A Flow-Through Sampler for Semivolatile Organic Compounds in Air

A widely acknowledged limitation of current passive air sampling designs for semivolatile organic chemicals is their relatively low sampling rate, severely constraining the temporal resolution that can be achieved. Addressing the need for an improved sampling design which achieves significantly fast...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Environmental science & technology 2007-01, Vol.41 (1), p.250-256
Hauptverfasser: Xiao, Hang, Hung, Hayley, Harner, Tom, Lei, Ying D, Johnston, Gordon W, Wania, Frank
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 256
container_issue 1
container_start_page 250
container_title Environmental science & technology
container_volume 41
creator Xiao, Hang
Hung, Hayley
Harner, Tom
Lei, Ying D
Johnston, Gordon W
Wania, Frank
description A widely acknowledged limitation of current passive air sampling designs for semivolatile organic chemicals is their relatively low sampling rate, severely constraining the temporal resolution that can be achieved. Addressing the need for an improved sampling design which achieves significantly faster uptake while maintaining the capability of providing quantitative information, a new sampler has been developed that provides greatly increased sampling rates by forcing the wind to blow through the sampling medium. The sampler consists of a horizontally oriented, aerodynamically shaped, stainless steel flow tube mounted on a post with ball bearings, which turns into the wind with the help of vanes. A series of polyurethane foam (PUF) discs with relatively large porosity mounted inside the flow tube serve as the sampling medium. The sampled air volume is calculated from wind speed, which is measured outside the sampler and after passage through the sampling medium using precalibrated vortex rotor and turbine anemometers mounted on top of the sampler and at the exit of the flow tube, respectively. Small battery-operated data loggers are used for data storage. Under typical wind speed conditions, the sampler can collect 100 m3/day, which is approaching the sampling rates of conventional high volume samplers. Controlled experiments in the laboratory and frontal chromatography theory yield the theoretical plate number and breakthrough volumes for polychlorinated biphenyls and polycyclic aromatic hydrocarbons in the PUF plugs and allow for the estimation of breakthrough levels for relatively volatile organic chemicals. After correction for breakthrough, the air concentration obtained with the new flow-through sampler are independent of sampling length and volume and compare favorably with those obtained from conventional pumped high volume samples.
doi_str_mv 10.1021/es062024x
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_20504246</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>20504246</sourcerecordid><originalsourceid>FETCH-LOGICAL-a536t-9fae86148c4be192e1c85bebb4dea4250f7af4b1e6948b3988a7a5067b3993313</originalsourceid><addsrcrecordid>eNqF0V1v0zAUBmALgVg3uOAPoAgJJC4Cx59x7laVrSAVhtTycWedpCebRxIXu4Hx78nUakVwwZUt-dErn_cw9oTDKw6Cv6YERoBQN_fYhGsBubaa32cTAC7zUpqvR-w4pWsAEBLsQ3bEC2F0qfWEnU6z8zb8zFdXMQyXV9kSu01LMWtCzJbU-R-hxa1vKbuIl9j7OpuFbhOGfp0y32dTHx-xBw22iR7vzxP26fxsNXubLy7m72bTRY5amm1eNkjWcGVrVREvBfHa6oqqSq0JldDQFNioipMpla1kaS0WqMEU472UkssT9mKXu4nh-0Bp6zqfampb7CkMyQnQoIQy_4VcFaU2Fkb47C94HYbYj0O4sSYuCyvtiF7uUB1DSpEat4m-w_jLcXC35bu78kf7dB84VB2tD3Lf9gie7wGmGtsmYl_7dHBWiXFltyPkO-fTlm7u3jF-c6aQhXarj0v3_s3885f54oP7IxfrdBji3w_-BselpOg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>230137838</pqid></control><display><type>article</type><title>A Flow-Through Sampler for Semivolatile Organic Compounds in Air</title><source>MEDLINE</source><source>American Chemical Society Publications</source><creator>Xiao, Hang ; Hung, Hayley ; Harner, Tom ; Lei, Ying D ; Johnston, Gordon W ; Wania, Frank</creator><creatorcontrib>Xiao, Hang ; Hung, Hayley ; Harner, Tom ; Lei, Ying D ; Johnston, Gordon W ; Wania, Frank</creatorcontrib><description>A widely acknowledged limitation of current passive air sampling designs for semivolatile organic chemicals is their relatively low sampling rate, severely constraining the temporal resolution that can be achieved. Addressing the need for an improved sampling design which achieves significantly faster uptake while maintaining the capability of providing quantitative information, a new sampler has been developed that provides greatly increased sampling rates by forcing the wind to blow through the sampling medium. The sampler consists of a horizontally oriented, aerodynamically shaped, stainless steel flow tube mounted on a post with ball bearings, which turns into the wind with the help of vanes. A series of polyurethane foam (PUF) discs with relatively large porosity mounted inside the flow tube serve as the sampling medium. The sampled air volume is calculated from wind speed, which is measured outside the sampler and after passage through the sampling medium using precalibrated vortex rotor and turbine anemometers mounted on top of the sampler and at the exit of the flow tube, respectively. Small battery-operated data loggers are used for data storage. Under typical wind speed conditions, the sampler can collect 100 m3/day, which is approaching the sampling rates of conventional high volume samplers. Controlled experiments in the laboratory and frontal chromatography theory yield the theoretical plate number and breakthrough volumes for polychlorinated biphenyls and polycyclic aromatic hydrocarbons in the PUF plugs and allow for the estimation of breakthrough levels for relatively volatile organic chemicals. After correction for breakthrough, the air concentration obtained with the new flow-through sampler are independent of sampling length and volume and compare favorably with those obtained from conventional pumped high volume samples.</description><identifier>ISSN: 0013-936X</identifier><identifier>EISSN: 1520-5851</identifier><identifier>DOI: 10.1021/es062024x</identifier><identifier>PMID: 17265955</identifier><identifier>CODEN: ESTHAG</identifier><language>eng</language><publisher>Washington, DC: American Chemical Society</publisher><subject>Air Movements ; Air Pollutants - analysis ; Air pollution ; Analysis methods ; Applied sciences ; Atmospheric pollution ; Chemistry Techniques, Analytical - instrumentation ; Chromatography, Gas - methods ; Environmental Monitoring - instrumentation ; Exact sciences and technology ; Organic chemicals ; Organic Chemicals - analysis ; Outdoor air quality ; PCB ; Pollution ; Polychlorinated biphenyls ; Sampling techniques ; Scientific apparatus &amp; instruments ; VOCs ; Volatile organic compounds</subject><ispartof>Environmental science &amp; technology, 2007-01, Vol.41 (1), p.250-256</ispartof><rights>Copyright © 2007 American Chemical Society</rights><rights>2007 INIST-CNRS</rights><rights>Copyright American Chemical Society Jan 1, 2007</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a536t-9fae86148c4be192e1c85bebb4dea4250f7af4b1e6948b3988a7a5067b3993313</citedby><cites>FETCH-LOGICAL-a536t-9fae86148c4be192e1c85bebb4dea4250f7af4b1e6948b3988a7a5067b3993313</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://pubs.acs.org/doi/pdf/10.1021/es062024x$$EPDF$$P50$$Gacs$$H</linktopdf><linktohtml>$$Uhttps://pubs.acs.org/doi/10.1021/es062024x$$EHTML$$P50$$Gacs$$H</linktohtml><link.rule.ids>314,776,780,2752,27053,27901,27902,56713,56763</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=18420016$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17265955$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Xiao, Hang</creatorcontrib><creatorcontrib>Hung, Hayley</creatorcontrib><creatorcontrib>Harner, Tom</creatorcontrib><creatorcontrib>Lei, Ying D</creatorcontrib><creatorcontrib>Johnston, Gordon W</creatorcontrib><creatorcontrib>Wania, Frank</creatorcontrib><title>A Flow-Through Sampler for Semivolatile Organic Compounds in Air</title><title>Environmental science &amp; technology</title><addtitle>Environ. Sci. Technol</addtitle><description>A widely acknowledged limitation of current passive air sampling designs for semivolatile organic chemicals is their relatively low sampling rate, severely constraining the temporal resolution that can be achieved. Addressing the need for an improved sampling design which achieves significantly faster uptake while maintaining the capability of providing quantitative information, a new sampler has been developed that provides greatly increased sampling rates by forcing the wind to blow through the sampling medium. The sampler consists of a horizontally oriented, aerodynamically shaped, stainless steel flow tube mounted on a post with ball bearings, which turns into the wind with the help of vanes. A series of polyurethane foam (PUF) discs with relatively large porosity mounted inside the flow tube serve as the sampling medium. The sampled air volume is calculated from wind speed, which is measured outside the sampler and after passage through the sampling medium using precalibrated vortex rotor and turbine anemometers mounted on top of the sampler and at the exit of the flow tube, respectively. Small battery-operated data loggers are used for data storage. Under typical wind speed conditions, the sampler can collect 100 m3/day, which is approaching the sampling rates of conventional high volume samplers. Controlled experiments in the laboratory and frontal chromatography theory yield the theoretical plate number and breakthrough volumes for polychlorinated biphenyls and polycyclic aromatic hydrocarbons in the PUF plugs and allow for the estimation of breakthrough levels for relatively volatile organic chemicals. After correction for breakthrough, the air concentration obtained with the new flow-through sampler are independent of sampling length and volume and compare favorably with those obtained from conventional pumped high volume samples.</description><subject>Air Movements</subject><subject>Air Pollutants - analysis</subject><subject>Air pollution</subject><subject>Analysis methods</subject><subject>Applied sciences</subject><subject>Atmospheric pollution</subject><subject>Chemistry Techniques, Analytical - instrumentation</subject><subject>Chromatography, Gas - methods</subject><subject>Environmental Monitoring - instrumentation</subject><subject>Exact sciences and technology</subject><subject>Organic chemicals</subject><subject>Organic Chemicals - analysis</subject><subject>Outdoor air quality</subject><subject>PCB</subject><subject>Pollution</subject><subject>Polychlorinated biphenyls</subject><subject>Sampling techniques</subject><subject>Scientific apparatus &amp; instruments</subject><subject>VOCs</subject><subject>Volatile organic compounds</subject><issn>0013-936X</issn><issn>1520-5851</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqF0V1v0zAUBmALgVg3uOAPoAgJJC4Cx59x7laVrSAVhtTycWedpCebRxIXu4Hx78nUakVwwZUt-dErn_cw9oTDKw6Cv6YERoBQN_fYhGsBubaa32cTAC7zUpqvR-w4pWsAEBLsQ3bEC2F0qfWEnU6z8zb8zFdXMQyXV9kSu01LMWtCzJbU-R-hxa1vKbuIl9j7OpuFbhOGfp0y32dTHx-xBw22iR7vzxP26fxsNXubLy7m72bTRY5amm1eNkjWcGVrVREvBfHa6oqqSq0JldDQFNioipMpla1kaS0WqMEU472UkssT9mKXu4nh-0Bp6zqfampb7CkMyQnQoIQy_4VcFaU2Fkb47C94HYbYj0O4sSYuCyvtiF7uUB1DSpEat4m-w_jLcXC35bu78kf7dB84VB2tD3Lf9gie7wGmGtsmYl_7dHBWiXFltyPkO-fTlm7u3jF-c6aQhXarj0v3_s3885f54oP7IxfrdBji3w_-BselpOg</recordid><startdate>20070101</startdate><enddate>20070101</enddate><creator>Xiao, Hang</creator><creator>Hung, Hayley</creator><creator>Harner, Tom</creator><creator>Lei, Ying D</creator><creator>Johnston, Gordon W</creator><creator>Wania, Frank</creator><general>American Chemical Society</general><scope>BSCLL</scope><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>7ST</scope><scope>7T7</scope><scope>7U7</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>P64</scope><scope>SOI</scope><scope>7TV</scope></search><sort><creationdate>20070101</creationdate><title>A Flow-Through Sampler for Semivolatile Organic Compounds in Air</title><author>Xiao, Hang ; Hung, Hayley ; Harner, Tom ; Lei, Ying D ; Johnston, Gordon W ; Wania, Frank</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a536t-9fae86148c4be192e1c85bebb4dea4250f7af4b1e6948b3988a7a5067b3993313</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Air Movements</topic><topic>Air Pollutants - analysis</topic><topic>Air pollution</topic><topic>Analysis methods</topic><topic>Applied sciences</topic><topic>Atmospheric pollution</topic><topic>Chemistry Techniques, Analytical - instrumentation</topic><topic>Chromatography, Gas - methods</topic><topic>Environmental Monitoring - instrumentation</topic><topic>Exact sciences and technology</topic><topic>Organic chemicals</topic><topic>Organic Chemicals - analysis</topic><topic>Outdoor air quality</topic><topic>PCB</topic><topic>Pollution</topic><topic>Polychlorinated biphenyls</topic><topic>Sampling techniques</topic><topic>Scientific apparatus &amp; instruments</topic><topic>VOCs</topic><topic>Volatile organic compounds</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Xiao, Hang</creatorcontrib><creatorcontrib>Hung, Hayley</creatorcontrib><creatorcontrib>Harner, Tom</creatorcontrib><creatorcontrib>Lei, Ying D</creatorcontrib><creatorcontrib>Johnston, Gordon W</creatorcontrib><creatorcontrib>Wania, Frank</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Environment Abstracts</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Toxicology Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Environment Abstracts</collection><collection>Pollution Abstracts</collection><jtitle>Environmental science &amp; technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Xiao, Hang</au><au>Hung, Hayley</au><au>Harner, Tom</au><au>Lei, Ying D</au><au>Johnston, Gordon W</au><au>Wania, Frank</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Flow-Through Sampler for Semivolatile Organic Compounds in Air</atitle><jtitle>Environmental science &amp; technology</jtitle><addtitle>Environ. Sci. Technol</addtitle><date>2007-01-01</date><risdate>2007</risdate><volume>41</volume><issue>1</issue><spage>250</spage><epage>256</epage><pages>250-256</pages><issn>0013-936X</issn><eissn>1520-5851</eissn><coden>ESTHAG</coden><abstract>A widely acknowledged limitation of current passive air sampling designs for semivolatile organic chemicals is their relatively low sampling rate, severely constraining the temporal resolution that can be achieved. Addressing the need for an improved sampling design which achieves significantly faster uptake while maintaining the capability of providing quantitative information, a new sampler has been developed that provides greatly increased sampling rates by forcing the wind to blow through the sampling medium. The sampler consists of a horizontally oriented, aerodynamically shaped, stainless steel flow tube mounted on a post with ball bearings, which turns into the wind with the help of vanes. A series of polyurethane foam (PUF) discs with relatively large porosity mounted inside the flow tube serve as the sampling medium. The sampled air volume is calculated from wind speed, which is measured outside the sampler and after passage through the sampling medium using precalibrated vortex rotor and turbine anemometers mounted on top of the sampler and at the exit of the flow tube, respectively. Small battery-operated data loggers are used for data storage. Under typical wind speed conditions, the sampler can collect 100 m3/day, which is approaching the sampling rates of conventional high volume samplers. Controlled experiments in the laboratory and frontal chromatography theory yield the theoretical plate number and breakthrough volumes for polychlorinated biphenyls and polycyclic aromatic hydrocarbons in the PUF plugs and allow for the estimation of breakthrough levels for relatively volatile organic chemicals. After correction for breakthrough, the air concentration obtained with the new flow-through sampler are independent of sampling length and volume and compare favorably with those obtained from conventional pumped high volume samples.</abstract><cop>Washington, DC</cop><pub>American Chemical Society</pub><pmid>17265955</pmid><doi>10.1021/es062024x</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0013-936X
ispartof Environmental science & technology, 2007-01, Vol.41 (1), p.250-256
issn 0013-936X
1520-5851
language eng
recordid cdi_proquest_miscellaneous_20504246
source MEDLINE; American Chemical Society Publications
subjects Air Movements
Air Pollutants - analysis
Air pollution
Analysis methods
Applied sciences
Atmospheric pollution
Chemistry Techniques, Analytical - instrumentation
Chromatography, Gas - methods
Environmental Monitoring - instrumentation
Exact sciences and technology
Organic chemicals
Organic Chemicals - analysis
Outdoor air quality
PCB
Pollution
Polychlorinated biphenyls
Sampling techniques
Scientific apparatus & instruments
VOCs
Volatile organic compounds
title A Flow-Through Sampler for Semivolatile Organic Compounds in Air
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-07T16%3A07%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Flow-Through%20Sampler%20for%20Semivolatile%20Organic%20Compounds%20in%20Air&rft.jtitle=Environmental%20science%20&%20technology&rft.au=Xiao,%20Hang&rft.date=2007-01-01&rft.volume=41&rft.issue=1&rft.spage=250&rft.epage=256&rft.pages=250-256&rft.issn=0013-936X&rft.eissn=1520-5851&rft.coden=ESTHAG&rft_id=info:doi/10.1021/es062024x&rft_dat=%3Cproquest_cross%3E20504246%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=230137838&rft_id=info:pmid/17265955&rfr_iscdi=true