Experimental validation of the CompuFlo® epidural controlled system to identify the epidural space and its clinical use in difficult obstetric cases

•The CompuFlo® device identifies the ligamentum flavum and the epidural space.•It was associated with successful epidural block.•This technology may assist the trainee in difficult cases. This prospective study was designed to validate the CompuFlo® device and to assess its use in difficult epidural...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of obstetric anesthesia 2018-11, Vol.36, p.28-33
Hauptverfasser: Capogna, G., Camorcia, M., Coccoluto, A., Micaglio, M., Velardo, M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 33
container_issue
container_start_page 28
container_title International journal of obstetric anesthesia
container_volume 36
creator Capogna, G.
Camorcia, M.
Coccoluto, A.
Micaglio, M.
Velardo, M.
description •The CompuFlo® device identifies the ligamentum flavum and the epidural space.•It was associated with successful epidural block.•This technology may assist the trainee in difficult cases. This prospective study was designed to validate the CompuFlo® device and to assess its use in difficult epidural placement. In the first part of the study, 30 parturients requesting labor epidural analgesia were recruited. The block was performed by an expert anesthesiologist, with the Tuohy needle connected to the CompuFlo® device to evaluate the agreement between the anesthesiologist’s reported sensation and the variation of pressure recorded by the CompuFlo®. In the second part of the study, 56 consecutive parturients, for whom at least two complete needle reinsertions were made by trainees during epidural placement for labor analgesia, were enrolled. CompuFlo® was used as a rescue tool for the subsequent attempt. In all cases epidural analgesia was successful and no complications were noted. There was a good correlation between the operator’s feelings and the delta of pressure recorded by the CompuFlo®, for both identification of the ligamentum flavum and of the epidural space (Rho = 0.79; tau = 0.67). In the second part of the study, all the difficult blocks performed with the CompuFlo® were successful after a single attempt. The pressure curves of false loss-of-resistance were significantly different from the true loss-of-resistance (P 
doi_str_mv 10.1016/j.ijoa.2018.04.008
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2057139546</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0959289X18300050</els_id><sourcerecordid>2057139546</sourcerecordid><originalsourceid>FETCH-LOGICAL-c356t-cf381691061c5b61189229e5af88de8fe894e4818de11b95f94363a550928e153</originalsourceid><addsrcrecordid>eNp9kUGKFDEYhYMoTs_oBVxIlm6qTKoq1Qm4kWZGBwbcKLgL6eQP_k2qUiapwT6I1_AQnsy0Pc7SVUj43gd5j5BXnLWc8fHtocVDNG3HuGzZ0DImn5ANF33X9P12eEo2TAnVdFJ9vSCXOR8YY6qX43Ny0SnFh60cNuTn9Y8FEk4wFxPovQnoTME40-hp-QZ0F6dlvQnx9y8KC7o1VcrGuaQYAjiaj7nAREuk6KoC_fFv6hHNi7FAzewolkxtwBltfV4zUJypQ-_RrqHQuK-ektBSazLkF-SZNyHDy4fziny5uf68-9jcffpwu3t_19hejKWxvpd8VJyN3Ir9yLlUXadAGC-lA-lBqgEGyeuF870SXg392BshmOok1KauyJuzd0nx-wq56AmzhRDMDHHNumNiy3slhrGi3Rm1KeacwOul1mbSUXOmT3Pogz7NoU9zaDboOkcNvX7wr_sJ3GPkX_8VeHcGoP7yHiHpbBFmCw4T2KJdxP_5_wCvhJ8V</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2057139546</pqid></control><display><type>article</type><title>Experimental validation of the CompuFlo® epidural controlled system to identify the epidural space and its clinical use in difficult obstetric cases</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>Capogna, G. ; Camorcia, M. ; Coccoluto, A. ; Micaglio, M. ; Velardo, M.</creator><creatorcontrib>Capogna, G. ; Camorcia, M. ; Coccoluto, A. ; Micaglio, M. ; Velardo, M.</creatorcontrib><description>•The CompuFlo® device identifies the ligamentum flavum and the epidural space.•It was associated with successful epidural block.•This technology may assist the trainee in difficult cases. This prospective study was designed to validate the CompuFlo® device and to assess its use in difficult epidural placement. In the first part of the study, 30 parturients requesting labor epidural analgesia were recruited. The block was performed by an expert anesthesiologist, with the Tuohy needle connected to the CompuFlo® device to evaluate the agreement between the anesthesiologist’s reported sensation and the variation of pressure recorded by the CompuFlo®. In the second part of the study, 56 consecutive parturients, for whom at least two complete needle reinsertions were made by trainees during epidural placement for labor analgesia, were enrolled. CompuFlo® was used as a rescue tool for the subsequent attempt. In all cases epidural analgesia was successful and no complications were noted. There was a good correlation between the operator’s feelings and the delta of pressure recorded by the CompuFlo®, for both identification of the ligamentum flavum and of the epidural space (Rho = 0.79; tau = 0.67). In the second part of the study, all the difficult blocks performed with the CompuFlo® were successful after a single attempt. The pressure curves of false loss-of-resistance were significantly different from the true loss-of-resistance (P &lt;0.0001) CompuFlo® was validated as a tool to identify the epidural space. It may also assist trainees in successful epidural placement in difficult cases.</description><identifier>ISSN: 0959-289X</identifier><identifier>EISSN: 1532-3374</identifier><identifier>DOI: 10.1016/j.ijoa.2018.04.008</identifier><identifier>PMID: 29914784</identifier><language>eng</language><publisher>Netherlands: Elsevier Ltd</publisher><subject>Adult ; Analgesia, Epidural - instrumentation ; Analgesia, Epidural - methods ; Analgesia, Obstetrical - instrumentation ; Analgesia, Obstetrical - methods ; Epidural Space ; Epidural technique ; Female ; Humans ; Labor analgesia ; Labor, Obstetric ; Loss-of-resistance device ; Needles ; Pregnancy ; Prospective Studies ; Reproducibility of Results</subject><ispartof>International journal of obstetric anesthesia, 2018-11, Vol.36, p.28-33</ispartof><rights>2018 Elsevier Ltd</rights><rights>Copyright © 2018 Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c356t-cf381691061c5b61189229e5af88de8fe894e4818de11b95f94363a550928e153</citedby><cites>FETCH-LOGICAL-c356t-cf381691061c5b61189229e5af88de8fe894e4818de11b95f94363a550928e153</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.ijoa.2018.04.008$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3541,27915,27916,45986</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29914784$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Capogna, G.</creatorcontrib><creatorcontrib>Camorcia, M.</creatorcontrib><creatorcontrib>Coccoluto, A.</creatorcontrib><creatorcontrib>Micaglio, M.</creatorcontrib><creatorcontrib>Velardo, M.</creatorcontrib><title>Experimental validation of the CompuFlo® epidural controlled system to identify the epidural space and its clinical use in difficult obstetric cases</title><title>International journal of obstetric anesthesia</title><addtitle>Int J Obstet Anesth</addtitle><description>•The CompuFlo® device identifies the ligamentum flavum and the epidural space.•It was associated with successful epidural block.•This technology may assist the trainee in difficult cases. This prospective study was designed to validate the CompuFlo® device and to assess its use in difficult epidural placement. In the first part of the study, 30 parturients requesting labor epidural analgesia were recruited. The block was performed by an expert anesthesiologist, with the Tuohy needle connected to the CompuFlo® device to evaluate the agreement between the anesthesiologist’s reported sensation and the variation of pressure recorded by the CompuFlo®. In the second part of the study, 56 consecutive parturients, for whom at least two complete needle reinsertions were made by trainees during epidural placement for labor analgesia, were enrolled. CompuFlo® was used as a rescue tool for the subsequent attempt. In all cases epidural analgesia was successful and no complications were noted. There was a good correlation between the operator’s feelings and the delta of pressure recorded by the CompuFlo®, for both identification of the ligamentum flavum and of the epidural space (Rho = 0.79; tau = 0.67). In the second part of the study, all the difficult blocks performed with the CompuFlo® were successful after a single attempt. The pressure curves of false loss-of-resistance were significantly different from the true loss-of-resistance (P &lt;0.0001) CompuFlo® was validated as a tool to identify the epidural space. It may also assist trainees in successful epidural placement in difficult cases.</description><subject>Adult</subject><subject>Analgesia, Epidural - instrumentation</subject><subject>Analgesia, Epidural - methods</subject><subject>Analgesia, Obstetrical - instrumentation</subject><subject>Analgesia, Obstetrical - methods</subject><subject>Epidural Space</subject><subject>Epidural technique</subject><subject>Female</subject><subject>Humans</subject><subject>Labor analgesia</subject><subject>Labor, Obstetric</subject><subject>Loss-of-resistance device</subject><subject>Needles</subject><subject>Pregnancy</subject><subject>Prospective Studies</subject><subject>Reproducibility of Results</subject><issn>0959-289X</issn><issn>1532-3374</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kUGKFDEYhYMoTs_oBVxIlm6qTKoq1Qm4kWZGBwbcKLgL6eQP_k2qUiapwT6I1_AQnsy0Pc7SVUj43gd5j5BXnLWc8fHtocVDNG3HuGzZ0DImn5ANF33X9P12eEo2TAnVdFJ9vSCXOR8YY6qX43Ny0SnFh60cNuTn9Y8FEk4wFxPovQnoTME40-hp-QZ0F6dlvQnx9y8KC7o1VcrGuaQYAjiaj7nAREuk6KoC_fFv6hHNi7FAzewolkxtwBltfV4zUJypQ-_RrqHQuK-ektBSazLkF-SZNyHDy4fziny5uf68-9jcffpwu3t_19hejKWxvpd8VJyN3Ir9yLlUXadAGC-lA-lBqgEGyeuF870SXg392BshmOok1KauyJuzd0nx-wq56AmzhRDMDHHNumNiy3slhrGi3Rm1KeacwOul1mbSUXOmT3Pogz7NoU9zaDboOkcNvX7wr_sJ3GPkX_8VeHcGoP7yHiHpbBFmCw4T2KJdxP_5_wCvhJ8V</recordid><startdate>201811</startdate><enddate>201811</enddate><creator>Capogna, G.</creator><creator>Camorcia, M.</creator><creator>Coccoluto, A.</creator><creator>Micaglio, M.</creator><creator>Velardo, M.</creator><general>Elsevier Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201811</creationdate><title>Experimental validation of the CompuFlo® epidural controlled system to identify the epidural space and its clinical use in difficult obstetric cases</title><author>Capogna, G. ; Camorcia, M. ; Coccoluto, A. ; Micaglio, M. ; Velardo, M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c356t-cf381691061c5b61189229e5af88de8fe894e4818de11b95f94363a550928e153</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Adult</topic><topic>Analgesia, Epidural - instrumentation</topic><topic>Analgesia, Epidural - methods</topic><topic>Analgesia, Obstetrical - instrumentation</topic><topic>Analgesia, Obstetrical - methods</topic><topic>Epidural Space</topic><topic>Epidural technique</topic><topic>Female</topic><topic>Humans</topic><topic>Labor analgesia</topic><topic>Labor, Obstetric</topic><topic>Loss-of-resistance device</topic><topic>Needles</topic><topic>Pregnancy</topic><topic>Prospective Studies</topic><topic>Reproducibility of Results</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Capogna, G.</creatorcontrib><creatorcontrib>Camorcia, M.</creatorcontrib><creatorcontrib>Coccoluto, A.</creatorcontrib><creatorcontrib>Micaglio, M.</creatorcontrib><creatorcontrib>Velardo, M.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>International journal of obstetric anesthesia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Capogna, G.</au><au>Camorcia, M.</au><au>Coccoluto, A.</au><au>Micaglio, M.</au><au>Velardo, M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Experimental validation of the CompuFlo® epidural controlled system to identify the epidural space and its clinical use in difficult obstetric cases</atitle><jtitle>International journal of obstetric anesthesia</jtitle><addtitle>Int J Obstet Anesth</addtitle><date>2018-11</date><risdate>2018</risdate><volume>36</volume><spage>28</spage><epage>33</epage><pages>28-33</pages><issn>0959-289X</issn><eissn>1532-3374</eissn><abstract>•The CompuFlo® device identifies the ligamentum flavum and the epidural space.•It was associated with successful epidural block.•This technology may assist the trainee in difficult cases. This prospective study was designed to validate the CompuFlo® device and to assess its use in difficult epidural placement. In the first part of the study, 30 parturients requesting labor epidural analgesia were recruited. The block was performed by an expert anesthesiologist, with the Tuohy needle connected to the CompuFlo® device to evaluate the agreement between the anesthesiologist’s reported sensation and the variation of pressure recorded by the CompuFlo®. In the second part of the study, 56 consecutive parturients, for whom at least two complete needle reinsertions were made by trainees during epidural placement for labor analgesia, were enrolled. CompuFlo® was used as a rescue tool for the subsequent attempt. In all cases epidural analgesia was successful and no complications were noted. There was a good correlation between the operator’s feelings and the delta of pressure recorded by the CompuFlo®, for both identification of the ligamentum flavum and of the epidural space (Rho = 0.79; tau = 0.67). In the second part of the study, all the difficult blocks performed with the CompuFlo® were successful after a single attempt. The pressure curves of false loss-of-resistance were significantly different from the true loss-of-resistance (P &lt;0.0001) CompuFlo® was validated as a tool to identify the epidural space. It may also assist trainees in successful epidural placement in difficult cases.</abstract><cop>Netherlands</cop><pub>Elsevier Ltd</pub><pmid>29914784</pmid><doi>10.1016/j.ijoa.2018.04.008</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0959-289X
ispartof International journal of obstetric anesthesia, 2018-11, Vol.36, p.28-33
issn 0959-289X
1532-3374
language eng
recordid cdi_proquest_miscellaneous_2057139546
source MEDLINE; ScienceDirect Journals (5 years ago - present)
subjects Adult
Analgesia, Epidural - instrumentation
Analgesia, Epidural - methods
Analgesia, Obstetrical - instrumentation
Analgesia, Obstetrical - methods
Epidural Space
Epidural technique
Female
Humans
Labor analgesia
Labor, Obstetric
Loss-of-resistance device
Needles
Pregnancy
Prospective Studies
Reproducibility of Results
title Experimental validation of the CompuFlo® epidural controlled system to identify the epidural space and its clinical use in difficult obstetric cases
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T23%3A17%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Experimental%20validation%20of%20the%20CompuFlo%C2%AE%20epidural%20controlled%20system%20to%20identify%20the%20epidural%20space%20and%20its%20clinical%20use%20in%20difficult%20obstetric%20cases&rft.jtitle=International%20journal%20of%20obstetric%20anesthesia&rft.au=Capogna,%20G.&rft.date=2018-11&rft.volume=36&rft.spage=28&rft.epage=33&rft.pages=28-33&rft.issn=0959-289X&rft.eissn=1532-3374&rft_id=info:doi/10.1016/j.ijoa.2018.04.008&rft_dat=%3Cproquest_cross%3E2057139546%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2057139546&rft_id=info:pmid/29914784&rft_els_id=S0959289X18300050&rfr_iscdi=true