An unusual complication after placement of an inferior vena cava filter via right internal jugular vein access

Introduction: Totally implantable venous access devices are used extensively worldwide in cancer patients for administration of venotoxic agents, blood sampling, and nutrition. Their tip is usually positioned at the junction of superior vena cava and right atrium. Inferior vena cava filters are usua...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The journal of vascular access 2019-01, Vol.20 (1), p.102-104
Hauptverfasser: Nas, Hala, Bowe, Dedrick, Soubani, Ayman O
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 104
container_issue 1
container_start_page 102
container_title The journal of vascular access
container_volume 20
creator Nas, Hala
Bowe, Dedrick
Soubani, Ayman O
description Introduction: Totally implantable venous access devices are used extensively worldwide in cancer patients for administration of venotoxic agents, blood sampling, and nutrition. Their tip is usually positioned at the junction of superior vena cava and right atrium. Inferior vena cava filters are usually used for deep venous thrombosis in cases where anticoagulation is contraindicated; they can be inserted either via internal jugular or femoral access depending on patient conditions and preference. Case description: We are describing here a case of totally implantable venous access device fracture following a right internal jugular approach for inferior vena cava filter placement as the patient had inferior vena cava thrombus below the renal veins, extending into the right common iliac vein prohibiting femoral approach. Conclusion: Iatrogenic fracture of totally implantable venous access device is a potential complication of accessing the internal jugular vein for other procedures such as insertion of inferior vena cava filter.
doi_str_mv 10.1177/1129729818777967
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2049557458</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1129729818777967</sage_id><sourcerecordid>2049557458</sourcerecordid><originalsourceid>FETCH-LOGICAL-c337t-725e9d8cbf9e532b70f1c93c6ce8f4b0e176be55a8c88a590fc2a8826f1a2ea03</originalsourceid><addsrcrecordid>eNp1kE1L7TAQhoMofu_v6pLl3VSTtGmSpYhfILjRdZnGyTGHNj0mzQH_vSlHXVxwNZnMMw_DS8gfzi44V-qSc2GUMJprpZRp1R455ko0VctqsV_eZVwt8yNyktKaMWEkbw7JUfmSUnB5TMJVoDnklGGgdho3g7cw-ylQcDNGuhnA4ohhppOjEKgPDqOfIt1iAGphC9T5YSG3Hmj0q7e5MKUPxbfOqzzAwvrisxZTOiMHDoaE51_1lLzc3jxf31ePT3cP11ePla1rNZebJZpXbXtnUNaiV8xxa2rbWtSu6Rly1fYoJWirNUjDnBWgtWgdB4HA6lPyb-fdxOk9Y5q70SeLwwABp5w6wRojpWqkLijboTZOKUV03Sb6EeJHx1m3pNz9n3JZ-ftlz_2Irz8L37EWoNoBCVbYrae85JF-F34C5fuGTQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2049557458</pqid></control><display><type>article</type><title>An unusual complication after placement of an inferior vena cava filter via right internal jugular vein access</title><source>SAGE Complete A-Z List</source><creator>Nas, Hala ; Bowe, Dedrick ; Soubani, Ayman O</creator><creatorcontrib>Nas, Hala ; Bowe, Dedrick ; Soubani, Ayman O</creatorcontrib><description>Introduction: Totally implantable venous access devices are used extensively worldwide in cancer patients for administration of venotoxic agents, blood sampling, and nutrition. Their tip is usually positioned at the junction of superior vena cava and right atrium. Inferior vena cava filters are usually used for deep venous thrombosis in cases where anticoagulation is contraindicated; they can be inserted either via internal jugular or femoral access depending on patient conditions and preference. Case description: We are describing here a case of totally implantable venous access device fracture following a right internal jugular approach for inferior vena cava filter placement as the patient had inferior vena cava thrombus below the renal veins, extending into the right common iliac vein prohibiting femoral approach. Conclusion: Iatrogenic fracture of totally implantable venous access device is a potential complication of accessing the internal jugular vein for other procedures such as insertion of inferior vena cava filter.</description><identifier>ISSN: 1129-7298</identifier><identifier>EISSN: 1724-6032</identifier><identifier>DOI: 10.1177/1129729818777967</identifier><identifier>PMID: 29855215</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><ispartof>The journal of vascular access, 2019-01, Vol.20 (1), p.102-104</ispartof><rights>The Author(s) 2018</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c337t-725e9d8cbf9e532b70f1c93c6ce8f4b0e176be55a8c88a590fc2a8826f1a2ea03</citedby><cites>FETCH-LOGICAL-c337t-725e9d8cbf9e532b70f1c93c6ce8f4b0e176be55a8c88a590fc2a8826f1a2ea03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/1129729818777967$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/1129729818777967$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,777,781,21800,27905,27906,43602,43603</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29855215$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Nas, Hala</creatorcontrib><creatorcontrib>Bowe, Dedrick</creatorcontrib><creatorcontrib>Soubani, Ayman O</creatorcontrib><title>An unusual complication after placement of an inferior vena cava filter via right internal jugular vein access</title><title>The journal of vascular access</title><addtitle>J Vasc Access</addtitle><description>Introduction: Totally implantable venous access devices are used extensively worldwide in cancer patients for administration of venotoxic agents, blood sampling, and nutrition. Their tip is usually positioned at the junction of superior vena cava and right atrium. Inferior vena cava filters are usually used for deep venous thrombosis in cases where anticoagulation is contraindicated; they can be inserted either via internal jugular or femoral access depending on patient conditions and preference. Case description: We are describing here a case of totally implantable venous access device fracture following a right internal jugular approach for inferior vena cava filter placement as the patient had inferior vena cava thrombus below the renal veins, extending into the right common iliac vein prohibiting femoral approach. Conclusion: Iatrogenic fracture of totally implantable venous access device is a potential complication of accessing the internal jugular vein for other procedures such as insertion of inferior vena cava filter.</description><issn>1129-7298</issn><issn>1724-6032</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp1kE1L7TAQhoMofu_v6pLl3VSTtGmSpYhfILjRdZnGyTGHNj0mzQH_vSlHXVxwNZnMMw_DS8gfzi44V-qSc2GUMJprpZRp1R455ko0VctqsV_eZVwt8yNyktKaMWEkbw7JUfmSUnB5TMJVoDnklGGgdho3g7cw-ylQcDNGuhnA4ohhppOjEKgPDqOfIt1iAGphC9T5YSG3Hmj0q7e5MKUPxbfOqzzAwvrisxZTOiMHDoaE51_1lLzc3jxf31ePT3cP11ePla1rNZebJZpXbXtnUNaiV8xxa2rbWtSu6Rly1fYoJWirNUjDnBWgtWgdB4HA6lPyb-fdxOk9Y5q70SeLwwABp5w6wRojpWqkLijboTZOKUV03Sb6EeJHx1m3pNz9n3JZ-ftlz_2Irz8L37EWoNoBCVbYrae85JF-F34C5fuGTQ</recordid><startdate>201901</startdate><enddate>201901</enddate><creator>Nas, Hala</creator><creator>Bowe, Dedrick</creator><creator>Soubani, Ayman O</creator><general>SAGE Publications</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201901</creationdate><title>An unusual complication after placement of an inferior vena cava filter via right internal jugular vein access</title><author>Nas, Hala ; Bowe, Dedrick ; Soubani, Ayman O</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c337t-725e9d8cbf9e532b70f1c93c6ce8f4b0e176be55a8c88a590fc2a8826f1a2ea03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nas, Hala</creatorcontrib><creatorcontrib>Bowe, Dedrick</creatorcontrib><creatorcontrib>Soubani, Ayman O</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The journal of vascular access</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nas, Hala</au><au>Bowe, Dedrick</au><au>Soubani, Ayman O</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An unusual complication after placement of an inferior vena cava filter via right internal jugular vein access</atitle><jtitle>The journal of vascular access</jtitle><addtitle>J Vasc Access</addtitle><date>2019-01</date><risdate>2019</risdate><volume>20</volume><issue>1</issue><spage>102</spage><epage>104</epage><pages>102-104</pages><issn>1129-7298</issn><eissn>1724-6032</eissn><abstract>Introduction: Totally implantable venous access devices are used extensively worldwide in cancer patients for administration of venotoxic agents, blood sampling, and nutrition. Their tip is usually positioned at the junction of superior vena cava and right atrium. Inferior vena cava filters are usually used for deep venous thrombosis in cases where anticoagulation is contraindicated; they can be inserted either via internal jugular or femoral access depending on patient conditions and preference. Case description: We are describing here a case of totally implantable venous access device fracture following a right internal jugular approach for inferior vena cava filter placement as the patient had inferior vena cava thrombus below the renal veins, extending into the right common iliac vein prohibiting femoral approach. Conclusion: Iatrogenic fracture of totally implantable venous access device is a potential complication of accessing the internal jugular vein for other procedures such as insertion of inferior vena cava filter.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><pmid>29855215</pmid><doi>10.1177/1129729818777967</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1129-7298
ispartof The journal of vascular access, 2019-01, Vol.20 (1), p.102-104
issn 1129-7298
1724-6032
language eng
recordid cdi_proquest_miscellaneous_2049557458
source SAGE Complete A-Z List
title An unusual complication after placement of an inferior vena cava filter via right internal jugular vein access
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-18T04%3A24%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20unusual%20complication%20after%20placement%20of%20an%20inferior%20vena%20cava%20filter%20via%20right%20internal%20jugular%20vein%20access&rft.jtitle=The%20journal%20of%20vascular%20access&rft.au=Nas,%20Hala&rft.date=2019-01&rft.volume=20&rft.issue=1&rft.spage=102&rft.epage=104&rft.pages=102-104&rft.issn=1129-7298&rft.eissn=1724-6032&rft_id=info:doi/10.1177/1129729818777967&rft_dat=%3Cproquest_cross%3E2049557458%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2049557458&rft_id=info:pmid/29855215&rft_sage_id=10.1177_1129729818777967&rfr_iscdi=true