Glassy carbon electrode modified with carbon black for sensitive estradiol determination by means of voltammetry and flow injection analysis with amperometric detection
A voltammetric method for fast and sensitive estradiol determination using carbon black modified glassy carbon electrode (CBGC) is proposed. The use of carbon black as a modifying layer led to obtain low detection limit (9.2·10−8 mol L−1 for a preconcentration time of 60 s) and stability of register...
Gespeichert in:
Veröffentlicht in: | Analytical biochemistry 2018-03, Vol.544, p.7-12 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 12 |
---|---|
container_issue | |
container_start_page | 7 |
container_title | Analytical biochemistry |
container_volume | 544 |
creator | Smajdor, Joanna Piech, Robert Ławrywianiec, Martyna Paczosa-Bator, Beata |
description | A voltammetric method for fast and sensitive estradiol determination using carbon black modified glassy carbon electrode (CBGC) is proposed. The use of carbon black as a modifying layer led to obtain low detection limit (9.2·10−8 mol L−1 for a preconcentration time of 60 s) and stability of registered signals (measured as RSD is 1.3%, n = 7, estradiol concentration 0.5·10−6 mol L−1). Cyclic voltammetry study revealed that in phosphate media estradiol suffers irreversible one-proton and one-electron oxidation process. Under the optimum conditions, estradiol calibration curve was linear in the concentration range from 0.15·10−6 to 3.5·10−6 mol L−1. The proposed method enable to determine estradiol content in different pharmaceutical formulation with good recovery. Amperometric measurements of estradiol were performed as well to indicate the possibility of its fast and accurate determination under the flow conditions.
[Display omitted] |
doi_str_mv | 10.1016/j.ab.2017.12.025 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1979168262</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0003269717305286</els_id><sourcerecordid>1979168262</sourcerecordid><originalsourceid>FETCH-LOGICAL-c350t-8e4f3d0981d2a96c02f4629f76124b6fa2b40639cf7788b5fe9441d4d53fda353</originalsourceid><addsrcrecordid>eNp1kUFv1DAQhS0Eokvhzgn5yCXBdhIn5oaqUipV4gJna2KPhRc7XuzsVvlH_EySbsutpznM997TzCPkPWc1Z1x-2tcw1oLxvuaiZqJ7QXacKVmxhqmXZMcYayohVX9B3pSyZ4zztpOvyYVQohsGMezI35sApSzUQB7TRDGgmXOySGOy3nm09N7Pv57WYwDzm7qUacGp-NmfkGKZM1ifArU4Y45-gtlv7EIjwlRocvSUwgwx4pwXCpOlLqR76qf9GrahMEFYii_nLIgHzGmDvXnwfIDeklcOQsF3j_OS_Px6_ePqW3X3_eb26stdZZqOzdWArWssUwO3ApQ0TLhWCuV6yUU7SgdibJlslHF9Pwxj51C1Lbet7RpnoemaS_Lx7HvI6c9xPU5HXwyGABOmY9Fc9YrLQUixouyMmpxKyej0IfsIedGc6a0fvdcw6q0fzYVe-1klHx7dj2NE-1_wVMgKfD4DuN548ph1MR4ng9bn9RHaJv-8-z8Vl6Q9</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1979168262</pqid></control><display><type>article</type><title>Glassy carbon electrode modified with carbon black for sensitive estradiol determination by means of voltammetry and flow injection analysis with amperometric detection</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals Complete</source><creator>Smajdor, Joanna ; Piech, Robert ; Ławrywianiec, Martyna ; Paczosa-Bator, Beata</creator><creatorcontrib>Smajdor, Joanna ; Piech, Robert ; Ławrywianiec, Martyna ; Paczosa-Bator, Beata</creatorcontrib><description>A voltammetric method for fast and sensitive estradiol determination using carbon black modified glassy carbon electrode (CBGC) is proposed. The use of carbon black as a modifying layer led to obtain low detection limit (9.2·10−8 mol L−1 for a preconcentration time of 60 s) and stability of registered signals (measured as RSD is 1.3%, n = 7, estradiol concentration 0.5·10−6 mol L−1). Cyclic voltammetry study revealed that in phosphate media estradiol suffers irreversible one-proton and one-electron oxidation process. Under the optimum conditions, estradiol calibration curve was linear in the concentration range from 0.15·10−6 to 3.5·10−6 mol L−1. The proposed method enable to determine estradiol content in different pharmaceutical formulation with good recovery. Amperometric measurements of estradiol were performed as well to indicate the possibility of its fast and accurate determination under the flow conditions.
[Display omitted]</description><identifier>ISSN: 0003-2697</identifier><identifier>EISSN: 1096-0309</identifier><identifier>DOI: 10.1016/j.ab.2017.12.025</identifier><identifier>PMID: 29258828</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Carbon - chemistry ; Carbon black ; Drug analysis ; Electrochemical Techniques ; Electrodes ; Estradiol ; Estradiol - analysis ; Flow Injection Analysis ; Hormone determination ; Voltammetry</subject><ispartof>Analytical biochemistry, 2018-03, Vol.544, p.7-12</ispartof><rights>2017 Elsevier Inc.</rights><rights>Copyright © 2017 Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c350t-8e4f3d0981d2a96c02f4629f76124b6fa2b40639cf7788b5fe9441d4d53fda353</citedby><cites>FETCH-LOGICAL-c350t-8e4f3d0981d2a96c02f4629f76124b6fa2b40639cf7788b5fe9441d4d53fda353</cites><orcidid>0000-0001-9551-0609</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.ab.2017.12.025$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29258828$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Smajdor, Joanna</creatorcontrib><creatorcontrib>Piech, Robert</creatorcontrib><creatorcontrib>Ławrywianiec, Martyna</creatorcontrib><creatorcontrib>Paczosa-Bator, Beata</creatorcontrib><title>Glassy carbon electrode modified with carbon black for sensitive estradiol determination by means of voltammetry and flow injection analysis with amperometric detection</title><title>Analytical biochemistry</title><addtitle>Anal Biochem</addtitle><description>A voltammetric method for fast and sensitive estradiol determination using carbon black modified glassy carbon electrode (CBGC) is proposed. The use of carbon black as a modifying layer led to obtain low detection limit (9.2·10−8 mol L−1 for a preconcentration time of 60 s) and stability of registered signals (measured as RSD is 1.3%, n = 7, estradiol concentration 0.5·10−6 mol L−1). Cyclic voltammetry study revealed that in phosphate media estradiol suffers irreversible one-proton and one-electron oxidation process. Under the optimum conditions, estradiol calibration curve was linear in the concentration range from 0.15·10−6 to 3.5·10−6 mol L−1. The proposed method enable to determine estradiol content in different pharmaceutical formulation with good recovery. Amperometric measurements of estradiol were performed as well to indicate the possibility of its fast and accurate determination under the flow conditions.
[Display omitted]</description><subject>Carbon - chemistry</subject><subject>Carbon black</subject><subject>Drug analysis</subject><subject>Electrochemical Techniques</subject><subject>Electrodes</subject><subject>Estradiol</subject><subject>Estradiol - analysis</subject><subject>Flow Injection Analysis</subject><subject>Hormone determination</subject><subject>Voltammetry</subject><issn>0003-2697</issn><issn>1096-0309</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kUFv1DAQhS0Eokvhzgn5yCXBdhIn5oaqUipV4gJna2KPhRc7XuzsVvlH_EySbsutpznM997TzCPkPWc1Z1x-2tcw1oLxvuaiZqJ7QXacKVmxhqmXZMcYayohVX9B3pSyZ4zztpOvyYVQohsGMezI35sApSzUQB7TRDGgmXOySGOy3nm09N7Pv57WYwDzm7qUacGp-NmfkGKZM1ifArU4Y45-gtlv7EIjwlRocvSUwgwx4pwXCpOlLqR76qf9GrahMEFYii_nLIgHzGmDvXnwfIDeklcOQsF3j_OS_Px6_ePqW3X3_eb26stdZZqOzdWArWssUwO3ApQ0TLhWCuV6yUU7SgdibJlslHF9Pwxj51C1Lbet7RpnoemaS_Lx7HvI6c9xPU5HXwyGABOmY9Fc9YrLQUixouyMmpxKyej0IfsIedGc6a0fvdcw6q0fzYVe-1klHx7dj2NE-1_wVMgKfD4DuN548ph1MR4ng9bn9RHaJv-8-z8Vl6Q9</recordid><startdate>20180301</startdate><enddate>20180301</enddate><creator>Smajdor, Joanna</creator><creator>Piech, Robert</creator><creator>Ławrywianiec, Martyna</creator><creator>Paczosa-Bator, Beata</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-9551-0609</orcidid></search><sort><creationdate>20180301</creationdate><title>Glassy carbon electrode modified with carbon black for sensitive estradiol determination by means of voltammetry and flow injection analysis with amperometric detection</title><author>Smajdor, Joanna ; Piech, Robert ; Ławrywianiec, Martyna ; Paczosa-Bator, Beata</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c350t-8e4f3d0981d2a96c02f4629f76124b6fa2b40639cf7788b5fe9441d4d53fda353</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Carbon - chemistry</topic><topic>Carbon black</topic><topic>Drug analysis</topic><topic>Electrochemical Techniques</topic><topic>Electrodes</topic><topic>Estradiol</topic><topic>Estradiol - analysis</topic><topic>Flow Injection Analysis</topic><topic>Hormone determination</topic><topic>Voltammetry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Smajdor, Joanna</creatorcontrib><creatorcontrib>Piech, Robert</creatorcontrib><creatorcontrib>Ławrywianiec, Martyna</creatorcontrib><creatorcontrib>Paczosa-Bator, Beata</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical biochemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Smajdor, Joanna</au><au>Piech, Robert</au><au>Ławrywianiec, Martyna</au><au>Paczosa-Bator, Beata</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Glassy carbon electrode modified with carbon black for sensitive estradiol determination by means of voltammetry and flow injection analysis with amperometric detection</atitle><jtitle>Analytical biochemistry</jtitle><addtitle>Anal Biochem</addtitle><date>2018-03-01</date><risdate>2018</risdate><volume>544</volume><spage>7</spage><epage>12</epage><pages>7-12</pages><issn>0003-2697</issn><eissn>1096-0309</eissn><abstract>A voltammetric method for fast and sensitive estradiol determination using carbon black modified glassy carbon electrode (CBGC) is proposed. The use of carbon black as a modifying layer led to obtain low detection limit (9.2·10−8 mol L−1 for a preconcentration time of 60 s) and stability of registered signals (measured as RSD is 1.3%, n = 7, estradiol concentration 0.5·10−6 mol L−1). Cyclic voltammetry study revealed that in phosphate media estradiol suffers irreversible one-proton and one-electron oxidation process. Under the optimum conditions, estradiol calibration curve was linear in the concentration range from 0.15·10−6 to 3.5·10−6 mol L−1. The proposed method enable to determine estradiol content in different pharmaceutical formulation with good recovery. Amperometric measurements of estradiol were performed as well to indicate the possibility of its fast and accurate determination under the flow conditions.
[Display omitted]</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>29258828</pmid><doi>10.1016/j.ab.2017.12.025</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0001-9551-0609</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2697 |
ispartof | Analytical biochemistry, 2018-03, Vol.544, p.7-12 |
issn | 0003-2697 1096-0309 |
language | eng |
recordid | cdi_proquest_miscellaneous_1979168262 |
source | MEDLINE; Elsevier ScienceDirect Journals Complete |
subjects | Carbon - chemistry Carbon black Drug analysis Electrochemical Techniques Electrodes Estradiol Estradiol - analysis Flow Injection Analysis Hormone determination Voltammetry |
title | Glassy carbon electrode modified with carbon black for sensitive estradiol determination by means of voltammetry and flow injection analysis with amperometric detection |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T08%3A48%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Glassy%20carbon%20electrode%20modified%20with%20carbon%20black%20for%20sensitive%20estradiol%20determination%20by%20means%20of%20voltammetry%20and%20flow%20injection%20analysis%20with%20amperometric%20detection&rft.jtitle=Analytical%20biochemistry&rft.au=Smajdor,%20Joanna&rft.date=2018-03-01&rft.volume=544&rft.spage=7&rft.epage=12&rft.pages=7-12&rft.issn=0003-2697&rft.eissn=1096-0309&rft_id=info:doi/10.1016/j.ab.2017.12.025&rft_dat=%3Cproquest_cross%3E1979168262%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1979168262&rft_id=info:pmid/29258828&rft_els_id=S0003269717305286&rfr_iscdi=true |