Monitoring of Hydrogen Peroxide, Nitrate and Nitrite in Rain Water
The relationship between hydrogen peroxide and nitrate and nitrite by monitoring these substances in rain water was investigated. For the determination of hydrogen peroxide, our previously reported FIA system was applied. For the determination of nitrate and nitrite, an FIA system consisting a coppe...
Gespeichert in:
Veröffentlicht in: | Analytical Sciences 2000, Vol.16(3), pp.275-281 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 281 |
---|---|
container_issue | 3 |
container_start_page | 275 |
container_title | Analytical Sciences |
container_volume | 16 |
creator | TANIAI, Tetsuyuki SAKURAGAWA, Akio OKUTANI, Tadao |
description | The relationship between hydrogen peroxide and nitrate and nitrite by monitoring these substances in rain water was investigated. For the determination of hydrogen peroxide, our previously reported FIA system was applied. For the determination of nitrate and nitrite, an FIA system consisting a copperized cadmium reduction column and 2,3-diaminonaphthalene (DAN) used as fluorescence substance was developed. Under the recommended conditions, it took 8 min to determine the sum of nitrate and nitrite while passing through the copperized cadmium reduction column; it took 6 min under the same condition to determine nitrite without passing through the column. The concentration of nitrate was calculated from the difference between the sum of nitrate and nitrite and nitrite. The detection limit, which was defined by a signal-to-noise ratio of 3, was calculated to be 0.1 μmol dm-3 for nitrite. Also, the relative standard deviation at 20 μmol dm-3 of nitrate was under 1.0% (n = 10). There was no interference from the major substances present in rain. The reaction scheme was based on the monitoring results. |
doi_str_mv | 10.2116/analsci.16.275 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_20469907</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3117949671</sourcerecordid><originalsourceid>FETCH-LOGICAL-c577t-eeb0bdef8c534113f7aa742fd6e9ca002797d70491da4e44c40f86710577bf7b3</originalsourceid><addsrcrecordid>eNpdkN1LHDEUxYNU6FZ97fNAi0_OevOxk5lHXfwoWC1F8THczdysWcZEk1nQ_97YXWzpy82B8zsncBj7ymEqOG-OMeCQrZ_yZir0bIdNuFRtLYRqPrEJdBzqRir4zL7kvALgohViwk5_xuDHmHxYVtFVl699iksK1S9K8cX3dFRd-zHhSBWG_o_2RftQ_cZy7ouR9tmuKz_TwfbdY3fnZ7fzy_rq5uLH_OSqtjOtx5poAYueXGtnUnEunUbUSri-oc4igNCd7jWojveoSCmrwLWN5lDSC6cXco8dbnqfUnxeUx7No8-WhgEDxXU2AlTTdaAL-O0_cBXX6X0dw5VqZ1JqAYWabiibYs6JnHlK_hHTq-Fg3gc120FNkWXQEvi-rcVscXAJg_X5b0px6GRTsPkGW-URl_ThYxq9HejfVrk5pfzDtQ-YDAX5BsLwjlA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1448533720</pqid></control><display><type>article</type><title>Monitoring of Hydrogen Peroxide, Nitrate and Nitrite in Rain Water</title><source>J-STAGE Free</source><source>Springer Nature - Complete Springer Journals</source><source>Freely Accessible Japanese Titles</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Free Full-Text Journals in Chemistry</source><creator>TANIAI, Tetsuyuki ; SAKURAGAWA, Akio ; OKUTANI, Tadao</creator><creatorcontrib>TANIAI, Tetsuyuki ; SAKURAGAWA, Akio ; OKUTANI, Tadao</creatorcontrib><description>The relationship between hydrogen peroxide and nitrate and nitrite by monitoring these substances in rain water was investigated. For the determination of hydrogen peroxide, our previously reported FIA system was applied. For the determination of nitrate and nitrite, an FIA system consisting a copperized cadmium reduction column and 2,3-diaminonaphthalene (DAN) used as fluorescence substance was developed. Under the recommended conditions, it took 8 min to determine the sum of nitrate and nitrite while passing through the copperized cadmium reduction column; it took 6 min under the same condition to determine nitrite without passing through the column. The concentration of nitrate was calculated from the difference between the sum of nitrate and nitrite and nitrite. The detection limit, which was defined by a signal-to-noise ratio of 3, was calculated to be 0.1 μmol dm-3 for nitrite. Also, the relative standard deviation at 20 μmol dm-3 of nitrate was under 1.0% (n = 10). There was no interference from the major substances present in rain. The reaction scheme was based on the monitoring results.</description><identifier>ISSN: 0910-6340</identifier><identifier>EISSN: 1348-2246</identifier><identifier>DOI: 10.2116/analsci.16.275</identifier><identifier>CODEN: ANSCEN</identifier><language>eng</language><publisher>Tokyo: The Japan Society for Analytical Chemistry</publisher><subject>Analytical chemistry ; Applied sciences ; Chemistry ; Exact sciences and technology ; Natural water pollution ; Pollution ; Rainwaters, run off water and others ; Spectrometric and optical methods ; Water treatment and pollution</subject><ispartof>Analytical Sciences, 2000, Vol.16(3), pp.275-281</ispartof><rights>2000 by The Japan Society for Analytical Chemistry</rights><rights>2000 INIST-CNRS</rights><rights>Copyright Japan Science and Technology Agency 2000</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c577t-eeb0bdef8c534113f7aa742fd6e9ca002797d70491da4e44c40f86710577bf7b3</citedby><cites>FETCH-LOGICAL-c577t-eeb0bdef8c534113f7aa742fd6e9ca002797d70491da4e44c40f86710577bf7b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,1877,4010,27900,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=1410936$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>TANIAI, Tetsuyuki</creatorcontrib><creatorcontrib>SAKURAGAWA, Akio</creatorcontrib><creatorcontrib>OKUTANI, Tadao</creatorcontrib><title>Monitoring of Hydrogen Peroxide, Nitrate and Nitrite in Rain Water</title><title>Analytical Sciences</title><description>The relationship between hydrogen peroxide and nitrate and nitrite by monitoring these substances in rain water was investigated. For the determination of hydrogen peroxide, our previously reported FIA system was applied. For the determination of nitrate and nitrite, an FIA system consisting a copperized cadmium reduction column and 2,3-diaminonaphthalene (DAN) used as fluorescence substance was developed. Under the recommended conditions, it took 8 min to determine the sum of nitrate and nitrite while passing through the copperized cadmium reduction column; it took 6 min under the same condition to determine nitrite without passing through the column. The concentration of nitrate was calculated from the difference between the sum of nitrate and nitrite and nitrite. The detection limit, which was defined by a signal-to-noise ratio of 3, was calculated to be 0.1 μmol dm-3 for nitrite. Also, the relative standard deviation at 20 μmol dm-3 of nitrate was under 1.0% (n = 10). There was no interference from the major substances present in rain. The reaction scheme was based on the monitoring results.</description><subject>Analytical chemistry</subject><subject>Applied sciences</subject><subject>Chemistry</subject><subject>Exact sciences and technology</subject><subject>Natural water pollution</subject><subject>Pollution</subject><subject>Rainwaters, run off water and others</subject><subject>Spectrometric and optical methods</subject><subject>Water treatment and pollution</subject><issn>0910-6340</issn><issn>1348-2246</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><recordid>eNpdkN1LHDEUxYNU6FZ97fNAi0_OevOxk5lHXfwoWC1F8THczdysWcZEk1nQ_97YXWzpy82B8zsncBj7ymEqOG-OMeCQrZ_yZir0bIdNuFRtLYRqPrEJdBzqRir4zL7kvALgohViwk5_xuDHmHxYVtFVl699iksK1S9K8cX3dFRd-zHhSBWG_o_2RftQ_cZy7ouR9tmuKz_TwfbdY3fnZ7fzy_rq5uLH_OSqtjOtx5poAYueXGtnUnEunUbUSri-oc4igNCd7jWojveoSCmrwLWN5lDSC6cXco8dbnqfUnxeUx7No8-WhgEDxXU2AlTTdaAL-O0_cBXX6X0dw5VqZ1JqAYWabiibYs6JnHlK_hHTq-Fg3gc120FNkWXQEvi-rcVscXAJg_X5b0px6GRTsPkGW-URl_ThYxq9HejfVrk5pfzDtQ-YDAX5BsLwjlA</recordid><startdate>2000</startdate><enddate>2000</enddate><creator>TANIAI, Tetsuyuki</creator><creator>SAKURAGAWA, Akio</creator><creator>OKUTANI, Tadao</creator><general>The Japan Society for Analytical Chemistry</general><general>Japan Society for Analytical Chemistry</general><general>Japan Science and Technology Agency</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SE</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>FR3</scope><scope>H8G</scope><scope>JG9</scope><scope>L7M</scope><scope>P64</scope><scope>7TG</scope><scope>KL.</scope></search><sort><creationdate>2000</creationdate><title>Monitoring of Hydrogen Peroxide, Nitrate and Nitrite in Rain Water</title><author>TANIAI, Tetsuyuki ; SAKURAGAWA, Akio ; OKUTANI, Tadao</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c577t-eeb0bdef8c534113f7aa742fd6e9ca002797d70491da4e44c40f86710577bf7b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>Analytical chemistry</topic><topic>Applied sciences</topic><topic>Chemistry</topic><topic>Exact sciences and technology</topic><topic>Natural water pollution</topic><topic>Pollution</topic><topic>Rainwaters, run off water and others</topic><topic>Spectrometric and optical methods</topic><topic>Water treatment and pollution</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>TANIAI, Tetsuyuki</creatorcontrib><creatorcontrib>SAKURAGAWA, Akio</creatorcontrib><creatorcontrib>OKUTANI, Tadao</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Copper Technical Reference Library</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Meteorological & Geoastrophysical Abstracts</collection><collection>Meteorological & Geoastrophysical Abstracts - Academic</collection><jtitle>Analytical Sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>TANIAI, Tetsuyuki</au><au>SAKURAGAWA, Akio</au><au>OKUTANI, Tadao</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Monitoring of Hydrogen Peroxide, Nitrate and Nitrite in Rain Water</atitle><jtitle>Analytical Sciences</jtitle><date>2000</date><risdate>2000</risdate><volume>16</volume><issue>3</issue><spage>275</spage><epage>281</epage><pages>275-281</pages><issn>0910-6340</issn><eissn>1348-2246</eissn><coden>ANSCEN</coden><abstract>The relationship between hydrogen peroxide and nitrate and nitrite by monitoring these substances in rain water was investigated. For the determination of hydrogen peroxide, our previously reported FIA system was applied. For the determination of nitrate and nitrite, an FIA system consisting a copperized cadmium reduction column and 2,3-diaminonaphthalene (DAN) used as fluorescence substance was developed. Under the recommended conditions, it took 8 min to determine the sum of nitrate and nitrite while passing through the copperized cadmium reduction column; it took 6 min under the same condition to determine nitrite without passing through the column. The concentration of nitrate was calculated from the difference between the sum of nitrate and nitrite and nitrite. The detection limit, which was defined by a signal-to-noise ratio of 3, was calculated to be 0.1 μmol dm-3 for nitrite. Also, the relative standard deviation at 20 μmol dm-3 of nitrate was under 1.0% (n = 10). There was no interference from the major substances present in rain. The reaction scheme was based on the monitoring results.</abstract><cop>Tokyo</cop><pub>The Japan Society for Analytical Chemistry</pub><doi>10.2116/analsci.16.275</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0910-6340 |
ispartof | Analytical Sciences, 2000, Vol.16(3), pp.275-281 |
issn | 0910-6340 1348-2246 |
language | eng |
recordid | cdi_proquest_miscellaneous_20469907 |
source | J-STAGE Free; Springer Nature - Complete Springer Journals; Freely Accessible Japanese Titles; EZB-FREE-00999 freely available EZB journals; Free Full-Text Journals in Chemistry |
subjects | Analytical chemistry Applied sciences Chemistry Exact sciences and technology Natural water pollution Pollution Rainwaters, run off water and others Spectrometric and optical methods Water treatment and pollution |
title | Monitoring of Hydrogen Peroxide, Nitrate and Nitrite in Rain Water |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-13T17%3A08%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Monitoring%20of%20Hydrogen%20Peroxide,%20Nitrate%20and%20Nitrite%20in%20Rain%20Water&rft.jtitle=Analytical%20Sciences&rft.au=TANIAI,%20Tetsuyuki&rft.date=2000&rft.volume=16&rft.issue=3&rft.spage=275&rft.epage=281&rft.pages=275-281&rft.issn=0910-6340&rft.eissn=1348-2246&rft.coden=ANSCEN&rft_id=info:doi/10.2116/analsci.16.275&rft_dat=%3Cproquest_cross%3E3117949671%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1448533720&rft_id=info:pmid/&rfr_iscdi=true |