Application of a Fast Separation Method for Anti-diabetics in Pharmaceuticals Using Monolithic Column: Comparative Study With Silica Based C-18 Particle Packed Column

Abstract Run time is a predominant factor in HPLC for quality control laboratories especially if there is large number of samples have to be analyzed. Working at high flow rates cannot be attained with silica based particle packed column due to elevated backpressure issues. The use of monolithic col...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of chromatographic science 2018-04, Vol.56 (4), p.351-357
Hauptverfasser: Hemdan, A, Abdel-Aziz, Omar
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 357
container_issue 4
container_start_page 351
container_title Journal of chromatographic science
container_volume 56
creator Hemdan, A
Abdel-Aziz, Omar
description Abstract Run time is a predominant factor in HPLC for quality control laboratories especially if there is large number of samples have to be analyzed. Working at high flow rates cannot be attained with silica based particle packed column due to elevated backpressure issues. The use of monolithic column as an alternative to traditional C-18 column was tested for fast separation of pharmaceuticals, where the results were very competitive. The performance comparison of both columns was tested for separation of anti-diabetic combination containing Metformin, Pioglitazone and Glimepiride using Gliclazide as an internal standard. Working at high flow rates with less significant backpressure was obtained with the monolithic column where the run time was reduced from 6 min in traditional column to only 1 min in monolithic column with accepted resolution. The structure of the monolith contains many pores which can adapt the high flow rate of the mobile phase. Moreover, peak symmetry and equilibration time were more efficient with monolithic column.
doi_str_mv 10.1093/chromsci/bmy009
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2001061735</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><oup_id>10.1093/chromsci/bmy009</oup_id><sourcerecordid>2001061735</sourcerecordid><originalsourceid>FETCH-LOGICAL-c373t-264c0f4517b5dfe3c0652eb5be2f85cb7ed49a39a76677122dcc53f6e1552cc63</originalsourceid><addsrcrecordid>eNqFkU1v1DAQhq0KRJeWc29ojggprD9iZ8Ntu6ItUisqbSu4RY4zYd0mcWo7SPuH-J14ScuV03hePfP48BJyxugnRkuxNDvv-mDssu73lJZHZMHKXGZclD9ekQWlnGWlUvKYvA3h4bCylXxDjnmZc8kVX5Df63HsrNHRugFcCxoudIiwxVH7ObzBuHMNtM7Deog2a6yuMVoTwA5wu9O-1wanFOguwH2ww0-4cYPrbNxZAxvXTf3wOc1-Nv5C2Map2cP3BMDWHj6Hcx2wgU3GVnCrfXJ1mB7m8RD-FZyS123y47vneULuL77cba6y62-XXzfr68yIQsSMq9zQNpesqGXTojBUSY61rJG3K2nqApu81KLUhVJFwThvjJGiVcik5MYocUI-zN7Ru6cJQ6x6Gwx2nR7QTaHilDKqWCFkQpczarwLwWNbjd722u8rRqtDOdVLOdVcTrp4_yyf6h6bf_xLGwn4OANuGv9r-wO6455_</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2001061735</pqid></control><display><type>article</type><title>Application of a Fast Separation Method for Anti-diabetics in Pharmaceuticals Using Monolithic Column: Comparative Study With Silica Based C-18 Particle Packed Column</title><source>Oxford University Press Journals All Titles (1996-Current)</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><source>Free Full-Text Journals in Chemistry</source><creator>Hemdan, A ; Abdel-Aziz, Omar</creator><creatorcontrib>Hemdan, A ; Abdel-Aziz, Omar</creatorcontrib><description>Abstract Run time is a predominant factor in HPLC for quality control laboratories especially if there is large number of samples have to be analyzed. Working at high flow rates cannot be attained with silica based particle packed column due to elevated backpressure issues. The use of monolithic column as an alternative to traditional C-18 column was tested for fast separation of pharmaceuticals, where the results were very competitive. The performance comparison of both columns was tested for separation of anti-diabetic combination containing Metformin, Pioglitazone and Glimepiride using Gliclazide as an internal standard. Working at high flow rates with less significant backpressure was obtained with the monolithic column where the run time was reduced from 6 min in traditional column to only 1 min in monolithic column with accepted resolution. The structure of the monolith contains many pores which can adapt the high flow rate of the mobile phase. Moreover, peak symmetry and equilibration time were more efficient with monolithic column.</description><identifier>ISSN: 0021-9665</identifier><identifier>EISSN: 1945-239X</identifier><identifier>DOI: 10.1093/chromsci/bmy009</identifier><identifier>PMID: 29425262</identifier><language>eng</language><publisher>United States: Oxford University Press</publisher><ispartof>Journal of chromatographic science, 2018-04, Vol.56 (4), p.351-357</ispartof><rights>The Author(s) 2018. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com 2018</rights><rights>The Author(s) 2018. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c373t-264c0f4517b5dfe3c0652eb5be2f85cb7ed49a39a76677122dcc53f6e1552cc63</citedby><cites>FETCH-LOGICAL-c373t-264c0f4517b5dfe3c0652eb5be2f85cb7ed49a39a76677122dcc53f6e1552cc63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,1578,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29425262$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hemdan, A</creatorcontrib><creatorcontrib>Abdel-Aziz, Omar</creatorcontrib><title>Application of a Fast Separation Method for Anti-diabetics in Pharmaceuticals Using Monolithic Column: Comparative Study With Silica Based C-18 Particle Packed Column</title><title>Journal of chromatographic science</title><addtitle>J Chromatogr Sci</addtitle><description>Abstract Run time is a predominant factor in HPLC for quality control laboratories especially if there is large number of samples have to be analyzed. Working at high flow rates cannot be attained with silica based particle packed column due to elevated backpressure issues. The use of monolithic column as an alternative to traditional C-18 column was tested for fast separation of pharmaceuticals, where the results were very competitive. The performance comparison of both columns was tested for separation of anti-diabetic combination containing Metformin, Pioglitazone and Glimepiride using Gliclazide as an internal standard. Working at high flow rates with less significant backpressure was obtained with the monolithic column where the run time was reduced from 6 min in traditional column to only 1 min in monolithic column with accepted resolution. The structure of the monolith contains many pores which can adapt the high flow rate of the mobile phase. Moreover, peak symmetry and equilibration time were more efficient with monolithic column.</description><issn>0021-9665</issn><issn>1945-239X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqFkU1v1DAQhq0KRJeWc29ojggprD9iZ8Ntu6ItUisqbSu4RY4zYd0mcWo7SPuH-J14ScuV03hePfP48BJyxugnRkuxNDvv-mDssu73lJZHZMHKXGZclD9ekQWlnGWlUvKYvA3h4bCylXxDjnmZc8kVX5Df63HsrNHRugFcCxoudIiwxVH7ObzBuHMNtM7Deog2a6yuMVoTwA5wu9O-1wanFOguwH2ww0-4cYPrbNxZAxvXTf3wOc1-Nv5C2Map2cP3BMDWHj6Hcx2wgU3GVnCrfXJ1mB7m8RD-FZyS123y47vneULuL77cba6y62-XXzfr68yIQsSMq9zQNpesqGXTojBUSY61rJG3K2nqApu81KLUhVJFwThvjJGiVcik5MYocUI-zN7Ru6cJQ6x6Gwx2nR7QTaHilDKqWCFkQpczarwLwWNbjd722u8rRqtDOdVLOdVcTrp4_yyf6h6bf_xLGwn4OANuGv9r-wO6455_</recordid><startdate>20180401</startdate><enddate>20180401</enddate><creator>Hemdan, A</creator><creator>Abdel-Aziz, Omar</creator><general>Oxford University Press</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20180401</creationdate><title>Application of a Fast Separation Method for Anti-diabetics in Pharmaceuticals Using Monolithic Column: Comparative Study With Silica Based C-18 Particle Packed Column</title><author>Hemdan, A ; Abdel-Aziz, Omar</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c373t-264c0f4517b5dfe3c0652eb5be2f85cb7ed49a39a76677122dcc53f6e1552cc63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hemdan, A</creatorcontrib><creatorcontrib>Abdel-Aziz, Omar</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of chromatographic science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hemdan, A</au><au>Abdel-Aziz, Omar</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Application of a Fast Separation Method for Anti-diabetics in Pharmaceuticals Using Monolithic Column: Comparative Study With Silica Based C-18 Particle Packed Column</atitle><jtitle>Journal of chromatographic science</jtitle><addtitle>J Chromatogr Sci</addtitle><date>2018-04-01</date><risdate>2018</risdate><volume>56</volume><issue>4</issue><spage>351</spage><epage>357</epage><pages>351-357</pages><issn>0021-9665</issn><eissn>1945-239X</eissn><abstract>Abstract Run time is a predominant factor in HPLC for quality control laboratories especially if there is large number of samples have to be analyzed. Working at high flow rates cannot be attained with silica based particle packed column due to elevated backpressure issues. The use of monolithic column as an alternative to traditional C-18 column was tested for fast separation of pharmaceuticals, where the results were very competitive. The performance comparison of both columns was tested for separation of anti-diabetic combination containing Metformin, Pioglitazone and Glimepiride using Gliclazide as an internal standard. Working at high flow rates with less significant backpressure was obtained with the monolithic column where the run time was reduced from 6 min in traditional column to only 1 min in monolithic column with accepted resolution. The structure of the monolith contains many pores which can adapt the high flow rate of the mobile phase. Moreover, peak symmetry and equilibration time were more efficient with monolithic column.</abstract><cop>United States</cop><pub>Oxford University Press</pub><pmid>29425262</pmid><doi>10.1093/chromsci/bmy009</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0021-9665
ispartof Journal of chromatographic science, 2018-04, Vol.56 (4), p.351-357
issn 0021-9665
1945-239X
language eng
recordid cdi_proquest_miscellaneous_2001061735
source Oxford University Press Journals All Titles (1996-Current); Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection; Free Full-Text Journals in Chemistry
title Application of a Fast Separation Method for Anti-diabetics in Pharmaceuticals Using Monolithic Column: Comparative Study With Silica Based C-18 Particle Packed Column
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T22%3A56%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Application%20of%20a%20Fast%20Separation%20Method%20for%20Anti-diabetics%20in%20Pharmaceuticals%20Using%20Monolithic%20Column:%20Comparative%20Study%20With%20Silica%20Based%20C-18%20Particle%20Packed%20Column&rft.jtitle=Journal%20of%20chromatographic%20science&rft.au=Hemdan,%20A&rft.date=2018-04-01&rft.volume=56&rft.issue=4&rft.spage=351&rft.epage=357&rft.pages=351-357&rft.issn=0021-9665&rft.eissn=1945-239X&rft_id=info:doi/10.1093/chromsci/bmy009&rft_dat=%3Cproquest_cross%3E2001061735%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2001061735&rft_id=info:pmid/29425262&rft_oup_id=10.1093/chromsci/bmy009&rfr_iscdi=true