The effect of cochlear implants on vestibular-evoked myogenic potential responses and postural stability

Current spread by electrical stimulation via inserted cochlear implant (CI) electrodes and the consequential increase in sound input can affect the equilibrium of patients. The aim of the present study was to clarify the effect of CIs on the equilibrium of patients through cervical vestibular-evoked...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Auris, nasus, larynx nasus, larynx, 2019-02, Vol.46 (1), p.50-57
Hauptverfasser: Miwa, Toru, Minoda, Ryosei, Matsuyoshi, Hidetake, Takeda, Hiroki
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 57
container_issue 1
container_start_page 50
container_title Auris, nasus, larynx
container_volume 46
creator Miwa, Toru
Minoda, Ryosei
Matsuyoshi, Hidetake
Takeda, Hiroki
description Current spread by electrical stimulation via inserted cochlear implant (CI) electrodes and the consequential increase in sound input can affect the equilibrium of patients. The aim of the present study was to clarify the effect of CIs on the equilibrium of patients through cervical vestibular-evoked myogenic potential (cVEMP) testing and static stabilometry performed with the CIs turned on (CI-on) and off (CI-off). This prospective study included nine adult patients who underwent unilateral cochlear implantation surgery at our institution. cVEMP testing and stabilometry were performed before surgery and repeated after surgery in the CI-on and CI-off modes. Before surgery, cVEMP responses were diminished in five of the nine patients (55.6%), while the results of stabilometry were poor in six patients (66.7%). After surgery, both cVEMP responses and stabilometry findings in the CI-off mode exhibited significant deterioration relative to the preoperative results (cVEMP: 7/9, 77.8%; stabilometry: 7/9, 77.8%). However, in the CI-on mode, there were significant improvements in both test results relative to the findings in the CI-off mode for all patients. CIs compensated for the surgical trauma-induced deterioration in static postural stability when turned on, resulting in a considerable improvement. Our findings suggest that postoperative cVEMP testing in the CI-on and CI-off modes will enable more accurate assessment of the saccule–inferior vestibular nerve system function after cochlear implant surgery.
doi_str_mv 10.1016/j.anl.2018.06.002
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2059042246</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0385814618302700</els_id><sourcerecordid>2059042246</sourcerecordid><originalsourceid>FETCH-LOGICAL-c443t-406404e9283ce62bfddf980d5bbb934cbf25611a39c70bea4df916470cb74e8a3</originalsourceid><addsrcrecordid>eNp9kEFv1DAQha2Kim4LP4AL8pFLwthxnFicUFWgUiUu7dmynUnXSxIH21lp_z2utnDkNNLMe0_zPkI-MKgZMPn5UJtlqjmwvgZZA_ALsmN9pyomOvmG7KDp26pnQl6R65QOANB0jXpLrrhSTdsrviP7xz1SHEd0mYaRuuD2E5pI_bxOZsmJhoUeMWVvt8nECo_hFw50PoVnXLyja8i4ZG8mGjGtYUmYqFmGsk95i2WdsrF-8vn0jlyOZkr4_nXekKdvd4-3P6qHn9_vb78-VE6IJlcCpACBiveNQ8ntOAyj6mForbWqEc6OvJWMmUa5DiwaUc5Mig6c7QT2prkhn865awy_t_K5nn1yOJU2GLakObQKBOdCFik7S10MKUUc9Rr9bOJJM9AvgPVBF8D6BbAGqQvg4vn4Gr_ZGYd_jr9Ei-DLWYCl5NFj1Ml5XBwOPhbIegj-P_F_AEsijd8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2059042246</pqid></control><display><type>article</type><title>The effect of cochlear implants on vestibular-evoked myogenic potential responses and postural stability</title><source>Elsevier ScienceDirect Journals</source><creator>Miwa, Toru ; Minoda, Ryosei ; Matsuyoshi, Hidetake ; Takeda, Hiroki</creator><creatorcontrib>Miwa, Toru ; Minoda, Ryosei ; Matsuyoshi, Hidetake ; Takeda, Hiroki</creatorcontrib><description>Current spread by electrical stimulation via inserted cochlear implant (CI) electrodes and the consequential increase in sound input can affect the equilibrium of patients. The aim of the present study was to clarify the effect of CIs on the equilibrium of patients through cervical vestibular-evoked myogenic potential (cVEMP) testing and static stabilometry performed with the CIs turned on (CI-on) and off (CI-off). This prospective study included nine adult patients who underwent unilateral cochlear implantation surgery at our institution. cVEMP testing and stabilometry were performed before surgery and repeated after surgery in the CI-on and CI-off modes. Before surgery, cVEMP responses were diminished in five of the nine patients (55.6%), while the results of stabilometry were poor in six patients (66.7%). After surgery, both cVEMP responses and stabilometry findings in the CI-off mode exhibited significant deterioration relative to the preoperative results (cVEMP: 7/9, 77.8%; stabilometry: 7/9, 77.8%). However, in the CI-on mode, there were significant improvements in both test results relative to the findings in the CI-off mode for all patients. CIs compensated for the surgical trauma-induced deterioration in static postural stability when turned on, resulting in a considerable improvement. Our findings suggest that postoperative cVEMP testing in the CI-on and CI-off modes will enable more accurate assessment of the saccule–inferior vestibular nerve system function after cochlear implant surgery.</description><identifier>ISSN: 0385-8146</identifier><identifier>EISSN: 1879-1476</identifier><identifier>DOI: 10.1016/j.anl.2018.06.002</identifier><identifier>PMID: 29935892</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Cervical vestibular-evoked myogenic potential ; Cochlear implant ; Hearing loss ; Postural stability ; Stabilometry</subject><ispartof>Auris, nasus, larynx, 2019-02, Vol.46 (1), p.50-57</ispartof><rights>2018 Elsevier B.V.</rights><rights>Copyright © 2018 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c443t-406404e9283ce62bfddf980d5bbb934cbf25611a39c70bea4df916470cb74e8a3</citedby><cites>FETCH-LOGICAL-c443t-406404e9283ce62bfddf980d5bbb934cbf25611a39c70bea4df916470cb74e8a3</cites><orcidid>0000-0002-5977-0056</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0385814618302700$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65534</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29935892$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Miwa, Toru</creatorcontrib><creatorcontrib>Minoda, Ryosei</creatorcontrib><creatorcontrib>Matsuyoshi, Hidetake</creatorcontrib><creatorcontrib>Takeda, Hiroki</creatorcontrib><title>The effect of cochlear implants on vestibular-evoked myogenic potential responses and postural stability</title><title>Auris, nasus, larynx</title><addtitle>Auris Nasus Larynx</addtitle><description>Current spread by electrical stimulation via inserted cochlear implant (CI) electrodes and the consequential increase in sound input can affect the equilibrium of patients. The aim of the present study was to clarify the effect of CIs on the equilibrium of patients through cervical vestibular-evoked myogenic potential (cVEMP) testing and static stabilometry performed with the CIs turned on (CI-on) and off (CI-off). This prospective study included nine adult patients who underwent unilateral cochlear implantation surgery at our institution. cVEMP testing and stabilometry were performed before surgery and repeated after surgery in the CI-on and CI-off modes. Before surgery, cVEMP responses were diminished in five of the nine patients (55.6%), while the results of stabilometry were poor in six patients (66.7%). After surgery, both cVEMP responses and stabilometry findings in the CI-off mode exhibited significant deterioration relative to the preoperative results (cVEMP: 7/9, 77.8%; stabilometry: 7/9, 77.8%). However, in the CI-on mode, there were significant improvements in both test results relative to the findings in the CI-off mode for all patients. CIs compensated for the surgical trauma-induced deterioration in static postural stability when turned on, resulting in a considerable improvement. Our findings suggest that postoperative cVEMP testing in the CI-on and CI-off modes will enable more accurate assessment of the saccule–inferior vestibular nerve system function after cochlear implant surgery.</description><subject>Cervical vestibular-evoked myogenic potential</subject><subject>Cochlear implant</subject><subject>Hearing loss</subject><subject>Postural stability</subject><subject>Stabilometry</subject><issn>0385-8146</issn><issn>1879-1476</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp9kEFv1DAQha2Kim4LP4AL8pFLwthxnFicUFWgUiUu7dmynUnXSxIH21lp_z2utnDkNNLMe0_zPkI-MKgZMPn5UJtlqjmwvgZZA_ALsmN9pyomOvmG7KDp26pnQl6R65QOANB0jXpLrrhSTdsrviP7xz1SHEd0mYaRuuD2E5pI_bxOZsmJhoUeMWVvt8nECo_hFw50PoVnXLyja8i4ZG8mGjGtYUmYqFmGsk95i2WdsrF-8vn0jlyOZkr4_nXekKdvd4-3P6qHn9_vb78-VE6IJlcCpACBiveNQ8ntOAyj6mForbWqEc6OvJWMmUa5DiwaUc5Mig6c7QT2prkhn865awy_t_K5nn1yOJU2GLakObQKBOdCFik7S10MKUUc9Rr9bOJJM9AvgPVBF8D6BbAGqQvg4vn4Gr_ZGYd_jr9Ei-DLWYCl5NFj1Ml5XBwOPhbIegj-P_F_AEsijd8</recordid><startdate>201902</startdate><enddate>201902</enddate><creator>Miwa, Toru</creator><creator>Minoda, Ryosei</creator><creator>Matsuyoshi, Hidetake</creator><creator>Takeda, Hiroki</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-5977-0056</orcidid></search><sort><creationdate>201902</creationdate><title>The effect of cochlear implants on vestibular-evoked myogenic potential responses and postural stability</title><author>Miwa, Toru ; Minoda, Ryosei ; Matsuyoshi, Hidetake ; Takeda, Hiroki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c443t-406404e9283ce62bfddf980d5bbb934cbf25611a39c70bea4df916470cb74e8a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Cervical vestibular-evoked myogenic potential</topic><topic>Cochlear implant</topic><topic>Hearing loss</topic><topic>Postural stability</topic><topic>Stabilometry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Miwa, Toru</creatorcontrib><creatorcontrib>Minoda, Ryosei</creatorcontrib><creatorcontrib>Matsuyoshi, Hidetake</creatorcontrib><creatorcontrib>Takeda, Hiroki</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Auris, nasus, larynx</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Miwa, Toru</au><au>Minoda, Ryosei</au><au>Matsuyoshi, Hidetake</au><au>Takeda, Hiroki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The effect of cochlear implants on vestibular-evoked myogenic potential responses and postural stability</atitle><jtitle>Auris, nasus, larynx</jtitle><addtitle>Auris Nasus Larynx</addtitle><date>2019-02</date><risdate>2019</risdate><volume>46</volume><issue>1</issue><spage>50</spage><epage>57</epage><pages>50-57</pages><issn>0385-8146</issn><eissn>1879-1476</eissn><abstract>Current spread by electrical stimulation via inserted cochlear implant (CI) electrodes and the consequential increase in sound input can affect the equilibrium of patients. The aim of the present study was to clarify the effect of CIs on the equilibrium of patients through cervical vestibular-evoked myogenic potential (cVEMP) testing and static stabilometry performed with the CIs turned on (CI-on) and off (CI-off). This prospective study included nine adult patients who underwent unilateral cochlear implantation surgery at our institution. cVEMP testing and stabilometry were performed before surgery and repeated after surgery in the CI-on and CI-off modes. Before surgery, cVEMP responses were diminished in five of the nine patients (55.6%), while the results of stabilometry were poor in six patients (66.7%). After surgery, both cVEMP responses and stabilometry findings in the CI-off mode exhibited significant deterioration relative to the preoperative results (cVEMP: 7/9, 77.8%; stabilometry: 7/9, 77.8%). However, in the CI-on mode, there were significant improvements in both test results relative to the findings in the CI-off mode for all patients. CIs compensated for the surgical trauma-induced deterioration in static postural stability when turned on, resulting in a considerable improvement. Our findings suggest that postoperative cVEMP testing in the CI-on and CI-off modes will enable more accurate assessment of the saccule–inferior vestibular nerve system function after cochlear implant surgery.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>29935892</pmid><doi>10.1016/j.anl.2018.06.002</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0002-5977-0056</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0385-8146
ispartof Auris, nasus, larynx, 2019-02, Vol.46 (1), p.50-57
issn 0385-8146
1879-1476
language eng
recordid cdi_proquest_miscellaneous_2059042246
source Elsevier ScienceDirect Journals
subjects Cervical vestibular-evoked myogenic potential
Cochlear implant
Hearing loss
Postural stability
Stabilometry
title The effect of cochlear implants on vestibular-evoked myogenic potential responses and postural stability
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-15T13%3A34%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20effect%20of%20cochlear%20implants%20on%20vestibular-evoked%20myogenic%20potential%20responses%20and%20postural%20stability&rft.jtitle=Auris,%20nasus,%20larynx&rft.au=Miwa,%20Toru&rft.date=2019-02&rft.volume=46&rft.issue=1&rft.spage=50&rft.epage=57&rft.pages=50-57&rft.issn=0385-8146&rft.eissn=1879-1476&rft_id=info:doi/10.1016/j.anl.2018.06.002&rft_dat=%3Cproquest_cross%3E2059042246%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2059042246&rft_id=info:pmid/29935892&rft_els_id=S0385814618302700&rfr_iscdi=true