Quadrupedal rodent gait compensations in a low dose monoiodoacetate model of osteoarthritis

•Examined rat quadrupedal gait after intra-articular injection of saline or 1 mg MIA.•1 mg MIA resulted in minor joint degeneration and a shuffle-step compensation.•Shuffle-step compensations in rats were previously reported in a surgical OA model.•Antalgic compensations in rats were previously repo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Gait & posture 2018-06, Vol.63, p.73-79
Hauptverfasser: Lakes, Emily H., Allen, Kyle D.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 79
container_issue
container_start_page 73
container_title Gait & posture
container_volume 63
creator Lakes, Emily H.
Allen, Kyle D.
description •Examined rat quadrupedal gait after intra-articular injection of saline or 1 mg MIA.•1 mg MIA resulted in minor joint degeneration and a shuffle-step compensation.•Shuffle-step compensations in rats were previously reported in a surgical OA model.•Antalgic compensations in rats were previously reported in a 3 mg MIA model Rodent gait analysis provides robust, quantitative results for preclinical musculoskeletal and neurological models. In prior work, surgical models of osteoarthritis have been found to result in a hind limb shuffle-stepping gait compensation, while a high dose monoiodoacetate (MIA, 3 mg) model resulted in a hind limb antalgic gait. However, it is unknown whether the antalgic gait caused by MIA is associated with severity of degeneration from the high dosage or the whole-joint degeneration associated with glycolysis inhibition. This study evaluates rodent gait changes resulting from a low dose, 1 mg unilateral intra-articular injection of MIA compared to saline injected and naïve rats. Spatiotemporal and dynamic gait parameters were collected from a total of 42 male Lewis rats spread across 3 time points: 1, 2, and 4 weeks post-injection. To provide a detailed analysis of this low dose MIA model, gait analysis was used to uniquely quantify both fore and hind limb gait parameters. Our data indicate that 1 mg of MIA caused relatively minor degeneration and a shuffle-step gait compensation, similar to the compensation observed in prior surgical models. These data from a 1 mg MIA model show a different gait compensation compared to a previously studied 3 mg model. This 1 mg MIA model resulted in gait compensations more similar to a previously studied surgical model of osteoarthritis. Additionally, this study provides detailed 4 limb analysis of rodent gait that includes spatiotemporal and dynamic data from the same gait trial. These data highlight the importance of measuring dynamic data in combination with spatiotemporal data, since compensatory gait patterns may not be captured by spatial, temporal, or dynamic characterizations alone.
doi_str_mv 10.1016/j.gaitpost.2018.04.023
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2035242790</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0966636218304065</els_id><sourcerecordid>2035242790</sourcerecordid><originalsourceid>FETCH-LOGICAL-c368t-89ff860cc483f5de157fee1c4b41d2bc7e72282576f79d5848eb38b14cc225a23</originalsourceid><addsrcrecordid>eNqFkMtq3TAQhkVpaE7TvkLQshu70kiW5V1K6A0CIZCsshCyNG51sC1HkhPy9vXhJNl2NQz8l5mPkHPOas64-rqv_9hQlphLDYzrmsmagXhHdly3XQXAu_dkxzqlKiUUnJKPOe8ZY1Jo-EBOoWtBqIbvyP3Nan1aF_R2pCl6nAs9JFMXpwXnbEuIc6ZhppaO8Yn6mJFOcY4h-mgdFlsOu8eRxoFu52C0qfxNoYT8iZwMdsz4-WWekbsf328vf1VX1z9_X367qpxQulS6GwatmHNSi6HxyJt2QORO9pJ76F2LLYCGplVD2_lGS4290D2XzgE0FsQZ-XLMXVJ8WDEXM4XscBztjHHNBphoQELbsU2qjlKXYs4JB7OkMNn0bDgzB7Bmb17BmgNYw6TZwG7G85eOtZ_Qv9leSW6Ci6MAt08fAyaTXcDZoQ8JXTE-hv91_AOCbY8X</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2035242790</pqid></control><display><type>article</type><title>Quadrupedal rodent gait compensations in a low dose monoiodoacetate model of osteoarthritis</title><source>Elsevier ScienceDirect Journals Complete - AutoHoldings</source><creator>Lakes, Emily H. ; Allen, Kyle D.</creator><creatorcontrib>Lakes, Emily H. ; Allen, Kyle D.</creatorcontrib><description>•Examined rat quadrupedal gait after intra-articular injection of saline or 1 mg MIA.•1 mg MIA resulted in minor joint degeneration and a shuffle-step compensation.•Shuffle-step compensations in rats were previously reported in a surgical OA model.•Antalgic compensations in rats were previously reported in a 3 mg MIA model Rodent gait analysis provides robust, quantitative results for preclinical musculoskeletal and neurological models. In prior work, surgical models of osteoarthritis have been found to result in a hind limb shuffle-stepping gait compensation, while a high dose monoiodoacetate (MIA, 3 mg) model resulted in a hind limb antalgic gait. However, it is unknown whether the antalgic gait caused by MIA is associated with severity of degeneration from the high dosage or the whole-joint degeneration associated with glycolysis inhibition. This study evaluates rodent gait changes resulting from a low dose, 1 mg unilateral intra-articular injection of MIA compared to saline injected and naïve rats. Spatiotemporal and dynamic gait parameters were collected from a total of 42 male Lewis rats spread across 3 time points: 1, 2, and 4 weeks post-injection. To provide a detailed analysis of this low dose MIA model, gait analysis was used to uniquely quantify both fore and hind limb gait parameters. Our data indicate that 1 mg of MIA caused relatively minor degeneration and a shuffle-step gait compensation, similar to the compensation observed in prior surgical models. These data from a 1 mg MIA model show a different gait compensation compared to a previously studied 3 mg model. This 1 mg MIA model resulted in gait compensations more similar to a previously studied surgical model of osteoarthritis. Additionally, this study provides detailed 4 limb analysis of rodent gait that includes spatiotemporal and dynamic data from the same gait trial. These data highlight the importance of measuring dynamic data in combination with spatiotemporal data, since compensatory gait patterns may not be captured by spatial, temporal, or dynamic characterizations alone.</description><identifier>ISSN: 0966-6362</identifier><identifier>EISSN: 1879-2219</identifier><identifier>DOI: 10.1016/j.gaitpost.2018.04.023</identifier><identifier>PMID: 29723651</identifier><language>eng</language><publisher>England: Elsevier B.V</publisher><subject>Gait ; Monoiodoacetate ; Osteoarthritis ; Rodent ; Spatiotemporal</subject><ispartof>Gait &amp; posture, 2018-06, Vol.63, p.73-79</ispartof><rights>2018 Elsevier B.V.</rights><rights>Copyright © 2018 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c368t-89ff860cc483f5de157fee1c4b41d2bc7e72282576f79d5848eb38b14cc225a23</citedby><cites>FETCH-LOGICAL-c368t-89ff860cc483f5de157fee1c4b41d2bc7e72282576f79d5848eb38b14cc225a23</cites><orcidid>0000-0002-4470-9148</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.gaitpost.2018.04.023$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3548,27922,27923,45993</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29723651$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lakes, Emily H.</creatorcontrib><creatorcontrib>Allen, Kyle D.</creatorcontrib><title>Quadrupedal rodent gait compensations in a low dose monoiodoacetate model of osteoarthritis</title><title>Gait &amp; posture</title><addtitle>Gait Posture</addtitle><description>•Examined rat quadrupedal gait after intra-articular injection of saline or 1 mg MIA.•1 mg MIA resulted in minor joint degeneration and a shuffle-step compensation.•Shuffle-step compensations in rats were previously reported in a surgical OA model.•Antalgic compensations in rats were previously reported in a 3 mg MIA model Rodent gait analysis provides robust, quantitative results for preclinical musculoskeletal and neurological models. In prior work, surgical models of osteoarthritis have been found to result in a hind limb shuffle-stepping gait compensation, while a high dose monoiodoacetate (MIA, 3 mg) model resulted in a hind limb antalgic gait. However, it is unknown whether the antalgic gait caused by MIA is associated with severity of degeneration from the high dosage or the whole-joint degeneration associated with glycolysis inhibition. This study evaluates rodent gait changes resulting from a low dose, 1 mg unilateral intra-articular injection of MIA compared to saline injected and naïve rats. Spatiotemporal and dynamic gait parameters were collected from a total of 42 male Lewis rats spread across 3 time points: 1, 2, and 4 weeks post-injection. To provide a detailed analysis of this low dose MIA model, gait analysis was used to uniquely quantify both fore and hind limb gait parameters. Our data indicate that 1 mg of MIA caused relatively minor degeneration and a shuffle-step gait compensation, similar to the compensation observed in prior surgical models. These data from a 1 mg MIA model show a different gait compensation compared to a previously studied 3 mg model. This 1 mg MIA model resulted in gait compensations more similar to a previously studied surgical model of osteoarthritis. Additionally, this study provides detailed 4 limb analysis of rodent gait that includes spatiotemporal and dynamic data from the same gait trial. These data highlight the importance of measuring dynamic data in combination with spatiotemporal data, since compensatory gait patterns may not be captured by spatial, temporal, or dynamic characterizations alone.</description><subject>Gait</subject><subject>Monoiodoacetate</subject><subject>Osteoarthritis</subject><subject>Rodent</subject><subject>Spatiotemporal</subject><issn>0966-6362</issn><issn>1879-2219</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqFkMtq3TAQhkVpaE7TvkLQshu70kiW5V1K6A0CIZCsshCyNG51sC1HkhPy9vXhJNl2NQz8l5mPkHPOas64-rqv_9hQlphLDYzrmsmagXhHdly3XQXAu_dkxzqlKiUUnJKPOe8ZY1Jo-EBOoWtBqIbvyP3Nan1aF_R2pCl6nAs9JFMXpwXnbEuIc6ZhppaO8Yn6mJFOcY4h-mgdFlsOu8eRxoFu52C0qfxNoYT8iZwMdsz4-WWekbsf328vf1VX1z9_X367qpxQulS6GwatmHNSi6HxyJt2QORO9pJ76F2LLYCGplVD2_lGS4290D2XzgE0FsQZ-XLMXVJ8WDEXM4XscBztjHHNBphoQELbsU2qjlKXYs4JB7OkMNn0bDgzB7Bmb17BmgNYw6TZwG7G85eOtZ_Qv9leSW6Ci6MAt08fAyaTXcDZoQ8JXTE-hv91_AOCbY8X</recordid><startdate>20180601</startdate><enddate>20180601</enddate><creator>Lakes, Emily H.</creator><creator>Allen, Kyle D.</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-4470-9148</orcidid></search><sort><creationdate>20180601</creationdate><title>Quadrupedal rodent gait compensations in a low dose monoiodoacetate model of osteoarthritis</title><author>Lakes, Emily H. ; Allen, Kyle D.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c368t-89ff860cc483f5de157fee1c4b41d2bc7e72282576f79d5848eb38b14cc225a23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Gait</topic><topic>Monoiodoacetate</topic><topic>Osteoarthritis</topic><topic>Rodent</topic><topic>Spatiotemporal</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lakes, Emily H.</creatorcontrib><creatorcontrib>Allen, Kyle D.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Gait &amp; posture</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lakes, Emily H.</au><au>Allen, Kyle D.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Quadrupedal rodent gait compensations in a low dose monoiodoacetate model of osteoarthritis</atitle><jtitle>Gait &amp; posture</jtitle><addtitle>Gait Posture</addtitle><date>2018-06-01</date><risdate>2018</risdate><volume>63</volume><spage>73</spage><epage>79</epage><pages>73-79</pages><issn>0966-6362</issn><eissn>1879-2219</eissn><abstract>•Examined rat quadrupedal gait after intra-articular injection of saline or 1 mg MIA.•1 mg MIA resulted in minor joint degeneration and a shuffle-step compensation.•Shuffle-step compensations in rats were previously reported in a surgical OA model.•Antalgic compensations in rats were previously reported in a 3 mg MIA model Rodent gait analysis provides robust, quantitative results for preclinical musculoskeletal and neurological models. In prior work, surgical models of osteoarthritis have been found to result in a hind limb shuffle-stepping gait compensation, while a high dose monoiodoacetate (MIA, 3 mg) model resulted in a hind limb antalgic gait. However, it is unknown whether the antalgic gait caused by MIA is associated with severity of degeneration from the high dosage or the whole-joint degeneration associated with glycolysis inhibition. This study evaluates rodent gait changes resulting from a low dose, 1 mg unilateral intra-articular injection of MIA compared to saline injected and naïve rats. Spatiotemporal and dynamic gait parameters were collected from a total of 42 male Lewis rats spread across 3 time points: 1, 2, and 4 weeks post-injection. To provide a detailed analysis of this low dose MIA model, gait analysis was used to uniquely quantify both fore and hind limb gait parameters. Our data indicate that 1 mg of MIA caused relatively minor degeneration and a shuffle-step gait compensation, similar to the compensation observed in prior surgical models. These data from a 1 mg MIA model show a different gait compensation compared to a previously studied 3 mg model. This 1 mg MIA model resulted in gait compensations more similar to a previously studied surgical model of osteoarthritis. Additionally, this study provides detailed 4 limb analysis of rodent gait that includes spatiotemporal and dynamic data from the same gait trial. These data highlight the importance of measuring dynamic data in combination with spatiotemporal data, since compensatory gait patterns may not be captured by spatial, temporal, or dynamic characterizations alone.</abstract><cop>England</cop><pub>Elsevier B.V</pub><pmid>29723651</pmid><doi>10.1016/j.gaitpost.2018.04.023</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0002-4470-9148</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0966-6362
ispartof Gait & posture, 2018-06, Vol.63, p.73-79
issn 0966-6362
1879-2219
language eng
recordid cdi_proquest_miscellaneous_2035242790
source Elsevier ScienceDirect Journals Complete - AutoHoldings
subjects Gait
Monoiodoacetate
Osteoarthritis
Rodent
Spatiotemporal
title Quadrupedal rodent gait compensations in a low dose monoiodoacetate model of osteoarthritis
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T13%3A55%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Quadrupedal%20rodent%20gait%20compensations%20in%20a%20low%20dose%20monoiodoacetate%20model%20of%20osteoarthritis&rft.jtitle=Gait%20&%20posture&rft.au=Lakes,%20Emily%20H.&rft.date=2018-06-01&rft.volume=63&rft.spage=73&rft.epage=79&rft.pages=73-79&rft.issn=0966-6362&rft.eissn=1879-2219&rft_id=info:doi/10.1016/j.gaitpost.2018.04.023&rft_dat=%3Cproquest_cross%3E2035242790%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2035242790&rft_id=info:pmid/29723651&rft_els_id=S0966636218304065&rfr_iscdi=true