Full-circle range and microradian resolution angle measurement using the orthogonal mirror self-mixing interferometry

The self-mixing technique based on the traditional reflecting mirror has been demonstrated with great merit for angle sensing applications. In order to solve the problems of the narrow measurement angle range and low resolution in traditional angle measurement method, we proposed an angle measuremen...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Optics express 2018-04, Vol.26 (8), p.10371-10381
Hauptverfasser: Wang, Chenchen, Fan, Xuewei, Guo, You, Gui, Huaqiao, Wang, Huanqing, Liu, Jianguo, Yu, Benli, Lu, Liang
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 10381
container_issue 8
container_start_page 10371
container_title Optics express
container_volume 26
creator Wang, Chenchen
Fan, Xuewei
Guo, You
Gui, Huaqiao
Wang, Huanqing
Liu, Jianguo
Yu, Benli
Lu, Liang
description The self-mixing technique based on the traditional reflecting mirror has been demonstrated with great merit for angle sensing applications. In order to solve the problems of the narrow measurement angle range and low resolution in traditional angle measurement method, we proposed an angle measurement system using orthogonal mirror self-mixing interferometry combine an orthogonal mirror with designed mechanical linkage. It overcomes the shortcomings of traditional angle measurement methods and realized the angle measurement with microradian resolution in a full-circle range of 0 rad to 2π rad. In the experiment, the measurement resolution can reach to 5.27 µrad and the absolute error can lower to ± 0.011µrad, which satisfies the requirements of most high accuracy angle measurement.
doi_str_mv 10.1364/OE.26.010371
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2033378429</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2033378429</sourcerecordid><originalsourceid>FETCH-LOGICAL-c329t-1d7dd6c5a1380b90a788adfc01bb74fb470449716b1ea366752fe511dbd3e53c3</originalsourceid><addsrcrecordid>eNpNkM9LwzAcxYMoTqc3z5KjBzuTJm3ao4xNhcEuei5p8-0WyY-ZNOD-ezs2xdP3wffzHryH0B0lM8pK_rRezPJyRihhgp6hK0pqnnFSifN_eoKuY_wkhHJRi0s0yWtBi1rwK5SWyZis06EzgIN0G8DSKWx1F3yQSkuHA0Rv0qC9G1-bEbMgYwpgwQ04Re02eNgC9mHY-o130ozuMLpxBNNnVn8fCO0GCD0Eb2EI-xt00UsT4fZ0p-hjuXifv2ar9cvb_HmVdSyvh4wqoVTZFZKyirQ1kaKqpOo7QttW8L7lgnA-VilbCpKVpSjyHgpKVasYFKxjU_RwzN0F_5UgDo3VsQNjpAOfYpMTxpioeF6P6OMRHYvHGKBvdkFbGfYNJc1h6Ga9aPKyOQ494ven5NRaUH_w77LsB6aSe2c</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2033378429</pqid></control><display><type>article</type><title>Full-circle range and microradian resolution angle measurement using the orthogonal mirror self-mixing interferometry</title><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><creator>Wang, Chenchen ; Fan, Xuewei ; Guo, You ; Gui, Huaqiao ; Wang, Huanqing ; Liu, Jianguo ; Yu, Benli ; Lu, Liang</creator><creatorcontrib>Wang, Chenchen ; Fan, Xuewei ; Guo, You ; Gui, Huaqiao ; Wang, Huanqing ; Liu, Jianguo ; Yu, Benli ; Lu, Liang</creatorcontrib><description>The self-mixing technique based on the traditional reflecting mirror has been demonstrated with great merit for angle sensing applications. In order to solve the problems of the narrow measurement angle range and low resolution in traditional angle measurement method, we proposed an angle measurement system using orthogonal mirror self-mixing interferometry combine an orthogonal mirror with designed mechanical linkage. It overcomes the shortcomings of traditional angle measurement methods and realized the angle measurement with microradian resolution in a full-circle range of 0 rad to 2π rad. In the experiment, the measurement resolution can reach to 5.27 µrad and the absolute error can lower to ± 0.011µrad, which satisfies the requirements of most high accuracy angle measurement.</description><identifier>ISSN: 1094-4087</identifier><identifier>EISSN: 1094-4087</identifier><identifier>DOI: 10.1364/OE.26.010371</identifier><identifier>PMID: 29715974</identifier><language>eng</language><publisher>United States</publisher><ispartof>Optics express, 2018-04, Vol.26 (8), p.10371-10381</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c329t-1d7dd6c5a1380b90a788adfc01bb74fb470449716b1ea366752fe511dbd3e53c3</citedby><cites>FETCH-LOGICAL-c329t-1d7dd6c5a1380b90a788adfc01bb74fb470449716b1ea366752fe511dbd3e53c3</cites><orcidid>0000-0002-7778-7820 ; 0000-0002-7051-4272 ; 0000-0002-7418-3917</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,860,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29715974$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Wang, Chenchen</creatorcontrib><creatorcontrib>Fan, Xuewei</creatorcontrib><creatorcontrib>Guo, You</creatorcontrib><creatorcontrib>Gui, Huaqiao</creatorcontrib><creatorcontrib>Wang, Huanqing</creatorcontrib><creatorcontrib>Liu, Jianguo</creatorcontrib><creatorcontrib>Yu, Benli</creatorcontrib><creatorcontrib>Lu, Liang</creatorcontrib><title>Full-circle range and microradian resolution angle measurement using the orthogonal mirror self-mixing interferometry</title><title>Optics express</title><addtitle>Opt Express</addtitle><description>The self-mixing technique based on the traditional reflecting mirror has been demonstrated with great merit for angle sensing applications. In order to solve the problems of the narrow measurement angle range and low resolution in traditional angle measurement method, we proposed an angle measurement system using orthogonal mirror self-mixing interferometry combine an orthogonal mirror with designed mechanical linkage. It overcomes the shortcomings of traditional angle measurement methods and realized the angle measurement with microradian resolution in a full-circle range of 0 rad to 2π rad. In the experiment, the measurement resolution can reach to 5.27 µrad and the absolute error can lower to ± 0.011µrad, which satisfies the requirements of most high accuracy angle measurement.</description><issn>1094-4087</issn><issn>1094-4087</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNpNkM9LwzAcxYMoTqc3z5KjBzuTJm3ao4xNhcEuei5p8-0WyY-ZNOD-ezs2xdP3wffzHryH0B0lM8pK_rRezPJyRihhgp6hK0pqnnFSifN_eoKuY_wkhHJRi0s0yWtBi1rwK5SWyZis06EzgIN0G8DSKWx1F3yQSkuHA0Rv0qC9G1-bEbMgYwpgwQ04Re02eNgC9mHY-o130ozuMLpxBNNnVn8fCO0GCD0Eb2EI-xt00UsT4fZ0p-hjuXifv2ar9cvb_HmVdSyvh4wqoVTZFZKyirQ1kaKqpOo7QttW8L7lgnA-VilbCpKVpSjyHgpKVasYFKxjU_RwzN0F_5UgDo3VsQNjpAOfYpMTxpioeF6P6OMRHYvHGKBvdkFbGfYNJc1h6Ga9aPKyOQ494ven5NRaUH_w77LsB6aSe2c</recordid><startdate>20180416</startdate><enddate>20180416</enddate><creator>Wang, Chenchen</creator><creator>Fan, Xuewei</creator><creator>Guo, You</creator><creator>Gui, Huaqiao</creator><creator>Wang, Huanqing</creator><creator>Liu, Jianguo</creator><creator>Yu, Benli</creator><creator>Lu, Liang</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-7778-7820</orcidid><orcidid>https://orcid.org/0000-0002-7051-4272</orcidid><orcidid>https://orcid.org/0000-0002-7418-3917</orcidid></search><sort><creationdate>20180416</creationdate><title>Full-circle range and microradian resolution angle measurement using the orthogonal mirror self-mixing interferometry</title><author>Wang, Chenchen ; Fan, Xuewei ; Guo, You ; Gui, Huaqiao ; Wang, Huanqing ; Liu, Jianguo ; Yu, Benli ; Lu, Liang</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c329t-1d7dd6c5a1380b90a788adfc01bb74fb470449716b1ea366752fe511dbd3e53c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wang, Chenchen</creatorcontrib><creatorcontrib>Fan, Xuewei</creatorcontrib><creatorcontrib>Guo, You</creatorcontrib><creatorcontrib>Gui, Huaqiao</creatorcontrib><creatorcontrib>Wang, Huanqing</creatorcontrib><creatorcontrib>Liu, Jianguo</creatorcontrib><creatorcontrib>Yu, Benli</creatorcontrib><creatorcontrib>Lu, Liang</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Optics express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wang, Chenchen</au><au>Fan, Xuewei</au><au>Guo, You</au><au>Gui, Huaqiao</au><au>Wang, Huanqing</au><au>Liu, Jianguo</au><au>Yu, Benli</au><au>Lu, Liang</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Full-circle range and microradian resolution angle measurement using the orthogonal mirror self-mixing interferometry</atitle><jtitle>Optics express</jtitle><addtitle>Opt Express</addtitle><date>2018-04-16</date><risdate>2018</risdate><volume>26</volume><issue>8</issue><spage>10371</spage><epage>10381</epage><pages>10371-10381</pages><issn>1094-4087</issn><eissn>1094-4087</eissn><abstract>The self-mixing technique based on the traditional reflecting mirror has been demonstrated with great merit for angle sensing applications. In order to solve the problems of the narrow measurement angle range and low resolution in traditional angle measurement method, we proposed an angle measurement system using orthogonal mirror self-mixing interferometry combine an orthogonal mirror with designed mechanical linkage. It overcomes the shortcomings of traditional angle measurement methods and realized the angle measurement with microradian resolution in a full-circle range of 0 rad to 2π rad. In the experiment, the measurement resolution can reach to 5.27 µrad and the absolute error can lower to ± 0.011µrad, which satisfies the requirements of most high accuracy angle measurement.</abstract><cop>United States</cop><pmid>29715974</pmid><doi>10.1364/OE.26.010371</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0002-7778-7820</orcidid><orcidid>https://orcid.org/0000-0002-7051-4272</orcidid><orcidid>https://orcid.org/0000-0002-7418-3917</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1094-4087
ispartof Optics express, 2018-04, Vol.26 (8), p.10371-10381
issn 1094-4087
1094-4087
language eng
recordid cdi_proquest_miscellaneous_2033378429
source DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection
title Full-circle range and microradian resolution angle measurement using the orthogonal mirror self-mixing interferometry
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T17%3A58%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Full-circle%20range%20and%20microradian%20resolution%20angle%20measurement%20using%20the%20orthogonal%20mirror%20self-mixing%20interferometry&rft.jtitle=Optics%20express&rft.au=Wang,%20Chenchen&rft.date=2018-04-16&rft.volume=26&rft.issue=8&rft.spage=10371&rft.epage=10381&rft.pages=10371-10381&rft.issn=1094-4087&rft.eissn=1094-4087&rft_id=info:doi/10.1364/OE.26.010371&rft_dat=%3Cproquest_cross%3E2033378429%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2033378429&rft_id=info:pmid/29715974&rfr_iscdi=true