Pupillometer Use: Validation for Use in Military and Occupational Medical Surveillance and Response to Organophosphate and Chemical Warfare Agent Exposure

To analyze the effectiveness and suitability of pupillometer use in military and occupational medicine, specifically when pupil size is measured as part of medical surveillance. Pupil size is the most sensitive physical exam finding in vapor exposure to substances that inhibit acetylcholinesterase,...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Military medicine 2018-09, Vol.183 (9-10), p.e291-e296
Hauptverfasser: Mease, Luke, Sikka, Reema, Rhees, Randall
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page e296
container_issue 9-10
container_start_page e291
container_title Military medicine
container_volume 183
creator Mease, Luke
Sikka, Reema
Rhees, Randall
description To analyze the effectiveness and suitability of pupillometer use in military and occupational medicine, specifically when pupil size is measured as part of medical surveillance. Pupil size is the most sensitive physical exam finding in vapor exposure to substances that inhibit acetylcholinesterase, such as nerve agent (chemical warfare) and organophosphates (used in agriculture). Pupillometer use permits real-time, accurate pupil measurements, which are of significant value in occupational setting where exposure to organophosphates is suspected and in dynamic military settings where it may be unclear if service members were exposed to nerve agent or not. In a worker population enrolled in medical surveillance including pupil size measurement, pupils were measured using a Colvard pupillometer, whereas their pupil size had previously been measured by manual measurement. Pupil size was compared pre- and post-pupillometer implementation. Pupil size range was broader post-pupillometer implementation, reflecting accepted ranges of physiologically normal pupil sizes. The correlation between pupil sizes pre- and post-pupillometer was low, and the overall mean pupil diameters were statistically different between the two modalities (p < 0.0001), strongly suggesting that pupillometer use helped correct inaccurate pupil size estimates. In two real-world situations, pupillometer use proved helpful in evaluating workers who may have been exposed to an organophosphate, providing information that was immediately available and clinically relevant as part of the initial medical evaluation/physical exam. Pupillometer use is feasible and robustly increases the precision and accuracy of pupil size measurement in military and occupational medicine settings caring for workers potentially exposed to organophosphates. It provides near-real-time quantitative data that are immediately pertinent to determining if a service member or employee has been exposed to these agents.
doi_str_mv 10.1093/milmed/usy011
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2014951792</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2430099509</sourcerecordid><originalsourceid>FETCH-LOGICAL-c388t-d5bacc9e90dfec2bc220dc1f1b61f9172fb4f0b1ae706b3a1fb02e85c5e968cb3</originalsourceid><addsrcrecordid>eNp9kc1O3DAUhS3UCgbaJdvKUjdsUvyTP3eHRkArgQZRoOwi27lmjJI42HFVXqVPW88ENixYXen6u0fy-RA6pOQbJYIf97broT2O4ZlQuoMWVHCSlZTff0ALQliZ5aQq9tB-CI-E0FzUdBftMVHklajFAv27iqPtOtfDBB7fBviO72RnWzlZN2DjtjtsB3xpOztJ_4zl0OKV1nHcIrLDl9Baneav6P9AypKDhi11DWF0QzqfHF75Bzm4ce3CuJbT_L5cQ7-9_C29kR7wyQMMEz79O7oQPXxCH43sAnx-mQfo9uz0Zvkju1id_1yeXGSa1_WUtYWSWgsQpDWgmdKMkVZTQ1VJjaAVMyo3RFEJFSkVl9QowqAudAGirLXiB-hozh29e4oQpqa3QcPmI-BiaNimtoJWgiX06xv00UWfSkhUzgkRokhO3qNoWYuyFLxOVDZT2rsQPJhm9LZPDTeUNBu1zay2mdUm_stLalSb9Sv96pL_B9rNpFE</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2168966938</pqid></control><display><type>article</type><title>Pupillometer Use: Validation for Use in Military and Occupational Medical Surveillance and Response to Organophosphate and Chemical Warfare Agent Exposure</title><source>EZB-FREE-00999 freely available EZB journals</source><source>Oxford Journals</source><creator>Mease, Luke ; Sikka, Reema ; Rhees, Randall</creator><creatorcontrib>Mease, Luke ; Sikka, Reema ; Rhees, Randall</creatorcontrib><description>To analyze the effectiveness and suitability of pupillometer use in military and occupational medicine, specifically when pupil size is measured as part of medical surveillance. Pupil size is the most sensitive physical exam finding in vapor exposure to substances that inhibit acetylcholinesterase, such as nerve agent (chemical warfare) and organophosphates (used in agriculture). Pupillometer use permits real-time, accurate pupil measurements, which are of significant value in occupational setting where exposure to organophosphates is suspected and in dynamic military settings where it may be unclear if service members were exposed to nerve agent or not. In a worker population enrolled in medical surveillance including pupil size measurement, pupils were measured using a Colvard pupillometer, whereas their pupil size had previously been measured by manual measurement. Pupil size was compared pre- and post-pupillometer implementation. Pupil size range was broader post-pupillometer implementation, reflecting accepted ranges of physiologically normal pupil sizes. The correlation between pupil sizes pre- and post-pupillometer was low, and the overall mean pupil diameters were statistically different between the two modalities (p &lt; 0.0001), strongly suggesting that pupillometer use helped correct inaccurate pupil size estimates. In two real-world situations, pupillometer use proved helpful in evaluating workers who may have been exposed to an organophosphate, providing information that was immediately available and clinically relevant as part of the initial medical evaluation/physical exam. Pupillometer use is feasible and robustly increases the precision and accuracy of pupil size measurement in military and occupational medicine settings caring for workers potentially exposed to organophosphates. It provides near-real-time quantitative data that are immediately pertinent to determining if a service member or employee has been exposed to these agents.</description><identifier>ISSN: 0026-4075</identifier><identifier>EISSN: 1930-613X</identifier><identifier>DOI: 10.1093/milmed/usy011</identifier><identifier>PMID: 29547989</identifier><language>eng</language><publisher>England: Oxford University Press</publisher><subject>Automation ; Biological &amp; chemical weapons ; Cataracts ; Occupational health ; Studies ; Workers</subject><ispartof>Military medicine, 2018-09, Vol.183 (9-10), p.e291-e296</ispartof><rights>Published by Oxford University Press on behalf of the Association of Military Surgeons of the United States 2018.</rights><rights>Copyright Oxford University Press Sep/Oct 2018</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c388t-d5bacc9e90dfec2bc220dc1f1b61f9172fb4f0b1ae706b3a1fb02e85c5e968cb3</citedby><cites>FETCH-LOGICAL-c388t-d5bacc9e90dfec2bc220dc1f1b61f9172fb4f0b1ae706b3a1fb02e85c5e968cb3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29547989$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Mease, Luke</creatorcontrib><creatorcontrib>Sikka, Reema</creatorcontrib><creatorcontrib>Rhees, Randall</creatorcontrib><title>Pupillometer Use: Validation for Use in Military and Occupational Medical Surveillance and Response to Organophosphate and Chemical Warfare Agent Exposure</title><title>Military medicine</title><addtitle>Mil Med</addtitle><description>To analyze the effectiveness and suitability of pupillometer use in military and occupational medicine, specifically when pupil size is measured as part of medical surveillance. Pupil size is the most sensitive physical exam finding in vapor exposure to substances that inhibit acetylcholinesterase, such as nerve agent (chemical warfare) and organophosphates (used in agriculture). Pupillometer use permits real-time, accurate pupil measurements, which are of significant value in occupational setting where exposure to organophosphates is suspected and in dynamic military settings where it may be unclear if service members were exposed to nerve agent or not. In a worker population enrolled in medical surveillance including pupil size measurement, pupils were measured using a Colvard pupillometer, whereas their pupil size had previously been measured by manual measurement. Pupil size was compared pre- and post-pupillometer implementation. Pupil size range was broader post-pupillometer implementation, reflecting accepted ranges of physiologically normal pupil sizes. The correlation between pupil sizes pre- and post-pupillometer was low, and the overall mean pupil diameters were statistically different between the two modalities (p &lt; 0.0001), strongly suggesting that pupillometer use helped correct inaccurate pupil size estimates. In two real-world situations, pupillometer use proved helpful in evaluating workers who may have been exposed to an organophosphate, providing information that was immediately available and clinically relevant as part of the initial medical evaluation/physical exam. Pupillometer use is feasible and robustly increases the precision and accuracy of pupil size measurement in military and occupational medicine settings caring for workers potentially exposed to organophosphates. It provides near-real-time quantitative data that are immediately pertinent to determining if a service member or employee has been exposed to these agents.</description><subject>Automation</subject><subject>Biological &amp; chemical weapons</subject><subject>Cataracts</subject><subject>Occupational health</subject><subject>Studies</subject><subject>Workers</subject><issn>0026-4075</issn><issn>1930-613X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp9kc1O3DAUhS3UCgbaJdvKUjdsUvyTP3eHRkArgQZRoOwi27lmjJI42HFVXqVPW88ENixYXen6u0fy-RA6pOQbJYIf97broT2O4ZlQuoMWVHCSlZTff0ALQliZ5aQq9tB-CI-E0FzUdBftMVHklajFAv27iqPtOtfDBB7fBviO72RnWzlZN2DjtjtsB3xpOztJ_4zl0OKV1nHcIrLDl9Baneav6P9AypKDhi11DWF0QzqfHF75Bzm4ce3CuJbT_L5cQ7-9_C29kR7wyQMMEz79O7oQPXxCH43sAnx-mQfo9uz0Zvkju1id_1yeXGSa1_WUtYWSWgsQpDWgmdKMkVZTQ1VJjaAVMyo3RFEJFSkVl9QowqAudAGirLXiB-hozh29e4oQpqa3QcPmI-BiaNimtoJWgiX06xv00UWfSkhUzgkRokhO3qNoWYuyFLxOVDZT2rsQPJhm9LZPDTeUNBu1zay2mdUm_stLalSb9Sv96pL_B9rNpFE</recordid><startdate>20180901</startdate><enddate>20180901</enddate><creator>Mease, Luke</creator><creator>Sikka, Reema</creator><creator>Rhees, Randall</creator><general>Oxford University Press</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>4T-</scope><scope>K9.</scope><scope>NAPCQ</scope><scope>7X8</scope></search><sort><creationdate>20180901</creationdate><title>Pupillometer Use: Validation for Use in Military and Occupational Medical Surveillance and Response to Organophosphate and Chemical Warfare Agent Exposure</title><author>Mease, Luke ; Sikka, Reema ; Rhees, Randall</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c388t-d5bacc9e90dfec2bc220dc1f1b61f9172fb4f0b1ae706b3a1fb02e85c5e968cb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Automation</topic><topic>Biological &amp; chemical weapons</topic><topic>Cataracts</topic><topic>Occupational health</topic><topic>Studies</topic><topic>Workers</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mease, Luke</creatorcontrib><creatorcontrib>Sikka, Reema</creatorcontrib><creatorcontrib>Rhees, Randall</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Docstoc</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>MEDLINE - Academic</collection><jtitle>Military medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mease, Luke</au><au>Sikka, Reema</au><au>Rhees, Randall</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Pupillometer Use: Validation for Use in Military and Occupational Medical Surveillance and Response to Organophosphate and Chemical Warfare Agent Exposure</atitle><jtitle>Military medicine</jtitle><addtitle>Mil Med</addtitle><date>2018-09-01</date><risdate>2018</risdate><volume>183</volume><issue>9-10</issue><spage>e291</spage><epage>e296</epage><pages>e291-e296</pages><issn>0026-4075</issn><eissn>1930-613X</eissn><abstract>To analyze the effectiveness and suitability of pupillometer use in military and occupational medicine, specifically when pupil size is measured as part of medical surveillance. Pupil size is the most sensitive physical exam finding in vapor exposure to substances that inhibit acetylcholinesterase, such as nerve agent (chemical warfare) and organophosphates (used in agriculture). Pupillometer use permits real-time, accurate pupil measurements, which are of significant value in occupational setting where exposure to organophosphates is suspected and in dynamic military settings where it may be unclear if service members were exposed to nerve agent or not. In a worker population enrolled in medical surveillance including pupil size measurement, pupils were measured using a Colvard pupillometer, whereas their pupil size had previously been measured by manual measurement. Pupil size was compared pre- and post-pupillometer implementation. Pupil size range was broader post-pupillometer implementation, reflecting accepted ranges of physiologically normal pupil sizes. The correlation between pupil sizes pre- and post-pupillometer was low, and the overall mean pupil diameters were statistically different between the two modalities (p &lt; 0.0001), strongly suggesting that pupillometer use helped correct inaccurate pupil size estimates. In two real-world situations, pupillometer use proved helpful in evaluating workers who may have been exposed to an organophosphate, providing information that was immediately available and clinically relevant as part of the initial medical evaluation/physical exam. Pupillometer use is feasible and robustly increases the precision and accuracy of pupil size measurement in military and occupational medicine settings caring for workers potentially exposed to organophosphates. It provides near-real-time quantitative data that are immediately pertinent to determining if a service member or employee has been exposed to these agents.</abstract><cop>England</cop><pub>Oxford University Press</pub><pmid>29547989</pmid><doi>10.1093/milmed/usy011</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0026-4075
ispartof Military medicine, 2018-09, Vol.183 (9-10), p.e291-e296
issn 0026-4075
1930-613X
language eng
recordid cdi_proquest_miscellaneous_2014951792
source EZB-FREE-00999 freely available EZB journals; Oxford Journals
subjects Automation
Biological & chemical weapons
Cataracts
Occupational health
Studies
Workers
title Pupillometer Use: Validation for Use in Military and Occupational Medical Surveillance and Response to Organophosphate and Chemical Warfare Agent Exposure
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T21%3A05%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Pupillometer%20Use:%20Validation%20for%20Use%20in%20Military%20and%20Occupational%20Medical%20Surveillance%20and%20Response%20to%20Organophosphate%20and%20Chemical%20Warfare%20Agent%20Exposure&rft.jtitle=Military%20medicine&rft.au=Mease,%20Luke&rft.date=2018-09-01&rft.volume=183&rft.issue=9-10&rft.spage=e291&rft.epage=e296&rft.pages=e291-e296&rft.issn=0026-4075&rft.eissn=1930-613X&rft_id=info:doi/10.1093/milmed/usy011&rft_dat=%3Cproquest_cross%3E2430099509%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2168966938&rft_id=info:pmid/29547989&rfr_iscdi=true