Heparin molecularly imprinted polymer thin flm on gold electrode by plasma-induced graft polymerization for label-free biosensor
[Display omitted] •A label-free quartz crystal microbalance biosensor for heparin detection based on a macro-molecularly imprinted polymer (MIP) as an artificial recognition element is addressed.•The novel strategy for MIP in the form of thin film on a gold electrode with the plasma-induced graft po...
Gespeichert in:
Veröffentlicht in: | Journal of pharmaceutical and biomedical analysis 2018-03, Vol.151, p.324-330 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | [Display omitted]
•A label-free quartz crystal microbalance biosensor for heparin detection based on a macro-molecularly imprinted polymer (MIP) as an artificial recognition element is addressed.•The novel strategy for MIP in the form of thin film on a gold electrode with the plasma-induced graft polymerization (PIP) technique is demonstrated.•The heparin-PIP-MIP as a synthetic antibody specifically binds to heparin and can be applied to biosensor.
Heparin, a highly sulfated glycosaminoglycan, is an important biomaterial having biological and therapeutic functionalities such as anticoagulation, regeneration, and protein stabilization. This study addresses a label-free quartz crystal microbalance (QCM) biosensor for heparin detection based on a macromolecularly imprinted polymer (MIP) as an artificial recognition element. We demonstrate the novel strategy for MIP in the form of thin film on a gold (Au) electrode with the plasma-induced graft polymerization (PIP) technique. The procedure of PIP is as follows: (i) Hexamethyldisiloxane plasma-polymerized thin film (PPF) as a pre-coating scaffold of active species for PIP (post-polymerization) is deposited on an Au electrode. (ii) The PPF/Au electrode is soaked in an water solution containing heparin (template), (2-(methacryloxy)-ethyl)trimethylammonium chloride acrylamide (functional monomer), acrylamide, and N,N-methylenebisacrylamide (crosslinker). Double bonds of monomer and crosslinker attacked by residually active species in pre-coating PPF cause radical chain reaction. Consequently, a growing polymer network of 20 nm thickness of PIP-MIP thin film is formed and grafted on the PPF/Au surface. (iii) The PIP-MIP/PPF/Au is washed by sodium chloride solution so as to remove the template. Non-imprinted polymer (NIP) is carried out like the same procedure without a template. The AFM, XPS, and QCM measurements show that the PIP process facilitates macromolecularly surface imprinting of template heparin where the template is easily removed and is rapidly rebound to PIP-MIP without a diffusional barrier. The heparin-PIP-MIP specifically binds to heparin compared with heparin analog chondroitin sulfate C (selective factor: 4.0) and a detectable range of heparin in the presence of CS (0.1 wt%) was 0.001-0.1 wt%. The PIP-NIP does not show selectivity between them. The evaluated binding kinetics are association (ka = 350 ± 100 M−1 s−1), dissociation (kd = (5.0 ± 2.0) × 10−4 s−1), and binding (KD = 1.3 ± 0.6 μM) consta |
---|---|
ISSN: | 0731-7085 1873-264X |