Application of electrical imaging to leachate plume evolution studies under in-situ and model conditions

Electrical imaging (resistivity tomography) is increasingly used as a geophysical exploration technique in contaminated land research. The present work demonstrates the efficiency of electrical imaging in monitoring pollution plume evolution under both in-situ and model conditions. The in-situ campa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Environmental earth sciences 2005-05, Vol.47 (7), p.907-914
Hauptverfasser: DEPOUNTIS, Nikos, HARRIS, Charles, DAVIES, Michael C. R, KOUKIS, George, SABATAKAKIS, Nikos
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 914
container_issue 7
container_start_page 907
container_title Environmental earth sciences
container_volume 47
creator DEPOUNTIS, Nikos
HARRIS, Charles
DAVIES, Michael C. R
KOUKIS, George
SABATAKAKIS, Nikos
description Electrical imaging (resistivity tomography) is increasingly used as a geophysical exploration technique in contaminated land research. The present work demonstrates the efficiency of electrical imaging in monitoring pollution plume evolution under both in-situ and model conditions. The in-situ campaign was done at an unlined landfill site situated in the city of Patras, Hellas. A partially saturated zone of alluvial fan deposits underlies the site, which retards leachate percolation to the underlying water table. Electrical imaging provided details of the internal structure of the waste tip, and confirmed the presence of a leachate plume beneath the base of the landfill. This field data component provided the constraints for the design of a generic model of contaminant infiltration into partially saturated sand. The aim was to study leachate plume evolution in a laboratory environment. For this purpose, a miniaturised resistivity tomography technique, developed at Cardiff University, was used to image the resistivity distribution before during and after contaminant infiltration. Comparison of resulting two-dimensional tomography with observed plume geometry at the end of the test showed the miniaturised electrical imaging technique to be highly effective. Experiment showed that contaminant evolution taking place in the model was gravity-driven, with capillary water in the vadose zone being displaced by the denser contaminant solution.[PUBLICATION ABSTRACT]
doi_str_mv 10.1007/s00254-004-1219-5
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_20605745</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2086936301</sourcerecordid><originalsourceid>FETCH-LOGICAL-a356t-cc9c8b1d7dd0665afc08bda06b727ede170a66948fe3570e5595ab5a79c4fa793</originalsourceid><addsrcrecordid>eNpdkF1LHTEQhoO04OmxP8C7ILR30cluPjaXIq0Kgjd6HXKSWY3kJNtkt9B_3z09QsGbGRie92V4CDnncMkB9FUD6KRgAILxjhsmT8iGi75jIIz8RDZgRM-AgzwlX1p7AwDTabMhr9fTlKJ3cyyZlpFiQj_X9ZBo3LuXmF_oXGhC51_djHRKyx4p_i5p-Zdo8xIiNrrkgJXGzFqcF-pyoPsSMFFfcogHsp2Rz6NLDb--7y15_vnj6eaOPTze3t9cPzDXSzUz740fdjzoEEAp6UYPwy44UDvdaQzINTiljBhG7KUGlNJIt5NOGy_GdfZb8v3YO9Xya8E2231sHlNyGcvSbAcKpBZyBS8-gG9lqXn9zSqueW-GVdmW8CPka2mt4minunqpfywHexBvj-LtKt4exNtD8bf3YtdWj2N12cf2P6j0IDoD_V_xiISK</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>617139894</pqid></control><display><type>article</type><title>Application of electrical imaging to leachate plume evolution studies under in-situ and model conditions</title><source>SpringerNature Journals</source><creator>DEPOUNTIS, Nikos ; HARRIS, Charles ; DAVIES, Michael C. R ; KOUKIS, George ; SABATAKAKIS, Nikos</creator><creatorcontrib>DEPOUNTIS, Nikos ; HARRIS, Charles ; DAVIES, Michael C. R ; KOUKIS, George ; SABATAKAKIS, Nikos</creatorcontrib><description>Electrical imaging (resistivity tomography) is increasingly used as a geophysical exploration technique in contaminated land research. The present work demonstrates the efficiency of electrical imaging in monitoring pollution plume evolution under both in-situ and model conditions. The in-situ campaign was done at an unlined landfill site situated in the city of Patras, Hellas. A partially saturated zone of alluvial fan deposits underlies the site, which retards leachate percolation to the underlying water table. Electrical imaging provided details of the internal structure of the waste tip, and confirmed the presence of a leachate plume beneath the base of the landfill. This field data component provided the constraints for the design of a generic model of contaminant infiltration into partially saturated sand. The aim was to study leachate plume evolution in a laboratory environment. For this purpose, a miniaturised resistivity tomography technique, developed at Cardiff University, was used to image the resistivity distribution before during and after contaminant infiltration. Comparison of resulting two-dimensional tomography with observed plume geometry at the end of the test showed the miniaturised electrical imaging technique to be highly effective. Experiment showed that contaminant evolution taking place in the model was gravity-driven, with capillary water in the vadose zone being displaced by the denser contaminant solution.[PUBLICATION ABSTRACT]</description><identifier>ISSN: 0943-0105</identifier><identifier>ISSN: 1866-6280</identifier><identifier>EISSN: 1432-0495</identifier><identifier>EISSN: 1866-6299</identifier><identifier>DOI: 10.1007/s00254-004-1219-5</identifier><language>eng</language><publisher>Berlin: Springer</publisher><subject>Alluvial fans ; Capillary water ; Contaminants ; Earth sciences ; Earth, ocean, space ; Engineering and environment geology. Geothermics ; Evolution ; Exact sciences and technology ; Geophysical exploration ; Geophysics: general, magnetic, electric and thermic methods and properties ; Groundwater ; Infiltration ; Internal geophysics ; Land pollution ; Landfills ; Leachates ; Medical imaging ; Pollution monitoring ; Pollution, environment geology ; Vadose water ; Waste disposal sites ; Water table</subject><ispartof>Environmental earth sciences, 2005-05, Vol.47 (7), p.907-914</ispartof><rights>2005 INIST-CNRS</rights><rights>Springer-Verlag 2005</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a356t-cc9c8b1d7dd0665afc08bda06b727ede170a66948fe3570e5595ab5a79c4fa793</citedby><cites>FETCH-LOGICAL-a356t-cc9c8b1d7dd0665afc08bda06b727ede170a66948fe3570e5595ab5a79c4fa793</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=16784290$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>DEPOUNTIS, Nikos</creatorcontrib><creatorcontrib>HARRIS, Charles</creatorcontrib><creatorcontrib>DAVIES, Michael C. R</creatorcontrib><creatorcontrib>KOUKIS, George</creatorcontrib><creatorcontrib>SABATAKAKIS, Nikos</creatorcontrib><title>Application of electrical imaging to leachate plume evolution studies under in-situ and model conditions</title><title>Environmental earth sciences</title><description>Electrical imaging (resistivity tomography) is increasingly used as a geophysical exploration technique in contaminated land research. The present work demonstrates the efficiency of electrical imaging in monitoring pollution plume evolution under both in-situ and model conditions. The in-situ campaign was done at an unlined landfill site situated in the city of Patras, Hellas. A partially saturated zone of alluvial fan deposits underlies the site, which retards leachate percolation to the underlying water table. Electrical imaging provided details of the internal structure of the waste tip, and confirmed the presence of a leachate plume beneath the base of the landfill. This field data component provided the constraints for the design of a generic model of contaminant infiltration into partially saturated sand. The aim was to study leachate plume evolution in a laboratory environment. For this purpose, a miniaturised resistivity tomography technique, developed at Cardiff University, was used to image the resistivity distribution before during and after contaminant infiltration. Comparison of resulting two-dimensional tomography with observed plume geometry at the end of the test showed the miniaturised electrical imaging technique to be highly effective. Experiment showed that contaminant evolution taking place in the model was gravity-driven, with capillary water in the vadose zone being displaced by the denser contaminant solution.[PUBLICATION ABSTRACT]</description><subject>Alluvial fans</subject><subject>Capillary water</subject><subject>Contaminants</subject><subject>Earth sciences</subject><subject>Earth, ocean, space</subject><subject>Engineering and environment geology. Geothermics</subject><subject>Evolution</subject><subject>Exact sciences and technology</subject><subject>Geophysical exploration</subject><subject>Geophysics: general, magnetic, electric and thermic methods and properties</subject><subject>Groundwater</subject><subject>Infiltration</subject><subject>Internal geophysics</subject><subject>Land pollution</subject><subject>Landfills</subject><subject>Leachates</subject><subject>Medical imaging</subject><subject>Pollution monitoring</subject><subject>Pollution, environment geology</subject><subject>Vadose water</subject><subject>Waste disposal sites</subject><subject>Water table</subject><issn>0943-0105</issn><issn>1866-6280</issn><issn>1432-0495</issn><issn>1866-6299</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNpdkF1LHTEQhoO04OmxP8C7ILR30cluPjaXIq0Kgjd6HXKSWY3kJNtkt9B_3z09QsGbGRie92V4CDnncMkB9FUD6KRgAILxjhsmT8iGi75jIIz8RDZgRM-AgzwlX1p7AwDTabMhr9fTlKJ3cyyZlpFiQj_X9ZBo3LuXmF_oXGhC51_djHRKyx4p_i5p-Zdo8xIiNrrkgJXGzFqcF-pyoPsSMFFfcogHsp2Rz6NLDb--7y15_vnj6eaOPTze3t9cPzDXSzUz740fdjzoEEAp6UYPwy44UDvdaQzINTiljBhG7KUGlNJIt5NOGy_GdfZb8v3YO9Xya8E2231sHlNyGcvSbAcKpBZyBS8-gG9lqXn9zSqueW-GVdmW8CPka2mt4minunqpfywHexBvj-LtKt4exNtD8bf3YtdWj2N12cf2P6j0IDoD_V_xiISK</recordid><startdate>20050501</startdate><enddate>20050501</enddate><creator>DEPOUNTIS, Nikos</creator><creator>HARRIS, Charles</creator><creator>DAVIES, Michael C. R</creator><creator>KOUKIS, George</creator><creator>SABATAKAKIS, Nikos</creator><general>Springer</general><general>Springer Nature B.V</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7ST</scope><scope>7TG</scope><scope>7UA</scope><scope>7XB</scope><scope>88I</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ATCPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>BKSAR</scope><scope>C1K</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>F1W</scope><scope>GNUQQ</scope><scope>H96</scope><scope>HCIFZ</scope><scope>KL.</scope><scope>L.G</scope><scope>M2P</scope><scope>PATMY</scope><scope>PCBAR</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PYCSY</scope><scope>Q9U</scope><scope>SOI</scope><scope>7TV</scope><scope>7U6</scope><scope>H97</scope></search><sort><creationdate>20050501</creationdate><title>Application of electrical imaging to leachate plume evolution studies under in-situ and model conditions</title><author>DEPOUNTIS, Nikos ; HARRIS, Charles ; DAVIES, Michael C. R ; KOUKIS, George ; SABATAKAKIS, Nikos</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a356t-cc9c8b1d7dd0665afc08bda06b727ede170a66948fe3570e5595ab5a79c4fa793</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Alluvial fans</topic><topic>Capillary water</topic><topic>Contaminants</topic><topic>Earth sciences</topic><topic>Earth, ocean, space</topic><topic>Engineering and environment geology. Geothermics</topic><topic>Evolution</topic><topic>Exact sciences and technology</topic><topic>Geophysical exploration</topic><topic>Geophysics: general, magnetic, electric and thermic methods and properties</topic><topic>Groundwater</topic><topic>Infiltration</topic><topic>Internal geophysics</topic><topic>Land pollution</topic><topic>Landfills</topic><topic>Leachates</topic><topic>Medical imaging</topic><topic>Pollution monitoring</topic><topic>Pollution, environment geology</topic><topic>Vadose water</topic><topic>Waste disposal sites</topic><topic>Water table</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>DEPOUNTIS, Nikos</creatorcontrib><creatorcontrib>HARRIS, Charles</creatorcontrib><creatorcontrib>DAVIES, Michael C. R</creatorcontrib><creatorcontrib>KOUKIS, George</creatorcontrib><creatorcontrib>SABATAKAKIS, Nikos</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Environment Abstracts</collection><collection>Meteorological &amp; Geoastrophysical Abstracts</collection><collection>Water Resources Abstracts</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Science Database (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Agricultural &amp; Environmental Science Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Natural Science Collection</collection><collection>Earth, Atmospheric &amp; Aquatic Science Collection</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>ProQuest Central Student</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) 2: Ocean Technology, Policy &amp; Non-Living Resources</collection><collection>SciTech Premium Collection</collection><collection>Meteorological &amp; Geoastrophysical Abstracts - Academic</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) Professional</collection><collection>Science Database</collection><collection>Environmental Science Database</collection><collection>Earth, Atmospheric &amp; Aquatic Science Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>Environmental Science Collection</collection><collection>ProQuest Central Basic</collection><collection>Environment Abstracts</collection><collection>Pollution Abstracts</collection><collection>Sustainability Science Abstracts</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) 3: Aquatic Pollution &amp; Environmental Quality</collection><jtitle>Environmental earth sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>DEPOUNTIS, Nikos</au><au>HARRIS, Charles</au><au>DAVIES, Michael C. R</au><au>KOUKIS, George</au><au>SABATAKAKIS, Nikos</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Application of electrical imaging to leachate plume evolution studies under in-situ and model conditions</atitle><jtitle>Environmental earth sciences</jtitle><date>2005-05-01</date><risdate>2005</risdate><volume>47</volume><issue>7</issue><spage>907</spage><epage>914</epage><pages>907-914</pages><issn>0943-0105</issn><issn>1866-6280</issn><eissn>1432-0495</eissn><eissn>1866-6299</eissn><abstract>Electrical imaging (resistivity tomography) is increasingly used as a geophysical exploration technique in contaminated land research. The present work demonstrates the efficiency of electrical imaging in monitoring pollution plume evolution under both in-situ and model conditions. The in-situ campaign was done at an unlined landfill site situated in the city of Patras, Hellas. A partially saturated zone of alluvial fan deposits underlies the site, which retards leachate percolation to the underlying water table. Electrical imaging provided details of the internal structure of the waste tip, and confirmed the presence of a leachate plume beneath the base of the landfill. This field data component provided the constraints for the design of a generic model of contaminant infiltration into partially saturated sand. The aim was to study leachate plume evolution in a laboratory environment. For this purpose, a miniaturised resistivity tomography technique, developed at Cardiff University, was used to image the resistivity distribution before during and after contaminant infiltration. Comparison of resulting two-dimensional tomography with observed plume geometry at the end of the test showed the miniaturised electrical imaging technique to be highly effective. Experiment showed that contaminant evolution taking place in the model was gravity-driven, with capillary water in the vadose zone being displaced by the denser contaminant solution.[PUBLICATION ABSTRACT]</abstract><cop>Berlin</cop><pub>Springer</pub><doi>10.1007/s00254-004-1219-5</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0943-0105
ispartof Environmental earth sciences, 2005-05, Vol.47 (7), p.907-914
issn 0943-0105
1866-6280
1432-0495
1866-6299
language eng
recordid cdi_proquest_miscellaneous_20605745
source SpringerNature Journals
subjects Alluvial fans
Capillary water
Contaminants
Earth sciences
Earth, ocean, space
Engineering and environment geology. Geothermics
Evolution
Exact sciences and technology
Geophysical exploration
Geophysics: general, magnetic, electric and thermic methods and properties
Groundwater
Infiltration
Internal geophysics
Land pollution
Landfills
Leachates
Medical imaging
Pollution monitoring
Pollution, environment geology
Vadose water
Waste disposal sites
Water table
title Application of electrical imaging to leachate plume evolution studies under in-situ and model conditions
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T12%3A20%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Application%20of%20electrical%20imaging%20to%20leachate%20plume%20evolution%20studies%20under%20in-situ%20and%20model%20conditions&rft.jtitle=Environmental%20earth%20sciences&rft.au=DEPOUNTIS,%20Nikos&rft.date=2005-05-01&rft.volume=47&rft.issue=7&rft.spage=907&rft.epage=914&rft.pages=907-914&rft.issn=0943-0105&rft.eissn=1432-0495&rft_id=info:doi/10.1007/s00254-004-1219-5&rft_dat=%3Cproquest_cross%3E2086936301%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=617139894&rft_id=info:pmid/&rfr_iscdi=true