Creation of 3-Dimensional Life Size: Patient-Specific C1 Fracture Models for Screw Fixation

Transarticular screw fixation has fatal complications such as vertebral artery (VA), carotid artery, and spinal cord injuries. The landmarks for deciding the entry point for C1 lateral mass screws were clarified by using life-size 3-dimensional (3D) patient-specific spine models. This study included...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:World neurosurgery 2018-06, Vol.114, p.e173-e181
Hauptverfasser: Govsa, Figen, Ozer, Mehmet Asim, Biceroglu, Huseyin, Karakas, Asli Beril, Cagli, Sedat, Eraslan, Cenk, Alagoz, Ahmet Kemal
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page e181
container_issue
container_start_page e173
container_title World neurosurgery
container_volume 114
creator Govsa, Figen
Ozer, Mehmet Asim
Biceroglu, Huseyin
Karakas, Asli Beril
Cagli, Sedat
Eraslan, Cenk
Alagoz, Ahmet Kemal
description Transarticular screw fixation has fatal complications such as vertebral artery (VA), carotid artery, and spinal cord injuries. The landmarks for deciding the entry point for C1 lateral mass screws were clarified by using life-size 3-dimensional (3D) patient-specific spine models. This study included a total of 10 patients with C1 fractures. Dual-energy computed tomography (CT) scan data from C1 pre- and postscrewing were modified into 3D patient-specific life-size cervical spine models. The detailed information, such as bony and vascular elements, of 13 separate parameters of C1 was used as an intraoperative reference. 3D patient-specific models were created preoperatively with the fracture and postoperatively with the screwed vertebrae. After CT scans of the models were measured, the life-size patient-specific models were proven to be individualized. 3D models assisted in determining the fracture locations, pedicle sizes, and positions of the VA. The range of the measurements for ideal point of entry reveals the need for patient-specific intervention was required. 3D models were used in surgical planning maximizing the possibility of ideal screw position and providing individualized information concerning cervical spinal anatomy. The individualized 3D printing screw insertion template was user-friendly, of moderate cost, and it enabled a radiation-free cervical screw insertion. •C1 screws require analysis of the complex osteovascular structures of the personalized anatomical variations.•3D life-size models were assisted in determining the fracture location, pedicle size and VA shapes.•3D invidualized models are useful for neurosurgeons, improving an important supplement to their training and experience.•3D models are helping patients and their families to understand their cases, surgical goals and risks of the operation.
doi_str_mv 10.1016/j.wneu.2018.02.131
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2011615647</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1878875018304042</els_id><sourcerecordid>2011615647</sourcerecordid><originalsourceid>FETCH-LOGICAL-c356t-e9ab673c5efc8f16d0df56c5c31c88030a64fa97e038744c03098cf8f799e97a3</originalsourceid><addsrcrecordid>eNp9kMFOGzEQhq2qqESBF-ih8pHLLvZ61_ZWXFBKACmoldLeKllmdiw52uwGe7cBnqbPwpPhEJpj5-IZ6_v_w0fIZ85yzrg8X-XbDse8YFznrMi54B_IhGulM61k_fGwV-yYnMa4YmkEL7USn8hxUVecFVpOyO9ZQDv4vqO9oyL75tfYxXTali68Q7r0z_iV_kgIdkO23CB454HOOJ0HC8MYkN71DbaRuj7QJQTcvvyd-8e3zhNy5Gwb8fT9nZJf86ufs5ts8f36dna5yEBUcsiwtvdSCajQgXZcNqxxlYQKBAetmWBWls7WCpnQqiwh_dQanHaqrrFWVkzJ2b53E_qHEeNg1j4Ctq3tsB-jSZK45JUsVUKLPQqhjzGgM5vg1zY8Gc7MTqxZmZ3YXUYbVpgkNoW-vPeP92tsDpF_GhNwsQeSCPzjMZgISRhg4wPCYJre_6__FVXriW4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2011615647</pqid></control><display><type>article</type><title>Creation of 3-Dimensional Life Size: Patient-Specific C1 Fracture Models for Screw Fixation</title><source>Elsevier ScienceDirect Journals Complete - AutoHoldings</source><creator>Govsa, Figen ; Ozer, Mehmet Asim ; Biceroglu, Huseyin ; Karakas, Asli Beril ; Cagli, Sedat ; Eraslan, Cenk ; Alagoz, Ahmet Kemal</creator><creatorcontrib>Govsa, Figen ; Ozer, Mehmet Asim ; Biceroglu, Huseyin ; Karakas, Asli Beril ; Cagli, Sedat ; Eraslan, Cenk ; Alagoz, Ahmet Kemal</creatorcontrib><description>Transarticular screw fixation has fatal complications such as vertebral artery (VA), carotid artery, and spinal cord injuries. The landmarks for deciding the entry point for C1 lateral mass screws were clarified by using life-size 3-dimensional (3D) patient-specific spine models. This study included a total of 10 patients with C1 fractures. Dual-energy computed tomography (CT) scan data from C1 pre- and postscrewing were modified into 3D patient-specific life-size cervical spine models. The detailed information, such as bony and vascular elements, of 13 separate parameters of C1 was used as an intraoperative reference. 3D patient-specific models were created preoperatively with the fracture and postoperatively with the screwed vertebrae. After CT scans of the models were measured, the life-size patient-specific models were proven to be individualized. 3D models assisted in determining the fracture locations, pedicle sizes, and positions of the VA. The range of the measurements for ideal point of entry reveals the need for patient-specific intervention was required. 3D models were used in surgical planning maximizing the possibility of ideal screw position and providing individualized information concerning cervical spinal anatomy. The individualized 3D printing screw insertion template was user-friendly, of moderate cost, and it enabled a radiation-free cervical screw insertion. •C1 screws require analysis of the complex osteovascular structures of the personalized anatomical variations.•3D life-size models were assisted in determining the fracture location, pedicle size and VA shapes.•3D invidualized models are useful for neurosurgeons, improving an important supplement to their training and experience.•3D models are helping patients and their families to understand their cases, surgical goals and risks of the operation.</description><identifier>ISSN: 1878-8750</identifier><identifier>EISSN: 1878-8769</identifier><identifier>DOI: 10.1016/j.wneu.2018.02.131</identifier><identifier>PMID: 29510286</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>3D neuroanatomical model ; Individualized screw insertion ; Patient-specific model ; Transarticular screw fixation ; Vertebral artery</subject><ispartof>World neurosurgery, 2018-06, Vol.114, p.e173-e181</ispartof><rights>2018 Elsevier Inc.</rights><rights>Copyright © 2018 Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c356t-e9ab673c5efc8f16d0df56c5c31c88030a64fa97e038744c03098cf8f799e97a3</citedby><cites>FETCH-LOGICAL-c356t-e9ab673c5efc8f16d0df56c5c31c88030a64fa97e038744c03098cf8f799e97a3</cites><orcidid>0000-0001-9635-6308</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.wneu.2018.02.131$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3549,27923,27924,45994</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29510286$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Govsa, Figen</creatorcontrib><creatorcontrib>Ozer, Mehmet Asim</creatorcontrib><creatorcontrib>Biceroglu, Huseyin</creatorcontrib><creatorcontrib>Karakas, Asli Beril</creatorcontrib><creatorcontrib>Cagli, Sedat</creatorcontrib><creatorcontrib>Eraslan, Cenk</creatorcontrib><creatorcontrib>Alagoz, Ahmet Kemal</creatorcontrib><title>Creation of 3-Dimensional Life Size: Patient-Specific C1 Fracture Models for Screw Fixation</title><title>World neurosurgery</title><addtitle>World Neurosurg</addtitle><description>Transarticular screw fixation has fatal complications such as vertebral artery (VA), carotid artery, and spinal cord injuries. The landmarks for deciding the entry point for C1 lateral mass screws were clarified by using life-size 3-dimensional (3D) patient-specific spine models. This study included a total of 10 patients with C1 fractures. Dual-energy computed tomography (CT) scan data from C1 pre- and postscrewing were modified into 3D patient-specific life-size cervical spine models. The detailed information, such as bony and vascular elements, of 13 separate parameters of C1 was used as an intraoperative reference. 3D patient-specific models were created preoperatively with the fracture and postoperatively with the screwed vertebrae. After CT scans of the models were measured, the life-size patient-specific models were proven to be individualized. 3D models assisted in determining the fracture locations, pedicle sizes, and positions of the VA. The range of the measurements for ideal point of entry reveals the need for patient-specific intervention was required. 3D models were used in surgical planning maximizing the possibility of ideal screw position and providing individualized information concerning cervical spinal anatomy. The individualized 3D printing screw insertion template was user-friendly, of moderate cost, and it enabled a radiation-free cervical screw insertion. •C1 screws require analysis of the complex osteovascular structures of the personalized anatomical variations.•3D life-size models were assisted in determining the fracture location, pedicle size and VA shapes.•3D invidualized models are useful for neurosurgeons, improving an important supplement to their training and experience.•3D models are helping patients and their families to understand their cases, surgical goals and risks of the operation.</description><subject>3D neuroanatomical model</subject><subject>Individualized screw insertion</subject><subject>Patient-specific model</subject><subject>Transarticular screw fixation</subject><subject>Vertebral artery</subject><issn>1878-8750</issn><issn>1878-8769</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp9kMFOGzEQhq2qqESBF-ih8pHLLvZ61_ZWXFBKACmoldLeKllmdiw52uwGe7cBnqbPwpPhEJpj5-IZ6_v_w0fIZ85yzrg8X-XbDse8YFznrMi54B_IhGulM61k_fGwV-yYnMa4YmkEL7USn8hxUVecFVpOyO9ZQDv4vqO9oyL75tfYxXTali68Q7r0z_iV_kgIdkO23CB454HOOJ0HC8MYkN71DbaRuj7QJQTcvvyd-8e3zhNy5Gwb8fT9nZJf86ufs5ts8f36dna5yEBUcsiwtvdSCajQgXZcNqxxlYQKBAetmWBWls7WCpnQqiwh_dQanHaqrrFWVkzJ2b53E_qHEeNg1j4Ctq3tsB-jSZK45JUsVUKLPQqhjzGgM5vg1zY8Gc7MTqxZmZ3YXUYbVpgkNoW-vPeP92tsDpF_GhNwsQeSCPzjMZgISRhg4wPCYJre_6__FVXriW4</recordid><startdate>20180601</startdate><enddate>20180601</enddate><creator>Govsa, Figen</creator><creator>Ozer, Mehmet Asim</creator><creator>Biceroglu, Huseyin</creator><creator>Karakas, Asli Beril</creator><creator>Cagli, Sedat</creator><creator>Eraslan, Cenk</creator><creator>Alagoz, Ahmet Kemal</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-9635-6308</orcidid></search><sort><creationdate>20180601</creationdate><title>Creation of 3-Dimensional Life Size: Patient-Specific C1 Fracture Models for Screw Fixation</title><author>Govsa, Figen ; Ozer, Mehmet Asim ; Biceroglu, Huseyin ; Karakas, Asli Beril ; Cagli, Sedat ; Eraslan, Cenk ; Alagoz, Ahmet Kemal</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c356t-e9ab673c5efc8f16d0df56c5c31c88030a64fa97e038744c03098cf8f799e97a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>3D neuroanatomical model</topic><topic>Individualized screw insertion</topic><topic>Patient-specific model</topic><topic>Transarticular screw fixation</topic><topic>Vertebral artery</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Govsa, Figen</creatorcontrib><creatorcontrib>Ozer, Mehmet Asim</creatorcontrib><creatorcontrib>Biceroglu, Huseyin</creatorcontrib><creatorcontrib>Karakas, Asli Beril</creatorcontrib><creatorcontrib>Cagli, Sedat</creatorcontrib><creatorcontrib>Eraslan, Cenk</creatorcontrib><creatorcontrib>Alagoz, Ahmet Kemal</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>World neurosurgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Govsa, Figen</au><au>Ozer, Mehmet Asim</au><au>Biceroglu, Huseyin</au><au>Karakas, Asli Beril</au><au>Cagli, Sedat</au><au>Eraslan, Cenk</au><au>Alagoz, Ahmet Kemal</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Creation of 3-Dimensional Life Size: Patient-Specific C1 Fracture Models for Screw Fixation</atitle><jtitle>World neurosurgery</jtitle><addtitle>World Neurosurg</addtitle><date>2018-06-01</date><risdate>2018</risdate><volume>114</volume><spage>e173</spage><epage>e181</epage><pages>e173-e181</pages><issn>1878-8750</issn><eissn>1878-8769</eissn><abstract>Transarticular screw fixation has fatal complications such as vertebral artery (VA), carotid artery, and spinal cord injuries. The landmarks for deciding the entry point for C1 lateral mass screws were clarified by using life-size 3-dimensional (3D) patient-specific spine models. This study included a total of 10 patients with C1 fractures. Dual-energy computed tomography (CT) scan data from C1 pre- and postscrewing were modified into 3D patient-specific life-size cervical spine models. The detailed information, such as bony and vascular elements, of 13 separate parameters of C1 was used as an intraoperative reference. 3D patient-specific models were created preoperatively with the fracture and postoperatively with the screwed vertebrae. After CT scans of the models were measured, the life-size patient-specific models were proven to be individualized. 3D models assisted in determining the fracture locations, pedicle sizes, and positions of the VA. The range of the measurements for ideal point of entry reveals the need for patient-specific intervention was required. 3D models were used in surgical planning maximizing the possibility of ideal screw position and providing individualized information concerning cervical spinal anatomy. The individualized 3D printing screw insertion template was user-friendly, of moderate cost, and it enabled a radiation-free cervical screw insertion. •C1 screws require analysis of the complex osteovascular structures of the personalized anatomical variations.•3D life-size models were assisted in determining the fracture location, pedicle size and VA shapes.•3D invidualized models are useful for neurosurgeons, improving an important supplement to their training and experience.•3D models are helping patients and their families to understand their cases, surgical goals and risks of the operation.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>29510286</pmid><doi>10.1016/j.wneu.2018.02.131</doi><orcidid>https://orcid.org/0000-0001-9635-6308</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1878-8750
ispartof World neurosurgery, 2018-06, Vol.114, p.e173-e181
issn 1878-8750
1878-8769
language eng
recordid cdi_proquest_miscellaneous_2011615647
source Elsevier ScienceDirect Journals Complete - AutoHoldings
subjects 3D neuroanatomical model
Individualized screw insertion
Patient-specific model
Transarticular screw fixation
Vertebral artery
title Creation of 3-Dimensional Life Size: Patient-Specific C1 Fracture Models for Screw Fixation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T08%3A44%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Creation%20of%203-Dimensional%20Life%20Size:%20Patient-Specific%20C1%20Fracture%20Models%20for%20Screw%C2%A0Fixation&rft.jtitle=World%20neurosurgery&rft.au=Govsa,%20Figen&rft.date=2018-06-01&rft.volume=114&rft.spage=e173&rft.epage=e181&rft.pages=e173-e181&rft.issn=1878-8750&rft.eissn=1878-8769&rft_id=info:doi/10.1016/j.wneu.2018.02.131&rft_dat=%3Cproquest_cross%3E2011615647%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2011615647&rft_id=info:pmid/29510286&rft_els_id=S1878875018304042&rfr_iscdi=true