Selection criteria for oxidation method in total organic carbon measurement

During the measurement of total organic carbon (TOC), dissolved organic carbon is converted into CO2 by using high temperature combustion (HTC) or wet chemical oxidation (WCO). However, the criteria for selecting the oxidation methods are not clear. In this study, the chemical structures of organic...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chemosphere (Oxford) 2018-05, Vol.199, p.453-458
Hauptverfasser: Yoon, GeunSeok, Park, Sang-Min, Yang, Heuiwon, Tsang, Daniel C.W., Alessi, Daniel S., Baek, Kitae
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 458
container_issue
container_start_page 453
container_title Chemosphere (Oxford)
container_volume 199
creator Yoon, GeunSeok
Park, Sang-Min
Yang, Heuiwon
Tsang, Daniel C.W.
Alessi, Daniel S.
Baek, Kitae
description During the measurement of total organic carbon (TOC), dissolved organic carbon is converted into CO2 by using high temperature combustion (HTC) or wet chemical oxidation (WCO). However, the criteria for selecting the oxidation methods are not clear. In this study, the chemical structures of organic material were considered as a key factor to select the oxidation method used. Most non-degradable organic compounds showed a similar oxidation efficiency in both methods, including natural organic compounds, dyes, and pharmaceuticals, and thus both methods are appropriate to measure TOC in waters containing these compounds. However, only a fraction of the carbon in the halogenated compounds (perfluorooctanoic acid and trifluoroacetic acid) were oxidized using WCO, resulting in measured TOC values that are considerably lower than those determined by HTC. This result is likely due to the electronegativity of halogen elements which inhibits the approach of electron-rich sulfate radicals in the WCO, and the higher bond strength of carbon-halogen pairs as compared to carbon-hydrogen bonds, which results in a lower degree of oxidation of the compounds. Our results indicate that WCO could be used to oxidize most organic compounds, but may not be appropriate to quantify TOC in organic carbon pools that contain certain halogenated compounds. •Concentration of organic matter is not suitable to determine oxidation method.•Chemical structure is a key factor determining oxidation of organic matter.•Wet chemical oxidation oxidized partially halogenated compounds.
doi_str_mv 10.1016/j.chemosphere.2018.02.074
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2003045642</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0045653518302765</els_id><sourcerecordid>2003045642</sourcerecordid><originalsourceid>FETCH-LOGICAL-c377t-93bf5073835fed61747065e8dcab4d1912bd0f528184ced562ea89c82e8bd1f03</originalsourceid><addsrcrecordid>eNqNkE9PwzAMxSMEgjH4CqjcuLQ4adOmRzTxTyBxAM5RmrgsU9uMpEXw7QlsII6cLNnv2X4_Qk4pZBRoeb7K9BJ7F9ZL9JgxoCIDlkFV7JAZFVWdUlaLXTIDKHha8pwfkMMQVgDRzOt9csDqgudQsRm5e8QO9WjdkGhvR_RWJa3ziXu3Rn23exyXziR2SEY3qi5x_kUNVida-eZ7rMLkscdhPCJ7reoCHm_rnDxfXT4tbtL7h-vbxcV9qvOqGtM6b1oOVS5y3qIpaVVUUHIURqumMLSmrDHQciaoKDQaXjJUotaCoWgMbSGfk7PN3rV3rxOGUfY2aOw6NaCbgmQAeUxeFixK641UexeCx1auve2V_5AU5BdLuZJ_WMovlhKYjCyj92R7Zmp6NL_OH3hRsNgIMIZ9s-hl0BaH-LP1kak0zv7jzCdT84w-</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2003045642</pqid></control><display><type>article</type><title>Selection criteria for oxidation method in total organic carbon measurement</title><source>Access via ScienceDirect (Elsevier)</source><creator>Yoon, GeunSeok ; Park, Sang-Min ; Yang, Heuiwon ; Tsang, Daniel C.W. ; Alessi, Daniel S. ; Baek, Kitae</creator><creatorcontrib>Yoon, GeunSeok ; Park, Sang-Min ; Yang, Heuiwon ; Tsang, Daniel C.W. ; Alessi, Daniel S. ; Baek, Kitae</creatorcontrib><description>During the measurement of total organic carbon (TOC), dissolved organic carbon is converted into CO2 by using high temperature combustion (HTC) or wet chemical oxidation (WCO). However, the criteria for selecting the oxidation methods are not clear. In this study, the chemical structures of organic material were considered as a key factor to select the oxidation method used. Most non-degradable organic compounds showed a similar oxidation efficiency in both methods, including natural organic compounds, dyes, and pharmaceuticals, and thus both methods are appropriate to measure TOC in waters containing these compounds. However, only a fraction of the carbon in the halogenated compounds (perfluorooctanoic acid and trifluoroacetic acid) were oxidized using WCO, resulting in measured TOC values that are considerably lower than those determined by HTC. This result is likely due to the electronegativity of halogen elements which inhibits the approach of electron-rich sulfate radicals in the WCO, and the higher bond strength of carbon-halogen pairs as compared to carbon-hydrogen bonds, which results in a lower degree of oxidation of the compounds. Our results indicate that WCO could be used to oxidize most organic compounds, but may not be appropriate to quantify TOC in organic carbon pools that contain certain halogenated compounds. •Concentration of organic matter is not suitable to determine oxidation method.•Chemical structure is a key factor determining oxidation of organic matter.•Wet chemical oxidation oxidized partially halogenated compounds.</description><identifier>ISSN: 0045-6535</identifier><identifier>EISSN: 1879-1298</identifier><identifier>DOI: 10.1016/j.chemosphere.2018.02.074</identifier><identifier>PMID: 29453072</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Carbon dioxide ; Combustion ; Organic matter ; Total organic carbon ; Wet chemical oxidation</subject><ispartof>Chemosphere (Oxford), 2018-05, Vol.199, p.453-458</ispartof><rights>2018 Elsevier Ltd</rights><rights>Copyright © 2018 Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c377t-93bf5073835fed61747065e8dcab4d1912bd0f528184ced562ea89c82e8bd1f03</citedby><cites>FETCH-LOGICAL-c377t-93bf5073835fed61747065e8dcab4d1912bd0f528184ced562ea89c82e8bd1f03</cites><orcidid>0000-0002-7976-6484 ; 0000-0002-6850-733X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.chemosphere.2018.02.074$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29453072$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Yoon, GeunSeok</creatorcontrib><creatorcontrib>Park, Sang-Min</creatorcontrib><creatorcontrib>Yang, Heuiwon</creatorcontrib><creatorcontrib>Tsang, Daniel C.W.</creatorcontrib><creatorcontrib>Alessi, Daniel S.</creatorcontrib><creatorcontrib>Baek, Kitae</creatorcontrib><title>Selection criteria for oxidation method in total organic carbon measurement</title><title>Chemosphere (Oxford)</title><addtitle>Chemosphere</addtitle><description>During the measurement of total organic carbon (TOC), dissolved organic carbon is converted into CO2 by using high temperature combustion (HTC) or wet chemical oxidation (WCO). However, the criteria for selecting the oxidation methods are not clear. In this study, the chemical structures of organic material were considered as a key factor to select the oxidation method used. Most non-degradable organic compounds showed a similar oxidation efficiency in both methods, including natural organic compounds, dyes, and pharmaceuticals, and thus both methods are appropriate to measure TOC in waters containing these compounds. However, only a fraction of the carbon in the halogenated compounds (perfluorooctanoic acid and trifluoroacetic acid) were oxidized using WCO, resulting in measured TOC values that are considerably lower than those determined by HTC. This result is likely due to the electronegativity of halogen elements which inhibits the approach of electron-rich sulfate radicals in the WCO, and the higher bond strength of carbon-halogen pairs as compared to carbon-hydrogen bonds, which results in a lower degree of oxidation of the compounds. Our results indicate that WCO could be used to oxidize most organic compounds, but may not be appropriate to quantify TOC in organic carbon pools that contain certain halogenated compounds. •Concentration of organic matter is not suitable to determine oxidation method.•Chemical structure is a key factor determining oxidation of organic matter.•Wet chemical oxidation oxidized partially halogenated compounds.</description><subject>Carbon dioxide</subject><subject>Combustion</subject><subject>Organic matter</subject><subject>Total organic carbon</subject><subject>Wet chemical oxidation</subject><issn>0045-6535</issn><issn>1879-1298</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqNkE9PwzAMxSMEgjH4CqjcuLQ4adOmRzTxTyBxAM5RmrgsU9uMpEXw7QlsII6cLNnv2X4_Qk4pZBRoeb7K9BJ7F9ZL9JgxoCIDlkFV7JAZFVWdUlaLXTIDKHha8pwfkMMQVgDRzOt9csDqgudQsRm5e8QO9WjdkGhvR_RWJa3ziXu3Rn23exyXziR2SEY3qi5x_kUNVida-eZ7rMLkscdhPCJ7reoCHm_rnDxfXT4tbtL7h-vbxcV9qvOqGtM6b1oOVS5y3qIpaVVUUHIURqumMLSmrDHQciaoKDQaXjJUotaCoWgMbSGfk7PN3rV3rxOGUfY2aOw6NaCbgmQAeUxeFixK641UexeCx1auve2V_5AU5BdLuZJ_WMovlhKYjCyj92R7Zmp6NL_OH3hRsNgIMIZ9s-hl0BaH-LP1kak0zv7jzCdT84w-</recordid><startdate>20180501</startdate><enddate>20180501</enddate><creator>Yoon, GeunSeok</creator><creator>Park, Sang-Min</creator><creator>Yang, Heuiwon</creator><creator>Tsang, Daniel C.W.</creator><creator>Alessi, Daniel S.</creator><creator>Baek, Kitae</creator><general>Elsevier Ltd</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-7976-6484</orcidid><orcidid>https://orcid.org/0000-0002-6850-733X</orcidid></search><sort><creationdate>20180501</creationdate><title>Selection criteria for oxidation method in total organic carbon measurement</title><author>Yoon, GeunSeok ; Park, Sang-Min ; Yang, Heuiwon ; Tsang, Daniel C.W. ; Alessi, Daniel S. ; Baek, Kitae</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c377t-93bf5073835fed61747065e8dcab4d1912bd0f528184ced562ea89c82e8bd1f03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Carbon dioxide</topic><topic>Combustion</topic><topic>Organic matter</topic><topic>Total organic carbon</topic><topic>Wet chemical oxidation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yoon, GeunSeok</creatorcontrib><creatorcontrib>Park, Sang-Min</creatorcontrib><creatorcontrib>Yang, Heuiwon</creatorcontrib><creatorcontrib>Tsang, Daniel C.W.</creatorcontrib><creatorcontrib>Alessi, Daniel S.</creatorcontrib><creatorcontrib>Baek, Kitae</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Chemosphere (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yoon, GeunSeok</au><au>Park, Sang-Min</au><au>Yang, Heuiwon</au><au>Tsang, Daniel C.W.</au><au>Alessi, Daniel S.</au><au>Baek, Kitae</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Selection criteria for oxidation method in total organic carbon measurement</atitle><jtitle>Chemosphere (Oxford)</jtitle><addtitle>Chemosphere</addtitle><date>2018-05-01</date><risdate>2018</risdate><volume>199</volume><spage>453</spage><epage>458</epage><pages>453-458</pages><issn>0045-6535</issn><eissn>1879-1298</eissn><abstract>During the measurement of total organic carbon (TOC), dissolved organic carbon is converted into CO2 by using high temperature combustion (HTC) or wet chemical oxidation (WCO). However, the criteria for selecting the oxidation methods are not clear. In this study, the chemical structures of organic material were considered as a key factor to select the oxidation method used. Most non-degradable organic compounds showed a similar oxidation efficiency in both methods, including natural organic compounds, dyes, and pharmaceuticals, and thus both methods are appropriate to measure TOC in waters containing these compounds. However, only a fraction of the carbon in the halogenated compounds (perfluorooctanoic acid and trifluoroacetic acid) were oxidized using WCO, resulting in measured TOC values that are considerably lower than those determined by HTC. This result is likely due to the electronegativity of halogen elements which inhibits the approach of electron-rich sulfate radicals in the WCO, and the higher bond strength of carbon-halogen pairs as compared to carbon-hydrogen bonds, which results in a lower degree of oxidation of the compounds. Our results indicate that WCO could be used to oxidize most organic compounds, but may not be appropriate to quantify TOC in organic carbon pools that contain certain halogenated compounds. •Concentration of organic matter is not suitable to determine oxidation method.•Chemical structure is a key factor determining oxidation of organic matter.•Wet chemical oxidation oxidized partially halogenated compounds.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>29453072</pmid><doi>10.1016/j.chemosphere.2018.02.074</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0002-7976-6484</orcidid><orcidid>https://orcid.org/0000-0002-6850-733X</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0045-6535
ispartof Chemosphere (Oxford), 2018-05, Vol.199, p.453-458
issn 0045-6535
1879-1298
language eng
recordid cdi_proquest_miscellaneous_2003045642
source Access via ScienceDirect (Elsevier)
subjects Carbon dioxide
Combustion
Organic matter
Total organic carbon
Wet chemical oxidation
title Selection criteria for oxidation method in total organic carbon measurement
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T01%3A13%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Selection%20criteria%20for%20oxidation%20method%20in%20total%20organic%20carbon%20measurement&rft.jtitle=Chemosphere%20(Oxford)&rft.au=Yoon,%20GeunSeok&rft.date=2018-05-01&rft.volume=199&rft.spage=453&rft.epage=458&rft.pages=453-458&rft.issn=0045-6535&rft.eissn=1879-1298&rft_id=info:doi/10.1016/j.chemosphere.2018.02.074&rft_dat=%3Cproquest_cross%3E2003045642%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2003045642&rft_id=info:pmid/29453072&rft_els_id=S0045653518302765&rfr_iscdi=true