A label-free cellulose SERS biosensor chip with improvement of nanoparticle-enhanced LSPR effects for early diagnosis of subarachnoid hemorrhage-induced complications

It is very difficult to predict some complications after subarachnoid hemorrhage (SAH), despite rapid advances in medical science. Herein, we introduce a label-free cellulose surface-enhanced Raman spectroscopy (SERS) biosensor chip with pH-functionalized, gold nanoparticle (AuNP)-enhanced localized...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biosensors & bioelectronics 2018-07, Vol.111, p.59-65
Hauptverfasser: Kim, Wansun, Lee, Sung Ho, Ahn, Yong Jin, Lee, Seung Ho, Ryu, Jiwook, Choi, Seok Keun, Choi, Samjin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 65
container_issue
container_start_page 59
container_title Biosensors & bioelectronics
container_volume 111
creator Kim, Wansun
Lee, Sung Ho
Ahn, Yong Jin
Lee, Seung Ho
Ryu, Jiwook
Choi, Seok Keun
Choi, Samjin
description It is very difficult to predict some complications after subarachnoid hemorrhage (SAH), despite rapid advances in medical science. Herein, we introduce a label-free cellulose surface-enhanced Raman spectroscopy (SERS) biosensor chip with pH-functionalized, gold nanoparticle (AuNP)-enhanced localized surface plasmon resonance (LSPR) effects for identification of SAH-induced cerebral vasospasm and hydrocephalus caused by cerebrospinal fluid (CSF). The SERS biosensor chip was implemented by the synthesis reaction of the AuNPs, which were charged positively through pH level adjustment, onto a negatively-charged cellulose substrate with ξ = –30.7 mV. The zeta potential, nanostructural properties, nanocrystallinity, and computational calculation-based electric field distributions of the cellulose-originated AuNPs were optimized to maximize LSPR phenomena and then characterized. Additionally, the performance of the SERS biosensor was compared under two representative excitation laser sources in the visible region (532 nm) and near-infrared region (785 nm). The Raman activities of our SERS biosensor chip were evaluated by trace small molecules (crystal violet, 2 µL), and the biosensor achieved an enhancement factor of 3.29 × 109 for the analytic concept with an excellent reproducibility of 8.5% relative standard deviation and a detection limit of 0.74 pM. Furthermore, the experimental results revealed that the five proposed SERS-based biomarkers could provide important information for identifying and predicting SAH-induced cerebral vasospasm and hydrocephalus complications (91.1% reliability and 19.3% reproducibility). Therefore, this facile and effective principle of our SERS biosensor chip may inspire the basis and strategies for the development of sensing platforms to predict critical complications in various neurosurgical diagnoses. [Display omitted] •Bare cellulose at pH 3 showed the lowest negative electric potential, ξ = –30.7 mV.•A pH adjustment led to improved SERS performance of the cellulose biosensor chip.•Five SERS-based biomarkers were proposed to predict SAH-induced complications.
doi_str_mv 10.1016/j.bios.2018.04.003
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2025310155</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0956566318302574</els_id><sourcerecordid>2025310155</sourcerecordid><originalsourceid>FETCH-LOGICAL-c393t-c64d0aa6310e5b7a3da83d406a043d7c7415de046102d7f6b0f595e0fc6ca6dd3</originalsourceid><addsrcrecordid>eNp9kc1u1DAUhS0EokPhBVggL9kkXMexM5HYVFX5kUYCdWBtOfZ141FiBztp1RfiOUk0hSWruznnk-75CHnLoGTA5IdT2fmYywrYvoS6BODPyI7tG17UFRfPyQ5aIQshJb8gr3I-AUDDWnhJLqpW1q0UfEd-X9FBdzgULiFSg8OwDDEjPd7cHumGx5Bjoqb3E33wc0_9OKV4jyOGmUZHgw5x0mn2ZsACQ6-DQUsPx--3FJ1DM2fq1j7qNDxS6_VdiNnnrZmXTidt-hC9pT2OMaVe32Hhg102honjNHijZx9Dfk1eOD1kfPN0L8nPTzc_rr8Uh2-fv15fHQrDWz4XRtYWtJacAYqu0dzqPbc1SA01t41paiYsQi0ZVLZxsgMnWoHgjDRaWssvyfszd33y14J5VqPP2yo6YFyyqqASK5wJsUarc9SkmHNCp6bkR50eFQO1-VEntQ2oNj8KarX6WUvvnvhLN6L9V_krZA18PAdw_fLeY1LZeNxG9WldU9no_8f_A8dfpYI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2025310155</pqid></control><display><type>article</type><title>A label-free cellulose SERS biosensor chip with improvement of nanoparticle-enhanced LSPR effects for early diagnosis of subarachnoid hemorrhage-induced complications</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Kim, Wansun ; Lee, Sung Ho ; Ahn, Yong Jin ; Lee, Seung Ho ; Ryu, Jiwook ; Choi, Seok Keun ; Choi, Samjin</creator><creatorcontrib>Kim, Wansun ; Lee, Sung Ho ; Ahn, Yong Jin ; Lee, Seung Ho ; Ryu, Jiwook ; Choi, Seok Keun ; Choi, Samjin</creatorcontrib><description>It is very difficult to predict some complications after subarachnoid hemorrhage (SAH), despite rapid advances in medical science. Herein, we introduce a label-free cellulose surface-enhanced Raman spectroscopy (SERS) biosensor chip with pH-functionalized, gold nanoparticle (AuNP)-enhanced localized surface plasmon resonance (LSPR) effects for identification of SAH-induced cerebral vasospasm and hydrocephalus caused by cerebrospinal fluid (CSF). The SERS biosensor chip was implemented by the synthesis reaction of the AuNPs, which were charged positively through pH level adjustment, onto a negatively-charged cellulose substrate with ξ = –30.7 mV. The zeta potential, nanostructural properties, nanocrystallinity, and computational calculation-based electric field distributions of the cellulose-originated AuNPs were optimized to maximize LSPR phenomena and then characterized. Additionally, the performance of the SERS biosensor was compared under two representative excitation laser sources in the visible region (532 nm) and near-infrared region (785 nm). The Raman activities of our SERS biosensor chip were evaluated by trace small molecules (crystal violet, 2 µL), and the biosensor achieved an enhancement factor of 3.29 × 109 for the analytic concept with an excellent reproducibility of 8.5% relative standard deviation and a detection limit of 0.74 pM. Furthermore, the experimental results revealed that the five proposed SERS-based biomarkers could provide important information for identifying and predicting SAH-induced cerebral vasospasm and hydrocephalus complications (91.1% reliability and 19.3% reproducibility). Therefore, this facile and effective principle of our SERS biosensor chip may inspire the basis and strategies for the development of sensing platforms to predict critical complications in various neurosurgical diagnoses. [Display omitted] •Bare cellulose at pH 3 showed the lowest negative electric potential, ξ = –30.7 mV.•A pH adjustment led to improved SERS performance of the cellulose biosensor chip.•Five SERS-based biomarkers were proposed to predict SAH-induced complications.</description><identifier>ISSN: 0956-5663</identifier><identifier>EISSN: 1873-4235</identifier><identifier>DOI: 10.1016/j.bios.2018.04.003</identifier><identifier>PMID: 29649653</identifier><language>eng</language><publisher>England: Elsevier B.V</publisher><subject>Cerebrospinal fluid ; Gold nanoparticles ; pH-adjusted cellulose strip ; SERS biosensor ; Subarachnoid hemorrhage ; Surface-enhanced Raman spectroscopy</subject><ispartof>Biosensors &amp; bioelectronics, 2018-07, Vol.111, p.59-65</ispartof><rights>2018 Elsevier B.V.</rights><rights>Copyright © 2018 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c393t-c64d0aa6310e5b7a3da83d406a043d7c7415de046102d7f6b0f595e0fc6ca6dd3</citedby><cites>FETCH-LOGICAL-c393t-c64d0aa6310e5b7a3da83d406a043d7c7415de046102d7f6b0f595e0fc6ca6dd3</cites><orcidid>0000-0001-9186-6448</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.bios.2018.04.003$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29649653$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kim, Wansun</creatorcontrib><creatorcontrib>Lee, Sung Ho</creatorcontrib><creatorcontrib>Ahn, Yong Jin</creatorcontrib><creatorcontrib>Lee, Seung Ho</creatorcontrib><creatorcontrib>Ryu, Jiwook</creatorcontrib><creatorcontrib>Choi, Seok Keun</creatorcontrib><creatorcontrib>Choi, Samjin</creatorcontrib><title>A label-free cellulose SERS biosensor chip with improvement of nanoparticle-enhanced LSPR effects for early diagnosis of subarachnoid hemorrhage-induced complications</title><title>Biosensors &amp; bioelectronics</title><addtitle>Biosens Bioelectron</addtitle><description>It is very difficult to predict some complications after subarachnoid hemorrhage (SAH), despite rapid advances in medical science. Herein, we introduce a label-free cellulose surface-enhanced Raman spectroscopy (SERS) biosensor chip with pH-functionalized, gold nanoparticle (AuNP)-enhanced localized surface plasmon resonance (LSPR) effects for identification of SAH-induced cerebral vasospasm and hydrocephalus caused by cerebrospinal fluid (CSF). The SERS biosensor chip was implemented by the synthesis reaction of the AuNPs, which were charged positively through pH level adjustment, onto a negatively-charged cellulose substrate with ξ = –30.7 mV. The zeta potential, nanostructural properties, nanocrystallinity, and computational calculation-based electric field distributions of the cellulose-originated AuNPs were optimized to maximize LSPR phenomena and then characterized. Additionally, the performance of the SERS biosensor was compared under two representative excitation laser sources in the visible region (532 nm) and near-infrared region (785 nm). The Raman activities of our SERS biosensor chip were evaluated by trace small molecules (crystal violet, 2 µL), and the biosensor achieved an enhancement factor of 3.29 × 109 for the analytic concept with an excellent reproducibility of 8.5% relative standard deviation and a detection limit of 0.74 pM. Furthermore, the experimental results revealed that the five proposed SERS-based biomarkers could provide important information for identifying and predicting SAH-induced cerebral vasospasm and hydrocephalus complications (91.1% reliability and 19.3% reproducibility). Therefore, this facile and effective principle of our SERS biosensor chip may inspire the basis and strategies for the development of sensing platforms to predict critical complications in various neurosurgical diagnoses. [Display omitted] •Bare cellulose at pH 3 showed the lowest negative electric potential, ξ = –30.7 mV.•A pH adjustment led to improved SERS performance of the cellulose biosensor chip.•Five SERS-based biomarkers were proposed to predict SAH-induced complications.</description><subject>Cerebrospinal fluid</subject><subject>Gold nanoparticles</subject><subject>pH-adjusted cellulose strip</subject><subject>SERS biosensor</subject><subject>Subarachnoid hemorrhage</subject><subject>Surface-enhanced Raman spectroscopy</subject><issn>0956-5663</issn><issn>1873-4235</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp9kc1u1DAUhS0EokPhBVggL9kkXMexM5HYVFX5kUYCdWBtOfZ141FiBztp1RfiOUk0hSWruznnk-75CHnLoGTA5IdT2fmYywrYvoS6BODPyI7tG17UFRfPyQ5aIQshJb8gr3I-AUDDWnhJLqpW1q0UfEd-X9FBdzgULiFSg8OwDDEjPd7cHumGx5Bjoqb3E33wc0_9OKV4jyOGmUZHgw5x0mn2ZsACQ6-DQUsPx--3FJ1DM2fq1j7qNDxS6_VdiNnnrZmXTidt-hC9pT2OMaVe32Hhg102honjNHijZx9Dfk1eOD1kfPN0L8nPTzc_rr8Uh2-fv15fHQrDWz4XRtYWtJacAYqu0dzqPbc1SA01t41paiYsQi0ZVLZxsgMnWoHgjDRaWssvyfszd33y14J5VqPP2yo6YFyyqqASK5wJsUarc9SkmHNCp6bkR50eFQO1-VEntQ2oNj8KarX6WUvvnvhLN6L9V_krZA18PAdw_fLeY1LZeNxG9WldU9no_8f_A8dfpYI</recordid><startdate>20180715</startdate><enddate>20180715</enddate><creator>Kim, Wansun</creator><creator>Lee, Sung Ho</creator><creator>Ahn, Yong Jin</creator><creator>Lee, Seung Ho</creator><creator>Ryu, Jiwook</creator><creator>Choi, Seok Keun</creator><creator>Choi, Samjin</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-9186-6448</orcidid></search><sort><creationdate>20180715</creationdate><title>A label-free cellulose SERS biosensor chip with improvement of nanoparticle-enhanced LSPR effects for early diagnosis of subarachnoid hemorrhage-induced complications</title><author>Kim, Wansun ; Lee, Sung Ho ; Ahn, Yong Jin ; Lee, Seung Ho ; Ryu, Jiwook ; Choi, Seok Keun ; Choi, Samjin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c393t-c64d0aa6310e5b7a3da83d406a043d7c7415de046102d7f6b0f595e0fc6ca6dd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Cerebrospinal fluid</topic><topic>Gold nanoparticles</topic><topic>pH-adjusted cellulose strip</topic><topic>SERS biosensor</topic><topic>Subarachnoid hemorrhage</topic><topic>Surface-enhanced Raman spectroscopy</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kim, Wansun</creatorcontrib><creatorcontrib>Lee, Sung Ho</creatorcontrib><creatorcontrib>Ahn, Yong Jin</creatorcontrib><creatorcontrib>Lee, Seung Ho</creatorcontrib><creatorcontrib>Ryu, Jiwook</creatorcontrib><creatorcontrib>Choi, Seok Keun</creatorcontrib><creatorcontrib>Choi, Samjin</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Biosensors &amp; bioelectronics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kim, Wansun</au><au>Lee, Sung Ho</au><au>Ahn, Yong Jin</au><au>Lee, Seung Ho</au><au>Ryu, Jiwook</au><au>Choi, Seok Keun</au><au>Choi, Samjin</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A label-free cellulose SERS biosensor chip with improvement of nanoparticle-enhanced LSPR effects for early diagnosis of subarachnoid hemorrhage-induced complications</atitle><jtitle>Biosensors &amp; bioelectronics</jtitle><addtitle>Biosens Bioelectron</addtitle><date>2018-07-15</date><risdate>2018</risdate><volume>111</volume><spage>59</spage><epage>65</epage><pages>59-65</pages><issn>0956-5663</issn><eissn>1873-4235</eissn><abstract>It is very difficult to predict some complications after subarachnoid hemorrhage (SAH), despite rapid advances in medical science. Herein, we introduce a label-free cellulose surface-enhanced Raman spectroscopy (SERS) biosensor chip with pH-functionalized, gold nanoparticle (AuNP)-enhanced localized surface plasmon resonance (LSPR) effects for identification of SAH-induced cerebral vasospasm and hydrocephalus caused by cerebrospinal fluid (CSF). The SERS biosensor chip was implemented by the synthesis reaction of the AuNPs, which were charged positively through pH level adjustment, onto a negatively-charged cellulose substrate with ξ = –30.7 mV. The zeta potential, nanostructural properties, nanocrystallinity, and computational calculation-based electric field distributions of the cellulose-originated AuNPs were optimized to maximize LSPR phenomena and then characterized. Additionally, the performance of the SERS biosensor was compared under two representative excitation laser sources in the visible region (532 nm) and near-infrared region (785 nm). The Raman activities of our SERS biosensor chip were evaluated by trace small molecules (crystal violet, 2 µL), and the biosensor achieved an enhancement factor of 3.29 × 109 for the analytic concept with an excellent reproducibility of 8.5% relative standard deviation and a detection limit of 0.74 pM. Furthermore, the experimental results revealed that the five proposed SERS-based biomarkers could provide important information for identifying and predicting SAH-induced cerebral vasospasm and hydrocephalus complications (91.1% reliability and 19.3% reproducibility). Therefore, this facile and effective principle of our SERS biosensor chip may inspire the basis and strategies for the development of sensing platforms to predict critical complications in various neurosurgical diagnoses. [Display omitted] •Bare cellulose at pH 3 showed the lowest negative electric potential, ξ = –30.7 mV.•A pH adjustment led to improved SERS performance of the cellulose biosensor chip.•Five SERS-based biomarkers were proposed to predict SAH-induced complications.</abstract><cop>England</cop><pub>Elsevier B.V</pub><pmid>29649653</pmid><doi>10.1016/j.bios.2018.04.003</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0001-9186-6448</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0956-5663
ispartof Biosensors & bioelectronics, 2018-07, Vol.111, p.59-65
issn 0956-5663
1873-4235
language eng
recordid cdi_proquest_miscellaneous_2025310155
source Elsevier ScienceDirect Journals Complete
subjects Cerebrospinal fluid
Gold nanoparticles
pH-adjusted cellulose strip
SERS biosensor
Subarachnoid hemorrhage
Surface-enhanced Raman spectroscopy
title A label-free cellulose SERS biosensor chip with improvement of nanoparticle-enhanced LSPR effects for early diagnosis of subarachnoid hemorrhage-induced complications
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T09%3A10%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20label-free%20cellulose%20SERS%20biosensor%20chip%20with%20improvement%20of%20nanoparticle-enhanced%20LSPR%20effects%20for%20early%20diagnosis%20of%20subarachnoid%20hemorrhage-induced%20complications&rft.jtitle=Biosensors%20&%20bioelectronics&rft.au=Kim,%20Wansun&rft.date=2018-07-15&rft.volume=111&rft.spage=59&rft.epage=65&rft.pages=59-65&rft.issn=0956-5663&rft.eissn=1873-4235&rft_id=info:doi/10.1016/j.bios.2018.04.003&rft_dat=%3Cproquest_cross%3E2025310155%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2025310155&rft_id=info:pmid/29649653&rft_els_id=S0956566318302574&rfr_iscdi=true