EVALUATION OF PATIENT EXPOSURE IN FAST kVp SWITCHING DUAL ENERGY COMPUTED TOMOGRAPHY: PHANTOM STUDY

The aim of this study was to evaluate the suitability of size specific dose estimates (SSDE) to estimate patient dose in Fast kVp switching dual energy CT. An anthropomorphic phantom (RAN-110) was repeatedly scanned (chest, abdomen and the pelvis) using a 64 detector row MDCT (Discovery CT750 HD, GE...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Radiation protection dosimetry 2018-10, Vol.181 (3), p.261-268
Hauptverfasser: Yagami, K, Miyoshi, T, Shigeyama, S, Takai, H, Tsukahara, Y, Matsumoto, K, Suzuki, R, Yasuda, N, Okada, H, Suzuki, S, Foley, S J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 268
container_issue 3
container_start_page 261
container_title Radiation protection dosimetry
container_volume 181
creator Yagami, K
Miyoshi, T
Shigeyama, S
Takai, H
Tsukahara, Y
Matsumoto, K
Suzuki, R
Yasuda, N
Okada, H
Suzuki, S
Foley, S J
description The aim of this study was to evaluate the suitability of size specific dose estimates (SSDE) to estimate patient dose in Fast kVp switching dual energy CT. An anthropomorphic phantom (RAN-110) was repeatedly scanned (chest, abdomen and the pelvis) using a 64 detector row MDCT (Discovery CT750 HD, GE Healthcare, Milwaukee, WI, USA) with various CT parameters, including Fast kVp switching. Dosimetry was performed using thermo-luminescent dosimeters, positioned both superficially and within the phantom. SSDE was calculated for all slices of the anthropomorphic phantom using both the localiser and axial images. In Fast kVp switching, SSDE underestimated the measured absorbed dose for the chest/abdomen region ~35% at the maximum, but were in closer agreement for the pelvic region about within 10%. In single energy techniques, SSDE could not be applied in the estimation of organ doses, but in Fast kVp switching dual energy techniques, SSDE could be applied for anatomical regions with larger thicknesses.
doi_str_mv 10.1093/rpd/ncy022
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2007116872</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2007116872</sourcerecordid><originalsourceid>FETCH-LOGICAL-c287t-b6cf75326c3a969686c7f0e7c0a97810df424121821c99c898844a37cf74dcd33</originalsourceid><addsrcrecordid>eNo9kMtOwkAUQCdGI4hu_AAzS2NSmRfzcNfAUJqUtqEtyqop0zZBedmBBX9vDejq3pucexYHgEeMXjFStN_sy_7WnBAhV6CLBSMOZYhfgy7CjDmSEdQBd9Z-IkSEGrBb0CGKccKE6gKj526QuakfhTAaw7jddJhC_RFHSTbT0A_h2E1S-DXfw-TdT4cTP_TgKHMDqEM98xZwGE3jLNUjmEbTyJu58WTxBuOJG7Y3TNJstLgHN3WxttXDZfZANtatyQkizx-6gWOIFAdnyU0tBpRwQwvFFZfciBpVwqBCCYlRWTPCMMGSYKOUkUpKxgoq2i9WmpLSHng-e_fN7vtY2UO-WVlTrdfFttodbU4QEhhzKUiLvpxR0-ysbao63zerTdGccozy36h5GzU_R23hp4v3uNxU5T_6V5H-AEYUam0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2007116872</pqid></control><display><type>article</type><title>EVALUATION OF PATIENT EXPOSURE IN FAST kVp SWITCHING DUAL ENERGY COMPUTED TOMOGRAPHY: PHANTOM STUDY</title><source>MEDLINE</source><source>Oxford University Press Journals All Titles (1996-Current)</source><source>Alma/SFX Local Collection</source><creator>Yagami, K ; Miyoshi, T ; Shigeyama, S ; Takai, H ; Tsukahara, Y ; Matsumoto, K ; Suzuki, R ; Yasuda, N ; Okada, H ; Suzuki, S ; Foley, S J</creator><creatorcontrib>Yagami, K ; Miyoshi, T ; Shigeyama, S ; Takai, H ; Tsukahara, Y ; Matsumoto, K ; Suzuki, R ; Yasuda, N ; Okada, H ; Suzuki, S ; Foley, S J</creatorcontrib><description>The aim of this study was to evaluate the suitability of size specific dose estimates (SSDE) to estimate patient dose in Fast kVp switching dual energy CT. An anthropomorphic phantom (RAN-110) was repeatedly scanned (chest, abdomen and the pelvis) using a 64 detector row MDCT (Discovery CT750 HD, GE Healthcare, Milwaukee, WI, USA) with various CT parameters, including Fast kVp switching. Dosimetry was performed using thermo-luminescent dosimeters, positioned both superficially and within the phantom. SSDE was calculated for all slices of the anthropomorphic phantom using both the localiser and axial images. In Fast kVp switching, SSDE underestimated the measured absorbed dose for the chest/abdomen region ~35% at the maximum, but were in closer agreement for the pelvic region about within 10%. In single energy techniques, SSDE could not be applied in the estimation of organ doses, but in Fast kVp switching dual energy techniques, SSDE could be applied for anatomical regions with larger thicknesses.</description><identifier>ISSN: 0144-8420</identifier><identifier>EISSN: 1742-3406</identifier><identifier>DOI: 10.1093/rpd/ncy022</identifier><identifier>PMID: 29462479</identifier><language>eng</language><publisher>England</publisher><subject>Abdomen - radiation effects ; Humans ; Pelvis - radiation effects ; Phantoms, Imaging ; Radiation Dosage ; Radiation Monitoring ; Radiography, Dual-Energy Scanned Projection - methods ; Radiography, Thoracic ; Tomography, X-Ray Computed - methods</subject><ispartof>Radiation protection dosimetry, 2018-10, Vol.181 (3), p.261-268</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c287t-b6cf75326c3a969686c7f0e7c0a97810df424121821c99c898844a37cf74dcd33</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29462479$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Yagami, K</creatorcontrib><creatorcontrib>Miyoshi, T</creatorcontrib><creatorcontrib>Shigeyama, S</creatorcontrib><creatorcontrib>Takai, H</creatorcontrib><creatorcontrib>Tsukahara, Y</creatorcontrib><creatorcontrib>Matsumoto, K</creatorcontrib><creatorcontrib>Suzuki, R</creatorcontrib><creatorcontrib>Yasuda, N</creatorcontrib><creatorcontrib>Okada, H</creatorcontrib><creatorcontrib>Suzuki, S</creatorcontrib><creatorcontrib>Foley, S J</creatorcontrib><title>EVALUATION OF PATIENT EXPOSURE IN FAST kVp SWITCHING DUAL ENERGY COMPUTED TOMOGRAPHY: PHANTOM STUDY</title><title>Radiation protection dosimetry</title><addtitle>Radiat Prot Dosimetry</addtitle><description>The aim of this study was to evaluate the suitability of size specific dose estimates (SSDE) to estimate patient dose in Fast kVp switching dual energy CT. An anthropomorphic phantom (RAN-110) was repeatedly scanned (chest, abdomen and the pelvis) using a 64 detector row MDCT (Discovery CT750 HD, GE Healthcare, Milwaukee, WI, USA) with various CT parameters, including Fast kVp switching. Dosimetry was performed using thermo-luminescent dosimeters, positioned both superficially and within the phantom. SSDE was calculated for all slices of the anthropomorphic phantom using both the localiser and axial images. In Fast kVp switching, SSDE underestimated the measured absorbed dose for the chest/abdomen region ~35% at the maximum, but were in closer agreement for the pelvic region about within 10%. In single energy techniques, SSDE could not be applied in the estimation of organ doses, but in Fast kVp switching dual energy techniques, SSDE could be applied for anatomical regions with larger thicknesses.</description><subject>Abdomen - radiation effects</subject><subject>Humans</subject><subject>Pelvis - radiation effects</subject><subject>Phantoms, Imaging</subject><subject>Radiation Dosage</subject><subject>Radiation Monitoring</subject><subject>Radiography, Dual-Energy Scanned Projection - methods</subject><subject>Radiography, Thoracic</subject><subject>Tomography, X-Ray Computed - methods</subject><issn>0144-8420</issn><issn>1742-3406</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kMtOwkAUQCdGI4hu_AAzS2NSmRfzcNfAUJqUtqEtyqop0zZBedmBBX9vDejq3pucexYHgEeMXjFStN_sy_7WnBAhV6CLBSMOZYhfgy7CjDmSEdQBd9Z-IkSEGrBb0CGKccKE6gKj526QuakfhTAaw7jddJhC_RFHSTbT0A_h2E1S-DXfw-TdT4cTP_TgKHMDqEM98xZwGE3jLNUjmEbTyJu58WTxBuOJG7Y3TNJstLgHN3WxttXDZfZANtatyQkizx-6gWOIFAdnyU0tBpRwQwvFFZfciBpVwqBCCYlRWTPCMMGSYKOUkUpKxgoq2i9WmpLSHng-e_fN7vtY2UO-WVlTrdfFttodbU4QEhhzKUiLvpxR0-ysbao63zerTdGccozy36h5GzU_R23hp4v3uNxU5T_6V5H-AEYUam0</recordid><startdate>20181001</startdate><enddate>20181001</enddate><creator>Yagami, K</creator><creator>Miyoshi, T</creator><creator>Shigeyama, S</creator><creator>Takai, H</creator><creator>Tsukahara, Y</creator><creator>Matsumoto, K</creator><creator>Suzuki, R</creator><creator>Yasuda, N</creator><creator>Okada, H</creator><creator>Suzuki, S</creator><creator>Foley, S J</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20181001</creationdate><title>EVALUATION OF PATIENT EXPOSURE IN FAST kVp SWITCHING DUAL ENERGY COMPUTED TOMOGRAPHY: PHANTOM STUDY</title><author>Yagami, K ; Miyoshi, T ; Shigeyama, S ; Takai, H ; Tsukahara, Y ; Matsumoto, K ; Suzuki, R ; Yasuda, N ; Okada, H ; Suzuki, S ; Foley, S J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c287t-b6cf75326c3a969686c7f0e7c0a97810df424121821c99c898844a37cf74dcd33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Abdomen - radiation effects</topic><topic>Humans</topic><topic>Pelvis - radiation effects</topic><topic>Phantoms, Imaging</topic><topic>Radiation Dosage</topic><topic>Radiation Monitoring</topic><topic>Radiography, Dual-Energy Scanned Projection - methods</topic><topic>Radiography, Thoracic</topic><topic>Tomography, X-Ray Computed - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yagami, K</creatorcontrib><creatorcontrib>Miyoshi, T</creatorcontrib><creatorcontrib>Shigeyama, S</creatorcontrib><creatorcontrib>Takai, H</creatorcontrib><creatorcontrib>Tsukahara, Y</creatorcontrib><creatorcontrib>Matsumoto, K</creatorcontrib><creatorcontrib>Suzuki, R</creatorcontrib><creatorcontrib>Yasuda, N</creatorcontrib><creatorcontrib>Okada, H</creatorcontrib><creatorcontrib>Suzuki, S</creatorcontrib><creatorcontrib>Foley, S J</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Radiation protection dosimetry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yagami, K</au><au>Miyoshi, T</au><au>Shigeyama, S</au><au>Takai, H</au><au>Tsukahara, Y</au><au>Matsumoto, K</au><au>Suzuki, R</au><au>Yasuda, N</au><au>Okada, H</au><au>Suzuki, S</au><au>Foley, S J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>EVALUATION OF PATIENT EXPOSURE IN FAST kVp SWITCHING DUAL ENERGY COMPUTED TOMOGRAPHY: PHANTOM STUDY</atitle><jtitle>Radiation protection dosimetry</jtitle><addtitle>Radiat Prot Dosimetry</addtitle><date>2018-10-01</date><risdate>2018</risdate><volume>181</volume><issue>3</issue><spage>261</spage><epage>268</epage><pages>261-268</pages><issn>0144-8420</issn><eissn>1742-3406</eissn><abstract>The aim of this study was to evaluate the suitability of size specific dose estimates (SSDE) to estimate patient dose in Fast kVp switching dual energy CT. An anthropomorphic phantom (RAN-110) was repeatedly scanned (chest, abdomen and the pelvis) using a 64 detector row MDCT (Discovery CT750 HD, GE Healthcare, Milwaukee, WI, USA) with various CT parameters, including Fast kVp switching. Dosimetry was performed using thermo-luminescent dosimeters, positioned both superficially and within the phantom. SSDE was calculated for all slices of the anthropomorphic phantom using both the localiser and axial images. In Fast kVp switching, SSDE underestimated the measured absorbed dose for the chest/abdomen region ~35% at the maximum, but were in closer agreement for the pelvic region about within 10%. In single energy techniques, SSDE could not be applied in the estimation of organ doses, but in Fast kVp switching dual energy techniques, SSDE could be applied for anatomical regions with larger thicknesses.</abstract><cop>England</cop><pmid>29462479</pmid><doi>10.1093/rpd/ncy022</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0144-8420
ispartof Radiation protection dosimetry, 2018-10, Vol.181 (3), p.261-268
issn 0144-8420
1742-3406
language eng
recordid cdi_proquest_miscellaneous_2007116872
source MEDLINE; Oxford University Press Journals All Titles (1996-Current); Alma/SFX Local Collection
subjects Abdomen - radiation effects
Humans
Pelvis - radiation effects
Phantoms, Imaging
Radiation Dosage
Radiation Monitoring
Radiography, Dual-Energy Scanned Projection - methods
Radiography, Thoracic
Tomography, X-Ray Computed - methods
title EVALUATION OF PATIENT EXPOSURE IN FAST kVp SWITCHING DUAL ENERGY COMPUTED TOMOGRAPHY: PHANTOM STUDY
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T01%3A47%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=EVALUATION%20OF%20PATIENT%20EXPOSURE%20IN%20FAST%20kVp%20SWITCHING%20DUAL%20ENERGY%20COMPUTED%20TOMOGRAPHY:%20PHANTOM%20STUDY&rft.jtitle=Radiation%20protection%20dosimetry&rft.au=Yagami,%20K&rft.date=2018-10-01&rft.volume=181&rft.issue=3&rft.spage=261&rft.epage=268&rft.pages=261-268&rft.issn=0144-8420&rft.eissn=1742-3406&rft_id=info:doi/10.1093/rpd/ncy022&rft_dat=%3Cproquest_cross%3E2007116872%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2007116872&rft_id=info:pmid/29462479&rfr_iscdi=true