Development and validation of an anion-exchange LC-UV method for the quantification and purity determination of the DNA plasmid pDERMATT
The pDERMATT (plasmid DNA encoding recombinant MART-1 and tetanus toxin fragment-c) plasmid is a novel in-house developed anti-cancer vaccine which encodes a melanoma associated epitope (Mart-1) and an immuno stimulatory sequence (tetanus toxin fragment-c). The pharmaceutical development of pDERMATT...
Gespeichert in:
Veröffentlicht in: | Journal of pharmaceutical and biomedical analysis 2009-02, Vol.49 (2), p.282-288 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The pDERMATT (plasmid DNA encoding recombinant MART-1 and tetanus toxin fragment-c) plasmid is a novel in-house developed anti-cancer vaccine which encodes a melanoma associated epitope (Mart-1) and an immuno stimulatory sequence (tetanus toxin fragment-c). The pharmaceutical development of pDERMATT necessitated the availability of an assay for the quantification and purity determination of pDERMATT active pharmaceutical ingredient (API), the produced bulk drug and its pharmaceutical dosage form. An anion-exchange liquid chromatographic method (AEX-LC) with ultraviolet (UV) detection was developed, which is based on separation on a non porous anion-exchange (NPR AEX) column with a mobile phase gradient of 0.45–0.53
M NaCl in 20
mM Tris–HCl 10% isopropanol (IPA) pH 9 and UV detection at 260 and 280
nm. The method was found to be precise, accurate and linear over a concentration range of 5–150
μg/ml. The supercoiled topoisoform of pDERMATT was well separated from the linear and open-circular form, the main degradation products formed during stress testing, confirming its stability-indicating capability. The use of photo diode array (PDA) detection enabled us to confirm all visible peaks to contain DNA. Additionally capillary gel electrophoresis (CGE) showed the same peak profile as the developed HPLC method. The developed LC-UV method will be used for the pharmaceutical quality control of pDERMATT API, bulk drug and its pharmaceutical dosage form. |
---|---|
ISSN: | 0731-7085 1873-264X |
DOI: | 10.1016/j.jpba.2008.11.011 |