynr5Hi4-3-XSyiFDIpI-QKVYWwiiFKDkwrVNdQCYklwgiPGRKKZg0aVqUpYBYlCqrqoxxFSdVrEHckMdj785134Pxfd6E80wdXJlu8DmHVGQM4lQGND6i2nXeO1Plu_AGun3OID9IzoPk_FdyfpIcYg-nDUPRmPIv9Gs1AHAEDvFtN7igxP_f-QObfItS</recordid><startdate>20180731</startdate><enddate>20180731</enddate><creator>Kassenböhmer, Rainer</creator><creator>Heeger, Marcel</creator><creator>Dwivedi, Mridula</creator><creator>Körsgen, Martin</creator><creator>Tyler, Bonnie J</creator><creator>Galla, Hans-Joachim</creator><creator>Arlinghaus, Heinrich F</creator><general>American Chemical Society</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-0349-0346</orcidid><orcidid>https://orcid.org/0000-0003-1018-052X</orcidid></search><sort><creationdate>20180731</creationdate><title>3D Molecular ToF-SIMS Imaging of Artificial Lipid Membranes Using a Discriminant Analysis-Based Algorithm</title><author>Kassenböhmer, Rainer ; Heeger, Marcel ; Dwivedi, Mridula ; Körsgen, Martin ; Tyler, Bonnie J ; Galla, Hans-Joachim ; Arlinghaus, Heinrich F</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a385t-a191db3e99aa8201cc6cb073828a03743ed8318e66bdd3043d97ff712945f4c03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Algorithms</topic><topic>Discriminant Analysis</topic><topic>Imaging, Three-Dimensional - methods</topic><topic>Lipids - chemistry</topic><topic>Membranes, Artificial</topic><topic>Molecular Imaging - methods</topic><topic>Spectrometry, Mass, Secondary Ion</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kassenböhmer, Rainer</creatorcontrib><creatorcontrib>Heeger, Marcel</creatorcontrib><creatorcontrib>Dwivedi, Mridula</creatorcontrib><creatorcontrib>Körsgen, Martin</creatorcontrib><creatorcontrib>Tyler, Bonnie J</creatorcontrib><creatorcontrib>Galla, Hans-Joachim</creatorcontrib><creatorcontrib>Arlinghaus, Heinrich F</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Langmuir</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kassenböhmer, Rainer</au><au>Heeger, Marcel</au><au>Dwivedi, Mridula</au><au>Körsgen, Martin</au><au>Tyler, Bonnie J</au><au>Galla, Hans-Joachim</au><au>Arlinghaus, Heinrich F</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>3D Molecular ToF-SIMS Imaging of Artificial Lipid Membranes Using a Discriminant Analysis-Based Algorithm</atitle><jtitle>Langmuir</jtitle><addtitle>Langmuir</addtitle><date>2018-07-31</date><risdate>2018</risdate><volume>34</volume><issue>30</issue><spage>8750</spage><epage>8757</epage><pages>8750-8757</pages><issn>0743-7463</issn><eissn>1520-5827</eissn><abstract>Artificial lipid membranes play a growing role in technical applications such as biosensors in pharmacological research and as model systems in the investigation of biological lipid films. In the standard procedure for displaying the distribution of membrane components, fluorescence microscopy, the fluorophores used can influence the distribution of the components and usually not all substances can be displayed at the same time. The discriminant analysis-based algorithm used in combination with scanning time-of-flight secondary ion mass spectrometry (ToF-SIMS) enables marker-free, quantitative, simultaneous recording of all membrane components. These data are used for reconstruction of distribution patterns. In the model system used for this survey, a tear fluid lipid layer, the distribution patterns of all lipids correlate well in calculated ToF-SIMS images and epi-fluorescence microscopic images. All epi-fluorescence microscopically viewable structures are visible when using both positive and negative secondary ions and can be reproduced with high lateral resolution in the submicrometer range despite the very low signal intensity and a very low signal-to-noise ratio. In addition, three-dimensional images can be obtained with a subnanometer depth resolution. Furthermore, structures and the distribution of substances that cannot be made visible by epi-fluorescence microscopy can be displayed. This enables new insights that cannot be gained by epi-fluorescence microscopy alone.</abstract><cop>United States</cop><pub>American Chemical Society</pub><pmid>29969039</pmid><doi>10.1021/acs.langmuir.8b01253</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0002-0349-0346</orcidid><orcidid>https://orcid.org/0000-0003-1018-052X</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0743-7463
ispartof Langmuir, 2018-07, Vol.34 (30), p.8750-8757
issn 0743-7463
1520-5827
language eng
recordid cdi_proquest_miscellaneous_2063710468
source MEDLINE; American Chemical Society Journals
subjects Algorithms
Discriminant Analysis
Imaging, Three-Dimensional - methods
Lipids - chemistry
Membranes, Artificial
Molecular Imaging - methods
Spectrometry, Mass, Secondary Ion
title 3D Molecular ToF-SIMS Imaging of Artificial Lipid Membranes Using a Discriminant Analysis-Based Algorithm
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T14%3A29%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=3D%20Molecular%20ToF-SIMS%20Imaging%20of%20Artificial%20Lipid%20Membranes%20Using%20a%20Discriminant%20Analysis-Based%20Algorithm&rft.jtitle=Langmuir&rft.au=Kassenbo%CC%88hmer,%20Rainer&rft.date=2018-07-31&rft.volume=34&rft.issue=30&rft.spage=8750&rft.epage=8757&rft.pages=8750-8757&rft.issn=0743-7463&rft.eissn=1520-5827&rft_id=info:doi/10.1021/acs.langmuir.8b01253&rft_dat=%3Cproquest_cross%3E2063710468%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2063710468&rft_id=info:pmid/29969039&rfr_iscdi=true