Effectiveness of a cap-assisted device in the endoscopic removal of food bolus obstruction from the esophagus

The use of a transparent cap has been found to be effective for retrieval of an esophageal foreign body. However, data on the use of a cap in food bolus obstruction (FBO) are limited. This study aims to assess the effectiveness of a cap-assisted technique compared with conventional techniques in rem...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Gastrointestinal endoscopy 2018-05, Vol.87 (5), p.1198-1203
Hauptverfasser: Ooi, Marie, Young, Edward John, Nguyen, Nam Q.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1203
container_issue 5
container_start_page 1198
container_title Gastrointestinal endoscopy
container_volume 87
creator Ooi, Marie
Young, Edward John
Nguyen, Nam Q.
description The use of a transparent cap has been found to be effective for retrieval of an esophageal foreign body. However, data on the use of a cap in food bolus obstruction (FBO) are limited. This study aims to assess the effectiveness of a cap-assisted technique compared with conventional techniques in removal of FBO. All patients who underwent an endoscopy for boneless FBO between 2011 and 2016 were prospectively recruited. The measured outcomes were procedure time, success rate of food bolus (FB) extraction, rate of en bloc removal, procedure-related adverse events, and length of hospital stay (LOS) between the 2 groups. Of the 315 patients who had an endoscopy for FBO, 48 (15.2%) had spontaneous passage of FB and 267 (84.8%) had impacted FB. Sixty-eight (25%) patients had the “push” maneuver, and 199 (75%) patients had the “pull” maneuver to remove FB. Of those who had the “pull” maneuver, a cap was used for 93 and conventional device(s) for 106. The use of a cap was associated with a shorter procedural time (34.3 ± 8.0 minutes versus 43.3 ± 22.6 minutes, P = .003), a higher rate of en bloc removal (87.3% versus 22.8%, P < .001), a lower rate of adverse events (0/93 versus 7/106, P = .01), and a shorter LOS (1.0 ± 0.6 days versus 1.6 ± 1.4 days, P = .0017). The cap-assisted technique has been found to be effective and safe in removal of esophageal FBO. This technique was associated with a shorter procedural time and a reduced LOS compared with conventional techniques. However, these findings require further validation in a randomized control study.
doi_str_mv 10.1016/j.gie.2017.12.022
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1989553865</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0016510718300087</els_id><sourcerecordid>1989553865</sourcerecordid><originalsourceid>FETCH-LOGICAL-c353t-413713e9dff491401b27b4eb8c92424b785206a974190dc5be65da71dd2da3bc3</originalsourceid><addsrcrecordid>eNp9kM1u1DAURi0EotPCA7BBXrJJ8LWTOBYrVBWKVIkNrC3_XLceJXGwk5F4ezyawpLV3ZzvSPcQ8g5YCwyGj8f2MWLLGcgWeMs4f0EOwJRsBinVS3JgFWp6YPKKXJdyZIyNXMBrcsWVqNjID2S-CwHdFk-4YCk0BWqoM2tjSollQ089nqJDGhe6PSHFxafi0hodzTink5nOk5CSpzZNexXYsuW9CtNCQ07zZVXS-mQe9_KGvApmKvj2-d6Qn1_uftzeNw_fv367_fzQONGLrelASBCofAidgo6B5dJ2aEeneMc7K8ees8Eo2YFi3vUWh94bCd5zb4R14oZ8uHjXnH7tWDY9x-JwmsyCaS8a1Kj6XoxDX1G4oC6nUjIGveY4m_xbA9Pnyvqoa2V9rqyB61q5bt4_63c7o_-3-Ju1Ap8uANYnTxGzLi7i4tDHXGtrn-J_9H8Aqs2OLw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1989553865</pqid></control><display><type>article</type><title>Effectiveness of a cap-assisted device in the endoscopic removal of food bolus obstruction from the esophagus</title><source>Elsevier ScienceDirect Journals</source><creator>Ooi, Marie ; Young, Edward John ; Nguyen, Nam Q.</creator><creatorcontrib>Ooi, Marie ; Young, Edward John ; Nguyen, Nam Q.</creatorcontrib><description>The use of a transparent cap has been found to be effective for retrieval of an esophageal foreign body. However, data on the use of a cap in food bolus obstruction (FBO) are limited. This study aims to assess the effectiveness of a cap-assisted technique compared with conventional techniques in removal of FBO. All patients who underwent an endoscopy for boneless FBO between 2011 and 2016 were prospectively recruited. The measured outcomes were procedure time, success rate of food bolus (FB) extraction, rate of en bloc removal, procedure-related adverse events, and length of hospital stay (LOS) between the 2 groups. Of the 315 patients who had an endoscopy for FBO, 48 (15.2%) had spontaneous passage of FB and 267 (84.8%) had impacted FB. Sixty-eight (25%) patients had the “push” maneuver, and 199 (75%) patients had the “pull” maneuver to remove FB. Of those who had the “pull” maneuver, a cap was used for 93 and conventional device(s) for 106. The use of a cap was associated with a shorter procedural time (34.3 ± 8.0 minutes versus 43.3 ± 22.6 minutes, P = .003), a higher rate of en bloc removal (87.3% versus 22.8%, P &lt; .001), a lower rate of adverse events (0/93 versus 7/106, P = .01), and a shorter LOS (1.0 ± 0.6 days versus 1.6 ± 1.4 days, P = .0017). The cap-assisted technique has been found to be effective and safe in removal of esophageal FBO. This technique was associated with a shorter procedural time and a reduced LOS compared with conventional techniques. However, these findings require further validation in a randomized control study.</description><identifier>ISSN: 0016-5107</identifier><identifier>EISSN: 1097-6779</identifier><identifier>DOI: 10.1016/j.gie.2017.12.022</identifier><identifier>PMID: 29309782</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><ispartof>Gastrointestinal endoscopy, 2018-05, Vol.87 (5), p.1198-1203</ispartof><rights>2018 American Society for Gastrointestinal Endoscopy</rights><rights>Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c353t-413713e9dff491401b27b4eb8c92424b785206a974190dc5be65da71dd2da3bc3</citedby><cites>FETCH-LOGICAL-c353t-413713e9dff491401b27b4eb8c92424b785206a974190dc5be65da71dd2da3bc3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0016510718300087$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65534</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29309782$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ooi, Marie</creatorcontrib><creatorcontrib>Young, Edward John</creatorcontrib><creatorcontrib>Nguyen, Nam Q.</creatorcontrib><title>Effectiveness of a cap-assisted device in the endoscopic removal of food bolus obstruction from the esophagus</title><title>Gastrointestinal endoscopy</title><addtitle>Gastrointest Endosc</addtitle><description>The use of a transparent cap has been found to be effective for retrieval of an esophageal foreign body. However, data on the use of a cap in food bolus obstruction (FBO) are limited. This study aims to assess the effectiveness of a cap-assisted technique compared with conventional techniques in removal of FBO. All patients who underwent an endoscopy for boneless FBO between 2011 and 2016 were prospectively recruited. The measured outcomes were procedure time, success rate of food bolus (FB) extraction, rate of en bloc removal, procedure-related adverse events, and length of hospital stay (LOS) between the 2 groups. Of the 315 patients who had an endoscopy for FBO, 48 (15.2%) had spontaneous passage of FB and 267 (84.8%) had impacted FB. Sixty-eight (25%) patients had the “push” maneuver, and 199 (75%) patients had the “pull” maneuver to remove FB. Of those who had the “pull” maneuver, a cap was used for 93 and conventional device(s) for 106. The use of a cap was associated with a shorter procedural time (34.3 ± 8.0 minutes versus 43.3 ± 22.6 minutes, P = .003), a higher rate of en bloc removal (87.3% versus 22.8%, P &lt; .001), a lower rate of adverse events (0/93 versus 7/106, P = .01), and a shorter LOS (1.0 ± 0.6 days versus 1.6 ± 1.4 days, P = .0017). The cap-assisted technique has been found to be effective and safe in removal of esophageal FBO. This technique was associated with a shorter procedural time and a reduced LOS compared with conventional techniques. However, these findings require further validation in a randomized control study.</description><issn>0016-5107</issn><issn>1097-6779</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp9kM1u1DAURi0EotPCA7BBXrJJ8LWTOBYrVBWKVIkNrC3_XLceJXGwk5F4ezyawpLV3ZzvSPcQ8g5YCwyGj8f2MWLLGcgWeMs4f0EOwJRsBinVS3JgFWp6YPKKXJdyZIyNXMBrcsWVqNjID2S-CwHdFk-4YCk0BWqoM2tjSollQ089nqJDGhe6PSHFxafi0hodzTink5nOk5CSpzZNexXYsuW9CtNCQ07zZVXS-mQe9_KGvApmKvj2-d6Qn1_uftzeNw_fv367_fzQONGLrelASBCofAidgo6B5dJ2aEeneMc7K8ees8Eo2YFi3vUWh94bCd5zb4R14oZ8uHjXnH7tWDY9x-JwmsyCaS8a1Kj6XoxDX1G4oC6nUjIGveY4m_xbA9Pnyvqoa2V9rqyB61q5bt4_63c7o_-3-Ju1Ap8uANYnTxGzLi7i4tDHXGtrn-J_9H8Aqs2OLw</recordid><startdate>20180501</startdate><enddate>20180501</enddate><creator>Ooi, Marie</creator><creator>Young, Edward John</creator><creator>Nguyen, Nam Q.</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20180501</creationdate><title>Effectiveness of a cap-assisted device in the endoscopic removal of food bolus obstruction from the esophagus</title><author>Ooi, Marie ; Young, Edward John ; Nguyen, Nam Q.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c353t-413713e9dff491401b27b4eb8c92424b785206a974190dc5be65da71dd2da3bc3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ooi, Marie</creatorcontrib><creatorcontrib>Young, Edward John</creatorcontrib><creatorcontrib>Nguyen, Nam Q.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Gastrointestinal endoscopy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ooi, Marie</au><au>Young, Edward John</au><au>Nguyen, Nam Q.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effectiveness of a cap-assisted device in the endoscopic removal of food bolus obstruction from the esophagus</atitle><jtitle>Gastrointestinal endoscopy</jtitle><addtitle>Gastrointest Endosc</addtitle><date>2018-05-01</date><risdate>2018</risdate><volume>87</volume><issue>5</issue><spage>1198</spage><epage>1203</epage><pages>1198-1203</pages><issn>0016-5107</issn><eissn>1097-6779</eissn><abstract>The use of a transparent cap has been found to be effective for retrieval of an esophageal foreign body. However, data on the use of a cap in food bolus obstruction (FBO) are limited. This study aims to assess the effectiveness of a cap-assisted technique compared with conventional techniques in removal of FBO. All patients who underwent an endoscopy for boneless FBO between 2011 and 2016 were prospectively recruited. The measured outcomes were procedure time, success rate of food bolus (FB) extraction, rate of en bloc removal, procedure-related adverse events, and length of hospital stay (LOS) between the 2 groups. Of the 315 patients who had an endoscopy for FBO, 48 (15.2%) had spontaneous passage of FB and 267 (84.8%) had impacted FB. Sixty-eight (25%) patients had the “push” maneuver, and 199 (75%) patients had the “pull” maneuver to remove FB. Of those who had the “pull” maneuver, a cap was used for 93 and conventional device(s) for 106. The use of a cap was associated with a shorter procedural time (34.3 ± 8.0 minutes versus 43.3 ± 22.6 minutes, P = .003), a higher rate of en bloc removal (87.3% versus 22.8%, P &lt; .001), a lower rate of adverse events (0/93 versus 7/106, P = .01), and a shorter LOS (1.0 ± 0.6 days versus 1.6 ± 1.4 days, P = .0017). The cap-assisted technique has been found to be effective and safe in removal of esophageal FBO. This technique was associated with a shorter procedural time and a reduced LOS compared with conventional techniques. However, these findings require further validation in a randomized control study.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>29309782</pmid><doi>10.1016/j.gie.2017.12.022</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0016-5107
ispartof Gastrointestinal endoscopy, 2018-05, Vol.87 (5), p.1198-1203
issn 0016-5107
1097-6779
language eng
recordid cdi_proquest_miscellaneous_1989553865
source Elsevier ScienceDirect Journals
title Effectiveness of a cap-assisted device in the endoscopic removal of food bolus obstruction from the esophagus
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-16T00%3A38%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effectiveness%20of%20a%20cap-assisted%20device%20in%20the%20endoscopic%20removal%20of%20food%20bolus%20obstruction%20from%20the%20esophagus&rft.jtitle=Gastrointestinal%20endoscopy&rft.au=Ooi,%20Marie&rft.date=2018-05-01&rft.volume=87&rft.issue=5&rft.spage=1198&rft.epage=1203&rft.pages=1198-1203&rft.issn=0016-5107&rft.eissn=1097-6779&rft_id=info:doi/10.1016/j.gie.2017.12.022&rft_dat=%3Cproquest_cross%3E1989553865%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1989553865&rft_id=info:pmid/29309782&rft_els_id=S0016510718300087&rfr_iscdi=true