A Flow-Through Sampler for Semivolatile Organic Compounds in Air
A widely acknowledged limitation of current passive air sampling designs for semivolatile organic chemicals is their relatively low sampling rate, severely constraining the temporal resolution that can be achieved. Addressing the need for an improved sampling design which achieves significantly fast...
Gespeichert in:
Veröffentlicht in: | Environmental science & technology 2007-01, Vol.41 (1), p.250-256 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 256 |
---|---|
container_issue | 1 |
container_start_page | 250 |
container_title | Environmental science & technology |
container_volume | 41 |
creator | Xiao, Hang Hung, Hayley Harner, Tom Lei, Ying D Johnston, Gordon W Wania, Frank |
description | A widely acknowledged limitation of current passive air sampling designs for semivolatile organic chemicals is their relatively low sampling rate, severely constraining the temporal resolution that can be achieved. Addressing the need for an improved sampling design which achieves significantly faster uptake while maintaining the capability of providing quantitative information, a new sampler has been developed that provides greatly increased sampling rates by forcing the wind to blow through the sampling medium. The sampler consists of a horizontally oriented, aerodynamically shaped, stainless steel flow tube mounted on a post with ball bearings, which turns into the wind with the help of vanes. A series of polyurethane foam (PUF) discs with relatively large porosity mounted inside the flow tube serve as the sampling medium. The sampled air volume is calculated from wind speed, which is measured outside the sampler and after passage through the sampling medium using precalibrated vortex rotor and turbine anemometers mounted on top of the sampler and at the exit of the flow tube, respectively. Small battery-operated data loggers are used for data storage. Under typical wind speed conditions, the sampler can collect 100 m3/day, which is approaching the sampling rates of conventional high volume samplers. Controlled experiments in the laboratory and frontal chromatography theory yield the theoretical plate number and breakthrough volumes for polychlorinated biphenyls and polycyclic aromatic hydrocarbons in the PUF plugs and allow for the estimation of breakthrough levels for relatively volatile organic chemicals. After correction for breakthrough, the air concentration obtained with the new flow-through sampler are independent of sampling length and volume and compare favorably with those obtained from conventional pumped high volume samples. |
doi_str_mv | 10.1021/es062024x |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_20504246</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>20504246</sourcerecordid><originalsourceid>FETCH-LOGICAL-a536t-9fae86148c4be192e1c85bebb4dea4250f7af4b1e6948b3988a7a5067b3993313</originalsourceid><addsrcrecordid>eNqF0V1v0zAUBmALgVg3uOAPoAgJJC4Cx59x7laVrSAVhtTycWedpCebRxIXu4Hx78nUakVwwZUt-dErn_cw9oTDKw6Cv6YERoBQN_fYhGsBubaa32cTAC7zUpqvR-w4pWsAEBLsQ3bEC2F0qfWEnU6z8zb8zFdXMQyXV9kSu01LMWtCzJbU-R-hxa1vKbuIl9j7OpuFbhOGfp0y32dTHx-xBw22iR7vzxP26fxsNXubLy7m72bTRY5amm1eNkjWcGVrVREvBfHa6oqqSq0JldDQFNioipMpla1kaS0WqMEU472UkssT9mKXu4nh-0Bp6zqfampb7CkMyQnQoIQy_4VcFaU2Fkb47C94HYbYj0O4sSYuCyvtiF7uUB1DSpEat4m-w_jLcXC35bu78kf7dB84VB2tD3Lf9gie7wGmGtsmYl_7dHBWiXFltyPkO-fTlm7u3jF-c6aQhXarj0v3_s3885f54oP7IxfrdBji3w_-BselpOg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>230137838</pqid></control><display><type>article</type><title>A Flow-Through Sampler for Semivolatile Organic Compounds in Air</title><source>MEDLINE</source><source>American Chemical Society Publications</source><creator>Xiao, Hang ; Hung, Hayley ; Harner, Tom ; Lei, Ying D ; Johnston, Gordon W ; Wania, Frank</creator><creatorcontrib>Xiao, Hang ; Hung, Hayley ; Harner, Tom ; Lei, Ying D ; Johnston, Gordon W ; Wania, Frank</creatorcontrib><description>A widely acknowledged limitation of current passive air sampling designs for semivolatile organic chemicals is their relatively low sampling rate, severely constraining the temporal resolution that can be achieved. Addressing the need for an improved sampling design which achieves significantly faster uptake while maintaining the capability of providing quantitative information, a new sampler has been developed that provides greatly increased sampling rates by forcing the wind to blow through the sampling medium. The sampler consists of a horizontally oriented, aerodynamically shaped, stainless steel flow tube mounted on a post with ball bearings, which turns into the wind with the help of vanes. A series of polyurethane foam (PUF) discs with relatively large porosity mounted inside the flow tube serve as the sampling medium. The sampled air volume is calculated from wind speed, which is measured outside the sampler and after passage through the sampling medium using precalibrated vortex rotor and turbine anemometers mounted on top of the sampler and at the exit of the flow tube, respectively. Small battery-operated data loggers are used for data storage. Under typical wind speed conditions, the sampler can collect 100 m3/day, which is approaching the sampling rates of conventional high volume samplers. Controlled experiments in the laboratory and frontal chromatography theory yield the theoretical plate number and breakthrough volumes for polychlorinated biphenyls and polycyclic aromatic hydrocarbons in the PUF plugs and allow for the estimation of breakthrough levels for relatively volatile organic chemicals. After correction for breakthrough, the air concentration obtained with the new flow-through sampler are independent of sampling length and volume and compare favorably with those obtained from conventional pumped high volume samples.</description><identifier>ISSN: 0013-936X</identifier><identifier>EISSN: 1520-5851</identifier><identifier>DOI: 10.1021/es062024x</identifier><identifier>PMID: 17265955</identifier><identifier>CODEN: ESTHAG</identifier><language>eng</language><publisher>Washington, DC: American Chemical Society</publisher><subject>Air Movements ; Air Pollutants - analysis ; Air pollution ; Analysis methods ; Applied sciences ; Atmospheric pollution ; Chemistry Techniques, Analytical - instrumentation ; Chromatography, Gas - methods ; Environmental Monitoring - instrumentation ; Exact sciences and technology ; Organic chemicals ; Organic Chemicals - analysis ; Outdoor air quality ; PCB ; Pollution ; Polychlorinated biphenyls ; Sampling techniques ; Scientific apparatus & instruments ; VOCs ; Volatile organic compounds</subject><ispartof>Environmental science & technology, 2007-01, Vol.41 (1), p.250-256</ispartof><rights>Copyright © 2007 American Chemical Society</rights><rights>2007 INIST-CNRS</rights><rights>Copyright American Chemical Society Jan 1, 2007</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a536t-9fae86148c4be192e1c85bebb4dea4250f7af4b1e6948b3988a7a5067b3993313</citedby><cites>FETCH-LOGICAL-a536t-9fae86148c4be192e1c85bebb4dea4250f7af4b1e6948b3988a7a5067b3993313</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://pubs.acs.org/doi/pdf/10.1021/es062024x$$EPDF$$P50$$Gacs$$H</linktopdf><linktohtml>$$Uhttps://pubs.acs.org/doi/10.1021/es062024x$$EHTML$$P50$$Gacs$$H</linktohtml><link.rule.ids>314,776,780,2752,27053,27901,27902,56713,56763</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=18420016$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17265955$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Xiao, Hang</creatorcontrib><creatorcontrib>Hung, Hayley</creatorcontrib><creatorcontrib>Harner, Tom</creatorcontrib><creatorcontrib>Lei, Ying D</creatorcontrib><creatorcontrib>Johnston, Gordon W</creatorcontrib><creatorcontrib>Wania, Frank</creatorcontrib><title>A Flow-Through Sampler for Semivolatile Organic Compounds in Air</title><title>Environmental science & technology</title><addtitle>Environ. Sci. Technol</addtitle><description>A widely acknowledged limitation of current passive air sampling designs for semivolatile organic chemicals is their relatively low sampling rate, severely constraining the temporal resolution that can be achieved. Addressing the need for an improved sampling design which achieves significantly faster uptake while maintaining the capability of providing quantitative information, a new sampler has been developed that provides greatly increased sampling rates by forcing the wind to blow through the sampling medium. The sampler consists of a horizontally oriented, aerodynamically shaped, stainless steel flow tube mounted on a post with ball bearings, which turns into the wind with the help of vanes. A series of polyurethane foam (PUF) discs with relatively large porosity mounted inside the flow tube serve as the sampling medium. The sampled air volume is calculated from wind speed, which is measured outside the sampler and after passage through the sampling medium using precalibrated vortex rotor and turbine anemometers mounted on top of the sampler and at the exit of the flow tube, respectively. Small battery-operated data loggers are used for data storage. Under typical wind speed conditions, the sampler can collect 100 m3/day, which is approaching the sampling rates of conventional high volume samplers. Controlled experiments in the laboratory and frontal chromatography theory yield the theoretical plate number and breakthrough volumes for polychlorinated biphenyls and polycyclic aromatic hydrocarbons in the PUF plugs and allow for the estimation of breakthrough levels for relatively volatile organic chemicals. After correction for breakthrough, the air concentration obtained with the new flow-through sampler are independent of sampling length and volume and compare favorably with those obtained from conventional pumped high volume samples.</description><subject>Air Movements</subject><subject>Air Pollutants - analysis</subject><subject>Air pollution</subject><subject>Analysis methods</subject><subject>Applied sciences</subject><subject>Atmospheric pollution</subject><subject>Chemistry Techniques, Analytical - instrumentation</subject><subject>Chromatography, Gas - methods</subject><subject>Environmental Monitoring - instrumentation</subject><subject>Exact sciences and technology</subject><subject>Organic chemicals</subject><subject>Organic Chemicals - analysis</subject><subject>Outdoor air quality</subject><subject>PCB</subject><subject>Pollution</subject><subject>Polychlorinated biphenyls</subject><subject>Sampling techniques</subject><subject>Scientific apparatus & instruments</subject><subject>VOCs</subject><subject>Volatile organic compounds</subject><issn>0013-936X</issn><issn>1520-5851</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqF0V1v0zAUBmALgVg3uOAPoAgJJC4Cx59x7laVrSAVhtTycWedpCebRxIXu4Hx78nUakVwwZUt-dErn_cw9oTDKw6Cv6YERoBQN_fYhGsBubaa32cTAC7zUpqvR-w4pWsAEBLsQ3bEC2F0qfWEnU6z8zb8zFdXMQyXV9kSu01LMWtCzJbU-R-hxa1vKbuIl9j7OpuFbhOGfp0y32dTHx-xBw22iR7vzxP26fxsNXubLy7m72bTRY5amm1eNkjWcGVrVREvBfHa6oqqSq0JldDQFNioipMpla1kaS0WqMEU472UkssT9mKXu4nh-0Bp6zqfampb7CkMyQnQoIQy_4VcFaU2Fkb47C94HYbYj0O4sSYuCyvtiF7uUB1DSpEat4m-w_jLcXC35bu78kf7dB84VB2tD3Lf9gie7wGmGtsmYl_7dHBWiXFltyPkO-fTlm7u3jF-c6aQhXarj0v3_s3885f54oP7IxfrdBji3w_-BselpOg</recordid><startdate>20070101</startdate><enddate>20070101</enddate><creator>Xiao, Hang</creator><creator>Hung, Hayley</creator><creator>Harner, Tom</creator><creator>Lei, Ying D</creator><creator>Johnston, Gordon W</creator><creator>Wania, Frank</creator><general>American Chemical Society</general><scope>BSCLL</scope><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>7ST</scope><scope>7T7</scope><scope>7U7</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>P64</scope><scope>SOI</scope><scope>7TV</scope></search><sort><creationdate>20070101</creationdate><title>A Flow-Through Sampler for Semivolatile Organic Compounds in Air</title><author>Xiao, Hang ; Hung, Hayley ; Harner, Tom ; Lei, Ying D ; Johnston, Gordon W ; Wania, Frank</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a536t-9fae86148c4be192e1c85bebb4dea4250f7af4b1e6948b3988a7a5067b3993313</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Air Movements</topic><topic>Air Pollutants - analysis</topic><topic>Air pollution</topic><topic>Analysis methods</topic><topic>Applied sciences</topic><topic>Atmospheric pollution</topic><topic>Chemistry Techniques, Analytical - instrumentation</topic><topic>Chromatography, Gas - methods</topic><topic>Environmental Monitoring - instrumentation</topic><topic>Exact sciences and technology</topic><topic>Organic chemicals</topic><topic>Organic Chemicals - analysis</topic><topic>Outdoor air quality</topic><topic>PCB</topic><topic>Pollution</topic><topic>Polychlorinated biphenyls</topic><topic>Sampling techniques</topic><topic>Scientific apparatus & instruments</topic><topic>VOCs</topic><topic>Volatile organic compounds</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Xiao, Hang</creatorcontrib><creatorcontrib>Hung, Hayley</creatorcontrib><creatorcontrib>Harner, Tom</creatorcontrib><creatorcontrib>Lei, Ying D</creatorcontrib><creatorcontrib>Johnston, Gordon W</creatorcontrib><creatorcontrib>Wania, Frank</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Environment Abstracts</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Toxicology Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Environment Abstracts</collection><collection>Pollution Abstracts</collection><jtitle>Environmental science & technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Xiao, Hang</au><au>Hung, Hayley</au><au>Harner, Tom</au><au>Lei, Ying D</au><au>Johnston, Gordon W</au><au>Wania, Frank</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Flow-Through Sampler for Semivolatile Organic Compounds in Air</atitle><jtitle>Environmental science & technology</jtitle><addtitle>Environ. Sci. Technol</addtitle><date>2007-01-01</date><risdate>2007</risdate><volume>41</volume><issue>1</issue><spage>250</spage><epage>256</epage><pages>250-256</pages><issn>0013-936X</issn><eissn>1520-5851</eissn><coden>ESTHAG</coden><abstract>A widely acknowledged limitation of current passive air sampling designs for semivolatile organic chemicals is their relatively low sampling rate, severely constraining the temporal resolution that can be achieved. Addressing the need for an improved sampling design which achieves significantly faster uptake while maintaining the capability of providing quantitative information, a new sampler has been developed that provides greatly increased sampling rates by forcing the wind to blow through the sampling medium. The sampler consists of a horizontally oriented, aerodynamically shaped, stainless steel flow tube mounted on a post with ball bearings, which turns into the wind with the help of vanes. A series of polyurethane foam (PUF) discs with relatively large porosity mounted inside the flow tube serve as the sampling medium. The sampled air volume is calculated from wind speed, which is measured outside the sampler and after passage through the sampling medium using precalibrated vortex rotor and turbine anemometers mounted on top of the sampler and at the exit of the flow tube, respectively. Small battery-operated data loggers are used for data storage. Under typical wind speed conditions, the sampler can collect 100 m3/day, which is approaching the sampling rates of conventional high volume samplers. Controlled experiments in the laboratory and frontal chromatography theory yield the theoretical plate number and breakthrough volumes for polychlorinated biphenyls and polycyclic aromatic hydrocarbons in the PUF plugs and allow for the estimation of breakthrough levels for relatively volatile organic chemicals. After correction for breakthrough, the air concentration obtained with the new flow-through sampler are independent of sampling length and volume and compare favorably with those obtained from conventional pumped high volume samples.</abstract><cop>Washington, DC</cop><pub>American Chemical Society</pub><pmid>17265955</pmid><doi>10.1021/es062024x</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0013-936X |
ispartof | Environmental science & technology, 2007-01, Vol.41 (1), p.250-256 |
issn | 0013-936X 1520-5851 |
language | eng |
recordid | cdi_proquest_miscellaneous_20504246 |
source | MEDLINE; American Chemical Society Publications |
subjects | Air Movements Air Pollutants - analysis Air pollution Analysis methods Applied sciences Atmospheric pollution Chemistry Techniques, Analytical - instrumentation Chromatography, Gas - methods Environmental Monitoring - instrumentation Exact sciences and technology Organic chemicals Organic Chemicals - analysis Outdoor air quality PCB Pollution Polychlorinated biphenyls Sampling techniques Scientific apparatus & instruments VOCs Volatile organic compounds |
title | A Flow-Through Sampler for Semivolatile Organic Compounds in Air |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-07T16%3A07%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Flow-Through%20Sampler%20for%20Semivolatile%20Organic%20Compounds%20in%20Air&rft.jtitle=Environmental%20science%20&%20technology&rft.au=Xiao,%20Hang&rft.date=2007-01-01&rft.volume=41&rft.issue=1&rft.spage=250&rft.epage=256&rft.pages=250-256&rft.issn=0013-936X&rft.eissn=1520-5851&rft.coden=ESTHAG&rft_id=info:doi/10.1021/es062024x&rft_dat=%3Cproquest_cross%3E20504246%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=230137838&rft_id=info:pmid/17265955&rfr_iscdi=true |