Short Report: Source of bacterial shedding in laminar flow theatres
In a previous unpublished observation, unacceptably high bacterial counts, presumably due to shedding episodes, occurred in two of 56 (3.57%) slit-air samples during arthroplasty surgery in a laminar flow operating theatre. The isolates matched those cultured from swab samples taken from the skin of...
Gespeichert in:
Veröffentlicht in: | The Journal of hospital infection 2004-11, Vol.58 (3), p.230-232 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 232 |
---|---|
container_issue | 3 |
container_start_page | 230 |
container_title | The Journal of hospital infection |
container_volume | 58 |
creator | Owers, K L James, E Bannister, G C |
description | In a previous unpublished observation, unacceptably high bacterial counts, presumably due to shedding episodes, occurred in two of 56 (3.57%) slit-air samples during arthroplasty surgery in a laminar flow operating theatre. The isolates matched those cultured from swab samples taken from the skin of one of the surgeons's foreheads on each of the two occasions. These findings occurred despite scrub staff wearing standard occlusive gowns, hats and masks with visors. In order to localize the potential source of such shedding more accurately, 20 members of theatre staff underwent anonymous microbiological swabbing from the facial areas not covered by theatre clothing, namely their foreheads, eyebrows and ears. These swabs were cultured and the growths were compared statistically. Significantly more colonies were cultured from swabs taken from the theatre staff's ears (P=0.047, Freidman's test) compared with the other two facial areas studied. These data support the use of exhaust helmets in arthroplasty surgery, or at least mandatory coverage of the ears with theatre hats for scrub staff. |
doi_str_mv | 10.1016/j.jhin.2004.06.028 |
format | Article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_20041436</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>20041436</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_200414363</originalsourceid><addsrcrecordid>eNqNzjkOwjAQQFEXIBGWC1BNRYcZZ4PQIhA10COTTIgjxwbbEdcHJA5A9ZpffMbmArlAka9a3jbK8Bgx5ZhzjDcDFqEosmW-RjFiY-9bRCySIovY7txYF-BEjw9bONvelQS2hpssAzklNfiGqkqZOygDWnbKSAe1ti8IDcngyE_ZsJba0-znhC0O-8vuuHw4--zJh2unfElaS0O299fvmUiTPPk7fAMGv0LO</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>20041436</pqid></control><display><type>article</type><title>Short Report: Source of bacterial shedding in laminar flow theatres</title><source>Access via ScienceDirect (Elsevier)</source><creator>Owers, K L ; James, E ; Bannister, G C</creator><creatorcontrib>Owers, K L ; James, E ; Bannister, G C</creatorcontrib><description>In a previous unpublished observation, unacceptably high bacterial counts, presumably due to shedding episodes, occurred in two of 56 (3.57%) slit-air samples during arthroplasty surgery in a laminar flow operating theatre. The isolates matched those cultured from swab samples taken from the skin of one of the surgeons's foreheads on each of the two occasions. These findings occurred despite scrub staff wearing standard occlusive gowns, hats and masks with visors. In order to localize the potential source of such shedding more accurately, 20 members of theatre staff underwent anonymous microbiological swabbing from the facial areas not covered by theatre clothing, namely their foreheads, eyebrows and ears. These swabs were cultured and the growths were compared statistically. Significantly more colonies were cultured from swabs taken from the theatre staff's ears (P=0.047, Freidman's test) compared with the other two facial areas studied. These data support the use of exhaust helmets in arthroplasty surgery, or at least mandatory coverage of the ears with theatre hats for scrub staff.</description><identifier>ISSN: 0195-6701</identifier><identifier>DOI: 10.1016/j.jhin.2004.06.028</identifier><language>eng</language><subject>Bacteria</subject><ispartof>The Journal of hospital infection, 2004-11, Vol.58 (3), p.230-232</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Owers, K L</creatorcontrib><creatorcontrib>James, E</creatorcontrib><creatorcontrib>Bannister, G C</creatorcontrib><title>Short Report: Source of bacterial shedding in laminar flow theatres</title><title>The Journal of hospital infection</title><description>In a previous unpublished observation, unacceptably high bacterial counts, presumably due to shedding episodes, occurred in two of 56 (3.57%) slit-air samples during arthroplasty surgery in a laminar flow operating theatre. The isolates matched those cultured from swab samples taken from the skin of one of the surgeons's foreheads on each of the two occasions. These findings occurred despite scrub staff wearing standard occlusive gowns, hats and masks with visors. In order to localize the potential source of such shedding more accurately, 20 members of theatre staff underwent anonymous microbiological swabbing from the facial areas not covered by theatre clothing, namely their foreheads, eyebrows and ears. These swabs were cultured and the growths were compared statistically. Significantly more colonies were cultured from swabs taken from the theatre staff's ears (P=0.047, Freidman's test) compared with the other two facial areas studied. These data support the use of exhaust helmets in arthroplasty surgery, or at least mandatory coverage of the ears with theatre hats for scrub staff.</description><subject>Bacteria</subject><issn>0195-6701</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><recordid>eNqNzjkOwjAQQFEXIBGWC1BNRYcZZ4PQIhA10COTTIgjxwbbEdcHJA5A9ZpffMbmArlAka9a3jbK8Bgx5ZhzjDcDFqEosmW-RjFiY-9bRCySIovY7txYF-BEjw9bONvelQS2hpssAzklNfiGqkqZOygDWnbKSAe1ti8IDcngyE_ZsJba0-znhC0O-8vuuHw4--zJh2unfElaS0O299fvmUiTPPk7fAMGv0LO</recordid><startdate>20041101</startdate><enddate>20041101</enddate><creator>Owers, K L</creator><creator>James, E</creator><creator>Bannister, G C</creator><scope>7QL</scope><scope>7T7</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>P64</scope></search><sort><creationdate>20041101</creationdate><title>Short Report: Source of bacterial shedding in laminar flow theatres</title><author>Owers, K L ; James, E ; Bannister, G C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_200414363</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Bacteria</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Owers, K L</creatorcontrib><creatorcontrib>James, E</creatorcontrib><creatorcontrib>Bannister, G C</creatorcontrib><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>The Journal of hospital infection</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Owers, K L</au><au>James, E</au><au>Bannister, G C</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Short Report: Source of bacterial shedding in laminar flow theatres</atitle><jtitle>The Journal of hospital infection</jtitle><date>2004-11-01</date><risdate>2004</risdate><volume>58</volume><issue>3</issue><spage>230</spage><epage>232</epage><pages>230-232</pages><issn>0195-6701</issn><abstract>In a previous unpublished observation, unacceptably high bacterial counts, presumably due to shedding episodes, occurred in two of 56 (3.57%) slit-air samples during arthroplasty surgery in a laminar flow operating theatre. The isolates matched those cultured from swab samples taken from the skin of one of the surgeons's foreheads on each of the two occasions. These findings occurred despite scrub staff wearing standard occlusive gowns, hats and masks with visors. In order to localize the potential source of such shedding more accurately, 20 members of theatre staff underwent anonymous microbiological swabbing from the facial areas not covered by theatre clothing, namely their foreheads, eyebrows and ears. These swabs were cultured and the growths were compared statistically. Significantly more colonies were cultured from swabs taken from the theatre staff's ears (P=0.047, Freidman's test) compared with the other two facial areas studied. These data support the use of exhaust helmets in arthroplasty surgery, or at least mandatory coverage of the ears with theatre hats for scrub staff.</abstract><doi>10.1016/j.jhin.2004.06.028</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0195-6701 |
ispartof | The Journal of hospital infection, 2004-11, Vol.58 (3), p.230-232 |
issn | 0195-6701 |
language | eng |
recordid | cdi_proquest_miscellaneous_20041436 |
source | Access via ScienceDirect (Elsevier) |
subjects | Bacteria |
title | Short Report: Source of bacterial shedding in laminar flow theatres |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T11%3A11%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Short%20Report:%20Source%20of%20bacterial%20shedding%20in%20laminar%20flow%20theatres&rft.jtitle=The%20Journal%20of%20hospital%20infection&rft.au=Owers,%20K%20L&rft.date=2004-11-01&rft.volume=58&rft.issue=3&rft.spage=230&rft.epage=232&rft.pages=230-232&rft.issn=0195-6701&rft_id=info:doi/10.1016/j.jhin.2004.06.028&rft_dat=%3Cproquest%3E20041436%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=20041436&rft_id=info:pmid/&rfr_iscdi=true |