Comparison of Phoenix and VITEK 2 Extended-Spectrum-{szligbeta}-Lactamase Detection Tests for Analysis of Escherichia coli and Klebsiella Isolates with Well-Characterized {szligbeta}-Lactamases

The VITEK 2 and Phoenix extended-spectrum {szligbeta}-lactamase (ESBL) detection systems, which comprise confirmatory tests and expert systems, were evaluated for their ability to discriminate between 102 well-characterized strains of ESBL-positive or -negative Escherichia coli, Klebsiella pneumonia...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Clinical Microbiology 2007-08, Vol.45 (8), p.2380-2384
Hauptverfasser: Thomson, Kenneth S, Cornish, Nancy E, Hong, Seong G, Hemrick, Kim, Herdt, Christian, Moland, Ellen S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2384
container_issue 8
container_start_page 2380
container_title Journal of Clinical Microbiology
container_volume 45
creator Thomson, Kenneth S
Cornish, Nancy E
Hong, Seong G
Hemrick, Kim
Herdt, Christian
Moland, Ellen S
description The VITEK 2 and Phoenix extended-spectrum {szligbeta}-lactamase (ESBL) detection systems, which comprise confirmatory tests and expert systems, were evaluated for their ability to discriminate between 102 well-characterized strains of ESBL-positive or -negative Escherichia coli, Klebsiella pneumoniae, and Klebsiella oxytoca. At least 38 distinct ESBLs were included. The strains were chosen to include some known to cause false-positive and false-negative CLSI ESBL confirmatory test results. Therefore, enzyme characterizations, rather than CLSI tests, were the reference methods for the Phoenix and VITEK 2 evaluations. A third arm of the study was conducted with the Phoenix test using two normally inactive expert rules intended to enhance ESBL detection, in addition to using the currently available software. The Phoenix ESBL confirmatory test and unmodified expert system exhibited 96% sensitivity and 81% specificity for ESBL detection. Activation of the two additional rules increased sensitivity to 99% but reduced the specificity to 58%. The VITEK 2 ESBL confirmatory test exhibited 91% sensitivity, which was reduced to 89% sensitivity by its expert system, while its specificity was 85%. Many of the expert system interpretations of both instruments were helpful, but some were suboptimal. The VITEK 2 expert system was potentially more frustrating because it provided more inconclusive interpretations of the results. Considering the high degree of diagnostic difficulty posed by the strains, both ESBL confirmatory tests were highly sensitive. The expert systems of both instruments require modification to update and enhance their utility.
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_20267369</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>20267369</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_202673693</originalsourceid><addsrcrecordid>eNqNjk1LxDAQhoMoWD_-w5y8BdJ2u2uPUisu60Gw6HHJplMbSZOaSXFd8cf5z8yKRw-eBt535nnmgCWpKC95UeTikCVClAVP03xxzE6IXoRIZ7OiSNhX5YZRek3Oguvgvndo9RakbeFx2dQryKDeBrQttvxhRBX8NPAP2hn9vMEgP_mdVEEOkhCuMcReR1CDFAg65-HKSvNOmvbsmlSPXqteS1DO6B_JyuCGNBojYUnOyIAEbzr08BQzXvXSR3682mELf2rpjB110hCe_85TdnFTN9UtH717neIn60GT2hssuonWmcjmi3xe5v9e_AaYVm2e</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>20267369</pqid></control><display><type>article</type><title>Comparison of Phoenix and VITEK 2 Extended-Spectrum-{szligbeta}-Lactamase Detection Tests for Analysis of Escherichia coli and Klebsiella Isolates with Well-Characterized {szligbeta}-Lactamases</title><source>American Society for Microbiology Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><creator>Thomson, Kenneth S ; Cornish, Nancy E ; Hong, Seong G ; Hemrick, Kim ; Herdt, Christian ; Moland, Ellen S</creator><creatorcontrib>Thomson, Kenneth S ; Cornish, Nancy E ; Hong, Seong G ; Hemrick, Kim ; Herdt, Christian ; Moland, Ellen S</creatorcontrib><description>The VITEK 2 and Phoenix extended-spectrum {szligbeta}-lactamase (ESBL) detection systems, which comprise confirmatory tests and expert systems, were evaluated for their ability to discriminate between 102 well-characterized strains of ESBL-positive or -negative Escherichia coli, Klebsiella pneumoniae, and Klebsiella oxytoca. At least 38 distinct ESBLs were included. The strains were chosen to include some known to cause false-positive and false-negative CLSI ESBL confirmatory test results. Therefore, enzyme characterizations, rather than CLSI tests, were the reference methods for the Phoenix and VITEK 2 evaluations. A third arm of the study was conducted with the Phoenix test using two normally inactive expert rules intended to enhance ESBL detection, in addition to using the currently available software. The Phoenix ESBL confirmatory test and unmodified expert system exhibited 96% sensitivity and 81% specificity for ESBL detection. Activation of the two additional rules increased sensitivity to 99% but reduced the specificity to 58%. The VITEK 2 ESBL confirmatory test exhibited 91% sensitivity, which was reduced to 89% sensitivity by its expert system, while its specificity was 85%. Many of the expert system interpretations of both instruments were helpful, but some were suboptimal. The VITEK 2 expert system was potentially more frustrating because it provided more inconclusive interpretations of the results. Considering the high degree of diagnostic difficulty posed by the strains, both ESBL confirmatory tests were highly sensitive. The expert systems of both instruments require modification to update and enhance their utility.</description><identifier>ISSN: 0095-1137</identifier><identifier>EISSN: 1098-5530</identifier><language>eng</language><subject>Escherichia coli ; Klebsiella oxytoca ; Klebsiella pneumoniae</subject><ispartof>Journal of Clinical Microbiology, 2007-08, Vol.45 (8), p.2380-2384</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids></links><search><creatorcontrib>Thomson, Kenneth S</creatorcontrib><creatorcontrib>Cornish, Nancy E</creatorcontrib><creatorcontrib>Hong, Seong G</creatorcontrib><creatorcontrib>Hemrick, Kim</creatorcontrib><creatorcontrib>Herdt, Christian</creatorcontrib><creatorcontrib>Moland, Ellen S</creatorcontrib><title>Comparison of Phoenix and VITEK 2 Extended-Spectrum-{szligbeta}-Lactamase Detection Tests for Analysis of Escherichia coli and Klebsiella Isolates with Well-Characterized {szligbeta}-Lactamases</title><title>Journal of Clinical Microbiology</title><description>The VITEK 2 and Phoenix extended-spectrum {szligbeta}-lactamase (ESBL) detection systems, which comprise confirmatory tests and expert systems, were evaluated for their ability to discriminate between 102 well-characterized strains of ESBL-positive or -negative Escherichia coli, Klebsiella pneumoniae, and Klebsiella oxytoca. At least 38 distinct ESBLs were included. The strains were chosen to include some known to cause false-positive and false-negative CLSI ESBL confirmatory test results. Therefore, enzyme characterizations, rather than CLSI tests, were the reference methods for the Phoenix and VITEK 2 evaluations. A third arm of the study was conducted with the Phoenix test using two normally inactive expert rules intended to enhance ESBL detection, in addition to using the currently available software. The Phoenix ESBL confirmatory test and unmodified expert system exhibited 96% sensitivity and 81% specificity for ESBL detection. Activation of the two additional rules increased sensitivity to 99% but reduced the specificity to 58%. The VITEK 2 ESBL confirmatory test exhibited 91% sensitivity, which was reduced to 89% sensitivity by its expert system, while its specificity was 85%. Many of the expert system interpretations of both instruments were helpful, but some were suboptimal. The VITEK 2 expert system was potentially more frustrating because it provided more inconclusive interpretations of the results. Considering the high degree of diagnostic difficulty posed by the strains, both ESBL confirmatory tests were highly sensitive. The expert systems of both instruments require modification to update and enhance their utility.</description><subject>Escherichia coli</subject><subject>Klebsiella oxytoca</subject><subject>Klebsiella pneumoniae</subject><issn>0095-1137</issn><issn>1098-5530</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNqNjk1LxDAQhoMoWD_-w5y8BdJ2u2uPUisu60Gw6HHJplMbSZOaSXFd8cf5z8yKRw-eBt535nnmgCWpKC95UeTikCVClAVP03xxzE6IXoRIZ7OiSNhX5YZRek3Oguvgvndo9RakbeFx2dQryKDeBrQttvxhRBX8NPAP2hn9vMEgP_mdVEEOkhCuMcReR1CDFAg65-HKSvNOmvbsmlSPXqteS1DO6B_JyuCGNBojYUnOyIAEbzr08BQzXvXSR3682mELf2rpjB110hCe_85TdnFTN9UtH717neIn60GT2hssuonWmcjmi3xe5v9e_AaYVm2e</recordid><startdate>20070801</startdate><enddate>20070801</enddate><creator>Thomson, Kenneth S</creator><creator>Cornish, Nancy E</creator><creator>Hong, Seong G</creator><creator>Hemrick, Kim</creator><creator>Herdt, Christian</creator><creator>Moland, Ellen S</creator><scope>7QL</scope><scope>C1K</scope></search><sort><creationdate>20070801</creationdate><title>Comparison of Phoenix and VITEK 2 Extended-Spectrum-{szligbeta}-Lactamase Detection Tests for Analysis of Escherichia coli and Klebsiella Isolates with Well-Characterized {szligbeta}-Lactamases</title><author>Thomson, Kenneth S ; Cornish, Nancy E ; Hong, Seong G ; Hemrick, Kim ; Herdt, Christian ; Moland, Ellen S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_202673693</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Escherichia coli</topic><topic>Klebsiella oxytoca</topic><topic>Klebsiella pneumoniae</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Thomson, Kenneth S</creatorcontrib><creatorcontrib>Cornish, Nancy E</creatorcontrib><creatorcontrib>Hong, Seong G</creatorcontrib><creatorcontrib>Hemrick, Kim</creatorcontrib><creatorcontrib>Herdt, Christian</creatorcontrib><creatorcontrib>Moland, Ellen S</creatorcontrib><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Environmental Sciences and Pollution Management</collection><jtitle>Journal of Clinical Microbiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Thomson, Kenneth S</au><au>Cornish, Nancy E</au><au>Hong, Seong G</au><au>Hemrick, Kim</au><au>Herdt, Christian</au><au>Moland, Ellen S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of Phoenix and VITEK 2 Extended-Spectrum-{szligbeta}-Lactamase Detection Tests for Analysis of Escherichia coli and Klebsiella Isolates with Well-Characterized {szligbeta}-Lactamases</atitle><jtitle>Journal of Clinical Microbiology</jtitle><date>2007-08-01</date><risdate>2007</risdate><volume>45</volume><issue>8</issue><spage>2380</spage><epage>2384</epage><pages>2380-2384</pages><issn>0095-1137</issn><eissn>1098-5530</eissn><abstract>The VITEK 2 and Phoenix extended-spectrum {szligbeta}-lactamase (ESBL) detection systems, which comprise confirmatory tests and expert systems, were evaluated for their ability to discriminate between 102 well-characterized strains of ESBL-positive or -negative Escherichia coli, Klebsiella pneumoniae, and Klebsiella oxytoca. At least 38 distinct ESBLs were included. The strains were chosen to include some known to cause false-positive and false-negative CLSI ESBL confirmatory test results. Therefore, enzyme characterizations, rather than CLSI tests, were the reference methods for the Phoenix and VITEK 2 evaluations. A third arm of the study was conducted with the Phoenix test using two normally inactive expert rules intended to enhance ESBL detection, in addition to using the currently available software. The Phoenix ESBL confirmatory test and unmodified expert system exhibited 96% sensitivity and 81% specificity for ESBL detection. Activation of the two additional rules increased sensitivity to 99% but reduced the specificity to 58%. The VITEK 2 ESBL confirmatory test exhibited 91% sensitivity, which was reduced to 89% sensitivity by its expert system, while its specificity was 85%. Many of the expert system interpretations of both instruments were helpful, but some were suboptimal. The VITEK 2 expert system was potentially more frustrating because it provided more inconclusive interpretations of the results. Considering the high degree of diagnostic difficulty posed by the strains, both ESBL confirmatory tests were highly sensitive. The expert systems of both instruments require modification to update and enhance their utility.</abstract></addata></record>
fulltext fulltext
identifier ISSN: 0095-1137
ispartof Journal of Clinical Microbiology, 2007-08, Vol.45 (8), p.2380-2384
issn 0095-1137
1098-5530
language eng
recordid cdi_proquest_miscellaneous_20267369
source American Society for Microbiology Journals; EZB-FREE-00999 freely available EZB journals; PubMed Central
subjects Escherichia coli
Klebsiella oxytoca
Klebsiella pneumoniae
title Comparison of Phoenix and VITEK 2 Extended-Spectrum-{szligbeta}-Lactamase Detection Tests for Analysis of Escherichia coli and Klebsiella Isolates with Well-Characterized {szligbeta}-Lactamases
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T20%3A10%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20Phoenix%20and%20VITEK%202%20Extended-Spectrum-%7Bszligbeta%7D-Lactamase%20Detection%20Tests%20for%20Analysis%20of%20Escherichia%20coli%20and%20Klebsiella%20Isolates%20with%20Well-Characterized%20%7Bszligbeta%7D-Lactamases&rft.jtitle=Journal%20of%20Clinical%20Microbiology&rft.au=Thomson,%20Kenneth%20S&rft.date=2007-08-01&rft.volume=45&rft.issue=8&rft.spage=2380&rft.epage=2384&rft.pages=2380-2384&rft.issn=0095-1137&rft.eissn=1098-5530&rft_id=info:doi/&rft_dat=%3Cproquest%3E20267369%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=20267369&rft_id=info:pmid/&rfr_iscdi=true